1.Research report of living donor kidney harvesting in Bama miniature pigs with six gene modified
Yong XU ; Xiangyu SONG ; Heng’en WANG ; Shujun YANG ; Zhibo JIA ; Hao WEI ; Shengfeng CHEN ; Mengyi CUI ; Yanling REN ; Jiang PENG ; Shengkun SUN
Organ Transplantation 2024;15(2):229-235
Objective To summarize the experience and practical value of living donor kidney harvesting in Bama miniature pigs with six gene modified. Methods The left kidney of Bama miniature pigs with six gene modified was obtained by living donor kidney harvesting technique. First, the ureter was occluded, and then the inferior vena cava and abdominal aorta were freed. During the harvesting process, the ureter, renal vein and renal artery were exposed and freed in sequence. The vascular forceps were used at the abdominal aorta and inferior vena cava, and the renal artery and vein were immediately perfused with 4℃ renal preservation solution, and stored in ice normal saline for subsequent transplantation. Simultaneously, the donor abdominal aorta and inferior vena cava gap were sutured. The operation time, blood loss, warm and cold ischemia time, postoperative complications and the survival of donors and recipients were recorded. Results The left kidney of the genetically modified pig was successfully harvested. Intraoperative bleeding was 5 mL, warm ischemia time was 45 s, and cold ischemia time was 2.5 h. Neither donor nor recipient pig received blood transfusion, and urinary function of the kidney transplanted into the recipient was recovered. The donor survived for more than 8 months after the left kidney was resected. Conclusions Living donor kidney harvesting is safe and reliable in genetically modified pigs. Branch blood vessels could be processed during kidney harvesting, which shortens the process of kidney repair and the time of cold ischemia. Living donor kidney harvesting contributes to subsequent survival of donors and other scientific researches.
2. Research progress of Parkin protein regulating mitochondrial homeostasis through ubiquitination in cardiovascular diseases
Ke-Juan LI ; Jian-Shu CHEN ; Yi-Xin XIE ; Jia-Le BU ; Xiao-Wei ZHANG ; Yong-Nan LI
Chinese Pharmacological Bulletin 2024;40(2):224-228
In addition to providing energy for cells, mitochondria also participate in calcium homeostasis, cell information transfer, cell apoptosis, cell growth and differentiation. Therefore, maintaining mitochondrial homeostasis is very crucial for the body to carry out normal life activities. Ubiquitination, a post-translational modification of proteins, is involved in various physiological and pathological processes of cells by regulating mitochondrial homeostasis. However, the mechanism by which ubiquitination regulates mitochondrial homeostasis has not been summarized, especially the effect of Parkin protein on cardiovascular diseases. In this paper, the specific mechanism of mitochondrial homeostasis regulated by ubiquitination of Parkin protein is discussed, and the influence of mitochondrial homeostasis imbalance on cardiovascular diseases is reviewed, with a view to providing potential therapeutic strategies for the clinical treatment of cardiovascular diseases.
3.A quantitative study on the outcome of patients with breast cancer after autologous breast reconstruction and implant breast reconstruction based on multi-scaleon
Qiu-Ping WU ; Jiong WU ; Ke-Da YU ; A-Yong CAO ; Xiao-Yan HUANG ; Sheng CHEN ; Lei WANG ; Jia-Qin GUAN
Fudan University Journal of Medical Sciences 2024;51(1):81-88,127
Objective To evaluate the patient-reported outcome(PRO)of patients with breast cancer who underwent autologous breast reconstruction and implant breast reconstruction.Methods Patients who underwent breast reconstruction in Shanghai Cancer Center,Fudan University from Jan 2020 to Jun 2021 were selected,including 111 patients who underwent autologous breast reconstruction and 108 patients who underwent implant breast reconstruction.Chinese version Breast-Q2.0 scale,breast cancer specificity scale QLQ-BR23 and EORTC quality of life scale QLQ-C30 were used to investigate the PRO of the two groups 18 months after operation.Results The rate of stage Ⅲ breast cancer in the self-weight construction group was higher than that in the implant reconstruction group(64.9%vs.44.4%,P<0.001).The preoperative neoadjuvant therapy and postoperative radiotherapy in the autologous reconstruction group were higher than those in the implant reconstruction group(P<0.001).Postoperative chemotherapy and endocrine therapy in the autologous reconstruction group were lower than those in the implant reconstruction group(P<0.001).The study based on Breast-Q scale showed that the breast satisfaction of autologous reconstruction group was higher than that of implant reconstruction(59.28±17.20 vs.54.94±14.48,P<0.05).The study based on QLQ-BR23 showed that the self-weight construction group was higher than the implant reconstruction group in the field of arm symptoms(20.02±20.80 vs.12.65±16.18,P<0.05).The study based on QLQ-C30 scale showed that there was no significant difference in all functional areas and symptom areas of patients.There was no significant difference in the number and time of social regression between the two groups.Conclusion Breast reconstruction can improve the PRO of breast cancer patients,and oncology factors will affect the choice of breast reconstruction.Patients with autologous breast reconstruction are more satisfied with breast appearance,but upper limb symptoms such as swelling and pain are more obvious than implant reconstruction,which is related to the higher proportion of axillary lymph node dissection in patients with autologous reconstruction.There is no significant difference in quality of life and social regression between the two groups.
4.Study on The Mechanism of Sinomenine Hydrochloride Induced Fibroblast Apoptosis in Rabbits with Adhesive Knee Ankylosis
Xin-Ju HOU ; Hong-Feng LEI ; Yong CHEN ; Fu-Xi LI ; Jing-Ning SUN ; Jia-Ming LIU ; Hong-Mei MA
Progress in Biochemistry and Biophysics 2024;51(4):959-968
ObjectiveThis study aimed to observe the impact of sinomenine hydrochloride on the proliferation of fibroblasts and the mRNA expression of related genes in knee joint adhesion and contracture in rabbits. Additionally, we sought to explore its potential mechanisms in combating knee joint adhesion and contracture. MethodsFibroblasts were cultured in vitro, and experimental groups with varying concentrations of sinomenine hydrochloride were established alongside a control group. Cell proliferation was assessed using the CCK-8 assay. Changes in the mRNA expression of fibroblast-related genes following sinomenine hydrochloride treatment were evaluated using RT-qPCR. The impact of the drug on serum levels of inflammatory cytokines was determined using the ELISA method, and the expression of related proteins was assessed using Western blot. ResultsSinomenine hydrochloride was found to inhibit fibroblast viability, with viability decreasing as the concentration of sinomenine hydrochloride increased. The effects of sinomenine hydrochloride in all experimental groups were highly significant (P<0.05). At the mRNA expression level, compared to the control group, sinomenine hydrochloride led to a significant downregulation of inflammatory cytokines in all groups (P<0.05). Additionally, the expression levels of apoptosis-related proteins significantly increased, while Bcl-2 mRNA expression decreased (P<0.05). The mRNA expression levels of the PI3K/mTOR/AKT3 signaling pathway also decreased (P<0.05). At the protein expression level, in comparison to the control group, the levels of inflammatory cytokines IL-6, IL-8, IL-1β, and TGF-β were significantly downregulated in the middle and high-dose sinomenine hydrochloride groups (P<0.05). The expression levels of cleaved-PARP, cleaved caspase-3/7, and Bax increased and were positively correlated with the dose, while the expression levels of the anti-apoptotic protein Bcl-2 and the PI3K/AKT3/mTOR signaling pathway were negatively correlated with the dose. Sinomenine hydrochloride exhibited a significant inhibitory effect on the viability of rabbit knee joint fibroblasts, which may be associated with the downregulation of inflammatory cytokines IL-6, IL-8, and IL-1β, promotion of apoptosis-related proteins cleaved-PARP, cleaved caspase-3/7, and Bax, suppression of Bcl-2 expression, and inhibition of gene expression in the downstream PI3K/AKT3/mTOR signaling pathway. ConclusionSinomenine hydrochloride can inhibit the inflammatory response of fibroblasts in adhesive knee joints and accelerate fibroblast apoptosis. This mechanism may offer a novel approach to improving and treating knee joint adhesion.
5.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.
6.A Comprehensive Study of the Association between LEPR Gene rs1137101 Variant and Risk of Digestive System Cancers
Qiong Wei HU ; Guang Wei ZHOU ; Wei Guang ZHOU ; Xi Jia LIAO ; Xing Jia SHI ; FengYang XIE ; Heng Shou LI ; Yong WANG ; Hong Xian FENG ; Li Xiu GU ; Feng Bi CHEN
Biomedical and Environmental Sciences 2024;37(5):445-456
Objective The leptin receptor,encoded by the LEPR gene,is involved in tumorigenesis.A potential functional variant of LEPR,rs1137101(Gln223Arg),has been extensively investigated for its contribution to the risk of digestive system(DS)cancers,but results remain conflicting rather than conclusive.Here,we performed a case-control study and subsequent meta-analysis to examine the association between rs1137101 and DS cancer risk. Methods A total of 1,727 patients with cancer(gastric/liver/colorectal:460/480/787)and 800 healthy controls were recruited.Genotyping of rs1137101 was conducted using a polymerase chain reaction-restriction fragment length polymorphism(PCR-RFLP)assay and confirmed using Sanger sequencing.Twenty-four eligible studies were included in the meta-analysis. Results After Bonferroni correction,the case-control study revealed that rs1137101 was significantly associated with the risk of liver cancer in the Hubei Chinese population.The meta-analysis suggested that rs1137101 is significantly associated with the risk of overall DS,gastric,and liver cancer in the Chinese population. Conclusion The LEPR rs1137101 variant may be a genetic biomarker for susceptibility to DS cancers(especially liver and gastric cancer)in the Chinese population.
7.Long-term efficacy of balloon-assisted endplate augmentation combined with transforaminal pedicle screw fixation in the treatment of thoracolumbar burst fractures
Qiyu JIA ; Yu YU ; Lin WANG ; Wangen GUO ; Xiaodong CHEN ; Yong XUAN
Chinese Journal of Surgery 2024;62(3):194-201
Objectives:To investigate the long-term efficacy of balloon assisted endplate reduction with vertebral augmentation combined with pedicle screw fixation in the treatment of thoracolumbar burst fractures, and to compare the clinical efficacy of calcium sulfate cement (CSC) and calcium phosphate cement(CPC).Methods:This study is a retrospective cohort study.The clinical data of 39 patients with thoracolumbar burst fractures admitted to Hefei Hospital Affiliated to Anhui Medical University from November 2013 to December 2017 were retrospectively analyzed.All patients were treated with pedicle screw reduction and fixation of the injured vertebra,balloon-assisted reduction of the collapsed endplate of the injured vertebra,and artificial bone vertebral body augmentation,and the follow-up time was >5 years.There were 24 males and 15 females,aged (42.9±13.3) years (range: 29 to 56 years).According to the Frankel spinal nerve dysfunction grading standard, there were 4 cases of grade C, 7 cases of grade D and 28 cases of grade E. There were 21 cases of CSC augmentation(CSC group) and 18 cases of CPC augmentation (CPC group). X-ray and CT were performed at 1 week, 1-, 2-, 5-year after surgery and at the last follow-up, and the imaging indicators were measured, including the injured vertebra anterior edge height ratio,the injured vertebra middle height ratio,the injured vertebra wedge angle,and the sagittal plane Cobb angle. The pain visual analogue scale (VAS) and the Oswestry disability index (ODI) was used for functional evaluation, nervous function was evaluated according to the Frankel spinal nerve dysfunction grading standard.Independent sample t test was used for inter-group comparison, and paired sample t test and repeated measure ANOVA were used for intra-group comparison. Results:All operative procedures were successfully completed, no spinal nerve function damage occurred. The postoperative imaging indexes of the patients were significantly improved compared with those before surgery (all P<0.01). The follow-up time of patients was (6.7±2.8)years (range: 5 to 9 years). Among the 11 patients with symptoms of neurological impairment before surgery, 9 patients completely recovered at the last follow-up, and 2 patients recovered from Frankel grade C to D. There were no significant differences in imaging indexes between the first week after surgery and the last follow-up in the CPC group (all P>0.05), while there were significant differences in imaging indexes between the CSC group and the last follow-up (all P<0.05). CPC group was superior to CSC group in frontal height ratio, middle height ratio, wedge angle variation and sagittal Cobb angle correction loss at 2 year, 5 year after surgery and the last follow-up, with statistical significance (all P<0.05). At the last follow-up, there were no differences in VAS and ODI between the two groups (all P>0.05). After absorption of CSC in the filling area, a hardened zone was formed around the area, and the central cavity remained without bone tissue filling. CPC absorption was very slow, and the CPC group was still filled satisfactorily at the last follow-up. Conclusions:Balloon assisted endplate reduction and vertebral augmentation combined with pedicle screw fixation through the injured vertebra have good long-term efficacy in the treatment of thoracolumbar burst fractures. Compared with CSC, CPC vertebral augmentation can better maintain the shape and spinal sequence of the injured vertebra in the long term, and can effectively reduce the collapse of the space above the injured vertebra.
8.Chairside digital design and manufacturing method for children's band and loop space maintainers
Qingzhao QIN ; Jia HU ; Xiaoxian CHEN ; Bingqing SHI ; Zixiang GAO ; Yujia ZHU ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2024;42(2):234-241
Objective This study proposes a chairside digital design and manufacturing method for band and loop space maintainers and preliminarily validates its clinical feasibility.Methods Clinical cases of 10 children requiring space maintenance caused by premature loss of primary teeth were collected.Intraoral scan data of the affected children were also collected to establish digital models of the missing teeth.Using a pediatric band and loop space maintainer de-sign software developed by our research team,a rapid personalized design of band and loop structures was achieved,and a digital model of an integrated band and loop space maintainer was ultimately generated.A chairside space maintainer was manufactured through metal computer numerical control machining for the experimental group,whereas metal 3D printing in the dental laboratory was used for the control group.A model fitting assessment was conducted for the space maintainers of both groups,and senior pediatric dental experts were invited to evaluate the clinical feasibility of the space maintainers with regard to fit and stability using the visual analogue scale scoring system.Statistical analysis was also performed.Results The time spent in designing and manufacturing the 10 space maintainers of the experimental group was all less than 1 h.Statistical analysis of expert ratings showed that the experimental group outperformed the control group with regard to fit and stability.Both types of space maintainers met clinical requirements.Conclusion The chairside digital design and manufacturing method for pediatric band and loop space maintainers proposed in this study can achieve same-day fitting of space maintainers at the first appointment,demonstrating good clinical feasibility and significant potential for clinical application.
9.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
10.Review of gallium-based liquid metals for medical applications
Pei-Kai ZHAO ; Yu-Long WANG ; Yong-Kang ZHAN ; Jia-Xing QI ; Xu-Yi CHEN
Chinese Medical Equipment Journal 2024;45(11):97-102
The gallium-based liquid metals were introduced in terms of the advantages when applied in medical field,application status in medical imaging,drug delivery,antibiosis and tumor therapy and cutting-edge application in flexible e-skin,wearable sensor and flexible medical device.The deficiencies of the gallium-based liquid metals in durability,potential toxicity,high cost of preparation and difficulty of process control were analyzed when applied in medical fields.The future development directions of the gallium-based liquid metals were pointed out.[Chinese Medical Equipment Journal,2024,45(11):97-102]

Result Analysis
Print
Save
E-mail