1.Study on the Effect of Liuwei Dihuang Pills on Regulating the Antigen Cross-Presenting Ability of Dendritic Cells by Interfering with Gap Junctional Communication Function
Yue SONG ; Man-Si XU ; Xue-Ying ZHONG ; Wen-Jing ZHANG ; Xiao-Yi CHEN ; Biao-Yan DU ; Jian-Yong XIAO ; Kun WANG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(1):169-177
Objective To investigate whether Liuwei Dihuang Pills enhances the antigen cross-presenting ability of dendritic cell(DC)by increasing gap junctional intercellular communication(GJIC),and to explore the mechanisms involved.Methods Western Blot and immunofluorescence were used to observe the effects of Liuwei Dihuang Pills-containing serum on the expression and membrane localisation of gap junction protein connexin43(Cx43)in mouse melanoma cells(B16);Calcein-AM/DiI fluorescence tracer assay was used to observe the effects of Liuwei Dihuang Pills-containing serum on the function of GJIC in B16 cells;flow cytometry was used to observe the role of GJIC in the enhancement of DC antigen presenting ability by Liuwei Dihuang Pills-containing serum;and propidium iodide(PI)/Hoechst staining assay was used to observe the immunocidal effect of CD8+ T-lymphocytes.Results Western Blot and immunofluorescence experiments showed that Liuwei Dihuang Pills-containing serum led to the up-regulation of Cx43 expression;fluorescence tracer experiments proved that the GJIC function of B16 cells was significantly enhanced by Liuwei Dihuang Pills-containing serum;flow cytometry analyses showed that the DC antigen-presenting ability was enhanced by Liuwei Dihuang Pills-containing serum;and the results of PI/Hoechst staining showed that the immuno-killing effect of CD8+T-cells was more significant after the intervention of Liuwei Dihuang Pills-containing serum in B16-OVA.Conclusion Liuwei Dihuang Pills improve the GJIC function by up-regulating the Cx43 expression of melanoma cells,and then enhance the cross-presenting ability of DCs thus activating stronger CD8+ T-cell immunocidal responses.
2.Quantitative CT measurement of bone mass density in different regions of the distal clavicle in reconstruction of acromioclavicular joint dislocation
Jian XU ; Wenzhi BI ; Yuncong JI ; Yunkang KANG ; Peiqi MA ; Jialiang WANG ; Zongxi ZHANG ; Fusheng GAN ; Haiyang YU ; Biao GUO
Chinese Journal of Tissue Engineering Research 2024;28(12):1920-1924
BACKGROUND:There is no consensus on the optimal bone tunnel position in the lateral clavicle,which guides coracoclavicular ligament reconstruction.Postoperative complications such as enlargement of the lateral clavicle bone tunnel,bone osteolysis,clavicle fracture,and failure of internal fixation are likely to occur.Bone mass density plays an important role in the strength and stability of endophytic fixation.Regional differences in the bone mass density of the distal clavicle should not be overlooked in the repair and reconstruction of acromioclavicular dislocation.Currently,there are no quantitative clinical studies in humans regarding the bone mass density of the distal clavicle. OBJECTIVE:To measure the magnitude of bone mass density in different regions of the distal clavicle by quantitative CT to provide a reference for surgeons to repair and reconstruct the coracoclavicular ligament. METHODS:101 patients undergoing quantitative CT checking in Fuyang People's Hospital Affiliated to Anhui Medical University from October to December 2022 were enrolled,from which 1 616 samples of subdivisional bone mass density of the distal clavicle were measured.For each of the quantitative CT samples,firstly,the distal clavicle was divided medially to laterally into the following four regions:conical nodal region(region A),inter-nodal region(region B),oblique crest region(region C)and distal clavicular region(region D).Secondly,each region was divided into the first half and the second half to determine eight subdivisions,then setting semiautomatic region of interest(ROI)in each subdivision:(ROI A1,A2,B1,B2,C1,C2,D1,and D2).Thirdly,each quantitative CT scan was transferred to the quantitative CT pro analysis workstation,and cancellous bone mass density was measured in the distal clavicle ROI.Finally,the clavicular cortex was avoided when measuring. RESULTS AND CONCLUSION:(1)There was no statistically significant difference in bone mineral density on the different sides of the shoulder(P>0.05).(2)The analysis of bone mineral density in eight sub-areas of the distal clavicle A1,A2,B1,B2,C1,C2,D1,and D2 showed statistically significant differences(P<0.05).It could be considered that there were differences in bone mineral density in different areas of the distal clavicle.After pairwise comparison,there was no statistically significant difference in bone mineral density between A1 and A2,D1 and D2,A2 and B1(P>0.05),and there was a statistically significant difference in bone mineral density between the other sub-areas(P<0.05).(3)The bone mineral density in the region A2 of the anatomical insertion of the conical ligament was significantly higher than that in the inter-nodular area(region B)(P<0.05).The bone mineral density in the region A1 was higher than that in the region A2,but the difference was not statistically significant(P>0.05).The bone mineral density in the region C1 of the anatomical insertion of the trapezium ligament was higher than that in regions C2,D1 and D2,and the bone mineral density in the inter-nodular area(region B)was significantly higher than that in regions C and D(P<0.05).(4)These results have suggested that there are differences in bone mass density in different regions of the distal clavicle;regional differences in bone mass density in the distal clavicle during repair and reconstruction of acromioclavicular dislocation cannot be ignored.Consideration should be given not only to biomechanical factors but also to the placement of implants or bone tunnels in regions of higher bone mass density,which could improve the strength and stability of implant fixation and reduce the risk of complications such as bone tunnel enlargement,osteolysis,fracture and implant failure.
3.Deep neural networks analysis of 18F-FDG PET imaging in postoperative patients with temporal lobe epilepsy
Huanhua WU ; Shaobo CHEN ; Jingjie SHANG ; Hailing ZHOU ; Biao WU ; Jian GONG ; Xueying LING ; Qiang GUO ; Hao XU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(4):220-224
Objective:To predict the short-term postoperative recurrence status of patients with refractory temporal lobe epilepsy (TLE) by analyzing preoperative 18F-FDG PET images and patients′ clinical characteristics based on deep residual neural network (ResNet). Methods:Retrospective analysis was conducted on preoperative 18F-FDG PET images and clinical data of 220 patients with refractory TLE (132 males and 88 females, age 23.0(20.0, 30.2) years)) in the First Affiliated Hospital of Jinan University between January 2014 and June 2020. ResNet was used to perform high-throughput feature extraction on preprocessed PET images and clinical features, and to perform a postoperative recurrence prediction task for differentiating patients with TLE. The predictive performance of ResNet model was evaluated by ROC curve analysis, and the AUC was compared with that of classical Cox proportional risk model using Delong test. Results:Based on PET images combined with clinical feature training, AUCs of the ResNet in predicting 12-, 24-, and 36-month postoperative recurrence were 0.895±0.073, 0.861±0.058 and 0.754±0.111, respectively, which were 0.717±0.093, 0.697±0.081 and 0.645±0.087 for Cox proportional hazards model respectively ( z values: -3.00, -2.98, -1.09, P values: 0.011, 0.018, 0.310). The ResNet showed best predictive effect for recurrence events within 12 months after surgery. Conclusion:The ResNet model is expected to be used in clinical practice for postoperative follow-up of patients with TLE, helping for risk stratification and individualized management of postoperative patients.
4.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
5.Application of miniprobe endoscopic ultrasound in endoscopic surgery of small-diameter and low-grade rectum neuroendocrine neoplasm
Jian-Jun LI ; Chao-Qiang FAN ; Xin YANG ; Xue PENG ; Hao LIN ; Xu-Biao NIE ; Shi-Ming YANG ; Qiu-Jian QIAO ; Jian-Ying BAI
Journal of Regional Anatomy and Operative Surgery 2024;33(1):59-62
Objective To evaluate the value of miniprobe endoscopic ultrasound(EUS)in guiding endoscopic treatment of small-diameter(maximum diameter less than 1 cm)and low-grade(G1 grade)rectum neuroendocrine neoplasm(R-NEN),and to provide evidence and clues for its clinical application and further research.Methods The clinical data of 85 cases of low-grade(G1 grade)R-NEN with a maximum diameter of less than 1 cm who underwent endoscopic treatment in our center from January 2014 to December 2020 were retrospectively analyzed.The patients were divided into the EUS group(37 cases)and control group(48 cases)according to whether EUS was performed before endoscopic treatment.The positive rate of incision margin,the incidence of complications,the recurrence rate,the hospital stay,the cost of hospitalization and endoscopic therapy were compared between the two groups.Results The positive rate of incision margin in the EUS group was significantly lower than that in control group(P<0.05).There was no significant difference in the incidence of complications,tumor recurrence rate,hospital stay or hospital costs between the two groups(P>0.05).There was statistically significant difference in the endoscopic therapy between the two groups(P<0.05).Conclusion Evaluating the lesion depth of small-diameter and low-grade(G1 grade)R-NEN before surgery by miniprobe EUS and selecting endoscopic surgery according to its results of can significantly reduce the residual risk of resection margin tumors.
6.Efficacy of arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon in the treatment of irreparable massive rotator cuff tears
Yuncong JI ; Jian XU ; Yunkang KANG ; Wenzhi BI ; Wei MA ; Dongqiang YANG ; Honglin CUI ; Pengfei FU ; Yijun LIU ; Jinxiang TIAN ; Biao GUO
Chinese Journal of Trauma 2024;40(3):236-242
Objective:To investigate the efficacy of arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon in the treatment of irreparable massive rotator cuff tears (IMRCT).Methods:A retrospective case series study was performed on 11 IMRCT patients who were admitted to Affiliated Fuyang Hospital of Bengbu Medical University (Fuyang People′s Hospital) from May 2020 to June 2022, including 7 males and 4 females, aged 54-74 years [(62.6±7.3)years]. All the patients were treated with arthroscopic superior capsular reconstruction using composite patch graft combined with tenodesis of the long head of the biceps tendon. The Visual Analogue Scale (VAS), Acromiohumeral Distance (AHD), Constant-Murley score and University of California Los Angeles (UCLA) score and active range of motion of the shoulder joint before, at 6 months after surgery and at the last follow-up were compared. At the last follow-up, the integrity of reconstructed superior capsule and the long head of the biceps tendon was evaluated using MRI of the shoulder joint. Postoperative complications were observed.Results:All the patients were followed up for 13-39 months [16(13, 36)months]. The VAS score, AHD, Constant-Murley score, and UCLA score were 2(2, 3)points, (9.1±1.1)mm, (56.1±5.4)points, and (19.7±2.8)points respectively at 6 months after surgery, which were all significantly improved from those before surgery [6(5, 7)points, (5.1±1.2)mm, (37.9±2.2)points, and (11.8±1.2)points] ( P<0.05). The VAS score, AHD, Constant-Murley score, and UCLA score were 0(0, 1)points, (8.4±0.9)mm, (83.6±3.8)points, and (28.2±2.3)points respectively at the last follow-up, which were all significantly improved from those before surgery ( P<0.05). At the last follow-up, the VAS score or AHD were not significantly improved from those at 6 months after surgery ( P>0.05); Constant-Murley score and UCLA score were both significantly improved from those at 6 months after surgery ( P<0.05). At 6 months after surgery, shoulder active ranges of motion in forward flexion, abduction and external rotation were (134.6±13.5)°, (124.6±18.6)° and 45(40, 50)° respectively, which were all significantly improved compared with those before surgery [(63.2±36.1)°, (65.0±23.1)°, and [30(20, 40)°] ( P<0.05). At the last follow-up, shoulder active ranges of motion in forward flexion, abduction and external rotation were (144.1±12.6)°, (139.6±15.4)° and 60(45, 65)° respectively, which were all significantly improved compared with those before surgery ( P<0.05). There were no significant differences in active range of motion of the shoulder in forward flexion, abduction and external rotation between 6 months after surgery and the last follow-up ( P>0.05). At the last follow-up, MRI revealed integrity of the reconstructed superior joint capsule and the long head of the biceps tendon in 10 patients. One patient developed resorption of the greater tuberosity and 1 showed a partial tear of the supraspinatus tendon at 1 year after surgery. Conclusion:Arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon can relieve shoulder pain, decrease upward displacement of the humerus head, improve the function and range of motion of the shoulder joint, and reduce complications in the treatment of IMRCT.
7.Establishment of an artificial intelligence assisted diagnosis model based on deep learning for recognizing gastric lesions and their locations under gastroscopy in real time
Xian GUO ; Ying-Yang WU ; Ai-Rui JIANG ; Chao-Qiang FAN ; Xue PENG ; Xu-Biao NIE ; Hui LIN ; Jian-Ying BAI
Journal of Regional Anatomy and Operative Surgery 2024;33(10):849-854
Objective To construct an artificial intelligence assisted diagnosis model based on deep learning for dynamically recognizing gastric lesions and their locations under gastroscopy in real time,and to evaluate its ability to detect and recognize gastric lesions and their locations.Methods The gastroscopy videos of 104 patients in our hospital was retrospectively analyzed,and the video frames were manually annotated.The annotated picture frames of lesion category were divided into the training set and the validation set according to the ratio of 8∶2,and the annotated picture frames of location category were divided into the training set and the validation set according to the patient sources at the ratio of 8∶2.These sets were utilized for training and validating the respective models.YoloV4 model was used for the training of lesion recognition,and ResNet152 model was used for the training of location recognition.The accuracy,sensitivity,specificity,positive predictive value,negative predictive value and location recognition accuracy of the auxiliary diagnostic model were evaluated.Results A total of 68 351 image frames were annotated,with 54 872 frames used as the training set,including 41 692 frames for lesion categories and 13 180 frames for location categories.The validation set consisted of 13 479 frames,comprising 10 422 frames for lesion categories and 3 057 frames for location categories.The lesion recognition model achieved an overall accuracy of 98.8%,with a sensitivity of 96.6%,specificity of 99.3%,positive predictive value of 96.3%,and negative predictive value of 99.3% in validation set.Meanwhile,the location recognition model demonstrated an top-5 accuracy of 87.1% .Conclusion The artificial intelligence assisted diagnosis model based on deep learning for real-time dynamic recognition of gastric lesions and their locations under gastroscopy has good ability in lesion detection and location recognition,and has great clinical application prospects.
8.Expert consensus on thrombolytic therapy for ST-segment elevation myocardial infarction
Cardiology Branch of Jiangsu Medical Association ; Cardiology Branch of Jiangsu Medical Doctor Association ; Cardiac Critical Care Specialized Committee of Jiangsu Medical Doctor Association ; Basic & Medication Panel Affiliated to Cardiology Branch of Jiangsu Medical Association ; Chun-Jian LI ; Gen-Shan MA ; Biao XU ; Xiang-Qing KONG
Chinese Journal of Interventional Cardiology 2024;32(7):364-382
Thrombolytic therapy plays a vital role in reperfusion strategy for ST-segment elevation myocardial infarction(STEMI)patients.Previous Chinese expert consensus focused on pre-hospital thrombolysis therapy in STEMI patients was published in 2018 which tremendously promoted pre-hospital thrombolysis therapy.In recent years,plenty of research progress and results of clinical trials have been released in following areas such as STEMI reperfusion strategy,anti-platelet/anti-coagulants therapy,contemporary facilitated percutaneous coronary intervention,and so on.Meanwhile,the COVID-19 pandemic makes timely reperfusion for STEMI patients even more challenging.Therefore,this consensus has been proposed aiming to summarize recent progress in STEMI thrombolysis therapy and to provide practical & evidence-based instructions conforming to national conditions.We hope this consensus will contribute to the emergency management and long-term prognosis of STEMI patients.
9.Effect of anti-PD-1 treatment on the immune microenviron-ment in patients with colorectal cancer
Hao WANG ; Ming ZHOU ; Hao-Yu SHI ; Si-Kun LIU ; Biao SHENG ; Xiao-Xu GE ; Jian WANG
Chinese Journal of Current Advances in General Surgery 2024;27(10):766-772
Objective:To investigate the effects of PD-1 monoclonal antibody therapy on the peripheral and local immune microenvironment of patients with microsatellite instability-high(MSI-H)rectal cancer.Methods:Samples of peripheral blood and tumor biopsy were collected from a patient with MSI-H rectal cancer before and after PD-1 monoclonal antibody treatment.The samples were dissociated into single-cell suspensions using a combination of enzymatic and mechanical methods.Immune-related marker expression on peripheral and tumor-infiltrating im-mune cells was analyzed using single-cell mass cytometry(CyTOF).Results:According to the results of CyTOF analysis,CD45+immune cells in the peripheral blood and tumor tissues were categorized into 39 and 34 cell subsets,respectively,before and after PD-1 monoclonal antibody treatment(the correlation is unclear and ambiguous).After PD-1 monoclonal antibody treatment,differences were observed in the relative abundance of immune cell subsets:B cells significantly decreased in the peripheral blood,while B cells and γδT cells significantly increased in the tumor tissue;neutrophils significantly decreased,and the proportion of CD4+TEM cells in T cell subsets significantly increased,whereas CD4+Treg cells significantly decreased.Additionally,there were differences in the expression of immune-related markers in multiple immune cell subsets in both peripheral blood and tumor tissues,with CCR6 showing a significant increase in expression across all subsets,while ICOS and PD-1 expressions in T cell subsets were significantly reduced(the specific tissues for these cells or factors are unclear).Conclusion:After PD-1 monoclonal antibody treatment in MSI-H rectal cancer,changes occurred in the composition of immune cells and the expression of immune-related markers in both peripheral blood and tumor tissues.This study reveals the dynamic adjustment of the immune microenvironment and provides important evidence for understanding the therapeutic mechanism of PD-1 monoclonal antibodies.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail