1.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
2.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
3.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
4.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
5.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
6.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
7.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
8.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
9.Diode Laser—Can It Replace the Electrical Current Used in Endoscopic Submucosal Dissection? (with Video)
Yunho JUNG ; Gwang Ho BAIK ; Weon Jin KO ; Bong Min KO ; Seong Hwan KIM ; Jin Seok JANG ; Jae-Young JANG ; Wan-Sik LEE ; Young Kwan CHO ; Sun Gyo LIM ; Hee Seok MOON ; In Kyung YOO ; Joo Young CHO
Clinical Endoscopy 2021;54(4):555-562
Background/Aims:
A new medical fiber-guided diode laser system (FDLS) is expected to offer high-precision cutting with simultaneous hemostasis. Thus, this study aimed to evaluate the feasibility of using the 1,940-nm FDLS to perform endoscopic submucosal dissection (ESD) in the gastrointestinal tract of an animal model.
Methods:
In this prospective animal pilot study, gastric and colorectal ESD using the FDLS was performed in ex vivo and in vivo porcine models. The completeness of en bloc resection, the procedure time, intraprocedural bleeding, histological injuries to the muscularis propria (MP) layer, and perforation were assessed.
Results:
The en bloc resection and perforation rates in the ex vivo study were 100% (10/10) and 10% (1/10), respectively; those in the in vivo study were 100% (4/4) and 0% for gastric ESD and 100% (4/4) and 25% (1/4) for rectal ESD, respectively. Deep MP layer injuries tended to occur more frequently in the rectal than in the gastric ESD cases, and no intraprocedural bleeding occurred in either group.
Conclusions
The 1,940-nm FDLS was capable of yielding high en bloc resection rates without intraprocedural bleeding during gastric and colorectal ESD in animal models.
10.Diode Laser—Can It Replace the Electrical Current Used in Endoscopic Submucosal Dissection? (with Video)
Yunho JUNG ; Gwang Ho BAIK ; Weon Jin KO ; Bong Min KO ; Seong Hwan KIM ; Jin Seok JANG ; Jae-Young JANG ; Wan-Sik LEE ; Young Kwan CHO ; Sun Gyo LIM ; Hee Seok MOON ; In Kyung YOO ; Joo Young CHO
Clinical Endoscopy 2021;54(4):555-562
Background/Aims:
A new medical fiber-guided diode laser system (FDLS) is expected to offer high-precision cutting with simultaneous hemostasis. Thus, this study aimed to evaluate the feasibility of using the 1,940-nm FDLS to perform endoscopic submucosal dissection (ESD) in the gastrointestinal tract of an animal model.
Methods:
In this prospective animal pilot study, gastric and colorectal ESD using the FDLS was performed in ex vivo and in vivo porcine models. The completeness of en bloc resection, the procedure time, intraprocedural bleeding, histological injuries to the muscularis propria (MP) layer, and perforation were assessed.
Results:
The en bloc resection and perforation rates in the ex vivo study were 100% (10/10) and 10% (1/10), respectively; those in the in vivo study were 100% (4/4) and 0% for gastric ESD and 100% (4/4) and 25% (1/4) for rectal ESD, respectively. Deep MP layer injuries tended to occur more frequently in the rectal than in the gastric ESD cases, and no intraprocedural bleeding occurred in either group.
Conclusions
The 1,940-nm FDLS was capable of yielding high en bloc resection rates without intraprocedural bleeding during gastric and colorectal ESD in animal models.

Result Analysis
Print
Save
E-mail