1.A novel TNKS/USP25 inhibitor blocks the Wnt pathway to overcome multi-drug resistance in TNKS-overexpressing colorectal cancer.
Hongrui ZHU ; Yamin GAO ; Liyun LIU ; Mengyu TAO ; Xiao LIN ; Yijia CHENG ; Yaoyao SHEN ; Haitao XUE ; Li GUAN ; Huimin ZHAO ; Li LIU ; Shuping WANG ; Fan YANG ; Yongjun ZHOU ; Hongze LIAO ; Fan SUN ; Houwen LIN
Acta Pharmaceutica Sinica B 2024;14(1):207-222
		                        		
		                        			
		                        			Modulating Tankyrases (TNKS), interactions with USP25 to promote TNKS degradation, rather than inhibiting their enzymatic activities, is emerging as an alternative/specific approach to inhibit the Wnt/β-catenin pathway. Here, we identified UAT-B, a novel neoantimycin analog isolated from Streptomyces conglobatus, as a small-molecule inhibitor of TNKS-USP25 protein-protein interaction (PPI) to overcome multi-drug resistance in colorectal cancer (CRC). The disruption of TNKS-USP25 complex formation by UAT-B led to a significant decrease in TNKS levels, triggering cell apoptosis through modulation of the Wnt/β-catenin pathway. Importantly, UAT-B successfully inhibited the CRC cells growth that harbored high TNKS levels, as demonstrated in various in vitro and in vivo studies utilizing cell line-based and patient-derived xenografts, as well as APCmin/+ spontaneous CRC models. Collectively, these findings suggest that targeting the TNKS-USP25 PPI using a small-molecule inhibitor represents a compelling therapeutic strategy for CRC treatment, and UAT-B emerges as a promising candidate for further preclinical and clinical investigations.
		                        		
		                        		
		                        		
		                        	
2.Research and evaluation on development model of hospice care at home and abroad
Guangwei JI ; Mingfei ZHOU ; Yuxin ZHOU ; Jinqiu ZHANG ; Junxia YANG ; Zhi ZHOU
The Journal of Practical Medicine 2024;40(7):877-886
		                        		
		                        			
		                        			Palliative and hospice care is an emerging medical care model for the development of modern medicine,and its emergence is not only a sign of social demand and the development of human civilization,but also an important manifestation of the change in the modern medical model.Hospice care is the final stage of palliative care,which is of great significance for the end-of-life treatment of incurable diseases.Palliative and hospice care has become an independent discipline in many countries,and its development has been rapid.However,the develop-ment of hospice and palliative care in China is not satisfactory,and the lack of money and human resources are the main reasons limiting its development.Many scholars have carried out a lot of useful practices in this regard.How to explore a road of hospice and palliative care development suitable for China′s national conditions is an urgent problem to be solved.By reviewing domestic and foreign literature,this paper summarizes the development mode and payment method of palliative and hospice care abroad,identifies the challenges encountered in the practice of hospice care in China,and draws on the development experience of palliative and hospice care in foreign countries.We aimed to identify pain points and difficulties faced in developing palliative and hospice care in China,so as to better serve patients at the end of life,gradually promote the concept of palliative and hospice care,and contribute to the sustainable development of palliative and hospice care in China.
		                        		
		                        		
		                        		
		                        	
3.Longitudinal extrauterine growth restriction in extremely preterm infants: current status and prediction model
Xiaofang HUANG ; Qi FENG ; Shuaijun LI ; Xiuying TIAN ; Yong JI ; Ying ZHOU ; Bo TIAN ; Yuemei LI ; Wei GUO ; Shufen ZHAI ; Haiying HE ; Xia LIU ; Rongxiu ZHENG ; Shasha FAN ; Li MA ; Hongyun WANG ; Xiaoying WANG ; Shanyamei HUANG ; Jinyu LI ; Hua XIE ; Xiaoxiang LI ; Pingping ZHANG ; Hua MEI ; Yanju HU ; Ming YANG ; Lu CHEN ; Yajing LI ; Xiaohong GU ; Shengshun QUE ; Xiaoxian YAN ; Haijuan WANG ; Lixia SUN ; Liang ZHANG ; Jiuye GUO
Chinese Journal of Neonatology 2024;39(3):136-144
		                        		
		                        			
		                        			Objective:To study the current status of longitudinal extrauterine growth restriction (EUGR) in extremely preterm infants (EPIs) and to develop a prediction model based on clinical data from multiple NICUs.Methods:From January 2017 to December 2018, EPIs admitted to 32 NICUs in North China were retrospectively studied. Their general conditions, nutritional support, complications during hospitalization and weight changes were reviewed. Weight loss between birth and discharge > 1SD was defined as longitudinal EUGR. The EPIs were assigned into longitudinal EUGR group and non-EUGR group and their nutritional support and weight changes were compared. The EPIs were randomly assigned into the training dataset and the validation dataset with a ratio of 7∶3. Univariate Cox regression analysis and multiple regression analysis were used in the training dataset to select the independent predictive factors. The best-fitting Nomogram model predicting longitudinal EUGR was established based on Akaike Information Criterion. The model was evaluated for discrimination efficacy, calibration and clinical decision curve analysis.Results:A total of 436 EPIs were included in this study, with a mean gestational age of (26.9±0.9) weeks and a birth weight of (989±171) g. The incidence of longitudinal EUGR was 82.3%(359/436). Seven variables (birth weight Z-score, weight loss, weight growth velocity, the proportion of breast milk ≥75% within 3 d before discharge, invasive mechanical ventilation ≥7 d, maternal antenatal corticosteroids use and bronchopulmonary dysplasia) were selected to establish the prediction model. The area under the receiver operating characteristic curve of the training dataset and the validation dataset were 0.870 (95% CI 0.820-0.920) and 0.879 (95% CI 0.815-0.942), suggesting good discrimination efficacy. The calibration curve indicated a good fit of the model ( P>0.05). The decision curve analysis showed positive net benefits at all thresholds. Conclusions:Currently, EPIs have a high incidence of longitudinal EUGR. The prediction model is helpful for early identification and intervention for EPIs with higher risks of longitudinal EUGR. It is necessary to expand the sample size and conduct prospective studies to optimize and validate the prediction model in the future.
		                        		
		                        		
		                        		
		                        	
4.Evaluation of the accuracy of optical surface imaging system in non-coplanar radiotherapy using orthogonal kV/MV images
Shoupeng LIU ; Jialu LAI ; Linghui ZHOU ; Erbu MAO ; Ji ZHOU ; Yang HUANG ; Denghong LIU ; Renming ZHONG
Chinese Journal of Radiation Oncology 2024;33(1):40-48
		                        		
		                        			
		                        			Objective:To evaluate the accuracy of the optical surface imaging system (OSI) using stereotactic radiosurgery (SRS) algorithm in single-center non-coplanar treatment of multiple brain metastases.Methods:Data of phantom and 15 patients with multiple brain metastases who underwent single-center non-coplanar radiotherapy in West China Hospital of Sichuan University from February to April 2022 were retrospectively analyzed. kV/MV and OSI imaging were used for imaging of the patients and phantoms under the same non-coplanar couch angle, respectively. The accuracy of OSI imaging of the phantoms and patients was evaluated using kV/MV imaging as reference image. The difference between the OSI and kV/MV systems is defined as accuracy, and the percentage of the absolute difference ≤1.00 mm in the translational direction or ≤0.50° in the rotational direction is defined as the threshold pass rate. Origin software was used to draw radar maps and Bland-Altman plots for statistical analysis.Results:When OSI images were used for the phantom imaging, the average differences in six-dimensional directions of lateral, long, vertical, rotational, roll and pitch were 0.03 mm, -0.09 mm, -0.27 mm, 0.04°, 0.17° and -0.19°, respectively. The maximum values were -2.20 mm, -2.30 mm, -1.20 mm, 0.60°, -1.00°, and -1.00°, respectively. When OSI system was utilized for the imaging of 15 patients, the average differences in six-dimensional directions were 0.44 mm, 0.16 mm, -0.20 mm, -0.11°, 0.10°, and -0.12°, respectively. The maximum values were -1.80 mm, 2.00 mm, 0.90 mm, -0.90°, -0.70°, and 0.80°, respectively. The translational errors mainly occurred in the lateral and long directions. The qualified rates of the threshold values of the phantoms and patients were 77% and 75% in the lateral direction, 82% and 89% in the long direction, respectively. In addition, 57% and 56% of patients met the threshold conditions of ±1.00 mm and ±0.50° in the six-dimensional directions, respectively.Conclusions:The OSI system using new SRS algorithm cannot meet the high accuracy requirements of single-center non-coplanar radiotherapy for multiple brain metastasis, especially in the lateral and long directions. It is not recommended for non-coplanar image guidance.
		                        		
		                        		
		                        		
		                        	
5.National bloodstream infection bacterial resistance surveillance report (2022) : Gram-negative bacteria
Zhiying LIU ; Yunbo CHEN ; Jinru JI ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(1):42-57
		                        		
		                        			
		                        			Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of national bloodstream infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:During the study period,9 035 strains of Gram-negative bacteria were collected from 51 hospitals,of which 7 895(87.4%)were Enterobacteriaceae and 1 140(12.6%)were non-fermenting bacteria. The top 5 bacterial species were Escherichia coli( n=4 510,49.9%), Klebsiella pneumoniae( n=2 340,25.9%), Pseudomonas aeruginosa( n=534,5.9%), Acinetobacter baumannii complex( n=405,4.5%)and Enterobacter cloacae( n=327,3.6%). The ESBLs-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus spp. were 47.1%(2 095/4 452),21.0%(427/2 033)and 41.1%(58/141),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(58/4 510)and 13.1%(307/2 340);62.1%(36/58)and 9.8%(30/307)of CREC and CRKP were resistant to ceftazidime/avibactam combination,respectively. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 59.5%(241/405),while less than 5% of Acinetobacter baumannii complex was resistant to tigecycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 18.4%(98/534). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of main Gram-negative bacteria resistance among different regions,with statistically significant differences in the prevalence of CRKP and CRPA( χ2=20.489 and 20.252, P<0.001). The prevalence of CREC,CRKP,CRPA,CRAB,ESBLs-producing Escherichia coli and Klebsiella pneumoniae were higher in provinicial hospitals than those in municipal hospitals( χ2=11.953,81.183,10.404,5.915,12.415 and 6.459, P<0.01 or <0.05),while the prevalence of CRPA was higher in economically developed regions(per capita GDP ≥ 92 059 Yuan)than that in economically less-developed regions(per capita GDP <92 059 Yuan)( χ2=6.240, P=0.012). Conclusions:The proportion of Gram-negative bacteria in bloodstream infections shows an increasing trend,and Escherichia coli is ranked in the top,while the trend of CRKP decreases continuously with time. Decreasing trends are noted in ESBLs-producing Escherichia coli and Klebsiella pneumoniae. Low prevalence of carbapenem resistance in Escherichia coli and high prevalence in CRAB complex have been observed. The composition ratio and antibacterial spectrum of bloodstream infections in different regions of China are slightly different,and the proportion of main drug resistant bacteria in provincial hospitals is higher than those in municipal hospitals.
		                        		
		                        		
		                        		
		                        	
6.Mechanism of action and clinical research progress of iguratimod in connective tissue diseases
Xiaorong YANG ; Shuhong ZHOU ; Lijiang GUO ; Ying CHEN ; Yingying JI ; Lijie XU
China Pharmacy 2024;35(5):629-634
		                        		
		                        			
		                        			As a new type of immunosuppressant,iguratimod can mediate the anti-inflammatory signaling pathway by inhibiting the proliferation of inflammatory cells and reducing the release of inflammatory cytokines, and play the role of anti-inflammatory. It can affect the proliferation of immune cells and the expression of immune factors,reduce the production and deposition of immune complexes in the body,and play the role of immune regulation. It can regulate bone metabolism by mediating signaling pathways such as Wnt/β-catenin,Toll-like receptor 4/nuclear factor-κB and osteoprotegerin/nuclear factor-κB receptor activating factor ligand, and play a role in bone protection. It can inhibit pulmonary fibrosis by inhibiting the expression of transforming growth factor β1/ Smad2/3 signaling pathway,tumor necrosis factor-α,interleukin-1,interleukin-6,matrix metalloproteinase-9 and other inflammatory cytokines in lung tissue,and inhibiting the expression of collagen and fibronectin. Its efficacy and safety have been confirmed in the clinical application of rheumatoid arthritis and primary Sjogren syndrome and included in the diagnosis and treatment of the disease. It has also shown good efficacy in the clinical application of other connective tissue diseases such as systemic lupus erythematosus and ankylosing spondylitis,and no obvious safety risks have been found.
		                        		
		                        		
		                        		
		                        	
7.Treatment strategies of cytoreductive surgery plus intraperitoneal hyperthermic chemotherapy for gastric cancer with peritoneal metastasis: a systematic review
Chenghao JI ; Linpo ZHOU ; Yebin YANG ; Junqiang HU ; Haoran WEI ; Fanhe DONG ; Yuqiang SHAN ; Wencheng KONG
Chinese Journal of Gastrointestinal Surgery 2024;27(7):740-748
		                        		
		                        			
		                        			Peritoneal metastasis in gastric cancer is associated with rapid disease progression. Hyperthermic intraoperative peritoneal chemotherapy (HIPEC) done immediately after cytoreductive surgery (CRS) has become an important treatment for peritoneal metastasis in gastric cancer patients. However, different treatment options for HIPEC exist with potential influence on survival rates and prognosis in patients, exist. These treatment options include open or closed abdomen technique, perfusion solution, number of catheters, temperature, duration, and drug regimens. This paper aims to provide more evidence on standardization of HIPEC treatment options and technologies by systematically reviewing different drug regimens and technical approaches. The study included 2 randomized controlled trials, 3 phase I/II clinical trials, 2 prospective cohort studies, and 34 retrospective cohort studies, involving 1511 patients. The most common HIPEC option is to dissolve 50-75 mg/m 2 of Cisplatin and 30-40 mg/m 2 of Mitomycin C in 3-4 L saline solution at 42-43℃. After gastrointestinal anastomosis, 2-3 catheters are used in the HIPEC system with a perfusion flow rate of 500 ml/min. The duration is 60-90 minutes. Anastomotic leakage was low in studies where HIPEC was performed after gastrointestinal anastomosis. The utilization of open HIPEC and a two-drug regimen resulted in improved overall survival rates. The future development of HIPEC aims to enhance tumor-specific therapy by optimizing various aspects, such as identifying the safest and most effective chemotherapy regimens, refining patient selection criteria, and improving perioperative care.
		                        		
		                        		
		                        		
		                        	
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
9.Application of polyetheretherketone rod semi-rigid pedicle screw internal fixation in lumbar non-fusion surgery
Tao LIU ; Xing YU ; Jian-Bin GUAN ; Yong-Dong YANG ; He ZHAO ; Ji-Zhou YANG ; Yi QU ; Feng-Xian WANG ; Ding-Yan ZHAO ; Zi-Yi ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(7):676-683
		                        		
		                        			
		                        			Objective To investigate the effect of Polyetheretherketone(PEEK)rod semi-rigid pedicle screw fixation sys-tem in lumbar spine non-fusion surgery.Methods A total of 74 patients with tow-level lumbar degenerative diseases who un-derwent surgery from March 2017 to December 2019 were divided into PEEK rod group and titanium rod group.In the PEEK rod group,there were 34 patients,including 13 males and 21 females,aged from 51 to 79 years old with an average of(62.4±6.8)years old;There were 1 patient of L1-L3 segments,7 patients of L2-L4 segments,20 patients of L3-L5 segments and 6 pa-tients of L4-S1 segments.In the titanium rod group,there were 40 patients,including 17 males and 23 females,aged from 52 to 81 years old with an average of(65.2±7.3)years old;There were 3 patient of L1-L3 segments,11 patients of L2-L4 segments,19 patients of L3-L5 segments and 7 patients of L4-S1 segments.The general conditions of operation,such as operation time,intraoperative blood loss,postoperative drainage was recorded.The visual analogue scale(VAS)for low back pain and Os-westry disability index(ODI)were compared in preoperatively and postoperatively(3 months,12 months and last follow-up)between two groups.The change of range of motion(ROM)was observed by flexion and extension x-ray of lumbar Results All patients successfully completed the operation.The follow-up time ranged from 22 to 34 months with an average of(26.8±5.6)months.The operative time(142.2±44.7)min and intraoperative blood loss(166.5±67.4)ml in PEEK group were lower than those in titanium group[(160.7±57.3)min、(212.8±85.4)ml](P<0.05).There was no significant differences in postoperative drainage between the two groups(P>0.05).At the final follow-up visit,in PEEK group and titanium group VAS of low back pain[(0.8±0.4)points vs(1.0±0.5)points],VAS for leg pain[(0.7±0.4)points vs(0.8±0.5)points]and ODI[(9.8±1.6)%vs(12.1±1.5)%]were compared with preoperative[(5.8±1.1)points vs(6.0±1.1)points],[(7.2±1.7)points vs(7.0±1.6)points],[(68.5±8.9)%vs(66.3±8.2)%]were significantly different(P<0.05).There was no significant difference in VAS scores between the two groups at each postoperative time point(P>0.05).At 3 months after surgery,there was no difference in ODI between the two groups(P>0.05).There were significant differences in ODI between PEEK group and titanium rod group at 12 months[(15.5±2.1)%vs(18.4±2.4)%]and at the last follow-up[(9.8±1.6)%vs(12.1±1.5)%](P<0.05).The total range of motion(ROM)of lumbar decreased in both groups after surgery.At 12 months after surgery and the last follow-up,the PEEK group compared with the titanium rod group,the total range of motion of lumbar was statistically significant(P<0.05).The range of motion(ROM)of the fixed segments decreased in both groups after surgery.The ROM of the fixed segments in PEEK group decreased from(9.5±4.6)° to(4.1±1.9)° at the last follow-up(P<0.05),which in the titanium rod group was de-creased from(9.8±4.3)°to(0.9±0.5)° at the last follow-up(P<0.05).The range of motion(ROM)of upper adjacent segment increased in both groups,there was statistical significance in the ROM of upper adjacent segment between the two groups at 12 months after surgery and the last follow-up,(P<0.05).There was no screw loosening and broken rods in both groups during the follow-up period.Conclusion The PEEK rod semi-rigid pedicle screw internal fixation system used in lumbar non-fusion surgery can retain part of the mobility of the fixed segment,showing comparable short-term clinical efficacy to titanium rod fu-sion.PEEK rod semi-rigid pedicle screw internal fixation system is a feasible choice for the treatment of lumbar spine degener-ative diseases,and its long-term efficacy needs further follow-up observation.
		                        		
		                        		
		                        		
		                        	
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail