1.Rapid Determination of 32 Kinds of Veterinary Drug Residues in Eggs Using Modified QuEChERS Based on Reduced Graphene Oxide-coated Melamine Sponge by Ultra-High Liquid Chromatography-Tandem Mass Spectrometry
Xu XU ; Jia LYU ; Lan-Rui YANG ; Zhu-Chen HOU ; Bao-Cheng JI ; Yan-Hong BAI
Chinese Journal of Analytical Chemistry 2024;52(1):121-129,中插38-中插43
		                        		
		                        			
		                        			A rapid analytical method for simultaneous determination of 32 kinds of multi-residue veterinary drugs in eggs was developed using a modified QuEChERS technique based on a reduced graphene oxide-coated melamine sponge(r-GO@MeS)by ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The influences of graphene oxide(GO)concentrations,sponge dosages,and purification modes on drug recoveries were investigated during the purification process.The optimal purification conditions involved using a GO concentration of 0.5 mg/mL,a sponge dosage of 6.0 cm3/mL,and a dynamic purification mode of 5 extrusion cycles.Separation was achieved using an Agilent Eclipse Plus C18 RRHD column(100 mm×2.1 mm,1.8 μm),and quantitative analysis was performed by the external standard method using an electrospray ionization source(ESI)in multiple reaction monitoring(MRM)mode.The results showed that all 32 kinds of veterinary drugs exhibited good linear correlation with coefficients greater than 0.999,and matrix effects(MEs)ranging from?7.8%to 18.9%.The limits of detection(LODs)and quantification(LOQs)ranged from 0.2 to 10.2 μg/kg and from 0.6 to 28.0 μg/kg,respectively.The recoveries for the three spiked levels were in the range of 66.5%?117.5%,with intra-day and inter-day precision(Relative standard deviation)below 13.3%and 16.3%,respectively.The synthetic r-GO@MeS exhibited efficient matrix purification without the need of high-speed centrifugation or strong magnetic field assistance.This significantly shorted the sample pretreatment time and improved the convenience of the matrix purification process.Combined with UPLC-MS/MS,the method was suitable for the rapid determination of multi-residue veterinary drugs in eggs.
		                        		
		                        		
		                        		
		                        	
2.Study on the influence of electronic medical record linkage time node reminder system on emergency treatment time node and prognosis of severe trauma patients
Lifen CHEN ; Huibin PAN ; Li LING ; Zhaohui JI ; Yun BAO
China Modern Doctor 2024;62(22):1-4
		                        		
		                        			
		                        			Objective To clarify the clinical application effect of electronic medical record linkage time node reminder system(hereinafter referred to as reminder system)in trauma center.Methods A total of 90 patients with severe trauma admitted to the Trauma Center of Huzhou First People's Hospital from June 2022 to March 2023 were selected,and 45 patients admitted from June to October 2022 were included in control group for routine pre-hospital in-hospital treatment.Forty-five patients with severe trauma admitted from November 2022 to March 2023 were included in experimental group,and reminder system was implemented to guide the treatment process.The indexes of medical quality control,emergency black hole procedure time and patient outcome were compared between two groups.Results Bedside FAST ultrasound examination time,CT scan completion time,emergency room stay time,nursing waiting time,make diagnosis and treatment plan and surgical talk time,and travel transport time of patients in experimental group were significantly shorter than those in control group(P<0.05).There were no significant differences in the first tranexamic acid administration time,completion time of damage control treatment,length of stay in intensive care unit,duration of invasive mechanical ventilation and success rate of treatment between two groups(P>0.05).Conclusion The application of reminder system is helpful to strengthen the cooperation of medical care,shorten the unnecessary waiting time for treatment,and accelerate the time node transformation in the process of severe trauma treatment.
		                        		
		                        		
		                        		
		                        	
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
4.Three-dimensional finite element analysis of lumbar disc herniation under different body positions
Ben-Jing YIN ; Yu LU ; Fu-Tao JI ; Rong-Neng QIU ; Yuan-Yang XIE ; Ge CHEN ; Tian-Li XU ; Chao-Yu BAO ; Ju-Bao LI
China Journal of Orthopaedics and Traumatology 2024;37(6):599-604
		                        		
		                        			
		                        			Objective To campare biomechanical effects of different postural compression techniques on three-dimensional model of lumbar disc herniation(LDH)by finite element analysis.Methods Lumbar CT image of a 48-year-old female patient with LDH(heighted 163 cm,weighted 53 kg)was collected.Mimics 20.0,Geomagic Studio,Solidwords and other software were used to establish three-dimensional finite element model of LDH on L4,5 segments.Compression techniques under horizon-tal position,30° forward bending and 10° backward extension were simulated respectively.After applying the pressure,the ef-fects of compression techniques under different positions on stress,strain and displacement of various tissues of intervertebral disc and nerve root were observed.Results L4,5 segment finite element model was successfully established,and the model was validated.When compression manipulation was performed on the horizontal position,30° flexion and 10° extension,the annular stress were 0.732,5.929,1.286 MPa,the nucleus pulposus stress were 0.190,1.527,0.295 MPa,and the annular strain were 0.097,0.922 and 0.424,the strain sizes of nucleus pulposus were 0.153,1.222 and 0.282,respectively.The overall displace-ment distance of intervertebral disc on Y direction were-3.707,-18.990,-4.171 mm,and displacement distance of nerve root on Y direction were+7.836,+5.341,+3.859 mm,respectively.The relative displacement distances of nerve root and interverte-bral disc on Y direction were 11.543,24.331 and 8.030 mm,respectively.Conclusion Compression manipulation could make herniated intervertebral disc produce contraction and retraction trend,by increasing the distance between herniated interverte-bral disc and nerve root,to reduce symptoms of nerve compression,to achieve purpose of treatment for patients with LDH,in which the compression manipulation is more effective when the forward flexion is 30°.
		                        		
		                        		
		                        		
		                        	
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
6.Analyse the risk factors for producing anti-HLA antibodies in patients with hematological diseases
Kai JI ; Lan WANG ; Luyao CHEN ; Xiaojing BAO ; Xiaoni YUAN ; Xiaojin WU ; Jun HE
Chinese Journal of Blood Transfusion 2024;37(2):165-173
		                        		
		                        			
		                        			【Objective】 To explore the risk factors for the production of anti-HLA antibodies in patients with hematological diseases before hematopoietic stemcell transplantation. 【Methods】 The results and clinical data of 1 008 patients with hematological diseases in our hospital who underwent anti-HLA antibody testing were collected by using Luminex technology platform before transplantation from 2016 to 2018 for statistical analysis. 【Results】 The total positive rate of anti-HLA antibodies in 1 008 patients was 24.08%. Multivariate analysis showed that independent risk factors associated with the production of anti-HLA antibodies included age≥30 years old(P=0.046, OR1.467, 95%CI1.007-2.136), time from disease diagnosis to antibody testing≥41 days(P=0.000, OR1.830, 95%CI1.306-2.565), initial platelet count<20×109/L(P=0.020, OR1.543, 95%CI1.072-2.220), prior pregnancy(P=0.000, OR5.187, 95%CI3.689-7.293), transfusions before admission(P=0.001, OR1.762, 95%CI1.257-2.470)and total platelet transfusion volumes after admission≥30 U(P=0.000, OR2.352, 95%CI1.638-3.376). Age ≥30 years old(P=0.023, OR=1.839, 95%CI1.088-3.108)and prior pregnancy(P=0.042, OR=5.258, 95%CI1.062-26.038)are associated with the production of anti-HLA class Ⅰ and class Ⅱ antibodies, respectively. The time from disease diagnosis to antibody testing≥41 days(P=0.000, OR=2.873, 95%CI1.612-5.119), initial platelet count<20×109/L(P=0.008, OR=2.164, 95%CI1.225-3.822), prior pregnancy(P=0.002, OR=6.734, 95%CI1.993-22.751), transfusions before admission(P=0.001, OR=2.746, 95%CI1.531-4.925)and total platelet transfusion volumes after admission>30 U(P=0.006, OR=3.459, 95%CI1.416-8.451)are associated with the production of anti-HLA class Ⅰ and Ⅱ antibodies. 【Conclusion】 Older age, longer course of disease, lower PLT count, history of pregnancy and blood transfusion, and higher total amount of PLT transfusion are risk factors which affect the production of anti-HLA antibodies.Therefore, it is advisable to test for anti-HLA antibodies according to the situation before transplantation, which is of great value in guiding donor selection, monitoring antibody changes and improving transplant prognosis.
		                        		
		                        		
		                        		
		                        	
7.The expression of CD24 antigen in multiple myeloma patients and its predictive value after induction therapy
Mengru LIU ; Bin CHU ; Yuan CHEN ; Mengzhen WANG ; Minqiu LU ; Shan GAO ; Lei SHI ; Qiuqing XIANG ; Lijuan FANG ; Qi YAN ; Na JI ; Kai SUN ; Li BAO
Chinese Journal of Laboratory Medicine 2024;47(10):1178-1185
		                        		
		                        			
		                        			Objective:This study analyzed the expression of CD24 antigen on bone marrow plasma cells (BMPC) of patients with multiple myeloma (MM) and the predictive value of induction therapy.Methods:This clinical observational study utilized 258 MM patients samples treated at the Hematology Department of Beijing Jishuitan Hospital who met the inclusion criteria in the Department of Hematology, Capital Medical University, from August 12th, 2022 to February 1st, 2024. According to the different stages of the disease, patients were divided into three groups: 78 cases of Newly Diagnosed Multiple Myeloma(NDMM) (42 males and 36 females, aged 62±11), 56 cases of the relapse refractory group (34 males and 22 females, aged 64±9), and 124 cases of the disease remission group (68 males and 56 females, aged 62±10). Multiparameter flow cytometry (MFC) was used to detect the expression level of CD24 antigen on BMPC and the relationship between CD24 and MM disease status. The clinical data and test results of 78 NDMM patients at initial diagnosis were retrospectively analyzed, including gender, age, MFC detection of the positive expression rate of antigens (CD19, CD20, CD24, CD27, CD56), the results of efficacy evaluation after induction therapy, ISS staging, R-ISS staging, blood hemoglobin, β2-microglobulin, human serum albumin, serum creatinine, lactate dehydrogenas, correction of calcium, BMPC ratio, and the results of FISH. The patients were divided into a deep remission group [including complete remission (CR) and very good partial remission (VGPR)] with 43 cases and a non-deep remission group (non CR and VGPR) with 17 cases according to the difference of antigen positive expression rate after induction therapy. The differences of antigen expression on BMPC between the two groups were compared. Binary logistic regression was used to analyze the relationship between the expression of each antigen and the efficacy after induction therapy in patients, and the results showed that CD24 was more correlated with the achievement of deep remission after induction therapy than other antigens. Therefore, taking the positive expression rate of CD24 in NDMM patients at the initial diagnosis and deep remission after induction therapy as the research objects, the predictive value of CD24 for NDMM patients reaching deep remission after induction therapy was analyzed by using receiver operating characteristic curve (ROC), and the optimal cutoff value was obtained. NDMM was divided into two groups according to the cut-off value, and the differences between the two groups in clinical baseline data and prognostic indicators were compared.Results:The positive rates of plasma cell CD24 expression in the NDMM group, the relapse refractory group and the disease remission group were 2.18 (95% CI 0.08-81.85)%, 3.81 (95% CI 0.10-64.56)%, 8.74 (95% CI 0.79-95.55)% respectively. Compared with the disease remission group, the NDMM and relapse refractory group was lower ( Z=-7.889, -5.282, respectively, P<0.001). Univariate analysis showed that there was a significant difference in the positive expression rate of CD24 at initial diagnosis between the deep remission group and the non-deep remission group ( Z=-3.265, P<0.001), while there was no significant difference in CD19 ( Z=-0.271, P=0.787), CD20 ( Z=-0.205, P=0.837), CD27 ( Z=-0.582, P=0.560), and CD56 ( Z=-0.328, P=0.743) between the two groups. Binary logistic regression analysis showed that compared with other antigens [CD19 ( OR=1.045, 95% CI 0.975-1.120, P=0.217), CD20 ( OR=1.000, 95% CI 0.971-1.030, P=0.976), CD27 ( OR=0.997, 95% CI 0.977-1.016, P=0.734), CD56 ( OR=1.006, 95% CI 0.990-1.006, P=0.449)], the expression of CD24 ( OR=0.423, 95% CI 0.990-1.006, P=0.449) on BMPC in NDMM patients was most closely related to the achievement of deep remission was achieved after induction therapy. The lower the proportion of CD24 at the initial diagnosis was, the lower the probability of achieving deep remission after induction therapy was. The area under the curve (AUC) of CD24 in predicting deep remission after induction therapy was 0.772 (95% CI 0.655-0.889, P=0.001), with a sensitivity of 60.50%, a specificity of 85.00%, and the optimal critical value was 2.21%. Compared with the group with plasma CD24 positive rate>2.21%, the group with plasma CD24 positive rate<2.21% had a higher proportion of male (39.47%vs 65.00%, χ2=5.092, P=0.024), ISS stagingⅢ (41.67% vs 58.33%, χ2=6.175, P=0.046), β2 microglobulin (3.19 mg/L vs 4.14 mg/L, Z=-2.257, P=0.024), and BMPC [(8.672±1.827)% vs (19.530±3.188)%, t=-2.963, P=0.004] detected by MFC, and the differences were statistically significant. Conclusions:The low positive rate of plasma cell CD24 is closely related to the higher tumor burden and the worse disease status of MM patients. In addition, the positive expression rate of CD24 is at initial diagnosis can predict the efficacy achieved after induction therapy, and the lower positive rate of CD24 is, the worse the efficacy achieved after induction therapy. At the same time, MFC detection of CD24 is convenient and efficient in the evaluation and prediction of MM.
		                        		
		                        		
		                        		
		                        	
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
9.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
		                        		
		                        			 Objective:
		                        			This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. 
		                        		
		                        			Methods:
		                        			Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. 
		                        		
		                        			Results:
		                        			In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. 
		                        		
		                        			Conclusion
		                        			In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail