1.Effect of Combined Treatment of Metoclopramide With Platinum-Based Drugs on Apoptosis in AMC-HN4 Cells
Jong Won PARK ; Seon Min WOO ; Jong In JEONG ; Jae Man LEE ; Ji Won LEE ; Dong Eun KIM ; Taeg Kyu KWON
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):113-120
Background and Objectives:
Metoclopramide is an antagonist of dopamine D2 receptor and is capable of alleviating chemotherapy-induced nausea and vomiting. However, its underlying mechanisms and function in improving the efficiency of chemotherapy are not fully understood. In this study, we investigated the sensitizing effect of metoclopramide on the platinum-based drugs-mediated apoptosis in human head and neck cancer cells.Subjects and Method Apoptosis was analyzed using a cell-based cytometer. The protein expression and messenger ribonucleic acid (mRNA) levels were assessed by Western blotting and real-time polymerase chain reaction, respectively.
Results:
Metoclopramide sensitized the platinum-based drug (cisplatin and oxaliplatin)-mediated apoptosis in AMC-HN4 cells, but not in normal cells. Mechanistically, we found that metoclopramide decreased Mcl-1 protein expression through post-translational regulation. Moreover, the overexpression of Mcl-1 prevented apoptosis by combined treatment of metoclopramide and platinum-based drugs.
Conclusion
Metoclopramide induced proteasome-mediated Mcl-1 downregulation, resulting in increased sensitivity to platinum-based drugs.
2.Training of Radiology Residents in Korea
Jei Hee LEE ; Ji Seon PARK ; A Leum LEE ; Yun-Jung LIM ; Seung Eun JUNG
Korean Journal of Radiology 2025;26(4):291-293
3.Imaging Findings of Complications of New Anticancer Drugs
Ji Sung JANG ; Hyo Jung PARK ; Chong Hyun SUH ; Sang Eun WON ; Eun Seong LEE ; Nari KIM ; Do-Wan LEE ; Kyung Won KIM
Korean Journal of Radiology 2025;26(2):156-168
The anticancer drugs have evolved significantly, spanning molecular targeted therapeutics (MTTs), immune checkpoint inhibitors (ICIs), chimeric antigen receptor T-cell (CAR-T) therapy, and antibody-drug conjugates (ADCs). Complications associated with these drugs vary widely based on their mechanisms of action. MTTs that target angiogenesis can often lead to complications related to ischemia or endothelial damage across various organs, whereas non-anti-angiogenic MTTs present unique complications derived from their specific pharmacological actions. ICIs are predominantly associated with immunerelated adverse events, such as pneumonitis, colitis, hepatitis, thyroid disorders, hypophysitis, and sarcoid-like reactions. CAR-T therapy causes unique and severe complications including cytokine release syndrome and immune effector cell-associated neurotoxicity syndrome. ADCs tend to cause complications associated with cytotoxic payloads. A comprehensive understanding of these drug-specific toxicities, particularly using medical imaging, is essential for providing optimal patient care. Based on this knowledge, radiologists can play a pivotal role in multidisciplinary teams. Therefore, radiologists must stay up-to-date on the imaging characteristics of these complications and the mechanisms underlying novel anticancer drugs.
4.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
5.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
6.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
7.18F‑FDG PET/CT in Inflammation and Infection: Procedural Guidelineby the Korean Society of Nuclear Medicine
Joon Ho CHOI ; Yong‑Jin PARK ; Hyunjong LEE ; Hye Ryeong KWON ; Jinkyoung OH ; Chae Hong LIM ; Eun Ji HAN ; Joon Young CHOI ;
Nuclear Medicine and Molecular Imaging 2025;59(1):27-40
This guideline outlines the use of 18F-fluoro-2-deoxyglucose positron emission tomography / computed tomography for the diagnosis and management of infectious and inflammatory diseases. It provides detailed recommendations for healthcare providers on patient preparation, imaging procedures, and the interpretation of results. Adapted from international standards and tailored to local clinical practices, the guideline emphasizes safety, quality control, and effective use of the technology in various conditions, including spinal infections, diabetic foot, osteomyelitis, vasculitis, and cardiac inflammation. The aim is to assist nuclear medicine professionals in delivering accurate diagnoses and improving patient outcomes while allowing flexibility to adapt to individual patient needs, technological advancements, and evolving medical knowledge. This document is a comprehensive resource for enhancing the quality and safety of 18F-fluoro-2-deoxyglucose positron emission tomography / computed tomography for the evaluation of infectious and inflammatory diseases.Preamble The Korean Society of Nuclear Medicine (KSNM) was established in 1961 to promote the clinical and technological advancement of nuclear medicine in South Korea, with members that include nuclear medicine physicians and associated scientists. The KSNM regularly formulates and revises procedural guidelines for nuclear medicine examinations to enhance the field and improve the quality of patient care. These guidelines are designed to support healthcare professionals in providing appropriate medical care to patients. However, they are not immutable rules or mandatory requirements for conducting examinations.Therefore, KSNM states that these guidelines should not be used in legal actions challenging a healthcare professional’s medical decisions. The ultimate judgment regarding specific procedures or appropriate measures should be made by nuclear medicine physicians, considering the unique circumstances of each case. Deviation from these guidelines does not imply substandard medical practice. Rather, reasonable judgments differing from the guidelines can be made based on the patient’s condition, available resources, and advancements in knowledge or technology. Due to the diversity and complexity of patients, it is often challenging to predict the most appropriate diagnostic and accurate therapeutic responses. Thus, adherence to these guidelines does not always guarantee an exact diagnosis or successful outcomes.The purpose of this guideline is to assist healthcare providers in making reasonable decisions and conducting effective and safe examinations based on current medical knowledge, available resources, and patient needs when performing 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) examinations for infectious/ inflammatory diseases.
8.Machine Learning Models to Identify Individuals With Imminent Suicide Risk Using a Wearable Device: A Pilot Study
Jumyung UM ; Jongsu PARK ; Dong Eun LEE ; Jae Eun AHN ; Ji Hyun BAEK
Psychiatry Investigation 2025;22(2):156-166
Objective:
We aimed to determine whether individuals at immediate risk of suicide could be identified using data from a commercially available wearable device.
Methods:
Thirty-nine participants experiencing acute depressive episodes and 20 age- and sex-matched healthy controls wore a commercially available wearable device (Galaxy Watch Active2) for two months. We collected data on activities, sleep, and physiological metrics like heart rate and heart rate variability using the wearable device. Participants rated their mood spontaneously twice daily on a Likert scale displayed on the device. Mood ratings by clinicians were performed at weeks 0, 2, 4, and 8. The suicide risk was assessed using the Hamilton Depression Rating Scale’s suicide item score (HAMD-3). We developed two predictive models using machine learning: a single-level model that processed all data simultaneously to identify those at immediate suicide risk (HAMD-3 scores ≥1) and a multilevel model. We compared the predictions of imminent suicide risk from both models.
Results:
Both the single-step and multi-step models effectively predicted imminent suicide risk. The multi-step model outperformed the single-step model in predicting imminent suicide risk with area under the curve scores of 0.89 compared to 0.88. In the multi-step model, the HAMD total score and heart rate variability were most significant, whereas in the single-step model, the HAMD total score and diagnosis were key predictors.
Conclusion
Wearable devices are a promising tool for identifying individuals at immediate risk of suicide. Future research with more refined temporal resolution is recommended.
9.Complete mouth rehabilitation with fixed implant-supported prosthesis in an edentulous maxilla using dental CAD-CAM technology
Jeong Eun HONG ; Hwa-Ryun CHA ; Ji-Won BANG ; Seong-A KIM ; Keun-Woo LEE ; Yong-Sang LEE ; Hee-Won JANG
The Journal of Korean Academy of Prosthodontics 2025;63(2):194-202
For patients with edentulous maxillae, creating a prosthetic treatment plan involves considering anatomical factors, aesthetics, the patient’s financial situation, and oral hygiene capabilities. In this case, CAD-CAM technology was used to accurately plan implant placements for a full arch fixed restoration based on the design of the final prosthesis. A customized surgical guide ensured precise implant placement and a provisional restoration was created using CAD-CAM. The definitive prosthesis was then created based on the second provisional restoration that has been previously used and adjusted by the patient. This approach achieved an excellent functional and aesthetic outcome, highlighting the benefits of digital approach and its potential for further clinical applications.
10.Rapidly Growing Gastrointestinal Stromal Tumor on the Esophagus
Ji Hye PARK ; Sung Eun KIM ; Seun Ja PARK ; Moo In PARK ; Won MOON ; Jae Hyun KIM ; Kyoungwon JUNG ; Myung Hun LEE
The Korean Journal of Helicobacter and Upper Gastrointestinal Research 2025;25(1):64-69
Gastrointestinal stromal tumors (GISTs) are rare mesenchymal neoplasms that mainly occur in the stomach and small intestine; those arising in the esophagus are rarer. A 54-year-old woman was referred to our hospital with a one-month history of dysphagia. Esophagogastroduodenoscopy (EGD), performed approximately five months earlier, had not revealed any specific findings. However, an EGD performed in our hospital showed the presence of a round, protruding lesion (approximately 40×30 mm in size), with a normal overlying mucosal surface, 35–39 cm from the upper incisor. Chest computed tomography (CT) revealed a large esophageal mass. Enucleation was performed on the esophageal mass, and a GIST was diagnosed using immunochemical staining. Imatinib mesylate administration was initiated two months postoperatively. The patient was stable, without any evident recurrence in the 8-month postoperative follow-up EGD and chest CT examinations. Therefore, physicians should consider that patients with worsening dysphagia may have an underlying organic condition, such as an acute increase in size of an esophageal GIST, even if recent examinations were unremarkable.

Result Analysis
Print
Save
E-mail