1.High-quality reconstruction of four-dimensional cone beam CT from motion registration prior image.
Meiling CHEN ; Yi HUANG ; Wufan CHEN ; Xin CHEN ; Hua ZHANG
Journal of Southern Medical University 2019;39(2):201-206
Four-dimensional cone beam CT (4D-CBCT) imaging can provide accurate location information of real-time breathing for imaging-guided radiotherapy. How to improve the accuracy of 4D-CBCT reconstruction image is a hot topic in current studies. PICCS algorithm performs remarkably in all 4D-CBCT reconstruction algorithms based on CS theory. The improved PICCS algorithm proposed in this paper improves the prior image on the basis of the traditional PICCS algorithm. According to the location information of each phase, the corresponding prior image is constructed, which completely eliminates the motion blur of the reconstructed image caused by the mismatch of the projection data. Meanwhile, the data fidelity model of the proposed method is consistent with the traditional PICCS algorithm. The experimental results showed that the reconstructed image using the proposed method had a clearer organization boundary compared with that of images reconstructed using the traditional PICCS algorithm. This proposed method significantly reduced the motion artifact and improved the image resolution.
Algorithms
;
Cone-Beam Computed Tomography
;
methods
;
Four-Dimensional Computed Tomography
;
Humans
;
Image Processing, Computer-Assisted
;
Organ Motion
;
Radiographic Image Enhancement
;
instrumentation
;
methods
;
Respiration
2.Design and optimization of a cone-beam CT system for extremity imaging.
Kun MA ; Mingqiang LI ; Xi TAO ; Dong ZENG ; Yongbo WANG ; Zhaoying BIAN ; Ziquan WEI ; Gaofeng CHEN ; Qianjin FENG ; Jianhua MA ; Jing HUANG
Journal of Southern Medical University 2018;38(11):1331-1337
OBJECTIVE:
To establish a cone beam computed tomography (ECBCT) system for high-resolution imaging of the extremities.
METHODS:
Based on three-dimensional X-Ray CT imaging and high-resolution flat plate detector technique, we constructed a physical model and a geometric model for ECBCT imaging, optimized the geometric calibration and image reconstruction methods, and established the scanner system. In the experiments, the pencil vase phantom, image quality (IQ) phantom and a swine feet were scanned using this imaging system to evaluate its effectiveness and stability.
RESULTS:
On the reconstructed image of the pencil vase phantom, the edges were well preserved with geometric calibrated parameters and no aliasing artifacts were observed. The reconstructed images of the IQ phantom showed a uniform distribution of the CT number, and the noise power spectra were stable in multiple scanning under the same condition. The reconstructed images of the swine feet had clearly displayed the bones with a good resolution.
CONCLUSIONS
The ECBCT system can be used for highresolution imaging of the extremities to provide important imaging information to assist in the diagnosis of bone diseases.
Algorithms
;
Animals
;
Artifacts
;
Calibration
;
Cone-Beam Computed Tomography
;
instrumentation
;
methods
;
Equipment Design
;
Extremities
;
diagnostic imaging
;
Image Processing, Computer-Assisted
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
instrumentation
;
methods
;
Swine
3.Development of Lung Compression Degree Measurement Software of Pneumothorax and Its Application in Forensic Medicine.
Yong Bo WU ; Bin WU ; Yang LI ; Xiao Fei HU ; Dong Lei SI
Journal of Forensic Medicine 2018;34(3):260-263
OBJECTIVES:
To develop a measurement software of lung compression degree to calculate the lung compression ratio in pneumothorax patients accurately and quickly, and then provide an objective assessment of damage degree in forensic clinical identification.
METHODS:
A volume calculation software was established according to the working principle of the CT instrument. CT data of 15 pneumothorax patients were selected as research objects. The lung compression ratio of pneumothorax patient was calculated by the lung compression volume calculation software of the CT instrument. Meanwhile, the lung compression ratio was also calculated by the developed volume calculation software. The lung compression ratio and operation time calculated by the two methods were analyzed statistically. Scatter plot graphs were draw based on related data, and the developed volume calculation software was verified.
RESULTS:
The difference between the lung compression ratios calculated by the two methods was not statistically significant, but showed a linear correlation (P<0.05). The operation time of the developed volume calculation software was obviously shorter.
CONCLUSIONS
The volume calculation software developed in this study can calculate the lung compression degree of pneumothorax more conveniently and rapidly with easy accessibility, which shows an application value in the forensic practice.
Forensic Medicine/instrumentation*
;
Humans
;
Image Processing, Computer-Assisted/methods*
;
Lung/diagnostic imaging*
;
Pneumothorax
;
Software
;
Tomography, X-Ray Computed
4.Advances in Multidetector CT Diagnosis of Pediatric Pulmonary Thromboembolism.
Korean Journal of Radiology 2016;17(2):198-208
Although pediatric pulmonary thromboembolism is historically believed to be rare with relatively little information available in the medical literature regarding its imaging evaluation, it is more common than previously thought. Thus, it is imperative for radiologists to be aware of the most recent advances in its imaging information, particularly multidetector computed tomography (MDCT), the imaging modality of choice in the pediatric population. The overarching goal of this article is to review the most recent updates on MDCT diagnosis of pediatric pulmonary thromboembolism.
Humans
;
Image Processing, Computer-Assisted
;
Multidetector Computed Tomography/instrumentation/*methods
;
Pediatrics
;
Pulmonary Embolism/physiopathology/*radiography
;
Risk Factors
5.Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle.
Yeon Hwa YOO ; Hak Sun KIM ; Young Han LEE ; Choon Sik YOON ; Mun Young PAEK ; Hanna YOO ; Stephan KANNENGIESSER ; Tae Sub CHUNG ; Ho Taek SONG ; Jin Suck SUH ; Sungjun KIM
Korean Journal of Radiology 2015;16(5):1086-1095
OBJECTIVE: To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. MATERIALS AND METHODS: Sixty patients with low back pain underwent MR imaging with a 1.5T scanner. FF mapping images automatically obtained using T2*-corrected Dixon technique with two (non-T2*-corrected), three, and six echoes, were compared with images from single-voxel MR spectroscopy at the paravertebral muscles on levels L4 through L5. FFs were measured directly by two radiologists, who independently drew the region of interest on the mapping images from the three sequences. RESULTS: A total of 117 spectroscopic measurements were performed either bilaterally (57 of 60 subjects) or unilaterally (3 of 60 subjects). The mean spectroscopic FF was 14.3 +/- 11.7% (range, 1.9-63.7%). Interobserver agreement was excellent between the two radiologists. Lin's concordance correlation between the spectroscopic findings and all the imaging-based FFs were statistically significant (p < 0.001). FFs obtained from the T2*-corrected six-echo Dixon sequences showed a significantly better concordance with the spectroscopic data, with its concordance correlation coefficient being 0.99 and 0.98 (p < 0.001), as compared with two- or three-echo methods. CONCLUSION: T2*-corrected six-echo Dixon sequence would be a better option than two- or three-echo methods for noninvasive quantification of lumbar muscle fat quantification.
Adult
;
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Image Processing, Computer-Assisted
;
Low Back Pain/*radiography
;
Magnetic Resonance Imaging/instrumentation/*methods
;
Male
;
Middle Aged
;
Muscles/radiography
;
Spinal Cord
6.Biomechanical characteristics of hip prosthesis in hip arthroplasty treating elderly patients with Evans I-III intertrochanteric fracture of femur.
Wen-guang LIU ; Sheng-hou LIU ; Qing-feng YIN ; Shi-peng XIAO ; Shao-jin WANG
Acta Academiae Medicinae Sinicae 2013;35(1):108-111
OBJECTIVETo investigate the feasibility of hip arthroplasty in the treatment of elderly patients with Evans I-III intertrochanteric fracture of femur by analyzing its biomechanics characters.
METHODSWe solved the CT digital image files with the graphics processing software Mimics at DICOM 3.0 standard, and reconstructed the three-dimensional entity of femur with CAD modeling software Unigraphics. Then the fracture line was defined in the model as the line between the tip of greater trochanter and inferior margin of small trochanter, above which the upper bone was removed. Afterwards the two prosthesises with different stem lengths (120 mm and 170 mm) were implanted into the fracture model respectively as hip arthroplasty with 3 mm bone cement layer between prosthesis and femur, and the bone defect was repatched with 5 mm bone cement layer. A three-dimensional finite element model was established with finite element analysis software ABAQUS 6.5. We formulated different material parameters under the stress condition standing with single leg to build the stress distribution map of the femur prosthesis, and took 5 loci of region of stress concentration to calculate the mean value of stress.
RESULTSThe stress distribution maps of the short and long stem length prothesises were similar. And there were two areas of stress concentration, including the upper portion and the lower portion close to the joint of the prosthesis stem, and the stress concentration in the junction part was obviously between the lower portion and the upper area of the small trachanter. The stress reached the first concentration area at the junction and then gradually reached the second concentration area at the interior terminal of the stem. While the stress gradually increased along the lateral prosthesis stem, and reached the stress concentration area at the end.
CONCLUSIONSThe stress distribution maps in the femur prosthesises are similar between hip arthroplasty in the treatment of intertrochanteric fracture of femur and the traditional hip arthroplasty surgery. The peak stress values are higher in the long stem prosthesis in the treatment of intertrochanteric fracture of femur than the short type, while they are under the rupture value of the metal.
Aged ; Arthroplasty, Replacement, Hip ; instrumentation ; methods ; Biomechanical Phenomena ; Bone Cements ; Computer Simulation ; Female ; Finite Element Analysis ; Hip Fractures ; surgery ; Hip Prosthesis ; Humans ; Image Processing, Computer-Assisted ; Software ; Stress, Mechanical
7.Self-adaptive beamforming method based on plane wave ultrasound imaging.
Longlong ZHANG ; Hao ZHOU ; Yinfei ZHENG ; Xiaohong GONG ; Jianping WANG
Journal of Biomedical Engineering 2013;30(4):843-853
In order to improve the resolution, contrast and frame rate of ultrasound imaging, it is necessary to design an adaptive beamforming method for plane wave ultrasound imaging. An optimized minimum variance algorithm that suits plane wave ultrasound imaging was proposed, based on the traditional minimum variance algorithm that combines with the subband beamforming as well as the forward-backward spatial smoothing method in the frequency domain. To verify the effectiveness of the improved algorithm, the matlab software was used. Simulation results showed that full width at half maximum and peak side-lobe level of Optimized MV, Conventional MV, DAS boxcar, and Linear scan methods were 0.08, 0.36, 0.92, 1.42 dB, and -41.1, - 37.3, -16.9, - 34.1 dB, respectively. The improved algorithm can significantly improve the image resolution and contrast, particularly applicable to plane wave ultrasound imaging, compared with the conventional minimum variance algorithm and traditional delay-and-sum method.
Algorithms
;
Contrast Media
;
Image Enhancement
;
Image Processing, Computer-Assisted
;
methods
;
Microbubbles
;
Phantoms, Imaging
;
Ultrasonography
;
instrumentation
;
methods
8.Intraoperative Near Infrared Fluorescence Imaging in Robotic Low Anterior Resection: Three Case Reports.
Sung Uk BAE ; Se Jin BAEK ; Hyuk HUR ; Seung Hyuk BAIK ; Nam Kyu KIM ; Byung Soh MIN
Yonsei Medical Journal 2013;54(4):1066-1069
The recent introduction of an intraoperative near infrared fluorescence (INIF) imaging system installed on the da Vinci Si(R) robotic system has enabled surgeons to identify intravascular NIF signals in real time. This technology is useful in identifying hidden vessels and assessing blood supply to bowel segments. In this study, we report 3 cases of patients with rectal cancer who underwent robotic low anterior resection (LAR) with INIF imaging for the first time in Asia. In September 2012, robotic-assisted rectal resection with INIF imaging was performed on three consecutive rectal cancer patients. LAR was performed in 2 cases, and abdominoperineal resection was performed in the third case. INIF imaging was used to identify the left colic branch of the inferior mesenteric artery and to assess blood supply to the distal rectum. We evaluated the utility of INIF imaging in performing robotic-assisted colorectal procedures. Our preliminary results suggest that this technique is safe and effective, and that INIF imaging may be a useful tool to colorectal surgeons.
Aged
;
Digestive System Surgical Procedures/*methods
;
Female
;
Fluorescence
;
Humans
;
Image Processing, Computer-Assisted/instrumentation/*methods
;
*Intraoperative Care
;
Male
;
Middle Aged
;
Rectal Neoplasms/*surgery
;
Rectum/*surgery
;
Robotics/*methods
;
Spectroscopy, Near-Infrared/*methods
;
Treatment Outcome
9.Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study.
Hideyuki SUENAGA ; Huy Hoang TRAN ; Hongen LIAO ; Ken MASAMUNE ; Takeyoshi DOHI ; Kazuto HOSHI ; Yoshiyuki MORI ; Tsuyoshi TAKATO
International Journal of Oral Science 2013;5(2):98-102
To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (<1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye.
Calibration
;
Data Display
;
Feasibility Studies
;
Humans
;
Image Processing, Computer-Assisted
;
instrumentation
;
methods
;
Imaging, Three-Dimensional
;
methods
;
Mandible
;
anatomy & histology
;
Maxilla
;
anatomy & histology
;
Models, Anatomic
;
Optical Devices
;
Oral Surgical Procedures
;
instrumentation
;
methods
;
Pilot Projects
;
Stereotaxic Techniques
;
instrumentation
;
Surgery, Computer-Assisted
;
instrumentation
;
methods
;
Tomography, X-Ray Computed
;
methods
;
Tooth
;
anatomy & histology
;
User-Computer Interface
;
Video Recording
;
instrumentation
;
methods
10.Enhancement of image used in optical imaging of intrinsic signal.
Journal of Biomedical Engineering 2012;29(1):137-142
Optical imaging of intrinsic signals is a secondary image of the cerebral cortex. The weak optical signal is decided by anatomical structure of brain. The spatial filter is a powerful technology for de-noising and image enhancement. We used different linear and nonlinear filters to deal with optical imaging. Furthermore, we compared the degree of noise suppression and discussed the image details. Our result showed that nonlinear median filter can keep more image details with effective noise reduction. It is useful for image enhancement of optical imaging.
Animals
;
Artifacts
;
Blood Vessels
;
anatomy & histology
;
Cats
;
Cerebral Cortex
;
anatomy & histology
;
physiology
;
Cerebrovascular Circulation
;
physiology
;
Female
;
Image Enhancement
;
methods
;
Image Processing, Computer-Assisted
;
instrumentation
;
methods
;
Male
;
Optical Imaging
;
methods
;
Photic Stimulation

Result Analysis
Print
Save
E-mail