1.Risk Factor Analysis of Cryopreserved Autologous Bone Flap Resorption in Adult Patients Undergoing Cranioplasty with Volumetry Measurement Using Conventional Statistics and Machine-Learning Technique
Journal of Korean Neurosurgical Society 2024;67(1):103-114
Objective:
: Decompressive craniectomy (DC) with duroplasty is one of the common surgical treatments for life-threatening increased intracranial pressure (ICP). Once ICP is controlled, cranioplasty (CP) with reinsertion of the cryopreserved autologous bone flap or a synthetic implant is considered for protection and esthetics. Although with the risk of autologous bone flap resorption (BFR), cryopreserved autologous bone flap for CP is one of the important material due to its cost effectiveness. In this article, we performed conventional statistical analysis and the machine learning technique understand the risk factors for BFR.
Methods:
: Patients aged >18 years who underwent autologous bone CP between January 2015 and December 2021 were reviewed. Demographic data, medical records, and volumetric measurements of the autologous bone flap volume from 94 patients were collected. BFR was defined with absolute quantitative method (BFR-A) and relative quantitative method (BFR%). Conventional statistical analysis and random forest with hyper-ensemble approach (RF with HEA) was performed. And overlapped partial dependence plots (PDP) were generated.
Results:
: Conventional statistical analysis showed that only the initial autologous bone flap volume was statistically significant on BFR-A. RF with HEA showed that the initial autologous bone flap volume, interval between DC and CP, and bone quality were the factors with most contribution to BFR-A, while, trauma, bone quality, and initial autologous bone flap volume were the factors with most contribution to BFR%. Overlapped PDPs of the initial autologous bone flap volume on the BRF-A crossed at approximately 60 mL, and a relatively clear separation was found between the non-BFR and BFR groups. Therefore, the initial autologous bone flap of over 60 mL could be a possible risk factor for BFR.
Conclusion
: From the present study, BFR in patients who underwent CP with autologous bone flap might be inevitable. However, the degree of BFR may differ from one to another. Therefore, considering artificial bone flaps as implants for patients with large DC could be reasonable. Still, the risk factors for BFR are not clearly understood. Therefore, chronological analysis and pathophysiologic studies are needed.
2.Pharmacological Management of Germinal Matrix-Intraventricular Hemorrhage
Jaewoo CHUNG ; Sang Koo LEE ; Chun-Sung CHO ; Young Jin KIM ; Jung Ho KO ; Jung-Ho YUN ; Jin-Shup SO ; In-Ho JUNG
Journal of Korean Neurosurgical Society 2023;66(3):258-262
Germinal matrix-intraventricular hemorrhage (GM-IVH) is among the devastating neurological complications with mortality and neurodevelopmental disability rates ranging from 14.7% to 44.7% in preterm infants. The medical techniques have improved throughout the years, as the morbidity-free survival rate of very-low-birth-weight infants has increased; however, the neonatal and long-term morbidity rates have not significantly improved. To this date, there is no strong evidence on pharmacological management on GM-IVH, due to the limitation of well-designed randomized controlled studies. However, recombinant human erythropoietin administration in preterm infants seems to be the only effective pharmacological management in limited situations. Hence, further high-quality collaborative research studies are warranted in the future to ensure better outcomes among preterm infants with GM-IVH.
3.Fencing Knife-Induced Transorbital Penetrating Brain Injury: A Case Report
Sung Jin KIM ; In-Ho JUNG ; Jaewoo CHUNG
Korean Journal of Neurotrauma 2023;19(3):363-369
Penetrating brain injury (PBI) is a rare type of traumatic brain injury, which accounts for 0.4% of all head trauma cases. In this study, we describe a 14-year-old male adolescent who sustained a transorbital penetrating injury caused by a fencing knife. Although the patient visited the hospital after the foreign body had been removed, we diagnosed a PBI based on identification of a linear injury trajectory extending from an orbital roof fracture to the contralateral parietal lobe, using three-dimensional reconstruction of the hemorrhage. The patient fully recovered after conservative treatment. We hope that sharing our experience will serve as a guideline for the clinical management of PBI.
4.Anticoagulation and Antiplatelet Agent Resumption Timing fo
In-Ho JUNG ; Jung-Ho YUN ; Sung Jin KIM ; Jaewoo CHUNG ; Sang Koo LEE
Korean Journal of Neurotrauma 2023;19(3):298-306
Traumatic brain injury (TBI) is a major global health concern. Due to the increase in TBI incidence and the aging population, an increasing number of patients with TBI are taking antithrombotic agents for their underlying disease. When TBI occurs in patients with these diseases, there is a conflict between the disease, which requires an antithrombotic effect, and the neurosurgeon, who must minimize intracranial hemorrhage. Nevertheless, there are no clear guidelines for the reversal or resumption of antithrombotic agents when TBI occurs in patients taking antithrombotic agents. In this review article, we intend to classify antithrombotic agents and provide information on them. We also share previous studies on the reversal and resumption of antithrombotic agents in patients with TBI to help neurosurgeons in this dilemma.
5.Angiographic Follow-Up for Small Ruptured Intracranial Aneurysm Treated by Endovascular Treatment : Follow-Up Plan and Long-Term Follow-Up Results
Tae Hyung KIM ; Jung Ho KO ; Jaewoo CHUNG
Journal of Korean Neurosurgical Society 2022;65(5):710-718
Objective:
: Although endovascular treatment for intracranial aneurysms is considered effective and safe, its durability is still debated. Also, few studies have described angiographic follow-up plan after endovascular treatment of intracranial aneurysm, especially in ruptured cases. Hence, we report the long-term results of follow-up angiography protocol.
Methods:
: Radiological records of 639 cases of coil embolization with ruptured aneurysms from March 2003 to December 2016 were retrospectively reviewed. Patients who received treatment of a saccular aneurysm less than 7 mm resulted with near complete occlusion were included. Two hundred thirty-eight aneuryms which received the follow-up angiography at least once were enrolled. We classified four periods of follow-up as follows : post-treatment 1 year (defined as the first period), from 1 to 2 years (the second period), 2 to 5 years (the third period), and over 5 years (long-term).
Results:
: We identified 14 cases (6.4%) of recurrence from 218 aneurysms in follow-up angiography in the first period. Among 143 aneurysms in the second period, five cases (3.5%) of recurrence were identified. There were no findings suspicious of recanalization in 97 patients in the third period. Of the total 238 cases, there were 19 recurrences, for a recurrence rate of 8.0%. Six (31.6%) out of 19 recurrences showed a tendency toward repeat recurrences even after additional treatment. Twenty-eight received long-term follow-up over 5 years and there was no recurrence.
Conclusion
: Most of the recurrence were found during the first and the second year. We suggest that at least one digital subtraction angiography examination may be necessary around post-treatment 2 years, especially in ruptured cases. If the angiographic results are favorable at 2 years post-treatment, long-term result should be favorable.
7.White Cord Syndrome: A Reperfusion Injury Following Spinal Decompression Surgery
Jin-Shup SO ; Young-Jin KIM ; Jaewoo CHUNG
Korean Journal of Neurotrauma 2022;18(2):380-386
Reperfusion injury of the spinal cord has been scarcely reported. Herein, we present a case of white cord syndrome after spinal decompression. A 61-year-old male, who initially had ossification of the posterior longitudinal ligament at C3-6 level, was admitted to our hospital with a ruptured disc at the C6-7 level. The patient experienced radiating pain in both upper extremities. Anterior cervical discectomy and fusion was performed. However, the patient developed quadriplegia. Emergency magnetic resonance imaging revealed a new and enlarged signal change in the spinal cord at the C4-7 level. Additional posterior decompression surgery was performed. After intense rehabilitation, the patient’s motor function improved to grade 4. White cord syndrome is likely due to reperfusion injury following operative decompression of a compressed spinal cord segment. Although rare, spine surgeons should be aware of this complication and warn patients preoperatively.
8.An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities
Journal of Korean Neurosurgical Society 2021;64(4):514-523
Objective:
: Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms.
Methods:
: Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods.
Results:
: We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large.
Conclusion
: In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.
9.An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities
Journal of Korean Neurosurgical Society 2021;64(4):514-523
Objective:
: Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms.
Methods:
: Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods.
Results:
: We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large.
Conclusion
: In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.
10.Safety and Effectiveness of Percutaneous Low-Dose Thrombin Injection for Femoral Puncture Site Pseudoaneurysms in Neurointervention: Single-Center Experience
Jae Ho SHIN ; Yunsun SONG ; Jae Jon SHEEN ; Dongwhane LEE ; Jaewoo CHUNG ; Ga Young LEE ; Hyunhee JEONG ; Seongsik HAN ; Joon Ho CHOI ; Seon Moon HWANG ; Deok Hee LEE
Neurointervention 2020;15(1):25-30
Purpose:
We present ultrasound-guided percutaneous low-dose thrombin (200–250 IU) injection for the treatment of iatrogenic femoral pseudoaneurysms. Second, we compared patient and procedure factors between subcutaneous hematoma and pseudoaneurysm groups.
Materials and Methods:
From April 2012 to May 2018, 8425 patients underwent neurointervention. Among these patients, 18 had small subcutaneous hematomas and 6 had pseudoaneurysms. Pseudoaneurysms in the neck and entire sac were visualized, and low-dose thrombins were injected while visualizing a “whirlpool” hyperechoic core in the pseudoaneurysm sac. Subcutaneous hematomas were treated with simple compression. We compared the following parameters between the subcutaneous hematoma group and pseudoaneurysm group: sex, age, body mass index (BMI), type of procedure, heparin usage, sheath size, procedure time, and number of previous neurointervention procedures with the Mann-Whitney U test.
Results:
Most of the pseudoaneurysms were successfully occluded with 200 IU of thrombin (n=5). Only 1 pseudoaneurysm required a slightly higher thrombin concentration (250 IU, n=1). During the short-term follow-up, no residual sac was observed and no surgical repair was necessary. Pain in the groin region was alleviated. During the 1-month follow-up, no evidence of pseudoaneurysm recurrence nor subcutaneous hematoma was noted. Patient factors (sex, age, and BMI) and procedure factors (heparin usage, sheath size, procedure time, number of previous procedures) were not statistically different between the subcutaneous hematoma and pseudoaneurysm groups.
Conclusion
Ultrasound-guided percutaneous low-dose thrombin injection (200–250 IU) is safe, effective, and less invasive for treating iatrogenic femoral pseudoaneurysm in neurointervention.

Result Analysis
Print
Save
E-mail