1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
4.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
5.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.The Profile of Early Sedation Depth and Clinical Outcomes of Mechanically Ventilated Patients in Korea
Dong-gon HYUN ; Jee Hwan AHN ; Ha-Yeong GIL ; Chung Mo NAM ; Choa YUN ; Jae-Myeong LEE ; Jae Hun KIM ; Dong-Hyun LEE ; Ki Hoon KIM ; Dong Jung KIM ; Sang-Min LEE ; Ho-Geol RYU ; Suk-Kyung HONG ; Jae-Bum KIM ; Eun Young CHOI ; JongHyun BAEK ; Jeoungmin KIM ; Eun Jin KIM ; Tae Yun PARK ; Je Hyeong KIM ; Sunghoon PARK ; Chi-Min PARK ; Won Jai JUNG ; Nak-Jun CHOI ; Hang-Jea JANG ; Su Hwan LEE ; Young Seok LEE ; Gee Young SUH ; Woo-Sung CHOI ; Keu Sung LEE ; Hyung Won KIM ; Young-Gi MIN ; Seok Jeong LEE ; Chae-Man LIM
Journal of Korean Medical Science 2023;38(19):e141-
Background:
Current international guidelines recommend against deep sedation as it is associated with worse outcomes in the intensive care unit (ICU). However, in Korea the prevalence of deep sedation and its impact on patients in the ICU are not well known.
Methods:
From April 2020 to July 2021, a multicenter, prospective, longitudinal, noninterventional cohort study was performed in 20 Korean ICUs. Sedation depth extent was divided into light and deep using a mean Richmond Agitation–Sedation Scale value within the first 48 hours. Propensity score matching was used to balance covariables; the outcomes were compared between the two groups.
Results:
Overall, 631 patients (418 [66.2%] and 213 [33.8%] in the deep and light sedation groups, respectively) were included. Mortality rates were 14.1% and 8.4% in the deep and light sedation groups (P = 0.039), respectively. Kaplan-Meier estimates showed that time to extubation (P < 0.001), ICU length of stay (P = 0.005), and death P = 0.041) differed between the groups. After adjusting for confounders, early deep sedation was only associated with delayed time to extubation (hazard ratio [HR], 0.66; 95% confidence inter val [CI], 0.55– 0.80; P < 0.001). In the matched cohort, deep sedation remained significantly associated with delayed time to extubation (HR, 0.68; 95% 0.56–0.83; P < 0.001) but was not associated with ICU length of stay (HR, 0.94; 95% CI, 0.79–1.13; P = 0.500) and in-hospital mortality (HR, 1.19; 95% CI, 0.65–2.17; P = 0.582).
Conclusion
In many Korean ICUs, early deep sedation was highly prevalent in mechanically ventilated patients and was associated with delayed extubation, but not prolonged ICU stay or in-hospital death.

Result Analysis
Print
Save
E-mail