1.Translational Research of Electromagnetic Fields on Diseases Related With Bone Remodeling: Review and Prospects
Peng SHANG ; Jun-Yu LIU ; Sheng-Hang WANG ; Jian-Cheng YANG ; Zhe-Yuan ZHANG ; An-Lin LI ; Hao ZHANG ; Yu-Hong ZENG
Progress in Biochemistry and Biophysics 2025;52(2):439-455
Electromagnetic fields can regulate the fundamental biological processes involved in bone remodeling. As a non-invasive physical therapy, electromagnetic fields with specific parameters have demonstrated therapeutic effects on bone remodeling diseases, such as fractures and osteoporosis. Electromagnetic fields can be generated by the movement of charged particles or induced by varying currents. Based on whether the strength and direction of the electric field change over time, electromagnetic fields can be classified into static and time-varying fields. The treatment of bone remodeling diseases with static magnetic fields primarily focuses on fractures, often using magnetic splints to immobilize the fracture site while studying the effects of static magnetic fields on bone healing. However, there has been relatively little research on the prevention and treatment of osteoporosis using static magnetic fields. Pulsed electromagnetic fields, a type of time-varying field, have been widely used in clinical studies for treating fractures, osteoporosis, and non-union. However, current clinical applications are limited to low-frequency, and research on the relationship between frequency and biological effects remains insufficient. We believe that different types of electromagnetic fields acting on bone can induce various “secondary physical quantities”, such as magnetism, force, electricity, acoustics, and thermal energy, which can stimulate bone cells either individually or simultaneously. Bone cells possess specific electromagnetic properties, and in a static magnetic field, the presence of a magnetic field gradient can exert a certain magnetism on the bone tissue, leading to observable effects. In a time-varying magnetic field, the charged particles within the bone experience varying Lorentz forces, causing vibrations and generating acoustic effects. Additionally, as the frequency of the time-varying field increases, induced currents or potentials can be generated within the bone, leading to electrical effects. When the frequency and power exceed a certain threshold, electromagnetic energy can be converted into thermal energy, producing thermal effects. In summary, external electromagnetic fields with different characteristics can generate multiple physical quantities within biological tissues, such as magnetic, electric, mechanical, acoustic, and thermal effects. These physical quantities may also interact and couple with each other, stimulating the biological tissues in a combined or composite manner, thereby producing biological effects. This understanding is key to elucidating the electromagnetic mechanisms of how electromagnetic fields influence biological tissues. In the study of electromagnetic fields for bone remodeling diseases, attention should be paid to the biological effects of bone remodeling under different electromagnetic wave characteristics. This includes exploring innovative electromagnetic source technologies applicable to bone remodeling, identifying safe and effective electromagnetic field parameters, and combining basic research with technological invention to develop scientifically grounded, advanced key technologies for innovative electromagnetic treatment devices targeting bone remodeling diseases. In conclusion, electromagnetic fields and multiple physical factors have the potential to prevent and treat bone remodeling diseases, and have significant application prospects.
2.Two new flavonoid glycosides from Diphylleia sinensi
Hao-jie WANG ; Chen ZHAO ; Yan-jun SUN ; Jian-hong GONG ; Hong-yun BAI ; Hui CHEN ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2024;59(3):673-677
Five flavonoid glycosides were isolated from the methanol and ethyl acetate fractions of the ethanol extract of
3.Superior vena cava syndrome and pulmonary artery stenosis in a patient with lung metastases of bladder cancer
Jian-Ke LI ; Ya-Nan GU ; Jun-Hao LI ; Liang-Wen WANG ; Ning-Zi TIAN ; Wei CHEN ; Xiao-Lin WANG ; Yi CHEN
Fudan University Journal of Medical Sciences 2024;51(2):277-279,284
Superior vena cava syndrome(SVCS)is a group of clinical syndromes caused by obstruction of the superior vena cava and its major branches from various causes.Pulmonary artery stenosis(PS)is a complication of lung cancer or mediastinal tumours.SVCS combined with PS due to pulmonary metastases from bladder cancer is extremely rare and has not been reported in the literature.Here we reported an old male patient with pulmonary metastases from bladder cancer presenting with swelling of the head,neck and both upper limbs.SVCS combined with PS was clarified by pulmonary artery computed tomography angiography(CTA)and digital subtraction angiography(DSA).Endovascular stenting was used to treat SVCS.Angiography also showed that PS had not caused pulmonary hypertension and did not need to be treated.The swelling of the patient's head,neck and upper limbs was gradually reduced after the procedure.
4.Autologous platelet-rich plasma treatment for infected deep second-degree burn wounds: a case report
Hao HUANG ; Jun HUANG ; Qun LIANG ; Jian LIU ; Ting LI ; Yang ZHAO
Chinese Journal of Blood Transfusion 2024;37(1):95-100
【Objective】 To explore the feasibility of using autologous platelet-rich plasma (PRP) in the treatment of deep second-degree burns complicated with wound infection. 【Methods】 A retrospective analysis was conducted on the treatment process of a patient with deep second-degree burns and bacterial infection on the wound using autologous PRP. Clinical treatment highlights and outpatient follow-up were combined to discuss the feasibility and clinical effects of using autologous PRP in the treatment of burn wounds complicated with infection. 【Results】 The patient had a deep second-degree burn with a coagulase-negative Staphylococcus infection on the left lower limb. After one week of conventional wound dressing and antibiotic treatment, the patient's body temperature returned to normal. However, wound healing was slow and yellow secretion persisted. Subsequently, the burn wound was treated combined with topical autologous PRP. The wound pain score gradually decreased from 8 to 1. After 2 weeks, the bacterial culture of the wound secretion was negative, and the wound healed completely after 18 days. The wound scar score decreased from 5 to 2 at 1, 3 and 6 months after PRP treatment, and no obvious scar formation was observed. In the course of PRP treatment, there were no adverse reactions such as increased wound inflammation, abnormal blood routine and liver and kidney function test results. 【Conclusion】 For deep second-degree burn patients with localized wound bacterial infections who either refuse surgery or are not suitable for surgery, autologous PRP is a safer alternative that can effectively promote tissue regeneration and wound healing. The patient in this case achieved a curative effect in a short period of time.
5.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
6.Arthroscopic all-inside reconstruction of isolated posterior cruciate ligament injury
Jian XIAO ; Hao LI ; Jun YAN ; Fan HU ; Ce WANG ; Gengyan XING
Chinese Journal of Orthopaedics 2024;44(3):139-145
Objective:To investigate the indications and effects of arthroscopic all-inside reconstruction in the treatment of isolated posterior cruciate ligament (PCL) injury.Methods:A retrospective analysis was performed on 47 patients with isolated PCL injury, who underwent arthroscopic all-inside reconstruction in the Third Medical Center of the PLA General Hospital from January 2016 to January 2020. There were 39 males and 8 females, aged 27.14±7.70 years old (range 16-40 years old). The preoperative kneeling-position stress X-ray showed that the degree of tibial posterior displacement was 8-10 mm, which was a complete and isolated Grade II PCL injury. The tibial and femoral tunnels were created through posterior-medial, anteromedial, and anterolateral portals, while the lateral portal to the medial femoral condyle was enlarged to position the tibial tunnel and protect the anterior cruciate ligament. The autologous graft tendon was pulled through the femoral and tibial tunnels secured with an adjustable loop plate. The efficacy was evaluated by evaluating and comparing preoperative and postoperative Lachman test, posterior drawer test, knee range of motion and relaxation, pain visual analogue scale (VAS) and Lysholm score.Results:43 patients were followed up for 35.21±3.88 months (range 12-40 months). The symptoms of knee instability all improved after surgery. At the follow-up of 1 year after surgery, 41 (95%) and 40 (93%) patients showed normal or I-degree laxity in Lachman test and posterior drawer test, respectively. The active range of motion and passive flexion of the knee joint were increased to 90°-110° and 110°-130°, respectively. The Lysholm score was 86.44±4.08 at the first year of follow-up and 90.12±3.33 at the last follow-up with significant difference compared with pre-operations ( P<0.05). The VAS score was 2.07±0.94 at the first year of follow-up and 1.28±0.83 at the last follow-up with significant difference compared with pre-operations ( P<0.05). The Lysholm score and VAS were 90.12±3.33 and 1.28±0.83, which were significantly improved compared to 1-year-follow-up ( P<0.05). Conclusion:Routine kneeling stress X-rays can evaluate the degree of tibial posterior displacement in isolated PCL injuries. With tibial posterior displacement equal to or greater than 10 mm, surgical reconstruction was required. All-inside reconstruction of isolated PCL injury was a safe and minimally invasive surgery to improve symptoms and restore knee functions.
7.The Implementation, Clinical Progress and Technical Challenges of Implantable Brain-Computer Interface Systems
Wen-Can QIU ; Liang MA ; Hao-Yue GUO ; Jun-Jie YANG ; Xiao-Jian LI
Progress in Biochemistry and Biophysics 2024;51(10):2478-2497
The breakthrough progress of implantable brain-computer interfaces (iBCIs) technology in the field of clinical trials has attracted widespread attention from both academia and industry. The development and advancement of this technology have provided new solutions for the rehabilitation of patients with movement disorders. However, challenges from many aspects make it difficult for iBCIs to further implement and transform technologies. This paper illustrates the key challenges restricting the large-scale development of iBCIs from the perspective of system implementation, then discusses the latest clinical application progress in depth, aiming to provide new ideas for researchers. For the system implementation part, we have elaborated the front-end signal collector, signal processing and decoder, then the effector. The most important part of the front-end module is the neural electrode, which can be divided into two types: piercing and attached. These two types of electrodes are newly classified and described. In the signal processing and decoder section, we have discussed the experimental paradigm together with signal processing and decoder for the first time and believed that the experimental paradigm acts as a learning benchmark for decoders that play a pivotal role in iBCIs systems. In addition, the characteristics and roles of the effectors commonly used in iBCIs systems, including cursors and robotic arms, are analyzed in detail. In the clinical progress section, we have divided the latest clinical progress into two categories: functional rehabilitation and functional replacement from the perspective of the application scenarios of iBCIs. Functional rehabilitation and functional replacement are two different types of application, though the boundary between the two is not absolute. To this end, we have first introduced the corresponding clinical trial progress from the three levels: application field, research team, and clinical timeline, and then conducted an in-depth discussion and analysis of their functional boundaries, in order to provide guidance for future research. Finally, this paper mentions that the key technical challenges in the development of iBCIs technology come from multiple aspects. First of all, from the signal acquisition level, high-throughput and highly bio-compatible neural interface designing is essential to ensure long-term stable signal acquisition. The electrode surface modification method and electrode packaging were discussed. Secondly, in terms of decoding performance, real-time, accurate, and robust algorithms have a decisive impact on improving the reliability of iBCIs systems. The third key technology is from the perspective of practicality, we believe that the signal transmission mode of wireless communication is the trend of the future, but it still needs to overcome challenges such as data transmission rate and battery life. Finally, we believe that issues such as ethics, privacy, and security need to be addressed through legal, policy, and technological innovation. In summary, the development of iBCIs technology requires not only the unremitting efforts of scientific researchers, but also the participation and support of policymakers, medical professionals, technology developers, and all sectors of society. Through interdisciplinary collaboration and innovation, iBCIs technology will achieve wider clinical applications in the future and make important contributions to improving the quality of life of patients.
8.Micromorphological characteristics of the pedicle of the lower cervical vertebra
Kun LI ; Shaojie ZHANG ; Jun SHI ; Jian WANG ; Yanan LIU ; Lan DUO ; Yang YANG ; Yunteng HAO ; Zhijun LI ; Xing WANG
Chinese Journal of Tissue Engineering Research 2024;28(12):1890-1894
BACKGROUND:The lower cervical vertebral pedicle is the main stress site of the posterior column of the spine,which is of great significance for the maintenance of the stability of the human center of gravity and the reduction of shock.At present,there are few reports on the characteristics of the internal bone trabeculae,and the characteristics of the joint site of the vertebral pedicle with the articular process and the vertebral body.It is urgent to understand the fine anatomical structure of the vertebral pedicle and the relationship and function of each part. OBJECTIVE:To observe the microanatomical morphology of the vertebral pedicle by Micro-CT scanning of cervical vertebra specimens,and to measure and analyze the microstructure and morphometric parameters of the bone trabecula in the cervical pedicle under normal conditions to evaluate the safety performance of the cervical spine. METHODS:Micro-CT scanning was performed on 31 sets of cervical vertebrae C3-C7.By checking and reconstructing the areas of interest in the bone trabecular within the vertebral pedicle,the morphological characteristics and distribution direction of the bone trabecular within the cervical pedicle were observed,and the bone microstructure parameters were detected,and the differences in the bone microstructure of the C3-C7 vertebral pedicle were analyzed and compared. RESULTS AND CONCLUSION:(1)The Micro-CT images showed that the honeycomb bone trabeculae of the pedicle of the lower cervical spine presented a complex network of microstructures.The trabeculae near the cortical bone were lamellar and relatively compact,extending forward toward the vertebral body and backward toward the articular process lamina.Abatoid bone trabeculae extended into the medullary cavity and transformed into a network structure,and then into rod-shaped bone trabeculae.The rod-shaped bone trabeculae were sparsely distributed in the medullary cavity.(2)Statistical results of morphological parameters of bone trabeculae showed that bone volume fraction values in C4 and C5 were higher than that in C7(P<0.05).The bone surface/bone volume value in C7 was higher than that in C3,C4 and C6(P<0.05).The bone surface density of bone trabeculae in C7 was higher than that in C3,C4,C5 and C6(P<0.05).Trabecular thickness in C7 was higher than that in C3,C4 and C5(P<0.05).Bone surface/bone volume and bone surface density of the left pedicle bone trabecular were greater than those on the right side(P<0.05).(3)The microstructural changes of C3-C7 were summarized,in which the load capacity and stress of the C7 pedicle were poor,and the risk of injury was high in this area.
9.Application of miniprobe endoscopic ultrasound in endoscopic surgery of small-diameter and low-grade rectum neuroendocrine neoplasm
Jian-Jun LI ; Chao-Qiang FAN ; Xin YANG ; Xue PENG ; Hao LIN ; Xu-Biao NIE ; Shi-Ming YANG ; Qiu-Jian QIAO ; Jian-Ying BAI
Journal of Regional Anatomy and Operative Surgery 2024;33(1):59-62
Objective To evaluate the value of miniprobe endoscopic ultrasound(EUS)in guiding endoscopic treatment of small-diameter(maximum diameter less than 1 cm)and low-grade(G1 grade)rectum neuroendocrine neoplasm(R-NEN),and to provide evidence and clues for its clinical application and further research.Methods The clinical data of 85 cases of low-grade(G1 grade)R-NEN with a maximum diameter of less than 1 cm who underwent endoscopic treatment in our center from January 2014 to December 2020 were retrospectively analyzed.The patients were divided into the EUS group(37 cases)and control group(48 cases)according to whether EUS was performed before endoscopic treatment.The positive rate of incision margin,the incidence of complications,the recurrence rate,the hospital stay,the cost of hospitalization and endoscopic therapy were compared between the two groups.Results The positive rate of incision margin in the EUS group was significantly lower than that in control group(P<0.05).There was no significant difference in the incidence of complications,tumor recurrence rate,hospital stay or hospital costs between the two groups(P>0.05).There was statistically significant difference in the endoscopic therapy between the two groups(P<0.05).Conclusion Evaluating the lesion depth of small-diameter and low-grade(G1 grade)R-NEN before surgery by miniprobe EUS and selecting endoscopic surgery according to its results of can significantly reduce the residual risk of resection margin tumors.
10.Clinical management strategies for recipients with renal graft loss
Hao YANG ; Jun LIN ; Jian ZHANG
Organ Transplantation 2024;15(1):138-144
With the maturity of kidney transplantation, introduction of new immunosuppressive drugs and improvement of immunosuppressive regimen, the short-term survival rate of kidney transplant recipients has been significantly improved, whereas the long-term survival rate has not been significantly elevated. Kidney transplant recipients may have the risk of renal graft loss. Clinical management after renal graft loss is complicated, including the adjustment of immunosuppressive drugs, management of renal graft and selection of subsequent renal replacement therapy. These management procedures directly affect clinical prognosis of patients with renal graft loss. Nevertheless, relevant guidelines or consensuses are still lacking. Clinical management of patients after renal graft loss highly depend upon clinicians’ experience. In this article, the adjustment of immunosuppressive drugs, management of renal graft and selection of subsequent renal replacement therapy were reviewed, aiming to provide reference for prolonging the survival and improving the quality of life of these patients.

Result Analysis
Print
Save
E-mail