1.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
2.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
3.Fatty liver index and development of lung cancer: a nationwide cohort study
Jihye LIM ; Bongseong KIM ; Kyungdo HAN ; Jeong Uk LIM
The Korean Journal of Internal Medicine 2025;40(2):275-285
Background/Aims:
This study aimed to evaluate the impact of steatotic liver disease severity on the cumulative incidence of lung cancer utilizing data from the Korea National Health Insurance Service (NHIS).
Methods:
This study examined the risk of lung cancer in the general population in conjunction with the incidence of steatotic liver disease. The study population consisted of 3,261,438 individuals aged 20 years or older who underwent a general health examination in 2009.
Results:
Individuals with fatty liver index (FLI) of 30–59 exhibited a 1.08-fold increased risk of lung cancer (95% CI: 1.04–1.11), while FLI ≥ 60 was associated with a 1.22-fold elevated risk of lung cancer (95% CI: 1.17–1.28) compared to those with FLI < 30. The risk varied with smoking status; in current smokers, the adjusted HR for the FLI 30–59 group was 1.05 (95% CI: 1.00–1.10), while that in the FLI ≥ 60 group was 1.11 (95% CI: 1.04–1.18). In never- or past-smokers, the adjusted HR for the FLI 30–59 group was 1.10, and that for the FLI ≥ 60 group was 1.31. Subgroup analysis revealed an incidence rate of 1.06 per 1,000 person-years in the consistently high FLI group compared to 1.15 in those with improved FLI. Improving FLI over time was associated with a 0.93-fold decrease in lung cancer risk.
Conclusions
Our study demonstrated a correlational relationship between lung cancer incidence and the severity of steatotic liver disease as measured by FLI.
4.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
5.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
6.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
7.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
8.Fatty liver index and development of lung cancer: a nationwide cohort study
Jihye LIM ; Bongseong KIM ; Kyungdo HAN ; Jeong Uk LIM
The Korean Journal of Internal Medicine 2025;40(2):275-285
Background/Aims:
This study aimed to evaluate the impact of steatotic liver disease severity on the cumulative incidence of lung cancer utilizing data from the Korea National Health Insurance Service (NHIS).
Methods:
This study examined the risk of lung cancer in the general population in conjunction with the incidence of steatotic liver disease. The study population consisted of 3,261,438 individuals aged 20 years or older who underwent a general health examination in 2009.
Results:
Individuals with fatty liver index (FLI) of 30–59 exhibited a 1.08-fold increased risk of lung cancer (95% CI: 1.04–1.11), while FLI ≥ 60 was associated with a 1.22-fold elevated risk of lung cancer (95% CI: 1.17–1.28) compared to those with FLI < 30. The risk varied with smoking status; in current smokers, the adjusted HR for the FLI 30–59 group was 1.05 (95% CI: 1.00–1.10), while that in the FLI ≥ 60 group was 1.11 (95% CI: 1.04–1.18). In never- or past-smokers, the adjusted HR for the FLI 30–59 group was 1.10, and that for the FLI ≥ 60 group was 1.31. Subgroup analysis revealed an incidence rate of 1.06 per 1,000 person-years in the consistently high FLI group compared to 1.15 in those with improved FLI. Improving FLI over time was associated with a 0.93-fold decrease in lung cancer risk.
Conclusions
Our study demonstrated a correlational relationship between lung cancer incidence and the severity of steatotic liver disease as measured by FLI.
9.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
10.Constitutional Chromosome 21 Abnormality in B-ALL with iAMP21 in a Patient Developing Treatment-Related Myelodysplastic Syndrome
Inhwa KIM ; Su Hyun YOON ; Sunghan KANG ; Kyung-Nam KOH ; Mi Young KIM ; Young-Uk CHO ; Sang-Hyun HWANG ; Seongsoo JANG ; Eul-Ju SEO ; Beom Hee LEE ; Sunghee MIN ; Hyunwoo BAE ; Ho Joon IM ; Hyery KIM
Clinical Pediatric Hematology-Oncology 2025;32(1):23-28
The initial molecular cytogenetic characteristics of blasts plays a significant role in determining the treatment course of B-cell acute lymphoblastic leukemia (B-ALL).B-ALL with intrachromosomal amplification of chromosome 21 (iAMP21) has been well known to have unfavorable prognosis. Also, there are previously recognized germline mutations that increase the risk of ALL, such as trisomy 21, Down syndrome. This case report is about a 16-year-old girl who presented with lymphadenitis, purpura, and fever followed by initial lab of elevated white blood cell with blasts.She had some notable facial features, but no typical Down syndrome related one.Bone marrow biopsy and fluorescence in situ hybridization finalized the diagnosis as B-ALL with iAMP21, high-risk group. The minimal residual disease-negative complete remission was achieved after the induction chemotherapy with Korean multicenter high-risk protocol. However, abnormal karyotype was sustained in bone marrow. Microarrays with her buccal swab raised the possibility that the abnormal karyotype was not from the leukemic blasts but rather from the germline. Although she underwent scheduled chemotherapy uneventfully as slow early responder type, thrombocytopenia and abnormal karyotype persisted, leading to the diagnosis of acute myeloid leukemia. Additional chemotherapy and peripheral blood stem cell transplantation was performed which resulted in engraftment. This case highlights the discovery of a constitutional genetic aberration, which played like a silent yet critical background factor for B-ALL with iAMP21. As the number of reported cases are limited, the role of germline chromosome 21 mutation as the indicator for prognosis of B-ALL should be studied further.