1.High-quality reconstruction of four-dimensional cone beam CT from motion registration prior image.
Meiling CHEN ; Yi HUANG ; Wufan CHEN ; Xin CHEN ; Hua ZHANG
Journal of Southern Medical University 2019;39(2):201-206
Four-dimensional cone beam CT (4D-CBCT) imaging can provide accurate location information of real-time breathing for imaging-guided radiotherapy. How to improve the accuracy of 4D-CBCT reconstruction image is a hot topic in current studies. PICCS algorithm performs remarkably in all 4D-CBCT reconstruction algorithms based on CS theory. The improved PICCS algorithm proposed in this paper improves the prior image on the basis of the traditional PICCS algorithm. According to the location information of each phase, the corresponding prior image is constructed, which completely eliminates the motion blur of the reconstructed image caused by the mismatch of the projection data. Meanwhile, the data fidelity model of the proposed method is consistent with the traditional PICCS algorithm. The experimental results showed that the reconstructed image using the proposed method had a clearer organization boundary compared with that of images reconstructed using the traditional PICCS algorithm. This proposed method significantly reduced the motion artifact and improved the image resolution.
Algorithms
;
Cone-Beam Computed Tomography
;
methods
;
Four-Dimensional Computed Tomography
;
Humans
;
Image Processing, Computer-Assisted
;
Organ Motion
;
Radiographic Image Enhancement
;
instrumentation
;
methods
;
Respiration
2.Key technologies in digital breast tomosynthesis system:theory, design, and optimization.
Mingqiang LI ; Kun MA ; Xi TAO ; Yongbo WANG ; Ji HE ; Ziquan WEI ; Geofeng CHEN ; Sui LI ; Dong ZENG ; Zhaoying BIAN ; Guohui WU ; Shan LIAO ; Jianhua MA
Journal of Southern Medical University 2019;39(2):192-200
OBJECTIVE:
To develop a digital breast tomosynthesis (DBT) imaging system with optimizes imaging chain.
METHODS:
Based on 3D tomography and DBT imaging scanning, we analyzed the methods for projection data correction, geometric correction, projection enhancement, filter modulation, and image reconstruction, and established a hardware testing platform. In the experiment, the standard ACR phantom and high-resolution phantom were used to evaluate the system stability and noise level. The patient projection data of commercial equipment was used to test the effect of the imaging algorithm.
RESULTS:
In the high-resolution phantom study, the line pairs were clear without confusing artifacts in the images reconstructed with the geometric correction parameters. In ACR phantom study, the calcified foci, cysts, and fibrous structures were more clearly defined in the reconstructed images after filtering and modulation. The patient data study showed a high contrast between tissues, and the lesions were more clearly displayed in the reconstructed image.
CONCLUSIONS
This DBT imaging system can be used for mammary tomography with an image quality comparable to that of commercial DBT systems to facilitate imaging diagnosis of breast diseases.
Algorithms
;
Artifacts
;
Breast
;
diagnostic imaging
;
Female
;
Humans
;
Mammography
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
methods
3.Super-resolution construction of intravascular ultrasound images using generative adversarial networks.
Yangyang WU ; Feng YANG ; Jing HUANG ; Yaqin LIU
Journal of Southern Medical University 2019;39(1):82-87
The low-resolution ultrasound images have poor visual effects. Herein we propose a method for generating clearer intravascular ultrasound images based on super-resolution reconstruction combined with generative adversarial networks. We used the generative adversarial networks to generate the images by a generator and to estimate the authenticity of the images by a discriminator. Specifically, the low-resolution image was passed through the sub-pixel convolution layer -feature channels to generate -feature maps in the same size, followed by realignment of the corresponding pixels in each feature map into × sub-blocks, which corresponded to the sub-block in a high-resolution image; after amplification, an image with a -time resolution was generated. The generative adversarial networks can obtain a clearer image through continuous optimization. We compared the method (SRGAN) with other methods including Bicubic, super-resolution convolutional network (SRCNN) and efficient sub-pixel convolutional network (ESPCN), and the proposed method resulted in obvious improvements in the peak signal-to-noise ratio (PSNR) by 2.369 dB and in structural similarity index by 1.79% to enhance the diagnostic visual effects of intravascular ultrasound images.
Blood Vessels
;
diagnostic imaging
;
Endosonography
;
methods
;
Image Enhancement
;
methods
;
Image Processing, Computer-Assisted
;
methods
;
Signal-To-Noise Ratio
4.Method for Automated Selection of the Trabecular Area in Digital Periapical Radiographic Images Using Morphological Operations
Enny Itje SELA ; Reza PULUNGAN ; Rini WIDYANINGRUM ; Rurie Ratna SHANTININGSIH
Healthcare Informatics Research 2019;25(3):193-200
OBJECTIVES: The aim of this study is to propose a method that automatically select the trabecular bone area in digital periapical radiographic images using a sequence of morphological operations. METHODS: The study involved 50 digital periapical radiographic images of women aged from 36 to 58 years old. The proposed method consists of three stages: teeth detection, trabecular identification, and validation. A series of morphological operations-top-hat and bottom-hat filtering, automatic thresholding, closing, labeling, global thresholding, and image subtraction-are performed to automatically obtain the trabecular bone area in images. For validation, the results of the proposed method were compared with those of two dentists pixel by pixel. Three parameters were used in the validation: trabecular area, percentage of agreed area, and percentage of disagreed area. RESULTS: The proposed method obtains the trabecular bone area in a polygon. The obtained trabecular bone area is usually larger than that of previous studies, but is usually smaller than the dentists'. On average over all images, the trabecular area produced by the proposed method is 5.83% smaller than that identified by dentists. Furthermore, the average percentage of agreed area and the average percentage of disagreed area of the proposed method against the dentists' results were 75.22% and 8.75%, respectively. CONCLUSIONS: The shape of the trabecular bone area produced by the proposed method is similar and closer to that identified by dentists. The method, which consists of only simple morphological operations on digital periapical radiographic images, can be considered for selecting the trabecular bone area automatically.
Dentists
;
Female
;
Humans
;
Image Enhancement
;
Methods
;
Radiography
;
Tooth
5.Design and optimization of a cone-beam CT system for extremity imaging.
Kun MA ; Mingqiang LI ; Xi TAO ; Dong ZENG ; Yongbo WANG ; Zhaoying BIAN ; Ziquan WEI ; Gaofeng CHEN ; Qianjin FENG ; Jianhua MA ; Jing HUANG
Journal of Southern Medical University 2018;38(11):1331-1337
OBJECTIVE:
To establish a cone beam computed tomography (ECBCT) system for high-resolution imaging of the extremities.
METHODS:
Based on three-dimensional X-Ray CT imaging and high-resolution flat plate detector technique, we constructed a physical model and a geometric model for ECBCT imaging, optimized the geometric calibration and image reconstruction methods, and established the scanner system. In the experiments, the pencil vase phantom, image quality (IQ) phantom and a swine feet were scanned using this imaging system to evaluate its effectiveness and stability.
RESULTS:
On the reconstructed image of the pencil vase phantom, the edges were well preserved with geometric calibrated parameters and no aliasing artifacts were observed. The reconstructed images of the IQ phantom showed a uniform distribution of the CT number, and the noise power spectra were stable in multiple scanning under the same condition. The reconstructed images of the swine feet had clearly displayed the bones with a good resolution.
CONCLUSIONS
The ECBCT system can be used for highresolution imaging of the extremities to provide important imaging information to assist in the diagnosis of bone diseases.
Algorithms
;
Animals
;
Artifacts
;
Calibration
;
Cone-Beam Computed Tomography
;
instrumentation
;
methods
;
Equipment Design
;
Extremities
;
diagnostic imaging
;
Image Processing, Computer-Assisted
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
instrumentation
;
methods
;
Swine
6.Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth
Luciano Andrei FRANCIO ; Fernanda Evangelista SILVA ; Claudia Scigliano VALERIO ; Claudia Assunção e Alves CARDOSO ; Wellington Corrêa JANSEN ; Flávio Ricardo MANZI
Imaging Science in Dentistry 2018;48(2):87-95
PURPOSE: The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. RESULTS: For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P < .05). CBCT images exhibited good results for resin restorations (P>.05), but showed no discriminatory ability for amalgam restorations (P < .05). CONCLUSION: Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.
Biomedical and Dental Materials
;
Cone-Beam Computed Tomography
;
Dental Amalgam
;
Humans
;
Methods
;
Microscopy
;
Molar
;
Radiographic Image Enhancement
;
Radiography
;
ROC Curve
;
Tooth
7.Role of Diffusion-weighted and Contrast-enhanced Magnetic Resonance Imaging in Differentiating Activity of Ankylosing Spondylitis.
Ying-Hua ZHAO ; Yan-Yan CAO ; Qun ZHANG ; Ying-Jie MEI ; Ji-Jie XIAO ; Shao-Yong HU ; Wei LI ; Shao-Lin LI
Chinese Medical Journal 2017;130(11):1303-1308
BACKGROUNDPrevious studies showed that combining apparent diffusion coefficient (ADC) value with the Spondyloarthritis Research Consortium of Canada (SPARCC) index value might provide a reliable evaluation of the activity of ankylosing spondylitis (AS), and that contrast-enhanced (CE) magnetic resonance imaging (MRI) is unnecessary. However, the results were based on confirming only a small random sample. This study aimed to assess the role of CE-MRI in differentiating the disease activity of AS by comparing ADC value with a large sample.
METHODSA total of 115 patients with AS were enrolled in accordance with Bath AS Disease Activity Index and laboratory indices, and 115 patients were divided into two groups, including active group (n = 69) and inactive group (n = 46). SPARCC, ΔSI, and ADC values were obtained from the short tau inversion recovery (STIR), diffusion-weighted imaging (DWI), and CE-MRI, respectively. One-way analysis of variance and receiver operating characteristic analysis were performed for all parameters.
RESULTSThe optimal cutoff values (with sensitivity, specificity, respective area under the curve, positive likelihood ratio, and negative likelihood ratio) for the differentiation between active and inactive groups are as follows: SPARCC = 6 (72.06%, 82.61%, 0.836, 4.14, 0.34); ΔSI (%) = 153 (80.6%, 84.78%, 0.819, 5.3, 0.23); ADC value = 1.15 × 10-3 mm2/s (72.73%, 81.82%, 0.786, 4, 0.33). No statistical differences were found among the predictive values of SPARCC, ΔSI, and ADC. Multivariate analysis showed no significant difference between the combination of SPARCC and ADC values with and without ΔSI.
CONCLUSIONSUsing large sample, we concluded that the combination of STIR and DWI would play significant roles in assessing the disease activity, and CE-MRI sequence is not routinely used in imaging of AS to avoid renal fibrosis and aggravation of kidney disease.
Adolescent ; Adult ; Contrast Media ; Diagnosis, Differential ; Diffusion Magnetic Resonance Imaging ; methods ; Female ; Humans ; Image Enhancement ; methods ; Magnetic Resonance Imaging ; methods ; Male ; Middle Aged ; ROC Curve ; Sensitivity and Specificity ; Spondylitis, Ankylosing ; diagnostic imaging ; physiopathology ; Young Adult
8.Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study.
Hyung In YOON ; Min Jeong YOO ; Eun Jin PARK
The Journal of Advanced Prosthodontics 2017;9(6):432-438
PURPOSE: The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. MATERIALS AND METHODS: A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (ΔF), and DIAGNOdent peak readings were compared and statistically analyzed. RESULTS: Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were −0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was −0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 – 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 – 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. CONCLUSION: QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.
Bicuspid
;
Consensus
;
Diagnosis
;
Fluorescence*
;
In Vitro Techniques
;
Methods
;
Radiographic Image Enhancement
;
Radiography
;
Radiography, Bitewing
;
Reading
9.Multispectral X-ray imaging to distinguish among dental materials.
Ann Christin PETER ; Matthias SCHNAUBELT ; Michael GENTE
Imaging Science in Dentistry 2017;47(4):247-254
PURPOSE: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. MATERIALS AND METHODS: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. RESULTS: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. CONCLUSION: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.
Absorptiometry, Photon
;
Computer Simulation
;
Dental Materials*
;
Diagnosis
;
Methods
;
Mouth
;
Radiographic Image Enhancement
10.Accuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty.
Jong Ki SHIN ; Seung Min SON ; Tae Woo KIM ; Won Chul SHIN ; Jung Sub LEE ; Kuen Tak SUH
Hip & Pelvis 2016;28(4):201-207
PURPOSE: Preoperative on-screen templating is a method of using acetate templates on digital images. The aim of the present study was to evaluate the accuracy, intra- and interobserver reliabilities of preoperative on-screen templating using digital radiographs for total hip arthroplasty (THA). MATERIALS AND METHODS: Two hundred patients with hip disease who were treated with primary cementless THA were retrospectively evaluated. The accuracy of on-screen templating was assessed by comparing the predicted prosthesis sizes with the actual sizes used operatively. The inter- and intraobserver reliabilities of the templating results were also evaluated. RESULTS: The prosthesis prediction accuracy within ±one size was 96.6% for the cup size and 97.8% for the stem size. The inter- and intraobserver reliabilities for the implant size were substantial (kappa>0.70). The intra- and interobserver reliabilities for the leg length discrepancy and femoral offset difference using the intraclass correlation coefficient ranged from 0.89 to 0.97. CONCLUSION: Preoperative on-screen templating using digital radiographs showed substantial accuracy and reliability for implant prediction. It is an effective method for predicting the size of implant, correcting the leg length discrepancy and restoring the femoral offset.
Arthroplasty, Replacement, Hip*
;
Hip
;
Humans
;
Leg
;
Methods
;
Prostheses and Implants
;
Radiographic Image Enhancement
;
Retrospective Studies

Result Analysis