1.The feasibility of anterior plate fixation in distal-third humeral shaft fractures: a retrospective case series
Ki-Tae KIM ; Seung Je KIM ; Jae Woo SHIM
Archives of hand and microsurgery 2025;30(1):86-94
Purpose:
The surgical approaches and types of implants used for the fixation of distal-third humerus shaft fractures remain a matter of debate. We examined fracture patterns and evaluated the feasibility of plate fixation via an anterior approach.
Methods:
We conducted a retrospective study of 22 patients who underwent surgical treatment for distal-third humerus fractures from 2019 to 2023, with a minimum follow-up period of 6 months for all included patients. An anterolateral approach was used to perform open reduction and internal fixation. The minimum cortical width required for screw fixation at the most proximal part of the distal fragment was set at 10 mm.
Results:
The mean age of the patients was 38 years. Simple spiral and wedge fractures were predominant (86.3%). The distal fragment fracture line distribution was, on average, 30 mm (4–50 mm) to 101 mm (57–145 mm) from the coronoid fossa proximal margin. The mean distance sufficient to achieve bicortical purchase, engaging both the near and far cortices, was 61 mm (36–96 mm). An anterolateral approach was used in 18 patients based on computed tomography measurements of approximately 50 mm. An average of eight cortices were fixed in the distal fragment. All patients achieved bone union within 12 weeks without complications (mean, 12.69±2.43 weeks).
Conclusion
Stable fixation was achieved with an anterior straight plate when 50 mm of the distal fragment was secured from the coronoid fossa’s proximal margin, with both cortices measuring at least 10 mm in width.
2.Palliative Care and Hospice for Heart Failure Patients: Position Statement From the Korean Society of Heart Failure
Seung-Mok LEE ; Hae-Young LEE ; Shin Hye YOO ; Hyun-Jai CHO ; Jong-Chan YOUN ; Seong-Mi PARK ; Jin-Ok JEONG ; Min-Seok KIM ; Chi Young SHIM ; Jin Joo PARK ; Kye Hun KIM ; Eung Ju KIM ; Jeong Hoon YANG ; Jae Yeong CHO ; Sang-Ho JO ; Kyung-Kuk HWANG ; Ju-Hee LEE ; In-Cheol KIM ; Gi Beom KIM ; Jung Hyun CHOI ; Sung-Hee SHIN ; Wook-Jin CHUNG ; Seok-Min KANG ; Myeong Chan CHO ; Dae-Gyun PARK ; Byung-Su YOO
International Journal of Heart Failure 2025;7(1):32-46
Heart failure (HF) is a major cause of mortality and morbidity in South Korea, imposing substantial physical, emotional, and financial burdens on patients and society. Despite the high burden of symptom and complex care needs of HF patients, palliative care and hospice services remain underutilized in South Korea due to cultural, institutional, and knowledge-related barriers. This position statement from the Korean Society of Heart Failure emphasizes the need for integrating palliative and hospice care into HF management to improve quality of life and support holistic care for patients and their families. By clarifying the role of palliative care in HF and proposing practical referral criteria, this position statement aims to bridge the gap between HF and palliative care services in South Korea, ultimately improving patient-centered outcomes and aligning treatment with the goals and values of HF patients.
3.The feasibility of anterior plate fixation in distal-third humeral shaft fractures: a retrospective case series
Ki-Tae KIM ; Seung Je KIM ; Jae Woo SHIM
Archives of hand and microsurgery 2025;30(1):86-94
Purpose:
The surgical approaches and types of implants used for the fixation of distal-third humerus shaft fractures remain a matter of debate. We examined fracture patterns and evaluated the feasibility of plate fixation via an anterior approach.
Methods:
We conducted a retrospective study of 22 patients who underwent surgical treatment for distal-third humerus fractures from 2019 to 2023, with a minimum follow-up period of 6 months for all included patients. An anterolateral approach was used to perform open reduction and internal fixation. The minimum cortical width required for screw fixation at the most proximal part of the distal fragment was set at 10 mm.
Results:
The mean age of the patients was 38 years. Simple spiral and wedge fractures were predominant (86.3%). The distal fragment fracture line distribution was, on average, 30 mm (4–50 mm) to 101 mm (57–145 mm) from the coronoid fossa proximal margin. The mean distance sufficient to achieve bicortical purchase, engaging both the near and far cortices, was 61 mm (36–96 mm). An anterolateral approach was used in 18 patients based on computed tomography measurements of approximately 50 mm. An average of eight cortices were fixed in the distal fragment. All patients achieved bone union within 12 weeks without complications (mean, 12.69±2.43 weeks).
Conclusion
Stable fixation was achieved with an anterior straight plate when 50 mm of the distal fragment was secured from the coronoid fossa’s proximal margin, with both cortices measuring at least 10 mm in width.
4.The feasibility of anterior plate fixation in distal-third humeral shaft fractures: a retrospective case series
Ki-Tae KIM ; Seung Je KIM ; Jae Woo SHIM
Archives of hand and microsurgery 2025;30(1):86-94
Purpose:
The surgical approaches and types of implants used for the fixation of distal-third humerus shaft fractures remain a matter of debate. We examined fracture patterns and evaluated the feasibility of plate fixation via an anterior approach.
Methods:
We conducted a retrospective study of 22 patients who underwent surgical treatment for distal-third humerus fractures from 2019 to 2023, with a minimum follow-up period of 6 months for all included patients. An anterolateral approach was used to perform open reduction and internal fixation. The minimum cortical width required for screw fixation at the most proximal part of the distal fragment was set at 10 mm.
Results:
The mean age of the patients was 38 years. Simple spiral and wedge fractures were predominant (86.3%). The distal fragment fracture line distribution was, on average, 30 mm (4–50 mm) to 101 mm (57–145 mm) from the coronoid fossa proximal margin. The mean distance sufficient to achieve bicortical purchase, engaging both the near and far cortices, was 61 mm (36–96 mm). An anterolateral approach was used in 18 patients based on computed tomography measurements of approximately 50 mm. An average of eight cortices were fixed in the distal fragment. All patients achieved bone union within 12 weeks without complications (mean, 12.69±2.43 weeks).
Conclusion
Stable fixation was achieved with an anterior straight plate when 50 mm of the distal fragment was secured from the coronoid fossa’s proximal margin, with both cortices measuring at least 10 mm in width.
5.Angiographic Anatomy of the Prostatic Artery in the Korean Population: A Bicentric Retrospective Study
Seunghyun LEE ; Dong Jae SHIM ; Doyoung KIM ; Soo Buem CHO ; Seung Hwan BAEK ; Edward Wolfgang LEE ; Jung Whee LEE
Korean Journal of Radiology 2024;25(11):1011-1021
Objective:
The aim of this study was to analyze the origins of prostatic arteries (PAs) in the Korean population and compare them with those reported in the literature.
Materials and Methods:
From April 2018 to February 2024, 108 male (mean age ± standard deviation: 71.6 ± 9.7 years) with lower urinary tract symptoms (n = 102) or refractory hematuria (n = 6) underwent prostatic artery embolization (PAE). Computed tomography and angiography images were retrospectively reviewed. The branching pattern of the internal iliac artery (IIA) was classified according to the Yamaki system. The origin of the PA was categorized using the de Assis definition, and the incidence of each type was recorded. A systematic literature review was conducted and the most common types of PA were investigated.
Results:
PAE was successfully implemented on 211 of the 216 pelvic sidewalls. PA cannulation failed in five sidewalls due to a steno-occlusive state. The most common IIA type was type A, in which the IIA was divided into the superior gluteal artery and gluteal–pudendal trunk (77%). Of 226 PAs analyzed, including 15 in 211 sidewalls exhibiting dual PAs, the most common PA origin was the internal pudendal artery (type IV, 35%), followed by the superior vesical (type I, 25%) and obturator (type III, 21%) arteries. Anterior division of IIA (type II) was less common (10%). Type V (uncommon origins) occurred in 8% of cases, including five distal internal pudendal arteries, four quadfurcations, three inferior gluteal arteries, three trifurcations, two medial femoral circumflex arteries, and two rectal arteries. Two of the five patients with surgically or endovascularly altered anatomy were successfully treated via PAs originating from the medial femoral circumflex arteries. Globally, type I is the most common PA type.
Conclusion
In the Korean population, the most common IIA pattern and PA origin were types A and IV, respectively.
6.Fabrication of implant supported overdenture using existing implants: a case report
Seung-Jae BAEK ; Han-Na LEE ; Ji-Suk SHIM ; Jeong-Yol LEE
The Journal of Korean Academy of Prosthodontics 2024;62(4):285-294
Although the proportion of edentulous patients is declining, the aging population has resulted in an increase in their absolute numbers. Conventional complete dentures can partially restore oral function but have significant limitations such as low retention and relatively poor masticatory ability. Therefore, implant overdentures have been proposed as an alternative, offering enhanced functionality, higher patient satisfaction, and cost-effectiveness compared to fixed implants. In this case, a 74-year-old female patient presented with complaints about her existing implant overdenture, fabricated in 2010, which frequently dislodged and was aesthetically unpleasing. Clinical examination revealed worn attachments and artificial teeth, as well as insufficient upper lip support. It was decided to remake the implant overdentures utilizing the existing implants. During the fabrication, the patient continued to use her previous denture. After evaluating the occlusal relationships, facial form, and vertical dimension, the new overdentures were fabricated. The newly created implant overdentures showed satisfactory aesthetic and functional results, and the patient was satisfied.
7.Angiographic Anatomy of the Prostatic Artery in the Korean Population: A Bicentric Retrospective Study
Seunghyun LEE ; Dong Jae SHIM ; Doyoung KIM ; Soo Buem CHO ; Seung Hwan BAEK ; Edward Wolfgang LEE ; Jung Whee LEE
Korean Journal of Radiology 2024;25(11):1011-1021
Objective:
The aim of this study was to analyze the origins of prostatic arteries (PAs) in the Korean population and compare them with those reported in the literature.
Materials and Methods:
From April 2018 to February 2024, 108 male (mean age ± standard deviation: 71.6 ± 9.7 years) with lower urinary tract symptoms (n = 102) or refractory hematuria (n = 6) underwent prostatic artery embolization (PAE). Computed tomography and angiography images were retrospectively reviewed. The branching pattern of the internal iliac artery (IIA) was classified according to the Yamaki system. The origin of the PA was categorized using the de Assis definition, and the incidence of each type was recorded. A systematic literature review was conducted and the most common types of PA were investigated.
Results:
PAE was successfully implemented on 211 of the 216 pelvic sidewalls. PA cannulation failed in five sidewalls due to a steno-occlusive state. The most common IIA type was type A, in which the IIA was divided into the superior gluteal artery and gluteal–pudendal trunk (77%). Of 226 PAs analyzed, including 15 in 211 sidewalls exhibiting dual PAs, the most common PA origin was the internal pudendal artery (type IV, 35%), followed by the superior vesical (type I, 25%) and obturator (type III, 21%) arteries. Anterior division of IIA (type II) was less common (10%). Type V (uncommon origins) occurred in 8% of cases, including five distal internal pudendal arteries, four quadfurcations, three inferior gluteal arteries, three trifurcations, two medial femoral circumflex arteries, and two rectal arteries. Two of the five patients with surgically or endovascularly altered anatomy were successfully treated via PAs originating from the medial femoral circumflex arteries. Globally, type I is the most common PA type.
Conclusion
In the Korean population, the most common IIA pattern and PA origin were types A and IV, respectively.
8.Fabrication of implant supported overdenture using existing implants: a case report
Seung-Jae BAEK ; Han-Na LEE ; Ji-Suk SHIM ; Jeong-Yol LEE
The Journal of Korean Academy of Prosthodontics 2024;62(4):285-294
Although the proportion of edentulous patients is declining, the aging population has resulted in an increase in their absolute numbers. Conventional complete dentures can partially restore oral function but have significant limitations such as low retention and relatively poor masticatory ability. Therefore, implant overdentures have been proposed as an alternative, offering enhanced functionality, higher patient satisfaction, and cost-effectiveness compared to fixed implants. In this case, a 74-year-old female patient presented with complaints about her existing implant overdenture, fabricated in 2010, which frequently dislodged and was aesthetically unpleasing. Clinical examination revealed worn attachments and artificial teeth, as well as insufficient upper lip support. It was decided to remake the implant overdentures utilizing the existing implants. During the fabrication, the patient continued to use her previous denture. After evaluating the occlusal relationships, facial form, and vertical dimension, the new overdentures were fabricated. The newly created implant overdentures showed satisfactory aesthetic and functional results, and the patient was satisfied.
9.Angiographic Anatomy of the Prostatic Artery in the Korean Population: A Bicentric Retrospective Study
Seunghyun LEE ; Dong Jae SHIM ; Doyoung KIM ; Soo Buem CHO ; Seung Hwan BAEK ; Edward Wolfgang LEE ; Jung Whee LEE
Korean Journal of Radiology 2024;25(11):1011-1021
Objective:
The aim of this study was to analyze the origins of prostatic arteries (PAs) in the Korean population and compare them with those reported in the literature.
Materials and Methods:
From April 2018 to February 2024, 108 male (mean age ± standard deviation: 71.6 ± 9.7 years) with lower urinary tract symptoms (n = 102) or refractory hematuria (n = 6) underwent prostatic artery embolization (PAE). Computed tomography and angiography images were retrospectively reviewed. The branching pattern of the internal iliac artery (IIA) was classified according to the Yamaki system. The origin of the PA was categorized using the de Assis definition, and the incidence of each type was recorded. A systematic literature review was conducted and the most common types of PA were investigated.
Results:
PAE was successfully implemented on 211 of the 216 pelvic sidewalls. PA cannulation failed in five sidewalls due to a steno-occlusive state. The most common IIA type was type A, in which the IIA was divided into the superior gluteal artery and gluteal–pudendal trunk (77%). Of 226 PAs analyzed, including 15 in 211 sidewalls exhibiting dual PAs, the most common PA origin was the internal pudendal artery (type IV, 35%), followed by the superior vesical (type I, 25%) and obturator (type III, 21%) arteries. Anterior division of IIA (type II) was less common (10%). Type V (uncommon origins) occurred in 8% of cases, including five distal internal pudendal arteries, four quadfurcations, three inferior gluteal arteries, three trifurcations, two medial femoral circumflex arteries, and two rectal arteries. Two of the five patients with surgically or endovascularly altered anatomy were successfully treated via PAs originating from the medial femoral circumflex arteries. Globally, type I is the most common PA type.
Conclusion
In the Korean population, the most common IIA pattern and PA origin were types A and IV, respectively.
10.Fabrication of implant supported overdenture using existing implants: a case report
Seung-Jae BAEK ; Han-Na LEE ; Ji-Suk SHIM ; Jeong-Yol LEE
The Journal of Korean Academy of Prosthodontics 2024;62(4):285-294
Although the proportion of edentulous patients is declining, the aging population has resulted in an increase in their absolute numbers. Conventional complete dentures can partially restore oral function but have significant limitations such as low retention and relatively poor masticatory ability. Therefore, implant overdentures have been proposed as an alternative, offering enhanced functionality, higher patient satisfaction, and cost-effectiveness compared to fixed implants. In this case, a 74-year-old female patient presented with complaints about her existing implant overdenture, fabricated in 2010, which frequently dislodged and was aesthetically unpleasing. Clinical examination revealed worn attachments and artificial teeth, as well as insufficient upper lip support. It was decided to remake the implant overdentures utilizing the existing implants. During the fabrication, the patient continued to use her previous denture. After evaluating the occlusal relationships, facial form, and vertical dimension, the new overdentures were fabricated. The newly created implant overdentures showed satisfactory aesthetic and functional results, and the patient was satisfied.

Result Analysis
Print
Save
E-mail