1.Association of Age, Sex and Education With Access to the Intravenous Thrombolysis for Acute Ischemic Stroke
Yoona KO ; Beom Joon KIM ; Youngran KIM ; Jong-Moo PARK ; Kyusik KANG ; Jae Guk KIM ; Jae-Kwan CHA ; Tai Hwan PARK ; Kyungbok LEE ; Jun LEE ; Keun-Sik HONG ; Byung-Chul LEE ; Kyung-Ho YU ; Dong-Eog KIM ; Joon-Tae KIM ; Jay Chol CHOI ; Jee Hyun KWON ; Wook-Joo KIM ; Kyu Sun YUM ; Sung-Il SOHN ; Hyungjong PARK ; Sang-Hwa LEE ; Kwang-Yeol PARK ; Chi Kyung KIM ; Sung Hyuk HEO ; Moon-Ku HAN ; Anjail Z. SHARRIEF ; Sunil A. SHETH ; Hee-Joon BAE ;
Journal of Korean Medical Science 2025;40(13):e49-
Background:
Barriers to treatment with intravenous thrombolysis (IVT) for patients with acute ischemic stroke (AIS) in South Korea remain incompletely characterized. We analyze a nationwide prospective cohort to determine patient-level features associated with delayed presentation and non-treatment of potential IVT-eligible patients.
Methods:
We identified consecutive patients with AIS from 01/2011 to 08/2023 from a multicenter and prospective acute stroke registry in Korea. Patients were defined as IVT candidates if they presented within 4.5 hours from the last known well, had no lab evidence of coagulopathy, and had National Institute of Health Stroke Scale (NIHSS) ≥ 4. Multivariable generalized linear mixed regression models were used to investigate the associations between their characteristics and the IVT candidates or the use of IVT among the candidates.
Results:
Among 84,103 AIS patients, 41.0% were female, with a mean age of 69 ± 13 years and presentation NIHSS of 4 [interquartile range, 1–8]. Out of these patients, 13,757 (16.4%) were eligible for IVT, of whom 8,179 (59.5%) received IVT. Female sex (adjusted risk ratio [RR], 0.90; 95% confidence interval [CI], 0.86–0.94) and lower years of education (adjusted RR, 0.90; 95% CI, 0.84–0.97 for 0–3 years, compared to ≥ 13 years) were associated with a decreased likelihood of presenting as eligible for IVT after AIS; meanwhile, young age (adjusted RR, 1.12; 95% CI, 1.01–1.24 for ≤ 44 years, compared to 75–84 years) was associated with an increased likelihood of being an IVT candidate. Among those who were eligible for IVT, only age was significantly associated with the use of IVT (adjusted RR, 1.09; 95% CI, 1.03–1.16 for age 65–74 and adjusted RR, 0.83; 95% CI, 0.76–0.90 for ≥ 85 years, respectively).
Conclusion
Most patients with AIS present outside IVT eligibility in South Korea, and only 60% of eligible patients were ultimately treated. We identified increased age, female sex and lower education as key features on which to focus interventions for improving IVT utilization.
2.Association of Age, Sex and Education With Access to the Intravenous Thrombolysis for Acute Ischemic Stroke
Yoona KO ; Beom Joon KIM ; Youngran KIM ; Jong-Moo PARK ; Kyusik KANG ; Jae Guk KIM ; Jae-Kwan CHA ; Tai Hwan PARK ; Kyungbok LEE ; Jun LEE ; Keun-Sik HONG ; Byung-Chul LEE ; Kyung-Ho YU ; Dong-Eog KIM ; Joon-Tae KIM ; Jay Chol CHOI ; Jee Hyun KWON ; Wook-Joo KIM ; Kyu Sun YUM ; Sung-Il SOHN ; Hyungjong PARK ; Sang-Hwa LEE ; Kwang-Yeol PARK ; Chi Kyung KIM ; Sung Hyuk HEO ; Moon-Ku HAN ; Anjail Z. SHARRIEF ; Sunil A. SHETH ; Hee-Joon BAE ;
Journal of Korean Medical Science 2025;40(13):e49-
Background:
Barriers to treatment with intravenous thrombolysis (IVT) for patients with acute ischemic stroke (AIS) in South Korea remain incompletely characterized. We analyze a nationwide prospective cohort to determine patient-level features associated with delayed presentation and non-treatment of potential IVT-eligible patients.
Methods:
We identified consecutive patients with AIS from 01/2011 to 08/2023 from a multicenter and prospective acute stroke registry in Korea. Patients were defined as IVT candidates if they presented within 4.5 hours from the last known well, had no lab evidence of coagulopathy, and had National Institute of Health Stroke Scale (NIHSS) ≥ 4. Multivariable generalized linear mixed regression models were used to investigate the associations between their characteristics and the IVT candidates or the use of IVT among the candidates.
Results:
Among 84,103 AIS patients, 41.0% were female, with a mean age of 69 ± 13 years and presentation NIHSS of 4 [interquartile range, 1–8]. Out of these patients, 13,757 (16.4%) were eligible for IVT, of whom 8,179 (59.5%) received IVT. Female sex (adjusted risk ratio [RR], 0.90; 95% confidence interval [CI], 0.86–0.94) and lower years of education (adjusted RR, 0.90; 95% CI, 0.84–0.97 for 0–3 years, compared to ≥ 13 years) were associated with a decreased likelihood of presenting as eligible for IVT after AIS; meanwhile, young age (adjusted RR, 1.12; 95% CI, 1.01–1.24 for ≤ 44 years, compared to 75–84 years) was associated with an increased likelihood of being an IVT candidate. Among those who were eligible for IVT, only age was significantly associated with the use of IVT (adjusted RR, 1.09; 95% CI, 1.03–1.16 for age 65–74 and adjusted RR, 0.83; 95% CI, 0.76–0.90 for ≥ 85 years, respectively).
Conclusion
Most patients with AIS present outside IVT eligibility in South Korea, and only 60% of eligible patients were ultimately treated. We identified increased age, female sex and lower education as key features on which to focus interventions for improving IVT utilization.
3.Association of Age, Sex and Education With Access to the Intravenous Thrombolysis for Acute Ischemic Stroke
Yoona KO ; Beom Joon KIM ; Youngran KIM ; Jong-Moo PARK ; Kyusik KANG ; Jae Guk KIM ; Jae-Kwan CHA ; Tai Hwan PARK ; Kyungbok LEE ; Jun LEE ; Keun-Sik HONG ; Byung-Chul LEE ; Kyung-Ho YU ; Dong-Eog KIM ; Joon-Tae KIM ; Jay Chol CHOI ; Jee Hyun KWON ; Wook-Joo KIM ; Kyu Sun YUM ; Sung-Il SOHN ; Hyungjong PARK ; Sang-Hwa LEE ; Kwang-Yeol PARK ; Chi Kyung KIM ; Sung Hyuk HEO ; Moon-Ku HAN ; Anjail Z. SHARRIEF ; Sunil A. SHETH ; Hee-Joon BAE ;
Journal of Korean Medical Science 2025;40(13):e49-
Background:
Barriers to treatment with intravenous thrombolysis (IVT) for patients with acute ischemic stroke (AIS) in South Korea remain incompletely characterized. We analyze a nationwide prospective cohort to determine patient-level features associated with delayed presentation and non-treatment of potential IVT-eligible patients.
Methods:
We identified consecutive patients with AIS from 01/2011 to 08/2023 from a multicenter and prospective acute stroke registry in Korea. Patients were defined as IVT candidates if they presented within 4.5 hours from the last known well, had no lab evidence of coagulopathy, and had National Institute of Health Stroke Scale (NIHSS) ≥ 4. Multivariable generalized linear mixed regression models were used to investigate the associations between their characteristics and the IVT candidates or the use of IVT among the candidates.
Results:
Among 84,103 AIS patients, 41.0% were female, with a mean age of 69 ± 13 years and presentation NIHSS of 4 [interquartile range, 1–8]. Out of these patients, 13,757 (16.4%) were eligible for IVT, of whom 8,179 (59.5%) received IVT. Female sex (adjusted risk ratio [RR], 0.90; 95% confidence interval [CI], 0.86–0.94) and lower years of education (adjusted RR, 0.90; 95% CI, 0.84–0.97 for 0–3 years, compared to ≥ 13 years) were associated with a decreased likelihood of presenting as eligible for IVT after AIS; meanwhile, young age (adjusted RR, 1.12; 95% CI, 1.01–1.24 for ≤ 44 years, compared to 75–84 years) was associated with an increased likelihood of being an IVT candidate. Among those who were eligible for IVT, only age was significantly associated with the use of IVT (adjusted RR, 1.09; 95% CI, 1.03–1.16 for age 65–74 and adjusted RR, 0.83; 95% CI, 0.76–0.90 for ≥ 85 years, respectively).
Conclusion
Most patients with AIS present outside IVT eligibility in South Korea, and only 60% of eligible patients were ultimately treated. We identified increased age, female sex and lower education as key features on which to focus interventions for improving IVT utilization.
4.Association of Age, Sex and Education With Access to the Intravenous Thrombolysis for Acute Ischemic Stroke
Yoona KO ; Beom Joon KIM ; Youngran KIM ; Jong-Moo PARK ; Kyusik KANG ; Jae Guk KIM ; Jae-Kwan CHA ; Tai Hwan PARK ; Kyungbok LEE ; Jun LEE ; Keun-Sik HONG ; Byung-Chul LEE ; Kyung-Ho YU ; Dong-Eog KIM ; Joon-Tae KIM ; Jay Chol CHOI ; Jee Hyun KWON ; Wook-Joo KIM ; Kyu Sun YUM ; Sung-Il SOHN ; Hyungjong PARK ; Sang-Hwa LEE ; Kwang-Yeol PARK ; Chi Kyung KIM ; Sung Hyuk HEO ; Moon-Ku HAN ; Anjail Z. SHARRIEF ; Sunil A. SHETH ; Hee-Joon BAE ;
Journal of Korean Medical Science 2025;40(13):e49-
Background:
Barriers to treatment with intravenous thrombolysis (IVT) for patients with acute ischemic stroke (AIS) in South Korea remain incompletely characterized. We analyze a nationwide prospective cohort to determine patient-level features associated with delayed presentation and non-treatment of potential IVT-eligible patients.
Methods:
We identified consecutive patients with AIS from 01/2011 to 08/2023 from a multicenter and prospective acute stroke registry in Korea. Patients were defined as IVT candidates if they presented within 4.5 hours from the last known well, had no lab evidence of coagulopathy, and had National Institute of Health Stroke Scale (NIHSS) ≥ 4. Multivariable generalized linear mixed regression models were used to investigate the associations between their characteristics and the IVT candidates or the use of IVT among the candidates.
Results:
Among 84,103 AIS patients, 41.0% were female, with a mean age of 69 ± 13 years and presentation NIHSS of 4 [interquartile range, 1–8]. Out of these patients, 13,757 (16.4%) were eligible for IVT, of whom 8,179 (59.5%) received IVT. Female sex (adjusted risk ratio [RR], 0.90; 95% confidence interval [CI], 0.86–0.94) and lower years of education (adjusted RR, 0.90; 95% CI, 0.84–0.97 for 0–3 years, compared to ≥ 13 years) were associated with a decreased likelihood of presenting as eligible for IVT after AIS; meanwhile, young age (adjusted RR, 1.12; 95% CI, 1.01–1.24 for ≤ 44 years, compared to 75–84 years) was associated with an increased likelihood of being an IVT candidate. Among those who were eligible for IVT, only age was significantly associated with the use of IVT (adjusted RR, 1.09; 95% CI, 1.03–1.16 for age 65–74 and adjusted RR, 0.83; 95% CI, 0.76–0.90 for ≥ 85 years, respectively).
Conclusion
Most patients with AIS present outside IVT eligibility in South Korea, and only 60% of eligible patients were ultimately treated. We identified increased age, female sex and lower education as key features on which to focus interventions for improving IVT utilization.
5.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
6.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
7.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
8.Efficacy and Safety of Metformin and Atorvastatin Combination Therapy vs. Monotherapy with Either Drug in Type 2 Diabetes Mellitus and Dyslipidemia Patients (ATOMIC): Double-Blinded Randomized Controlled Trial
Jie-Eun LEE ; Seung Hee YU ; Sung Rae KIM ; Kyu Jeung AHN ; Kee-Ho SONG ; In-Kyu LEE ; Ho-Sang SHON ; In Joo KIM ; Soo LIM ; Doo-Man KIM ; Choon Hee CHUNG ; Won-Young LEE ; Soon Hee LEE ; Dong Joon KIM ; Sung-Rae CHO ; Chang Hee JUNG ; Hyun Jeong JEON ; Seung-Hwan LEE ; Keun-Young PARK ; Sang Youl RHEE ; Sin Gon KIM ; Seok O PARK ; Dae Jung KIM ; Byung Joon KIM ; Sang Ah LEE ; Yong-Hyun KIM ; Kyung-Soo KIM ; Ji A SEO ; Il Seong NAM-GOONG ; Chang Won LEE ; Duk Kyu KIM ; Sang Wook KIM ; Chung Gu CHO ; Jung Han KIM ; Yeo-Joo KIM ; Jae-Myung YOO ; Kyung Wan MIN ; Moon-Kyu LEE
Diabetes & Metabolism Journal 2024;48(4):730-739
Background:
It is well known that a large number of patients with diabetes also have dyslipidemia, which significantly increases the risk of cardiovascular disease (CVD). This study aimed to evaluate the efficacy and safety of combination drugs consisting of metformin and atorvastatin, widely used as therapeutic agents for diabetes and dyslipidemia.
Methods:
This randomized, double-blind, placebo-controlled, parallel-group and phase III multicenter study included adults with glycosylated hemoglobin (HbA1c) levels >7.0% and <10.0%, low-density lipoprotein cholesterol (LDL-C) >100 and <250 mg/dL. One hundred eighty-five eligible subjects were randomized to the combination group (metformin+atorvastatin), metformin group (metformin+atorvastatin placebo), and atorvastatin group (atorvastatin+metformin placebo). The primary efficacy endpoints were the percent changes in HbA1c and LDL-C levels from baseline at the end of the treatment.
Results:
After 16 weeks of treatment compared to baseline, HbA1c showed a significant difference of 0.94% compared to the atorvastatin group in the combination group (0.35% vs. −0.58%, respectively; P<0.0001), whereas the proportion of patients with increased HbA1c was also 62% and 15%, respectively, showing a significant difference (P<0.001). The combination group also showed a significant decrease in LDL-C levels compared to the metformin group (−55.20% vs. −7.69%, P<0.001) without previously unknown adverse drug events.
Conclusion
The addition of atorvastatin to metformin improved HbA1c and LDL-C levels to a significant extent compared to metformin or atorvastatin alone in diabetes and dyslipidemia patients. This study also suggested metformin’s preventive effect on the glucose-elevating potential of atorvastatin in patients with type 2 diabetes mellitus and dyslipidemia, insufficiently controlled with exercise and diet. Metformin and atorvastatin combination might be an effective treatment in reducing the CVD risk in patients with both diabetes and dyslipidemia because of its lowering effect on LDL-C and glucose.
9.Study Design and Protocol for a Randomized Controlled Trial to Assess Long-Term Efficacy and Safety of a Triple Combination of Ezetimibe, Fenofibrate, and Moderate-Intensity Statin in Patients with Type 2 Diabetes and Modifiable Cardiovascular Risk Factors (ENSEMBLE)
Nam Hoon KIM ; Juneyoung LEE ; Suk CHON ; Jae Myung YU ; In-Kyung JEONG ; Soo LIM ; Won Jun KIM ; Keeho SONG ; Ho Chan CHO ; Hea Min YU ; Kyoung-Ah KIM ; Sang Soo KIM ; Soon Hee LEE ; Chong Hwa KIM ; Soo Heon KWAK ; Yong‐ho LEE ; Choon Hee CHUNG ; Sihoon LEE ; Heung Yong JIN ; Jae Hyuk LEE ; Gwanpyo KOH ; Sang-Yong KIM ; Jaetaek KIM ; Ju Hee LEE ; Tae Nyun KIM ; Hyun Jeong JEON ; Ji Hyun LEE ; Jae-Han JEON ; Hye Jin YOO ; Hee Kyung KIM ; Hyeong-Kyu PARK ; Il Seong NAM-GOONG ; Seongbin HONG ; Chul Woo AHN ; Ji Hee YU ; Jong Heon PARK ; Keun-Gyu PARK ; Chan Ho PARK ; Kyong Hye JOUNG ; Ohk-Hyun RYU ; Keun Yong PARK ; Eun-Gyoung HONG ; Bong-Soo CHA ; Kyu Chang WON ; Yoon-Sok CHUNG ; Sin Gon KIM
Endocrinology and Metabolism 2024;39(5):722-731
Background:
Atherogenic dyslipidemia, which is frequently associated with type 2 diabetes (T2D) and insulin resistance, contributes to the development of vascular complications. Statin therapy is the primary approach to dyslipidemia management in T2D, however, the role of non-statin therapy remains unclear. Ezetimibe reduces cholesterol burden by inhibiting intestinal cholesterol absorption. Fibrates lower triglyceride levels and increase high-density lipoprotein cholesterol (HDL-C) levels via peroxisome proliferator- activated receptor alpha agonism. Therefore, when combined, these drugs effectively lower non-HDL-C levels. Despite this, few clinical trials have specifically targeted non-HDL-C, and the efficacy of triple combination therapies, including statins, ezetimibe, and fibrates, has yet to be determined.
Methods:
This is a multicenter, prospective, randomized, open-label, active-comparator controlled trial involving 3,958 eligible participants with T2D, cardiovascular risk factors, and elevated non-HDL-C (≥100 mg/dL). Participants, already on moderate-intensity statins, will be randomly assigned to either Ezefeno (ezetimibe/fenofibrate) addition or statin dose-escalation. The primary end point is the development of a composite of major adverse cardiovascular and diabetic microvascular events over 48 months.
Conclusion
This trial aims to assess whether combining statins, ezetimibe, and fenofibrate is as effective as, or possibly superior to, statin monotherapy intensification in lowering cardiovascular and microvascular disease risk for patients with T2D. This could propose a novel therapeutic approach for managing dyslipidemia in T2D.
10.First-in-Human Evaluation of a Polymer-Free Everolimus-Eluting Stent Using a Titanium Dioxide Film
Doo Sun SIM ; Kyung Hoon CHO ; Dae Young HYUN ; Dae Sung PARK ; Jun-Kyu PARK ; Dae-Heung BYEON ; Won-Il JO ; Sang-Wook KIM ; Joon Ho AHN ; Seung Hun LEE ; Min Chul KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG
Journal of Korean Medical Science 2024;39(33):e234-
Background:
In patients with coronary artery disease treated with permanent polymercoated drug-eluting stents (DES), the persistent presence of a less biocompatible polymer might delay arterial healing. Thin strut polymer-free DES have the potential to improve clinical outcomes and reduce the duration of dual antiplatelet therapy (DAPT). The purpose of this first-in-human study was to assess the safety and effectiveness of a novel polymer-free DES in patients with de novo coronary lesions. The TIGERevolutioN® stent (CG Bio Co., Ltd., Seoul, Korea) consists of a cobalt chromium platform with a strut thickness of 70 μm and a surface treated with titanium dioxide onto which everolimus-eluting stent (EES) is applied abluminally (6 µg/mm of stent length) without utilization of a polymer.
Methods:
A total of 20 patients were enrolled, with de novo coronary lesions (stable or unstable angina) and > 50% diameter stenosis in a vessel 2.25 to 4.00 mm in diameter and ≤ 40 mm in length for angiographic, optical coherence tomography (OCT), and clinical assessment at 8 months. All patients received DAPT after stent implantation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at 8 months.
Results:
Twenty patients with 20 lesions were treated with TIGERevolutioN® . At 8 months, in-stent LLL was 0.7 ± 0.4 mm. On OCT, percent area stenosis was 29.2 ± 9.4% and stent strut coverage was complete in all lesions. No adverse cardiovascular event occurred at 8 months.
Conclusion
The new polymer-free EES was safe and effective with low LLL and excellent strut coverage at 8 months of follow-up.

Result Analysis
Print
Save
E-mail