1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
4.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
5.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Low level laser therapy alleviates mechanical allodynia in a postoperative and neuropathic pain model and alters the levels of inflammatory factors in rats
Xuehao HAN ; Kyeong-cheol JANG ; Woong Mo KIM ; Hyung Gon LEE
The Korean Journal of Pain 2024;37(4):310-319
Background:
This study aimed to investigate the analgesic and preventive effect of low-level laser therapy (LLLT) on the incisional pain model and spinal nerve ligation (SNL) model in rats and identify the possible mechanisms of action.
Methods:
Male Sprague-Dawley rats were used, divided into different treatment groups. The single application group received LLLT before or after skin incision or SNL. The consecutive application group received LLLT for six consecutive days post-incision, three days pre-incision, or three consecutive days pre-SNL. The control group underwent skin incision or SNL without LLLT. The von Frey test was used to quantify the pain associated with mechanical allodynia. Pro-inflammatory cytokine level and alterations in nerve growth factor (NGF) expression were measured by using ELISA and immunohistochemistry, respectively in the skin, muscle of the paw, and spinal cord dorsal horn (SCDH).
Results:
In the incisional pain model, LLLT showed significant analgesic and preventive effect. LLLT ameliorated SNL-induced mechanical allodynia but LLLT had no preventive effect. LLLT decreased interleukin-1β (IL-1β) expression levels in the skin, muscle, and SCDH and reduced the optical density of skin and spinal cord NGF in the incisional pain model.
Conclusions
LLLT alleviated incisional pain and neuropathic pain caused by SNL in rats, and reduced the levels of IL-1β and NGF in the peripheral tissue and SCDH in the incisional pain model. LLLT might be effective in patients with post-operative pain and peripheral neuropathic pain.
10.Low level laser therapy alleviates mechanical allodynia in a postoperative and neuropathic pain model and alters the levels of inflammatory factors in rats
Xuehao HAN ; Kyeong-cheol JANG ; Woong Mo KIM ; Hyung Gon LEE
The Korean Journal of Pain 2024;37(4):310-319
Background:
This study aimed to investigate the analgesic and preventive effect of low-level laser therapy (LLLT) on the incisional pain model and spinal nerve ligation (SNL) model in rats and identify the possible mechanisms of action.
Methods:
Male Sprague-Dawley rats were used, divided into different treatment groups. The single application group received LLLT before or after skin incision or SNL. The consecutive application group received LLLT for six consecutive days post-incision, three days pre-incision, or three consecutive days pre-SNL. The control group underwent skin incision or SNL without LLLT. The von Frey test was used to quantify the pain associated with mechanical allodynia. Pro-inflammatory cytokine level and alterations in nerve growth factor (NGF) expression were measured by using ELISA and immunohistochemistry, respectively in the skin, muscle of the paw, and spinal cord dorsal horn (SCDH).
Results:
In the incisional pain model, LLLT showed significant analgesic and preventive effect. LLLT ameliorated SNL-induced mechanical allodynia but LLLT had no preventive effect. LLLT decreased interleukin-1β (IL-1β) expression levels in the skin, muscle, and SCDH and reduced the optical density of skin and spinal cord NGF in the incisional pain model.
Conclusions
LLLT alleviated incisional pain and neuropathic pain caused by SNL in rats, and reduced the levels of IL-1β and NGF in the peripheral tissue and SCDH in the incisional pain model. LLLT might be effective in patients with post-operative pain and peripheral neuropathic pain.

Result Analysis
Print
Save
E-mail