1.Research advances in the disease burden of viral hepatitis in China
Jian LI ; Fuzhen WANG ; Zhongdan CHEN ; Jinlei QI ; Ailing WANG ; Fanghui ZHAO ; Yuanyuan KONG ; Jing SUN ; Jiaqi KANG ; Zundong YIN ; Zhongfu LIU ; Jidong JIA ; Yu WANG
Journal of Clinical Hepatology 2025;41(2):221-227
Over the past three decades, China has made significant progress in the prevention and control of viral hepatitis, and the incidence rates of new-onset pediatric hepatitis B virus infections and acute viral hepatitis in the population have reduced to a relatively low level; however, there is still a heavy disease burden of chronic viral hepatitis in China, which severely affects the health status of the population. This study systematically summarizes the achievements of viral hepatitis prevention and control in China, analyzes existing problems and challenges, and proposes comprehensive prevention and control strategies and measures to eliminate viral hepatitis as a public health threat based on the national conditions of China, in order to provide a reference for related departments in China on how to achieve the action targets for eliminating viral hepatitis as a public health threat by 2030.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Relationship between zinc finger protein A20, CTGF and FibroScan and fibrosis in chronic hepatitis B patients
Song ZHANG ; Zilong ZHAO ; Qian HU ; Jian LI ; Xiaojing WANG ; Huijie GENG ; Haiyan KANG ; Dianxing SUN ; Zhengrong GUO
Journal of Public Health and Preventive Medicine 2024;35(3):133-136
Objective Studies on the expression and location of zinc finger protein A20 (A20) and connective tissue growth factor (CTGF) in liver tissues of patients with chronic hepatitis B were conducted, and the relationship between them and liver fibrosis was determined by FibroScan. Methods Studies on A20 and CTGF in liver tissues of 160 patients with chronic hepatitis B were conducted in accordance with the stage of pathological fibrosis and inflammation of the liver, and quantitative immunohistochemistry test was conducted, and statistical analysis was conducted by FibroScan. Results The expressions of A20 and CTGF in liver tissues increased with the aggravation of liver pathological fibrosis and inflammation, and there were significant differences between each stage and the control group (P<0.05), and there were significant differences between adjacent groups (P<0.05). Studies have shown that FibroScan increases along with pathological fibrosis and inflammation in the liver. There are significant differences between the stage and the control group (P<0.05), and no significant differences between the adjacent groups (P>0.05). There was positive correlation between liver A20 and CTGF, r=0.796 (P<0.05). Conclusions In patients with chronic hepatitis B, A20, CTGF and FibroScan are positively correlated with the degree of liver fibrosis, and A20 and CTGF are also positively correlated with the degree of liver inflammation, which can be used as indicators to evaluate the degree of liver inflammation and fibrosis, and further guide the anti-inflammatory and anti-fibrosis treatment of patients.
8.Quantitative CT measurement of bone mass density in different regions of the distal clavicle in reconstruction of acromioclavicular joint dislocation
Jian XU ; Wenzhi BI ; Yuncong JI ; Yunkang KANG ; Peiqi MA ; Jialiang WANG ; Zongxi ZHANG ; Fusheng GAN ; Haiyang YU ; Biao GUO
Chinese Journal of Tissue Engineering Research 2024;28(12):1920-1924
BACKGROUND:There is no consensus on the optimal bone tunnel position in the lateral clavicle,which guides coracoclavicular ligament reconstruction.Postoperative complications such as enlargement of the lateral clavicle bone tunnel,bone osteolysis,clavicle fracture,and failure of internal fixation are likely to occur.Bone mass density plays an important role in the strength and stability of endophytic fixation.Regional differences in the bone mass density of the distal clavicle should not be overlooked in the repair and reconstruction of acromioclavicular dislocation.Currently,there are no quantitative clinical studies in humans regarding the bone mass density of the distal clavicle. OBJECTIVE:To measure the magnitude of bone mass density in different regions of the distal clavicle by quantitative CT to provide a reference for surgeons to repair and reconstruct the coracoclavicular ligament. METHODS:101 patients undergoing quantitative CT checking in Fuyang People's Hospital Affiliated to Anhui Medical University from October to December 2022 were enrolled,from which 1 616 samples of subdivisional bone mass density of the distal clavicle were measured.For each of the quantitative CT samples,firstly,the distal clavicle was divided medially to laterally into the following four regions:conical nodal region(region A),inter-nodal region(region B),oblique crest region(region C)and distal clavicular region(region D).Secondly,each region was divided into the first half and the second half to determine eight subdivisions,then setting semiautomatic region of interest(ROI)in each subdivision:(ROI A1,A2,B1,B2,C1,C2,D1,and D2).Thirdly,each quantitative CT scan was transferred to the quantitative CT pro analysis workstation,and cancellous bone mass density was measured in the distal clavicle ROI.Finally,the clavicular cortex was avoided when measuring. RESULTS AND CONCLUSION:(1)There was no statistically significant difference in bone mineral density on the different sides of the shoulder(P>0.05).(2)The analysis of bone mineral density in eight sub-areas of the distal clavicle A1,A2,B1,B2,C1,C2,D1,and D2 showed statistically significant differences(P<0.05).It could be considered that there were differences in bone mineral density in different areas of the distal clavicle.After pairwise comparison,there was no statistically significant difference in bone mineral density between A1 and A2,D1 and D2,A2 and B1(P>0.05),and there was a statistically significant difference in bone mineral density between the other sub-areas(P<0.05).(3)The bone mineral density in the region A2 of the anatomical insertion of the conical ligament was significantly higher than that in the inter-nodular area(region B)(P<0.05).The bone mineral density in the region A1 was higher than that in the region A2,but the difference was not statistically significant(P>0.05).The bone mineral density in the region C1 of the anatomical insertion of the trapezium ligament was higher than that in regions C2,D1 and D2,and the bone mineral density in the inter-nodular area(region B)was significantly higher than that in regions C and D(P<0.05).(4)These results have suggested that there are differences in bone mass density in different regions of the distal clavicle;regional differences in bone mass density in the distal clavicle during repair and reconstruction of acromioclavicular dislocation cannot be ignored.Consideration should be given not only to biomechanical factors but also to the placement of implants or bone tunnels in regions of higher bone mass density,which could improve the strength and stability of implant fixation and reduce the risk of complications such as bone tunnel enlargement,osteolysis,fracture and implant failure.
9.The Genetic Polymorphism and Structural Analysis of 47 Microhaplotypes in a Jiangsu Changshu Chinese Han Population
Kun-Peng PAN ; Yao-Sen FENG ; Wen-Shuai YU ; Zong-Wei LIU ; Yi-Ren YAO ; Jie ZHAO ; Ke-Lai KANG ; Chi ZHANG ; Le WANG ; Jian WU
Progress in Biochemistry and Biophysics 2024;51(2):423-434
ObjectiveTo investigate the genetic polymorphism and structure of 47 autosomal microhaplotypes in the Han population in Changshu City, Jiangsu Province, and to evaluate the forensic efficiencies and forensic parameters. MethodsThe DNA library of unrelated individual samples was prepared according to MHSeqTyper47 kit manual and sequenced on the MiSeq FGx platform. Microhaplotype genotyping and sequencing depth statistics were processed using MHTyper. The genetic information of samples was then evaluated. The fixation index and genetic distance between the Jiangsu Changshu population and the reference populations in the 1000 Genomes Project phase 3 (1KG) were calculated, and forensic parameters were evaluated. ResultsThe fixation index and genetic distance between the Han population in Changshu, Jiangsu, and the CHB (Han Chinese in Beijing, China) reference population in 1KG were the lowest. The effective allele number (Ae) of each locus is also the closest between the two populations. The combined matching probability (CMP) of the Changshu Han population is close to the 5 populations of the East Asian reference super-population in 1KG, which is 1.25×10-36, and the combined probability of exclusion reached 0.999 999 999 964 1. ConclusionThis study reported the genetic polymorphism and allele frequency of 47 microhaplotypes in a Han population in Changshu City, Jiangsu Province. This information provides a data basis for 47 microhaplotypes in forensic applications. In addition, the polymorphism differences between the 1KG reference population and the Han population in Changshu, Jiangsu were compared, and the genetic structure of 47 microhaplotypes in the Han population in Changshu, Jiangsu was revealed. In general, the reference data of the East Asian super-population in 1KG is more in line with the genetic characteristics of Han population in Changshu, Jiangsu.
10.Effect of preemptive analgesia with ibuprofen on postoperative pain after mandibular third molar extraction: a randomized controlled trial
Xuezhu WEI ; Kang GAO ; Jing ZHANG ; Bin ZHAO ; Zhiguang LIU ; Ruiqing WU ; Mingming OU ; Qi ZHANG ; Wei LI ; Qian CHENG ; Yilin XIE ; Tianyi ZHANG ; Yajie LI ; Hao WANG ; Zuomin WANG ; Wei ZHANG ; Jian ZHOU
Chinese Journal of Stomatology 2024;59(3):230-236
Objective:To evaluate the impact of preemptive analgesia with ibuprofen on postoperative pain following the extraction of impacted mandibular third molars in a Chinese population, aiming to provide a clinical reference for its application.Methods:This multicenter, randomized, double-blind, placebo-controlled parallel-group trial was conducted from April 2022 to October 2023 at the Capital Medical University School of Stomatology (40 cases), Beijing TianTan Hospital, Capital Medical University (22 cases), and Beijing Chao-Yang Hospital, Capital Medical University (20 cases). It included 82 patients with impacted mandibular third molars, with 41 in the ibuprofen group and 41 in the control group. Participants in the ibuprofen group received 300 mg of sustained-release ibuprofen capsules orally 15 min before surgery, while the control group received a placebo. Both groups were instructed to take sustained-release ibuprofen capsules as planned for 3 days post-surgery. Pain intensity was measured using the numerical rating scale at 30 min, 4 h, 6 h, 8 h, 24 h, 48 h, and 72 h after surgery, and the use of additional analgesic medication was recorded during days 4 to 6 postoperatively.Results:All 82 patients completed the study according to the protocol. No adverse events such as nausea, vomiting, or allergies were reported in either group during the trial. The ibuprofen group exhibited significantly lower pain scores at 4 h [2.0 (1.0, 4.0) vs. 4.0 (3.0, 5.0)] ( Z=-3.73, P<0.001), 6 h [2.0 (1.0, 4.0) vs. 5.0(2.5, 6.0)] ( Z=-3.38, P<0.001), and 8 h [2.0 (1.0, 4.0) vs. 5.0 (2.0, 6.0)] ( Z=-2.11, P=0.035) postoperatively compared to the control group. There were no statistically significant differences in pain scores between the groups at 30 min, 24 h, 48 h, and 72 h postoperatively ( P>0.05). Additionally, 11 out of 41 patients (26.8%) in the ibuprofen group and 23 out of 41 patients (56.1%) in the control group required extra analgesic medication between days 4 and 6 post-surgery, with the ibuprofen group taking significantly fewer additional pills [0.0 (0.0, 1.0) vs. 1.0 (0.0, 3.0)] ( Z=-2.81, P=0.005). Conclusions:A pain management regimen involving 300 mg of oral sustained-release ibuprofen capsules administered 15 minutes before surgery and continued for 3 d postoperatively effectively reduces pain levels and the total amount of analgesic medication used after the extraction of impacted mandibular third molars. Considering its efficacy, safety, and cost-effectiveness, ibuprofen is recommended as a first-line drug for perioperative pain management, enhancing patient comfort during diagnosis and treatment in a feasible manner.


Result Analysis
Print
Save
E-mail