1.Establishment and clinical application of modified endoscopic freka trelumina placement.
Yankang FENG ; Ming CUI ; Yun HE ; Xilong ZHAO
Chinese Journal of Gastrointestinal Surgery 2019;22(1):79-84
OBJECTIVE:
To establish a modified endoscopic Freka Trelumina placement (mEFTP) for modifying or substituting the traditional endoscopic Freka Trelumina placement (EFTP) and to explore the safety and feasibility of mEFTP in patients requiring enteral nutrition and gastrointestinal decompression in general surgery.
METHODS:
A retrospective cohort study was conducted to analyze the clinical data of patients undergoing EFTP or mEFTP at General Surgery Department of 920 Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army from January 2016 to January 2018.
INCLUSION CRITERIA:
the function of lower digestive tract was normal; patients who could not eat through mouth or nasogastric tube needed to have enteral nutrition and gastrointestinal decompression; the retention time of Freka Trelumina (FT) was not expected to exceed 2 months.
EXCLUSION CRITERIA:
contraindication for gastroscopy; suspected shock or digestive tract perforation; suspected mental diseases; infectious diseases of digestive tract; thoracoabdominal aortic aneurysm. mEFIP procedure was as follow. FT was inserted into stomach through one side nasal cavity, gastroscope was inserted into stomach cavity, and the front part of FT was clamped with biopsy forceps through biopsy hole. Biopsy forceps and FT were inserted into the pylorus or anastomosis under gastroscope, and they were pushed into the duodenum or output loop. During pushing, the gastroscope did not pass through the duodenum or output loop. The biopsy forceps was released and pushed out, and FT was pushed with biopsy forceps synchronously into the duodenum or output loop more than 5 cm. The foreign body forceps was inserted through the biopsy hole, and the FT tube was held in the stomach and pushed to the duodenum or output loop. The previous steps repeated until the suction cavity reached the pylorus or anastomosis. The gastroscope was exited gently; the guide wire was pulled out slowly. EFTP procedure: foreign body forceps was used to clamp the front part of FT, and gastroscope, foreign body forceps and FT pass the pylorus or anastomosis simultaneously to reach the descendent duodenum or output loop as a whole. The time of catheterization was recorded and position of FT was examined by X-ray within 1 h after catheterization. The success rate of catheterization and morbidity of complications after catheterization were evaluated and compared between the two groups.
RESULTS:
A total of 141 patients were enrolled, 72 in the mEFTP group and 69 in the EFTP group. In mEFTP group, 45 cases were males and 27 were females with an average age of 55.8(37-76) years; 27 cases had normal upper gastrointestinal anatomy (postoperative gastroplegia syndrome due to colon cancer in 17 cases, due to rectal cancer in 10 cases) and 45 had upper gastrointestinal anatomic changes (gastric cancer with pylorus obstruction in 18 cases and anastomotic block after gastroenterostomy in 27 cases). In the EFTP group, 41 were males and 28 were females with an average age of 55.3(36-79) years; 33 cases had normal upper gastrointestinal anatomy (postoperative gastroplegia syndrome due to colon cancer in 20 cases, due to rectal cancer in 13 cases) and 36 had upper gastrointestinal anatomic changes (gastric cancer with pylorus obstruction in 15 cases and anastomotic block after gastroenterostomy in 21 cases). In patients with normal upper digestive tract anatomy, the average catheterization time of mEFTP was (4.9±1.7) minutes which was shorter than (7.6±1.7) minutes of EFTP(t=6.683, P<0.001). In patients of gastric cancer with pyloric obstruction, the average catheterization time of mEFTP was (6.6±1.6) minutes which was shorter than (10.5±2.6) minutes of EFTP (t=4.724, P<0.001). In patients with anastomotic block after gastroenterostomy, the average catheterization time of mEFTP was (11.3±2.5) minutes which was shorter than (15.1±3.5) minutes of EFTP (t=4.513, P<0.001). In patients with normal upper gastrointestinal anatomy, there were no significant differences in the success rate of catheterization and the morbidity of catheterization complication between mEFTP and EFTP (all P>0.05). In patients with upper gastrointestinal anatomic changes, the success rate of catheterization in mEFTP was even higher than that in EFTP, but the difference was not significant [97.8%(41/45) vs. 86.1%(31/36), χ²=2.880, P=0.089]; while the morbidity of catheterization complication in mEFTP was lower than that in EFTP [0 vs. 8.3%(3/36), χ²=3.894, P=0.048].
CONCLUSIONS
Whether the upper gastrointestinal anatomy is normal or not, mEFTP presents shorter catheterization time, higher success catheterization rate than EFTP, and is safety. mEFTP can be widely applied to clinical practice for patients requiring enteral nutrition and gastrointestinal decompression.
Adult
;
Aged
;
Decompression, Surgical
;
instrumentation
;
methods
;
Enteral Nutrition
;
instrumentation
;
methods
;
Female
;
Gastric Outlet Obstruction
;
etiology
;
surgery
;
Gastroparesis
;
etiology
;
surgery
;
Gastroscopy
;
instrumentation
;
methods
;
Humans
;
Intubation, Gastrointestinal
;
instrumentation
;
methods
;
Male
;
Middle Aged
;
Retrospective Studies
;
Stomach Diseases
;
etiology
;
surgery
2.Fibreoptic intubation in airway management: a review article.
Jolin WONG ; John Song En LEE ; Theodore Gar Ling WONG ; Rehana IQBAL ; Patrick WONG
Singapore medical journal 2019;60(3):110-118
Since the first use of the flexible fibreoptic bronchoscope, a plethora of new airway equipment has become available. It is essential for clinicians to understand the role and limitations of the available equipment to make appropriate choices. The recent 4th National Audit Project conducted in the United Kingdom found that poor judgement with inappropriate choice of equipment was a contributory factor in airway morbidity and mortality. Given the many modern airway adjuncts that are available, we aimed to define the role of flexible fibreoptic intubation in decision-making and management of anticipated and unanticipated difficult airways. We also reviewed the recent literature regarding the role of flexible fibreoptic intubation in specific patient groups who may present with difficult intubation, and concluded that the flexible fibrescope maintains its important role in difficult airway management.
Airway Management
;
methods
;
Airway Obstruction
;
complications
;
Anesthesia
;
methods
;
Bronchoscopy
;
methods
;
Equipment Design
;
Fiber Optic Technology
;
Humans
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopes
;
Manikins
;
Obesity
;
complications
;
Respiratory System
;
Skull Fractures
;
complications
3.Prevailing practices in airway management: a prospective single-centre observational study of endotracheal intubation.
Geraldine Pei Chin CHEONG ; Anusha KANNAN ; Kwong Fah KOH ; Kumaresh VENKATESAN ; Edwin SEET
Singapore medical journal 2018;59(3):144-149
INTRODUCTIONAirway management during anaesthesia has potential difficulties and risks. We aimed to investigate the utility of routine airway assessment for predicting difficult tracheal intubation, review the prevailing practice of videolaryngoscope use amongst anaesthetists in a teaching hospital and determine the incidence of intraoperative and postoperative airway-related complications.
METHODSA prospective observational study of 1,654 patients undergoing general anaesthesia with endotracheal intubation over a seven-month period was performed. Data regarding airway and anaesthetic management was collected and analysed.
RESULTSVideolaryngoscopes were used as the first-choice equipment in 60.5% of the cohort. The incidence of difficult intubation was 2.1%, of which 45.7% of cases were unanticipated. The sensitivity of airway assessment was 54.3%, with a positive predictive value of 8.1%. When difficult intubation was anticipated, more videolaryngoscopes were used as the first equipment of choice compared to the Macintosh laryngoscope (p < 0.001). In the Macintosh group, more patients required a change of airway equipment (p = 0.015), but the number of intubation attempts was similar (p = 0.293). The incidence of intraoperative (p = 0.920) and postoperative complications (p = 0.380) were similar in both groups.
CONCLUSIONUsing the current predictors of difficult intubation, half of the difficult airways we encountered were unanticipated. Videolaryngoscopes were preferred when difficulty was anticipated and were also used in routine tracheal intubation.
Adult ; Aged ; Airway Management ; Anesthesia, General ; Anesthesiology ; education ; Humans ; Intubation, Intratracheal ; instrumentation ; Laryngoscopes ; Laryngoscopy ; Middle Aged ; Prospective Studies ; Trachea ; Video Recording
4.Predictors of Silicone Tube Intubation Success in Patients with Lacrimal Drainage System Stenosis.
Ji Sun BAEK ; Saem LEE ; Jung Hye LEE ; Hye Sun CHOI ; Jae Woo JANG ; Sung Joo KIM
Korean Journal of Ophthalmology 2016;30(3):157-162
PURPOSE: To evaluate prognostic factors affecting silicone tube intubation outcomes in Asian patients with lacrimal drainage system stenosis. METHODS: A retrospective review was conducted on the medical records of 822 patients (1,118 eyes) who had undergone silicone tube intubation to treat lacrimal drainage system stenosis between January 2011 and December 2012. Patients were divided into two groups: a success group and a failure group. Success was defined as the disappearance of epiphora symptoms, normalization of tear meniscus height, and the easy passage of fluid without resistance on the postoperative syringing test. Patient and ocular parameters were compared between the success and failure groups. RESULTS: A total of 994 eyes of 727 patients were included in analyses. Patients had a mean follow-up period of 34.11 ± 18.70 weeks. Silicone tube intubation was successful in 67.2% of participants. Significant differences between the success and failure groups were found for age (p < 0.001), history of ipsilateral facial palsy (p = 0.028), follow-up period (p < 0.001), and degree of passage on the preoperative syringing test (p = 0.001). Only age (p < 0.001) and degree of passage on the preoperative syringing test (p = 0.002) remained significantly associated with silicone tube intubation success in multivariate analysis. CONCLUSIONS: Age was negatively associated with silicone tube intubation success in patients with lacrimal drainage system stenosis. The success rate was higher in patients who showed easy passage of fluid without resistance on the preoperative syringing test. These factors should be considered by surgeons planning silicone tube intubation in patients with lacrimal drainage system stenosis.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Dacryocystorhinostomy/*methods
;
Female
;
Follow-Up Studies
;
Humans
;
Intubation/*instrumentation
;
Lacrimal Duct Obstruction/*diagnosis
;
Male
;
Middle Aged
;
Nasolacrimal Duct/*surgery
;
Postoperative Period
;
Retrospective Studies
;
*Silicones
;
Treatment Outcome
;
Young Adult
5.Clinics in diagnostic imaging (165). Oesophageal rupture secondary to malposition of an SB tube gastric balloon.
Wan Ying CHAN ; Hsueh Wen CHEONG ; Tien Jin TAN
Singapore medical journal 2016;57(2):92-quiz 96
Oesophageal rupture is a life-threatening complication of balloon tamponade for bleeding oesophageal varices. We herein describe the clinical course and imaging findings in a 33-year-old Indian man who had a Sengstaken-Blakemore (SB) tube inserted for uncontrolled haematemesis, which was unfortunately complicated by malposition of the gastric balloon with resultant oesophageal rupture. The inflated SB tube gastric balloon was visualised within the right hemithorax on chest radiography after the SB tube insertion. Further evaluation of the thorax on computed tomography confirmed the diagnosis of oesophageal rupture associated with right-sided haemopneumothorax. It is crucial for both the referring clinician and reporting radiologist to recognise early the imaging features of an incorrectly positioned SB tube gastric balloon, so as to ensure prompt intervention and a reduction in patient morbidity and mortality.
Adult
;
Diagnosis, Differential
;
Esophagus
;
injuries
;
Gastric Balloon
;
adverse effects
;
Gastrointestinal Hemorrhage
;
diagnosis
;
etiology
;
Humans
;
Intubation, Gastrointestinal
;
adverse effects
;
instrumentation
;
Male
;
Radiography, Thoracic
;
methods
;
Rupture
;
Tomography, X-Ray Computed
;
methods
6.Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis.
Jin Ha PARK ; Jong Seok LEE ; Sang Beom NAM ; Jin Wu JU ; Min Soo KIM
Yonsei Medical Journal 2016;57(4):987-997
PURPOSE: Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. MATERIALS AND METHODS: We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. RESULTS: Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. CONCLUSION: The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways.
Device Removal
;
Humans
;
Intubation, Intratracheal/instrumentation/*methods/standards
;
*Laryngeal Masks
;
Randomized Controlled Trials as Topic
;
Reference Standards
;
Risk
;
*Rotation
7.Evaluation of Endotracheal Intubation with a Flexible Fiberoptic Bronchoscope in Lateral Patient Positioning: A Prospective Randomized Controlled Trial.
Hui LI ; Wu WANG ; Ya-Ping LU ; Yan WANG ; Li-Hua CHEN ; Li-Pei LEI ; Xiang-Ming FANG
Chinese Medical Journal 2016;129(17):2045-2049
BACKGROUNDThere is an unmet need for a reliable method of airway management for patients in the lateral position. This prospective randomized controlled two-center study was designed to evaluate the feasibility of intubation using a flexible fiberoptic bronchoscope in the lateral position during surgery.
METHODSSeventy-two patients scheduled for elective nonobstetric surgery in the lateral decubitus position requiring tracheal intubation under general anesthesia at Lishui Central Hospital of Zhejiang Province and Jiaxing First Hospital of Zhejiang Province from April 1, 2015, to September 30, 2015, were enrolled in this study. Patients were randomly assigned to the supine position group (Group S, n = 38) and the lateral position group (Group L, n = 34). Experienced anesthetists performed tracheal intubation with a fiberoptic bronchoscope after general anesthesia. The time required for intubation, intubation success rates, and hemodynamic changes was recorded. Between-group differences were assessed using the Student's t-test, Mann-Whitney U-test, or Chi-square test.
RESULTSThe median total time to tracheal intubation was significantly longer in Group S (140.0 [135.8, 150.0] s) compared to Group L (33.0 [24.0, 38.8] s) (P < 0.01). The first-attempt intubation success rate was significantly higher in Group L (97%) compared to Group S (16%). Hemodynamic changes immediately after intubation were more exaggerated in Group S compared to Group L (P = 0.02).
CONCLUSIONEndotracheal intubation with a flexible fiberoptic bronchoscope may be an effective and timesaving technique for patients in the lateral position.
TRIAL REGISTRATIONChinese Clinical Trial Register, ChiCTR-IIR-16007814; http://www.chictr.org.cn/showproj.aspx?proj=13183.
Adult ; Aged ; Airway Management ; Bronchoscopes ; Equipment Design ; Female ; Fiber Optic Technology ; instrumentation ; methods ; Humans ; Intraoperative Complications ; prevention & control ; Intubation, Intratracheal ; instrumentation ; methods ; Male ; Middle Aged ; Patient Positioning ; Prospective Studies ; Young Adult
8.Awake tracheal intubation in a patient with a supraglottic mass with the Bonfils fibrescope after failed attempts with a flexible fibrescope.
Geoffrey LIEW ; Xin Fang LEONG ; Theodore WONG
Singapore medical journal 2015;56(8):e139-41
Awake intubation with a flexible fibrescope is usually done electively in patients with a known difficult airway. Herein, we describe the case of an elective awake tracheal intubation that was performed on a patient with a large, obstructive supraglottic mass. The intubation was successfully performed using the Bonfils fibrescope after several failed attempts with a flexible fibrescope. This case highlights the usefulness of the Bonfils fibrescope and the limitations of the flexible fibrescope in certain clinical situations.
Fiber Optic Technology
;
Humans
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngeal Neoplasms
;
diagnosis
;
Laryngoscopes
;
Laryngoscopy
;
instrumentation
;
Male
;
Middle Aged
;
Trachea
;
Tracheostomy
;
methods
;
Wakefulness
9.Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients.
Amro Faez ABDELGAWAD ; Qin-Fang SHI ; Mohamed Abo HALAWA ; Zhi-Lin WU ; Zhou-Yang WU ; Xiang-Dong CHEN ; Shang-Long YAO
Journal of Huazhong University of Science and Technology (Medical Sciences) 2015;35(3):432-438
Tracheal intubation with Macintosh laryngoscope (MAC) might result in severe cardiovascular complications. The results of conducted studies investigating the effects of videolaryngoscopies on hemodynamic response of tracheal intubation are conflicting. We know little about the effects of videolaryngoscopies on cardiac output changes during tracheal intubation. We compared cardiac output (COP) and hemodynamic responses in normal blood pressure (n=60) and hypertensive patients (n=60) among 3 intubation devices: the MAC, the UE videolaryngoscopy ® (UE), and the UE video intubation stylet ® (VS). Cardiac index (CI), stroke volume index (SVI), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded using LidcoRapid (V2)® preinduction, preintubation, and every minute for the first 5 min after intubation. We assessed oropharyngeal and laryngeal structures injury as well. Intubation time was significantly shorter than MAC groups (P<0.001) only in UE group of normotensive and hypertensive patients. In normotensive patients, there were no significant differences in any of COP variables or hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the MAC group were significantly higher (P<0.05 or <0.01) than the UE and VS groups at 1, 2 and 3 min after intubation, but there were no significant differences in CI, SVI and HR among the three devices. There was no significant difference in oropharyngeal and laryngeal structures injury among all groups. It was concluded that both the UE and VS attenuate only the hemodynamic response to intubation as compared with the MAC in hypertensive patients, but not in normotensive patients.
Adult
;
Aged
;
Blood Pressure
;
physiology
;
Cardiac Output
;
physiology
;
Female
;
Hemodynamics
;
Humans
;
Hypertension
;
physiopathology
;
surgery
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopy
;
instrumentation
;
methods
;
Larynx
;
anatomy & histology
;
injuries
;
Male
;
Middle Aged
;
Oropharynx
;
anatomy & histology
;
injuries
;
Video-Assisted Surgery
;
methods
;
Young Adult
10.Study on Tracheal Intubation's Circular Arc Radius Measuring Method Based on Machine Vision.
Dong YU ; Genchi LI ; Yunhao FENG ; Yonghuan YANG ; Xiali HAO
Chinese Journal of Medical Instrumentation 2015;39(3):206-215
It is difficult to measure the circular arc radius for central angle less than 30 degrees. The existing measuring methods are of low efficiency and big error. Through designing the machine vision system and studying the image detecting method for measurement, It is obtained good results by using the new measurement for tracheal intubation's circular arc radius, Realized a rapid and accurate measurement of the circular arc radius, and expanded the application in the field of machine vision.
Humans
;
Imaging, Three-Dimensional
;
instrumentation
;
Intubation
;
Trachea

Result Analysis
Print