1.Association of weight and dietary habits with high blood mercury levels in Korean adolescents: data from the KoNEHS cycle 4, 2018-2020
Ji Hoon KIM ; Minju JUNG ; Jaewon MUN ; Dong-Jae SEO ; Jong-Han LEEM ; Shin-Goo PARK ; Dong-Wook LEE ; Hyung Doo KIM ; Hwan-Cheol KIM
Annals of Occupational and Environmental Medicine 2025;37(1):e5-
Background:
Humans are exposed to mercury primarily in its highly toxic form, methyl mercury, which is known to have adverse effects on various organs and systems. The negative impact of mercury exposure on the growth, development, and mental health of children, from infancy to adolescence, is well-documented. However, there are no internationally standardized safe limits for mercury exposure. This study investigated the impact of dietary habits and higher body mass index (BMI) on blood mercury levels in adolescents.
Methods:
This study analyzed the data from the 4th Korean National Environmental Health Survey (KoNEHS) 2018–2020. The focus was on 825 middle and high school students aged 13–18 years, whose blood mercury levels were measured. A survey on dietary and lifestyle habits was also conducted. Blood mercury levels were categorized by geometric median values, and associations with overweight status and seafood consumption were examined using a generalized linear model.
Results:
The geometric mean blood mercury level for the entire sample was 1.37 μg/L, with levels of 1.31 μg/L in normal-weight individuals and 1.43 μg/L in overweight individuals, showing a statistically significant difference between the two groups. After adjusting for other variables, blood mercury levels were significantly associated with overweight status (estimate: 0.084; p = 0.018; 95% confidence interval [CI]: 0.015–0.153), consumption of large fish and tuna more than once a week (estimate: 0.18; p = 0.001; 95% CI: 0.077–0.284), and consumption of fish once a week or more (estimate: 0.147; p = 0.004; 95% CI: 0.043–0.250).
Conclusions
In adolescents, a higher BMI and an increased consumption of large fish, tuna, and fish were associated with higher blood mercury levels. Notably, a stronger association was found between large fish consumption and blood mercury levels in the overweight group. These findings suggest the need to moderate seafood consumption and establish more proactive mercury exposure standards for adolescents.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Association of weight and dietary habits with high blood mercury levels in Korean adolescents: data from the KoNEHS cycle 4, 2018-2020
Ji Hoon KIM ; Minju JUNG ; Jaewon MUN ; Dong-Jae SEO ; Jong-Han LEEM ; Shin-Goo PARK ; Dong-Wook LEE ; Hyung Doo KIM ; Hwan-Cheol KIM
Annals of Occupational and Environmental Medicine 2025;37(1):e5-
Background:
Humans are exposed to mercury primarily in its highly toxic form, methyl mercury, which is known to have adverse effects on various organs and systems. The negative impact of mercury exposure on the growth, development, and mental health of children, from infancy to adolescence, is well-documented. However, there are no internationally standardized safe limits for mercury exposure. This study investigated the impact of dietary habits and higher body mass index (BMI) on blood mercury levels in adolescents.
Methods:
This study analyzed the data from the 4th Korean National Environmental Health Survey (KoNEHS) 2018–2020. The focus was on 825 middle and high school students aged 13–18 years, whose blood mercury levels were measured. A survey on dietary and lifestyle habits was also conducted. Blood mercury levels were categorized by geometric median values, and associations with overweight status and seafood consumption were examined using a generalized linear model.
Results:
The geometric mean blood mercury level for the entire sample was 1.37 μg/L, with levels of 1.31 μg/L in normal-weight individuals and 1.43 μg/L in overweight individuals, showing a statistically significant difference between the two groups. After adjusting for other variables, blood mercury levels were significantly associated with overweight status (estimate: 0.084; p = 0.018; 95% confidence interval [CI]: 0.015–0.153), consumption of large fish and tuna more than once a week (estimate: 0.18; p = 0.001; 95% CI: 0.077–0.284), and consumption of fish once a week or more (estimate: 0.147; p = 0.004; 95% CI: 0.043–0.250).
Conclusions
In adolescents, a higher BMI and an increased consumption of large fish, tuna, and fish were associated with higher blood mercury levels. Notably, a stronger association was found between large fish consumption and blood mercury levels in the overweight group. These findings suggest the need to moderate seafood consumption and establish more proactive mercury exposure standards for adolescents.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Association of weight and dietary habits with high blood mercury levels in Korean adolescents: data from the KoNEHS cycle 4, 2018-2020
Ji Hoon KIM ; Minju JUNG ; Jaewon MUN ; Dong-Jae SEO ; Jong-Han LEEM ; Shin-Goo PARK ; Dong-Wook LEE ; Hyung Doo KIM ; Hwan-Cheol KIM
Annals of Occupational and Environmental Medicine 2025;37(1):e5-
Background:
Humans are exposed to mercury primarily in its highly toxic form, methyl mercury, which is known to have adverse effects on various organs and systems. The negative impact of mercury exposure on the growth, development, and mental health of children, from infancy to adolescence, is well-documented. However, there are no internationally standardized safe limits for mercury exposure. This study investigated the impact of dietary habits and higher body mass index (BMI) on blood mercury levels in adolescents.
Methods:
This study analyzed the data from the 4th Korean National Environmental Health Survey (KoNEHS) 2018–2020. The focus was on 825 middle and high school students aged 13–18 years, whose blood mercury levels were measured. A survey on dietary and lifestyle habits was also conducted. Blood mercury levels were categorized by geometric median values, and associations with overweight status and seafood consumption were examined using a generalized linear model.
Results:
The geometric mean blood mercury level for the entire sample was 1.37 μg/L, with levels of 1.31 μg/L in normal-weight individuals and 1.43 μg/L in overweight individuals, showing a statistically significant difference between the two groups. After adjusting for other variables, blood mercury levels were significantly associated with overweight status (estimate: 0.084; p = 0.018; 95% confidence interval [CI]: 0.015–0.153), consumption of large fish and tuna more than once a week (estimate: 0.18; p = 0.001; 95% CI: 0.077–0.284), and consumption of fish once a week or more (estimate: 0.147; p = 0.004; 95% CI: 0.043–0.250).
Conclusions
In adolescents, a higher BMI and an increased consumption of large fish, tuna, and fish were associated with higher blood mercury levels. Notably, a stronger association was found between large fish consumption and blood mercury levels in the overweight group. These findings suggest the need to moderate seafood consumption and establish more proactive mercury exposure standards for adolescents.
7.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
8.Evaluation of the Commutability of ThyroidStimulating Hormone Measurements for Proficiency Testing
Jong Hyeon LEE ; Sang-Mi KIM ; Jong Do SEO ; Yeo-Min YUN ; Hyung-Doo PARK
Journal of Laboratory Medicine and Quality Assurance 2024;46(4):200-207
Background:
Commutability refers to the consistency of results from different measurement procedures in regards to a reference material (RM) and representative samples. In this study, we evaluated the commutability of laboratory-prepared pooled sera and commercial quality control materials in the thyroid-stimulating hormone (TSH) proficiency testing program of the Korean Association of External Quality Assessment Service.
Methods:
Serum TSH from 30 patients was measured in triplicate. Two levels of lab-prepared pooled sera and three levels of commercial materials (Bio-Rad Liquichek Immunoassay Plus) were tested in triplicate at five positions per immunoassay platform (Beckman Coulter UniCel DxI 800, Abbott Alinity i, Roche Cobas e801, Siemens Atellica IM 1600). Commutability was assessed by comparing method differences in patient samples to RMs using the ‘International Federation of Clinical Chemistry and Laboratory Medicine’ protocol with a desirable bias of 10% based on biological variation.
Results:
The median TSH level for the 30 patient samples was 2.51–3.07 μIU/mL, with a coefficient of variation ranging from 1.51% to 4.32%.The median TSH levels of the in-house prepared materials were 0.912– 1.01 μIU/mL for RM2 and 9.10–10.9 μIU/mL for RM4. The median TSH levels of the commercial materials were 0.391–0.464 μIU/mL for RM1, 4.39–5.24 μIU/mL for RM3, and 28.2–35.5 μIU/mL for RM5. The in-house prepared materials (RM2, RM4) demonstrated commutability across all six method combinations. Among the commercial materials, RM1 and RM3 showed commutability in four method combinations, while RM5 showed commutability in three method combinations.
Conclusions
The evaluation results for the TSH proficiency testing materials showed that the in-house prepared materials had higher commutability than the commercial materials.
9.Establishment of Preanalytical Quality Indicators and Current Status of Preanalytical Phase Laboratory Performance Monitoring in the Clinical Laboratories in Korea
Sang-Mi KIM ; Kyunghoon LEE ; Sollip KIM ; Yong-Wha LEE ; Sail CHUN ; Hyung-Doo PARK
Journal of Laboratory Medicine and Quality Assurance 2024;46(3):145-155
Background:
The preanalytical phase is more vulnerable to errors. This study aimed to establish preanalytical quality indicators (QIs) suitable for Korean clinical laboratories and investigate the current status of preanalytical phase performance monitoring in Korea using these QIs.
Methods:
We reviewed previous studies investigating preanalytical QIs including the International Federation of Clinical Chemistry (IFCC) model of QIs, to establish a set of QIs for Korean clinical laboratories. An e-mail survey consisting of this QI set was sent to 90 clinical laboratories. The collected data were analyzed, and performance measures were evaluated according to the quality specifications defined by the IFCC and the sigmascale method.
Results:
A model consisting of 23 preanalytical phase QIs was established.Approximately 47% (42/90) of clinical laboratories responded to the survey.The average result submission rate for each QI was 56% (standard deviation, 26%). The QIs with the highest and lowest result submission rates were “rejected samples due to hemolysis” (95%) and “recollected sample due to errors caused outside the laboratory” (17%). The QIs with the highest and lowest error rates were “hemolyzed sample detected by hemolytic index” (median, 0.546%; sigma performance level, “good”) and “samples not received” (median, 0.001%; sigma performance level, “very good”), respectively.
Conclusions
This survey findings on preanalytical phase QIs could serve as a foundation for developing an external quality assessment program for clinical laboratories in Korea.
10.Evaluation of the Commutability of ThyroidStimulating Hormone Measurements for Proficiency Testing
Jong Hyeon LEE ; Sang-Mi KIM ; Jong Do SEO ; Yeo-Min YUN ; Hyung-Doo PARK
Journal of Laboratory Medicine and Quality Assurance 2024;46(4):200-207
Background:
Commutability refers to the consistency of results from different measurement procedures in regards to a reference material (RM) and representative samples. In this study, we evaluated the commutability of laboratory-prepared pooled sera and commercial quality control materials in the thyroid-stimulating hormone (TSH) proficiency testing program of the Korean Association of External Quality Assessment Service.
Methods:
Serum TSH from 30 patients was measured in triplicate. Two levels of lab-prepared pooled sera and three levels of commercial materials (Bio-Rad Liquichek Immunoassay Plus) were tested in triplicate at five positions per immunoassay platform (Beckman Coulter UniCel DxI 800, Abbott Alinity i, Roche Cobas e801, Siemens Atellica IM 1600). Commutability was assessed by comparing method differences in patient samples to RMs using the ‘International Federation of Clinical Chemistry and Laboratory Medicine’ protocol with a desirable bias of 10% based on biological variation.
Results:
The median TSH level for the 30 patient samples was 2.51–3.07 μIU/mL, with a coefficient of variation ranging from 1.51% to 4.32%.The median TSH levels of the in-house prepared materials were 0.912– 1.01 μIU/mL for RM2 and 9.10–10.9 μIU/mL for RM4. The median TSH levels of the commercial materials were 0.391–0.464 μIU/mL for RM1, 4.39–5.24 μIU/mL for RM3, and 28.2–35.5 μIU/mL for RM5. The in-house prepared materials (RM2, RM4) demonstrated commutability across all six method combinations. Among the commercial materials, RM1 and RM3 showed commutability in four method combinations, while RM5 showed commutability in three method combinations.
Conclusions
The evaluation results for the TSH proficiency testing materials showed that the in-house prepared materials had higher commutability than the commercial materials.