1.Continuous vital signs monitoring using wireless wearable devices in patients after video-assisted thoracoscopic surgery for lung cancer: A prospective self-control study
Xiaoli MEI ; Yuchen HUANG ; Jian ZHOU ; Yuanyuan SONG ; Ailin LUO ; Mei YANG ; E ZHENG ; Yang QIU ; Beinuo WANG ; Zhenghao DONG ; Hu LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):229-235
Objective To explore the reliability and safety of continuous monitoring of vital signs in patients using wireless wearable monitoring devices after video-assisted thoracoscopic surgery (VATS) for lung cancer. Methods The patients undergoing VATS for lung cancer in West China Hospital, Sichuan University from May to August 2023 were prospectively enrolled. Both wireless wearable and traditional wired devices were used to monitor the vital signs of patients after surgery. Spearman correlation analysis, paired sample t test and ratio Bland-Altman method were used to test the correlation, difference and consistency of monitoring data measured by the two devices. The effective monitoring rate of the wireless wearable device within 12 hours was calculated to test the reliability of its continuous monitoring. Results A total of 20 patients were enrolled, including 15 females and 5 males with an average age of 46.20±11.52 years. Data collected by the two monitoring devices were significantly correlated (P<0.001). Respiratory rate and blood oxygen saturation data collected by the two devices showed no statistical difference (P>0.05), while heart rate measured by wireless wearable device was slightly lower (=−0.307±1.073, P<0.001), and the blood pressure (=1.259±5.354, P<0.001) and body temperature(=0.115±0.231, P<0.001) were slightly higher. The mean ratios of heart rate, respiratory rate, blood oxygen saturation, blood pressure and body temperature collected by the two devices were 0.996, 1.004, 1.000, 1.014, and 1.003, respectively. The 95% limits of agreement (LoA) and 95% confidence interval of 95%LoA of each indicator were within the clinically acceptable limit. The effective monitoring rate of each vital signs within 12 hours was above 98%. Conclusion The wireless wearable device has a high accuracy and reliability for continuous monitoring vital signs of patients after VATS for lung cancer, which provides a security guarantee for subsequent large-scale clinical application and further research.
2.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
3.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
4.Progress in research on mRNA drugs for the treatment of genetic diseases
Wenjun SHI ; Xianshuo CHENG ; Pei LUO ; Jilong MA ; Jian DONG
Chinese Journal of Medical Genetics 2024;41(3):368-376
In recent years, mRNA drugs have shown a great potential for the treatment of genetic diseases and attracted the attention of many researchers. This article has reviewed the advance in the research of mRNA drugs for the treatment of genetic diseases over the past 30 years, including their mechanisms of action and structure design, with a focus on their advantages as alternative therapies such as high specificity, low dosage, and sustained expression. Meanwhile, challenges for the effective delivery and storage methods for the mRNA drugs are discussed, with an aim to provide guidance for subsequent researches.
5.Right heart function parameters in patients with Ebstein anomaly:Correlations of evaluation of echocardiography and MRI
Jiang WANG ; Ting JIANG ; Wanyu ZHAO ; Jian LI ; Yunxing DONG ; Yan SHEN ; Zhiling LUO
Chinese Journal of Medical Imaging Technology 2024;40(1):47-50
Objective To explore the correlations of evaluations of right heart function parameters in patients with Ebstein anomaly(EA)using echocardiography and cardiac MRI.Methods Data of transthoracic echocardiography and cardiac MRI in 32 patients with EA confirmed by operation were retrospectively analyzed.The correlations of cardiac cavity size,right ventricular function and strain parameters obtained using echocardiography and the functional right ventricular(fRV)ejection fraction(EF)measured using MRI were explored.Results MRI fRV-EF in 32 cases of EA was(23.20± 7.61)%.Among echocardiographic parameters in 32 cases of EA,fractional area change(FAC)of fRV(r=0.347,P=0.015)was slightly,while global longitudinal strain(GLS)of fRV(r=0.801,P<0.001)was highly positively correlated with MRI fRV-EF,respectively,whereas atrialized right ventricle(aRV)area/fRV area(r=-0.730,P=0.007)was highly negatively,aRV area/left ventricular area(r=-0.450,P=0.042)and right ventricular anterior-posterior diameter(r=-0.650,P=0.022)were both moderately negatively correlated with MRI fRV-EF.Both the left ventricular eccentricity index(r=-0.347,P=0.049)and Glasgow outcome scale extended(r=-0.336,P=0.024)obtained with echocardiography were slightly negatively correlated MRI fRV-EF.Conclusion Right heart function parameters in EA patients obtained with echocardiography were correlated with those of MRI fRV-GLS,among which aRV area/fRV area were highly positively correlated with MRI fRV-EF,hence having great value for evaluating right heart function in EA patients.
6.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
7.Clinical characteristics of patients with rheumatic diseases and abnormal liver function
Chanyuan WU ; Mucong LI ; Xinwang DUAN ; Hongbin LI ; Yanhong WANG ; Qin LI ; Hui LUO ; Jian XU ; Lijun WU ; Yongfu WANG ; Cheng ZHAO ; Yongfei FANG ; Shudian LIN ; Dong XU ; Xinping TIAN ; Mengtao LI ; Xiaofeng ZENG
Chinese Journal of Internal Medicine 2023;62(9):1102-1113
Objective:To investigate the clinical characteristics of patients with rheumatic diseases and abnormal liver function, as well as determine the proportion and severity of liver function abnormalities.Methods:Cross-sectional study. Data were collected from patients registered in the Chinese Rheumatism Date Center from 2011 to 2021. The rheumatic diseases analyzed in this study were rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), Sjogren syndrome (SS), ankylosing spondylitis (AS), and gout. Patient data, including demographic characteristics [ such as age, sex, body mass index,(BMI), and smoking history], liver function test results [including alanine aminotransferase (ALT), aspartate aminotransferase, alkaline phosphatase(ALP), and total bilirubin], and use of anti-rheumatic immune drugs and liver-protective drugs, were collected and compared between groups with normal and abnormal liver functions. In addition, the proportions of abnormal liver function were compared between sex and age groups.Results:A total of 116 308 patients were included in this study, including 49 659 with RA, 17 597 with SLE, 9 039 with SS, 11 321 with AS, and 28 692 with gout. The lowest proportion of liver function abnormalities was observed in patients with RA[11.02% (5 470/49 659)], followed by those with SS[17.97% (1 624/9 039)] and AS [18.22% (2 063/11 321) ], whereas patients with SLE [21.14% (3 720/17 597) ] and gout [28.73% (8 242/28 692)] exhibited the highest proportion of these abnormalities. Elevated ALT, mostly classified as grade 1, was the most commonly noted liver function abnormality, whereas elevated ALP was the least common. Some patients who took liver-protective drugs had normal liver function, with the lowest percentage observed in patients with gout [7.45% (36/483) ] and ranging from 21.7% to 30.34% in patients with RA, SLE, SS, and AS. The proportion of liver function abnormalities was higher in males than in females for all disease types [RA: 13.8%(1 368/9 906) vs. 10.3%(4 102/39 753); SLE: 33.6% (479/1 424) vs. 20.0% (3 241/16 173); SS: 25.4%(111/437) vs. 17.6%(1 513/8 602); AS: 20.1%(1 629/8 119) vs. 13.6% (434/3 202); and gout: 29.3% (8 033/27 394) vs. 16.1% (209/1 298)]. In RA, SLE, and AS, the proportions of liver function abnormalities were similar across all age groups. In SS, the proportion of liver function abnormalities increased with age [<40 years: 14.9%(294/1 979); 40-59 years: 18.1%(858/4 741); ≥60 years: 20.4%(472/2 319)], whereas a reversal of this trend was observed in gout [<40 years: 34.9%(4 294/12 320); 40-59 years: 25.5%(2 905/11 398);≥60 years: 21.0%(1 042/4 971)].Conclusions:The proportions of combined liver function abnormalities in patients with rheumatologic diseases were high, and the utilization rates of liver-protective drugs were low. It is necessary to pay more attention to monitoring patients′ liver function, timely administer liver-protective drugs, and optimize liver-protective regimens during the treatment of rheumatic diseases.
8.Current status of surgery for portal hypertension in China: a national multi-center survey analysis
Lei ZHENG ; Haiyang LI ; Jizhou WANG ; Xiao LIANG ; Jian DOU ; Jitao WANG ; Qiang FAN ; Xiong DING ; Wenlong ZHAI ; Yun JIN ; Bo LI ; Songqing HE ; Tao LI ; Jun LIU ; Kui WANG ; Zhiwei LI ; Yongyi ZENG ; Yingmei SHAO ; Yang BU ; Dong SHANG ; Yong MA ; Cheng LOU ; Xinmin YIN ; Jiefeng HE ; Haihong ZHU ; Jincai WU ; Zhidan XU ; Dunzhu BASANG ; Jianguo LU ; Liting ZHANG ; Jianguo ZHAO ; Ling LYU ; Guoyue LYU ; Nim CHOI ; To Tan CHEUNG ; Meng LUO ; Wanguang ZHANG ; Xiaolong QI ; Xiaoping CHEN
Chinese Journal of Organ Transplantation 2023;44(3):152-159
Objective:To explore the current status of surgery for portal hypertension to grasp current status and future development of surgery in China.Methods:This study is jointly sponsored by China Hepatobiliary & Pancreatic Specialist Alliance & Portal Hypertension Alliance in China (CHESS).Comprehensive surveying is conducted for basic domestic situations of surgery for portal hypertension, including case load, surgical approaches, management of postoperative complications, primary effects, existing confusion and obstacles, liver transplantation(LT), laparoscopic procedures and transjugular intrahepatic portosystemic shunt(TIPS), etc.Results:A total of 8 512 cases of portal hypertension surgery are performed at 378 hospitals nationwide in 2021.Splenectomy plus devascularization predominated(53.0%)and laparoscopy accounted for 76.1%.Primary goal is preventing rebleeding(67.0%) and 72.8% of hospitals used preventive anticoagulants after conventional surgery.And 80.7% of teams believe that the formation of postoperative portal vein thrombosis is a surgical dilemma and 65.3% of hospitals practiced both laparoscopy and TIPS.The major reasons for patients with portal hypertension not receiving LT are due to a lack of qualifications for LT(69.3%)and economic factors(69.0%).Conclusions:Surgery is an integral part of management of portal hypertension in China.However, it is imperative to further standardize the grasp of surgical indications, the handling of surgical operation and the management of postoperative complications.Moreover, prospective, multi-center randomized controlled clinical studies should be performed.
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Epidemiological characteristics of a 2019-nCoV outbreak caused by Omicron variant BF.7 in Shenzhen.
Yan Peng CHENG ; Dong Feng KONG ; Jia ZHANG ; Zi Quan LYU ; Zhi Gao CHEN ; Hua Wei XIONG ; Yan LU ; Qing Shan LUO ; Qiu Ying LYU ; Jin ZHAO ; Ying WEN ; Jia WAN ; Fang Fang LU ; Jian Hua LU ; Xuan ZOU ; Zhen ZHANG
Chinese Journal of Epidemiology 2023;44(3):379-385
Objective: To explore the epidemiological characteristic of a COVID-19 outbreak caused by 2019-nCoV Omicron variant BF.7 and other provinces imported in Shenzhen and analyze transmission chains and characteristics. Methods: Field epidemiological survey was conducted to identify the transmission chain, analyze the generation relationship among the cases. The 2019-nCoV nucleic acid positive samples were used for gene sequencing. Results: From 8 to 23 October, 2022, a total of 196 cases of COVID-19 were reported in Shenzhen, all the cases had epidemiological links. In the cases, 100 were men and 96 were women, with a median of age, M (Q1, Q3) was 33(25, 46) years. The outbreak was caused by traverlers initial cases infected with 2019-nCoV who returned to Shenzhen after traveling outside of Guangdong Province.There were four transmission chains, including the transmission in place of residence and neighbourhood, affecting 8 persons, transmission in social activity in the evening on 7 October, affecting 65 persons, transmission in work place on 8 October, affecting 48 persons, and transmission in a building near the work place, affecting 74 persons. The median of the incubation period of the infection, M (Q1, Q3) was 1.44 (1.11, 2.17) days. The incubation period of indoor exposure less than that of the outdoor exposure, M (Q1, Q3) was 1.38 (1.06, 1.84) and 1.95 (1.22, 2.99) days, respcetively (Wald χ2=10.27, P=0.001). With the increase of case generation, the number and probability of gene mutation increased. In the same transmission chain, the proportion of having 1-3 mutation sites was high in the cases in the first generation. Conclusions: The transmission chains were clear in this epidemic. The incubation period of Omicron variant BF.7 infection was shorter, the transmission speed was faster, and the gene mutation rate was higher. It is necessary to conduct prompt response and strict disease control when epidemic occurs.
Male
;
Humans
;
Female
;
SARS-CoV-2
;
COVID-19/epidemiology*
;
Disease Outbreaks
;
Epidemics
;
China/epidemiology*

Result Analysis
Print
Save
E-mail