1.High-Dose Rifampicin for 3 Months after Culture Conversion for Drug-Susceptible Pulmonary Tuberculosis
Nakwon KWAK ; Joong-Yub KIM ; Hyung-Jun KIM ; Byoung-Soo KWON ; Jae Ho LEE ; Jeongha MOK ; Yong-Soo KWON ; Young Ae KANG ; Youngmok PARK ; Ji Yeon LEE ; Doosoo JEON ; Jung-Kyu LEE ; Jeong Seong YANG ; Jake WHANG ; Kyung Jong KIM ; Young Ran KIM ; Minkyoung CHEON ; Jiwon PARK ; Seokyung HAHN ; Jae-Joon YIM
Tuberculosis and Respiratory Diseases 2025;88(1):170-180
Background:
This study aimed to determine whether a shorter high-dose rifampicin regimen is non-inferior to the standard 6-month tuberculosis regimen.
Methods:
This multicenter, randomized, open-label, non-inferiority trial enrolled participants with respiratory specimen positivity by Xpert MTB/RIF assay or Mycobacterium tuberculosis culture without rifampicin-resistance. Participants were randomized at 1:1 to the investigational or control group. The investigational group received high-dose rifampicin (30 mg/kg/day), isoniazid, and pyrazinamide until culture conversion, followed by high-dose rifampicin and isoniazid for 12 weeks. The control group received the standard 6-month regimen. The primary outcome was the rate of unfavorable outcomes at 18 months post-randomization. The non-inferiority margin was set at <6% difference in unfavorable outcomes rates. The study is registered with ClinicalTrials.gov (NCT04485156)
Results:
Between 4 November 2020 and 3 January 2022, 76 participants were enrolled. Of these, 58 were included in the modified intention-to-treat analysis. Unfavorable outcomes occurred in 10 (31.3%) of 32 in the control group and 10 (38.5%) of 26 in the investigational group. The difference was 7.2% (95% confidence interval, ∞ to 31.9%), failing to prove non-inferiority. Serious adverse events and grade 3 or higher adverse events did not differ between the groups.
Conclusion
The shorter high-dose rifampicin regimen failed to demonstrate non-inferiority but had an acceptable safety profile.
2.Impact of Distal Fusion Level on Sacroiliac Joint Degenerative Change Following Adolescent Idiopathic Scoliosis Surgery
Sang-Ho KIM ; Jae-Won SHIN ; Seong-Hwan MOON ; Kyung-Soo SUK ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; Joong Won HA ; Yung PARK ; Hak-Sun KIM
Yonsei Medical Journal 2025;66(2):103-110
Purpose:
To evaluate the relationship between distal fusion level in correction and fusion surgery for adolescent idiopathic scoliosis (AIS) and radiologic changes in the sacroiliac (SI) joint.
Materials and Methods:
This retrospective cohort study evaluated patients who underwent correction and fusion for AIS between 2005 and 2017 with at least 5 years of follow-up. We categorized patients into two groups: Group 1 (distal fusion above L2, 74 patients) and Group 2 (distal fusion at L3 and below, 52 patients). Radiologic parameters and SI joint changes were evaluated on plain radiographs obtained from preoperative to 5 years postoperatively. We also investigated other risk factors for SI joint change.
Results:
Analysis of demographic factors revealed no significant difference between the two groups. There was a significant difference in the incidence of SI joint change between Group 1 (5 patients, 6.75%) and Group 2 (18 patients, 34.61%), with Group 2 showing a faster increase in incidence according to the Kaplan-Meier method (p<0.0001). Preoperative lumbar lordosis (LL) and ΔLL had a significant relationship with SI joint changes [preoperative LL, hazard ratio (HR)=0.77, 95% confidence interval (CI)=0.64– 0.93, p=0.008; ΔLL, HR=0.79, 95% CI=0.67–0.95, p=0.01).
Conclusion
After AIS surgery, patients who had fusion to the lower lumbar vertebrae (L3 or L4) experienced a higher incidence and faster progression of degenerative changes in the SI joint. Low preoperative LL and inadequate correction of LL during the operation were also risk factors for SI joint degeneration.
3.Full mouth rehabilitation of patient with excessively worn dentition from multiple factors: a case report
Jiwon HA ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(2):154-163
Excessive wear of the teeth, which causes functional, aesthetic problems, or sensitivity symptoms, is referred to as pathological wear. If this leads to the collapse of occlusion, extensive restoration is necessary to restore function and aesthetics.When restoring pathologically worn dentition, it is essential to identify the cause of the wear before determining treatment plan to get a favorable prognosis. In this case, a patient exhibited severe tooth wear with decreased vertical dimension and clinical, radiographic examination, and medical history indicated the pathological wear caused by a combination of factors. Consequently, full-mouth rehabilitation was indicated and the vertical occlusal height was determined considering the appropriate restorative space. Based on the causes of the wear, the restoration method, materials, and occlusal pattern were selected and successfully restored to normal occlusal state through full-mouth rehabilitation with zirconia full-veneered crowns.
4.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
5.Complete mouth rehabilitation using jaw motion tracking and facial scan: a case report
Jongmin KIM ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(1):50-61
The occlusal collapse resulting from loss of posterior tooth support and attrition necessitates treatment aimed at restoring normal function and aesthetics.Particularly in cases where there is insufficient space for restoration, full mouth rehabilitation accompanied by increased vertical dimension is necessary. This case report presents a complete mouth rehabilitation of a patient with inadequate anterior restoration space due to loss of posterior tooth support, utilizing guided implant surgery, facial scan, virtual articulator, and jaw motion tracker.
6.High-Dose Rifampicin for 3 Months after Culture Conversion for Drug-Susceptible Pulmonary Tuberculosis
Nakwon KWAK ; Joong-Yub KIM ; Hyung-Jun KIM ; Byoung-Soo KWON ; Jae Ho LEE ; Jeongha MOK ; Yong-Soo KWON ; Young Ae KANG ; Youngmok PARK ; Ji Yeon LEE ; Doosoo JEON ; Jung-Kyu LEE ; Jeong Seong YANG ; Jake WHANG ; Kyung Jong KIM ; Young Ran KIM ; Minkyoung CHEON ; Jiwon PARK ; Seokyung HAHN ; Jae-Joon YIM
Tuberculosis and Respiratory Diseases 2025;88(1):170-180
Background:
This study aimed to determine whether a shorter high-dose rifampicin regimen is non-inferior to the standard 6-month tuberculosis regimen.
Methods:
This multicenter, randomized, open-label, non-inferiority trial enrolled participants with respiratory specimen positivity by Xpert MTB/RIF assay or Mycobacterium tuberculosis culture without rifampicin-resistance. Participants were randomized at 1:1 to the investigational or control group. The investigational group received high-dose rifampicin (30 mg/kg/day), isoniazid, and pyrazinamide until culture conversion, followed by high-dose rifampicin and isoniazid for 12 weeks. The control group received the standard 6-month regimen. The primary outcome was the rate of unfavorable outcomes at 18 months post-randomization. The non-inferiority margin was set at <6% difference in unfavorable outcomes rates. The study is registered with ClinicalTrials.gov (NCT04485156)
Results:
Between 4 November 2020 and 3 January 2022, 76 participants were enrolled. Of these, 58 were included in the modified intention-to-treat analysis. Unfavorable outcomes occurred in 10 (31.3%) of 32 in the control group and 10 (38.5%) of 26 in the investigational group. The difference was 7.2% (95% confidence interval, ∞ to 31.9%), failing to prove non-inferiority. Serious adverse events and grade 3 or higher adverse events did not differ between the groups.
Conclusion
The shorter high-dose rifampicin regimen failed to demonstrate non-inferiority but had an acceptable safety profile.
7.Impact of Distal Fusion Level on Sacroiliac Joint Degenerative Change Following Adolescent Idiopathic Scoliosis Surgery
Sang-Ho KIM ; Jae-Won SHIN ; Seong-Hwan MOON ; Kyung-Soo SUK ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; Joong Won HA ; Yung PARK ; Hak-Sun KIM
Yonsei Medical Journal 2025;66(2):103-110
Purpose:
To evaluate the relationship between distal fusion level in correction and fusion surgery for adolescent idiopathic scoliosis (AIS) and radiologic changes in the sacroiliac (SI) joint.
Materials and Methods:
This retrospective cohort study evaluated patients who underwent correction and fusion for AIS between 2005 and 2017 with at least 5 years of follow-up. We categorized patients into two groups: Group 1 (distal fusion above L2, 74 patients) and Group 2 (distal fusion at L3 and below, 52 patients). Radiologic parameters and SI joint changes were evaluated on plain radiographs obtained from preoperative to 5 years postoperatively. We also investigated other risk factors for SI joint change.
Results:
Analysis of demographic factors revealed no significant difference between the two groups. There was a significant difference in the incidence of SI joint change between Group 1 (5 patients, 6.75%) and Group 2 (18 patients, 34.61%), with Group 2 showing a faster increase in incidence according to the Kaplan-Meier method (p<0.0001). Preoperative lumbar lordosis (LL) and ΔLL had a significant relationship with SI joint changes [preoperative LL, hazard ratio (HR)=0.77, 95% confidence interval (CI)=0.64– 0.93, p=0.008; ΔLL, HR=0.79, 95% CI=0.67–0.95, p=0.01).
Conclusion
After AIS surgery, patients who had fusion to the lower lumbar vertebrae (L3 or L4) experienced a higher incidence and faster progression of degenerative changes in the SI joint. Low preoperative LL and inadequate correction of LL during the operation were also risk factors for SI joint degeneration.
8.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
10.Elevated Circulating Sclerostin Levels in Frail Older Adults: Implications beyond Bone Health
Ji Yeon BAEK ; Seong Hee AHN ; Il-Young JANG ; Hee-Won JUNG ; Eunhye JI ; So Jeong PARK ; Yunju JO ; Eunju LEE ; Dongryeol RYU ; Seongbin HONG ; Beom-Jun KIM
Endocrinology and Metabolism 2025;40(1):73-81
Background:
Sclerostin, initially recognized for its pivotal role in bone metabolism, has gained attention for its multifaceted impact on overall human health. However, its influence on frailty—a condition that best reflects biological age—has not been thoroughly investigated.
Methods:
We collected blood samples from 244 older adults who underwent comprehensive geriatric assessments. Sclerostin levels were quantified using an enzyme-linked immunosorbent assay. Frailty was assessed using two validated approaches: the phenotypic model by Fried and the deficit accumulation frailty index (FI) by Rockwood.
Results:
After controlling for sex, age, and body mass index, we found that serum sclerostin levels were significantly elevated in frail individuals compared to their robust counterparts (P<0.001). There was a positive correlation between serum sclerostin concentrations and the FI (P<0.001). Each standard deviation increase in serum sclerostin was associated with an odds ratio of 1.87 for frailty (P=0.003). Moreover, participants in the highest quartile of sclerostin levels had a significantly higher FI and a 9.91-fold increased odds of frailty compared to those in the lowest quartile (P=0.003 and P=0.039, respectively).
Conclusion
These findings, which for the first time explore the association between circulating sclerostin levels and frailty, have significant clinical implications, positioning sclerostin as one of potential blood-based biomarkers for frailty that captures the comprehensive physical, mental, and social aspects of the elderly, extending beyond its traditional role in bone metabolism.

Result Analysis
Print
Save
E-mail