1.Plasma miRNA testing in the differential diagnosis of very early-stage hepatocellular carcinoma: a multicenter real-world study
Jie HU ; Ying XU ; Ao HUANG ; Lei YU ; Zheng WANG ; Xiaoying WANG ; Xinrong YANG ; Zhenbin DING ; Qinghai YE ; Yinghong SHI ; Shuangjian QIU ; Huichuan SUN ; Qiang GAO ; Jia FAN ; Jian ZHOU
Chinese Journal of Clinical Medicine 2025;32(3):350-354
Objective To explore the application of plasma 7 microRNA (miR7) testing in the differential diagnosis of very early-stage hepatocellular carcinoma (HCC). Methods This study is a multicenter real-world study. Patients with single hepatic lesion (maximum diameter≤2 cm) who underwent plasma miR7 testing at Zhongshan Hospital, Fudan University, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Anhui Provincial Hospital, and Peking University People’s Hospital between January 2019 and December 2024 were retrospectively enrolled. Patients were divided into very early-stage HCC group and non-HCC group, and the clinical pathological characteristics of the two groups were compared. The value of plasma miR7 levels, alpha-fetoprotein (AFP), and des-gamma-carboxy prothrombin (DCP) in the differential diagnosis of very early-stage HCC was evaluated using receiver operating characteristic (ROC) curves and area under the curve (AUC). In patients with both negative AFP and DCP (AFP<20 ng/mL, DCP<40 mAU/mL), the diagnostic value of plasma miR7 for very early-stage HCC was analyzed. Results A total of 64 528 patients from 4 hospitals underwent miR7 testing, and 1 682 were finally included, of which 1 073 were diagnosed with very early-stage HCC and 609 were diagnosed with non-HCC. The positive rate of miR7 in HCC patients was significantly higher than that in non-HCC patients (67.9% vs 24.3%, P<0.001). ROC curves showed that the AUCs for miR7, AFP, and DCP in distinguishing HCC patients from the non-HCC individuals were 0.718, 0.682, and 0.642, respectively. The sensitivities were 67.85%, 43.71%, and 44.45%, and the specificities were 75.70%, 92.78%, and 83.91%, respectively. The pairwise comparison of AUCs showed that the diagnostic efficacy of plasma miR7 detection was significantly better than that of AFP or DCP (P<0.05). Although its specificity was slightly lower than AFP and DCP, the sensitivity was significantly higher. Among patients negative for both AFP and DCP, miR7 maintained an AUC of 0.728 for diagnosing very early-stage HCC, with 67.82% sensitivity and 77.73% specificity. Conclusions Plasma miR7 testing is a potential molecular marker with high sensitivity and specificity for the differential diagnosis of small hepatic nodules. In patients with very early-stage HCC lacking effective molecular markers (negative for both AFP and DCP), miR7 can serve as a novel and effective molecular marker to assist diagnosis.
2.Reliability and validity of assessment tools of Brief ICF Core Sets for Arthroplasty of Knee Osteoarthritis in Peri-operative Period
Boyang YU ; Yanyan YANG ; Ao MA ; Tao LI ; Xiaoxie LIU ; Zhengyang LI ; Yajing DUAN ; Jiaqi LIU ; Yuxiao XIE ; Cui WANG ; Zhen HUANG ; Lining ZHANG ; Xinyi LIU ; Zishan JIA ; Mouwang ZHOU
Chinese Journal of Rehabilitation Theory and Practice 2024;30(9):1053-1059
Objective To investigate the reliability and validity of the assessment tools of Brief ICF Core Sets for Arthroplasty of Knee Osteoarthritis in Perioperative Period(ICSAKOPP). Methods From May,2022 to April,2023,320 patients undergoing knee arthroplasty were selected in Peking University Third Hospital,China-Japan Friendship Hospital,Peking University First Hospital and Chinese PLA General Hospital.Trained assessors used Brief ICSAKOPP to evaluate all enrolled patients before arthroplasty,three days(±one day)after arthroplasty,three weeks(±one week)after arthroplasty,and three months(±one month)after ar-throplasty.Western Ontario and McMaster Universities Osteoarthritis Index(WOMAC)scores were recorded at the same time.Five professionals were asked to score all the items of Brief ICSAKOPP,and the content validity index(CVI)was caculated. Results A total of 64 cases were dropped down.CVI of all the items of the Brief ICSAKOPP were above 0.8,with a av-erage CVI of the scale of 0.938.The Cronbach's α coefficient of the Brief ICSAKOPP was 0.813.There was a moderate correlation(r=0.681,P<0.001)between the overall Brief ICSAKOPP and WOMAC scores,as well as body functional dimension score(r=0.668,P<0.001)and activities and participation dimension score(r=0.657,P<0.001). Conclusion Brief ICSAKOPP is good in content validity,internal consistency reliability and criterion validity.
3.Research Progress of Gas Raman Spectroscopy Detection Technology
Qi-Fan ZHOU ; Yu LU ; Ao LI ; Chang LIU ; Jia-He ZHANG ; Xi YANG ; Yan HUANG ; Xiang-Wei ZHAO
Chinese Journal of Analytical Chemistry 2024;52(7):925-936
Highly sensitive multiple detection and accurate identification of gases are of great importance in the fields of public safety,environmental protection,health diagnosis and industrial production.However,the traditional means of gas detection have many shortcomings such as low sensitivity,long time-consuming,bulky equipment,cumbersome processes and expensive costs.In recent years,Raman spectroscopy has become a hotspot in the field of gas detection because of its fast,sensitive and non-destructive characteristics,and has been more and more closely combined with artificial intelligence.This paper reviews the progress of Raman spectroscopy in gas detection in recent years,including conventional Raman spectroscopy and enhanced Raman spectroscopy,and also introduces the integration of artificial intelligence algorithms in gas Raman detection technology,and discusses the future development of gas Raman detection.
4.New perspectives on the therapeutic potential of quercetin in non-communicable diseases:Targeting Nrf2 to counteract oxidative stress and inflammation
Zhang LI ; Xu LI-YUE ; Tang FEI ; Liu DONG ; Zhao XIAO-LAN ; Zhang JING-NAN ; Xia JIA ; Wu JIAO-JIAO ; Yang YU ; Peng CHENG ; Ao HUI
Journal of Pharmaceutical Analysis 2024;14(6):805-822
Non-communicable diseases(NCDs),including cardiovascular diseases,cancer,metabolic diseases,and skeletal diseases,pose significant challenges to public health worldwide.The complex pathogenesis of these diseases is closely linked to oxidative stress and inflammatory damage.Nuclear factor erythroid 2-related factor 2(Nrf2),a critical transcription factor,plays an important role in regulating antioxidant and anti-inflammatory responses to protect the cells from oxidative damage and inflammation-mediated injury.Therefore,Nrf2-targeting therapies hold promise for preventing and treating NCDs.Quercetin(Que)is a widely available flavonoid that has significant antioxidant and anti-inflammatory properties.It modulates the Nrf2 signaling pathway to ameliorate oxidative stress and inflammation.Que modulates mitochondrial function,apoptosis,autophagy,and cell damage biomarkers to regulate oxidative stress and inflammation,highlighting its efficacy as a therapeutic agent against NCDs.Here,we discussed,for the first time,the close association between NCD pathogenesis and the Nrf2 signaling pathway,involved in neurodegenerative diseases(NDDs),cardiovascular disease,cancers,organ damage,and bone damage.Furthermore,we reviewed the availability,pharmacokinetics,pharmaceutics,and therapeutic applica-tions of Que in treating NCDs.In addition,we focused on the challenges and prospects for its clinical use.Que represents a promising candidate for the treatment of NCDs due to its Nrf2-targeting properties.
5.Construction and application of the " pyramid" hierarchical discipline evaluation system in a hospital
Guoyue LYU ; Bin LIU ; Feng WEI ; Yanchun LI ; Xue WANG ; Jia′ao YU
Chinese Journal of Hospital Administration 2024;40(6):405-409
Accurately assessing and positioning the current development status of disciplines can help hospitals formulate targeted disciplinary development strategies and achieve disciplinary development goals. In 2022, a large tertiary public hospital established a discipline-demand-oriented " pyramid" hierarchical discipline evaluation system based on Maslow′s need-hierarchy theory. The discipline evaluation system set six levels of evaluation indicators from low to high, including medical quality and safety, department operation, sub specialty construction, scientific and educational achievements, platform construction, and talent cultivation(including 6 primary indicators, 21 secondary indicators, and 44 tertiary indicators). By applying the evaluation system and providing feedback on the evaluation results in the form of " disciplinary diagnostic reports" and " disciplinary evaluation conferences, " the hospital′s discipline construction had been improved at six levels. From 2022 to 2023, the hospital added five national clinical key specialties; The number of sub major construction disciplines increased from 18 in 2021 to 61 in 2023, and patient satisfaction increased from 94.64% to 96.25%. This evaluation system could objectively reflect the level of discipline development, lead the high-quality development of disciplines, and provide references for other public hospitals to promote discipline development.
6.Preliminary evaluation of the trueness of 5 chairside 3D facial scanning techniques.
Ao Nan WEN ; Wei LIU ; Da Wei LIU ; Yu Jia ZHU ; Ning XIAO ; Yong WANG ; Yi Jiao ZHAO
Journal of Peking University(Health Sciences) 2023;55(2):343-350
OBJECTIVE:
To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment.
METHODS:
The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated.
RESULTS:
DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points.
CONCLUSION
Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.
Imaging, Three-Dimensional
;
Software
;
Models, Dental
7.Rapid identification and differential markers of Curcumae Radix decoction pieces of different sources based on Heracles Neo ultra-fast gas phase electronic nose.
Ming-Xuan LI ; Yu-Wen QIN ; Yu LI ; Jiu-Ba ZHANG ; De JI ; Ling-Yun QU ; Jing-Wen GONG ; Ao-Meng JIA ; Chun-Qin MAO ; Tu-Lin LU
China Journal of Chinese Materia Medica 2023;48(6):1518-1525
Since Curcumae Radix decoction pieces have multiple sources, it is difficult to distinguish depending on traditional cha-racters, and the mixed use of multi-source Curcumae Radix will affect its clinical efficacy. Heracles Neo ultra-fast gas phase electronic nose was used in this study to quickly identify and analyze the odor components of 40 batches of Curcumae Radix samples from Sichuan, Zhejiang, and Guangxi. Based on the odor fingerprints established for Curcumae Radix decoction pieces of multiple sources, the odor components was identified and analyzed, and the chromatographic peaks were processed and analyzed to establish a rapid identification method. Principal component analysis(PCA), discriminant factor analysis(DFA), and soft independent modeling cluster analysis(SIMCA) were constructed for verification. At the same time, one-way analysis of variance(ANOVA) combined with variable importance in projection(VIP) was employed to screen out the odor components with P<0.05 and VIP>1, and 13 odor components such as β-caryophyllene and limonene were hypothesized as the odor differential markers of Curcumae Radix decoction pieces of diffe-rent sources. The results showed that Heracles Neo ultra-fast gas phase electronic nose can well analyze the odor characteristics and rapidly and accurately discriminate Curcumae Radix decoction pieces of different sources. It can be applied to the quality control(e.g., online detection) in the production of Curcumae Radix decoction pieces. This study provides a new method and idea for the rapid identification and quality control of Curcumae Radix decoction pieces.
Drugs, Chinese Herbal/analysis*
;
Electronic Nose
;
China
;
Plant Roots/chemistry*
;
Limonene/analysis*
;
Chromatography, High Pressure Liquid
8.Automatic determination of mandibular landmarks based on three-dimensional mandibular average model.
Zi Xiang GAO ; Yong WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yun ZHANG ; Jing WANG ; Yi Jiao ZHAO
Journal of Peking University(Health Sciences) 2023;55(1):174-180
OBJECTIVE:
To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.
METHODS:
The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.
RESULTS:
The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.
CONCLUSION
The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.
Humans
;
Imaging, Three-Dimensional/methods*
;
Mandible/diagnostic imaging*
;
Software
;
Algorithms
;
Anatomic Landmarks/anatomy & histology*
9.Preliminary study on three-dimensional morphological reconstruction method for external nose defect based on three-dimensional face template.
Ao Nan WEN ; Yong WANG ; Hong Qiang YE ; Zi Xiang GAO ; Yu Jia ZHU ; Qing Zhap QIN ; Hui Zhen HU ; Yun Song LIU ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(5):414-421
Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.
10.The design method of the digital sequential tooth-sectioning guide for the extraction of mandibular impacted third molars.
Zi Xiang GAO ; Yi Jiao ZHAO ; Yu Jia ZHU ; Ning XIAO ; Ao Nan WEN ; Wei ZHOU ; Bo Chun MAO ; Yun ZHANG ; Wei QI ; Yong WANG
Chinese Journal of Stomatology 2023;58(5):435-441
Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.

Result Analysis
Print
Save
E-mail