1.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
4.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
5.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
6.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
7.Erratum to: Corrigendum: 2023 Korean Society of Menopause -Osteoporosis Guidelines Part I
Dong Ock LEE ; Yeon Hee HONG ; Moon Kyoung CHO ; Young Sik CHOI ; Sungwook CHUN ; Youn-Jee CHUNG ; Seung Hwa HONG ; Kyu Ri HWANG ; Jinju KIM ; Hoon KIM ; Dong-Yun LEE ; Sa Ra LEE ; Hyun-Tae PARK ; Seok Kyo SEO ; Jung-Ho SHIN ; Jae Yen SONG ; Kyong Wook YI ; Haerin PAIK ; Ji Young LEE
Journal of Menopausal Medicine 2024;30(3):179-179
8.Evaluation of Erosive Potential of Powdered Vitamin C on Bovine Teeth
Ha-Rin KIM ; Im-Hee JUNG ; Ye-Jin KIM ; Na-Ra MIN ; Ye-Jin SEO ; Yeo-Jin LEE ; Eun-Bi LEE ; Su-Min HAN ; Hee-Jung LIM ; Do-Seon LIM
Journal of Dental Hygiene Science 2024;24(4):391-399
Background:
This study aimed to investigate the erosive potential of powdered vitamin C on the bovine enamel tooth surface.
Methods:
The experiment included five groups: Lemona, Vitagran, Korea Eundan, Coca-Cola (positive controls), and artificialsaliva (negative controls). The pH and titratable acidity were measured. Bovine enamel specimens were immersed in the experimental solutions for 15 minutes each day for 7 days. The surface microhardness was measured using the Vickers hardness number before immersion and on the 1st, 3rd, 5th, and 7th days. The surfaces of the bovine enamel specimens were observed by scanning electron microscopy (SEM).
Results:
The pH of the experimental groups was as follows: Lemona (2.04±0.04) had the lowest pH, followed by Vitagran(2.56±0.01), the positive control group Coca-Cola (2.60±0.03), Korea Eundan (3.14±0.02), and the negative control group artificial saliva (7.06±0.05). Surface microhardness decreased significantly during the immersion period (p<0.001). The largest surface microhardness reduction value was shown in Lemona (–201.22±20.60), followed by Vitagran (–190.02±14.73), Korea Eundan (–189.27±27.14), Coca-Cola (–99.28±17.21), artificial saliva (–10.99±9.94). According to the SEM findings, the experimental and positive control groups exhibited rough surfaces with micropores, whereas the negative control group exhibited smooth surfaces before specimen immersion.
Conclusion
Consuming powdered vitamin C at a low pH may degrade the enamel surface. To reduce the erosive effect, it isrecommended to rinse the mouth with water and brush the teeth after an hour.
9.Conical double crown removable partial denture using facial scan and digital diagnostic template
Seong-Min SON ; Min-Kyung SEO ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
Journal of Dental Rehabilitation and Applied Science 2024;40(4):257-267
Partially edentulous patients with a crossed occlusion have poor denture support, retention, and stability. Moreover, residual abutments showed a poor prognosis due to denture rotation. The use of a conical double crown removable partial denture to establish proper horizontal and vertical interocclusal relationships, it can establish a stable occlusal plane and occlusal contacts providing a sufficient restorative space and a favorable functional and aesthetic outcome. In this case, a patient with an anteriorposterior crossed occlusion with mandibular prognathism and no occluding teeth in habitual centric position was treated with a conical double crown removable partial denture. After diagnostic cast analysis and digital diagnosis, provisional prosthesis templates were fabricated. It was possible to intuitive and appropriate vertical dimension determination and esthetic evaluation were performed. Definitive prosthesis with proper function and aesthetics can be fabricated by the digital and conventional treatment process.
10.Prevalence of temporomandibular disorder in Korea: a nationwide population-based study
Shin Yi JANG ; Su Ra SEO ; Seong Kyong KIM ; Kyeongsug KIM
Precision and Future Medicine 2024;8(2):50-55
Purpose:
Few studies have assessed the prevalence of temporomandibular disorders (TMD) in the Korean population.
Methods:
We used cohort data from the Korean National Health Insurance Service between 2012 and 2020. The data consisted of main diagnoses related to TMD (International Classification of Diseases 10th Revision [ICD-10] code: K07.6 and K07.6x). The age-standardized prevalence of TMD was calculated using the estimated Korean population in 2020 as a reference.
Results:
The age-standardized prevalence of TMD increased from 604 persons per 100,000 persons in 2012 to 869 persons in 2020. In 2020, the overall age-standardized prevalence was 1,355 persons in the 10 to 19 years age group, 1,809 persons in the 20 to 29 years age group, and 979 persons in the 30 to 39 years age group. The age-standardized prevalence was approximately 1.5 times higher in females than in males (698 persons in males vs. 1,040 persons in females). Among the specific TMD subtypes, the age-standardized prevalence of internal derangement of the temporomandibular joint and pain in the temporomandibular joint, not classified elsewhere, was higher than that of other specific TMDs.
Conclusion
The overall age-standardized prevalence of TMD was higher in the 10s, 20s, and 30s age groups and in females between 2012 and 2020. The age-standardized prevalence of internal derangement of temporomandibular joint was the highest among specific TMD subtypes.

Result Analysis
Print
Save
E-mail