1.Improving breast ultrasonography education: the impact of AI-based decision support on the performance of non-specialist medical professionals
Sangwon LEE ; Hye Sun LEE ; Eunju LEE ; Won Hwa KIM ; Jaeil KIM ; Jung Hyun YOON
Ultrasonography 2025;44(2):124-133
Purpose:
This study evaluated the educational impact of an artificial intelligence (AI)–based decision support system for breast ultrasonography (US) on medical professionals not specialized in breast imaging.
Methods:
In this multi-case, multi-reader study, educational materials, including American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) descriptors, were provided alongside corresponding AI results during training. The AI system presented results in the form of AIheatmaps, AI scores, and AI-provided BI-RADS assessment categories. Forty-two readers evaluated the test set in three sessions: the first session (S1) occurred before the educational intervention, the second session (S2) followed education without AI assistance, and the third session (S3) took place after education with AI assistance. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and overall performance, were compared between the sessions.
Results:
The mean sensitivity increased from 66.5% (95% confidence interval [CI], 59.2% to 73.7%) to 88.7% (95% CI, 84.1% to 93.3%), with a statistically significant difference (P<0.001), and the AUC non-significantly increased from 0.664 (95% CI, 0.606 to 0.723) to 0.684 (95% CI, 0.620 to 0.748) (P=0.300). Both measures were higher in S2 than in S1. The AI-achieved AUC was comparable to that of the expert reader (0.747 [95% CI, 0.640 to 0.855] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.217). Additionally, with AI assistance, the mean AUC for inexperienced readers was not significantly different from that of the expert reader (0.745 [95% CI, 0.660 to 0.830] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.120).
Conclusion
The mean AUC and sensitivity improved after incorporating AI into breast US education and interpretation. AI systems with high-level performance for breast US can potentially be used as educational tools in the interpretation of breast US images.
2.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
3.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
4.Improving breast ultrasonography education: the impact of AI-based decision support on the performance of non-specialist medical professionals
Sangwon LEE ; Hye Sun LEE ; Eunju LEE ; Won Hwa KIM ; Jaeil KIM ; Jung Hyun YOON
Ultrasonography 2025;44(2):124-133
Purpose:
This study evaluated the educational impact of an artificial intelligence (AI)–based decision support system for breast ultrasonography (US) on medical professionals not specialized in breast imaging.
Methods:
In this multi-case, multi-reader study, educational materials, including American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) descriptors, were provided alongside corresponding AI results during training. The AI system presented results in the form of AIheatmaps, AI scores, and AI-provided BI-RADS assessment categories. Forty-two readers evaluated the test set in three sessions: the first session (S1) occurred before the educational intervention, the second session (S2) followed education without AI assistance, and the third session (S3) took place after education with AI assistance. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and overall performance, were compared between the sessions.
Results:
The mean sensitivity increased from 66.5% (95% confidence interval [CI], 59.2% to 73.7%) to 88.7% (95% CI, 84.1% to 93.3%), with a statistically significant difference (P<0.001), and the AUC non-significantly increased from 0.664 (95% CI, 0.606 to 0.723) to 0.684 (95% CI, 0.620 to 0.748) (P=0.300). Both measures were higher in S2 than in S1. The AI-achieved AUC was comparable to that of the expert reader (0.747 [95% CI, 0.640 to 0.855] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.217). Additionally, with AI assistance, the mean AUC for inexperienced readers was not significantly different from that of the expert reader (0.745 [95% CI, 0.660 to 0.830] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.120).
Conclusion
The mean AUC and sensitivity improved after incorporating AI into breast US education and interpretation. AI systems with high-level performance for breast US can potentially be used as educational tools in the interpretation of breast US images.
5.Clinical Practice Guidelines for Dementia: Recommendations for Cholinesterase Inhibitors and Memantine
Yeshin KIM ; Dong Woo KANG ; Geon Ha KIM ; Ko Woon KIM ; Hee-Jin KIM ; Seunghee NA ; Kee Hyung PARK ; Young Ho PARK ; Gihwan BYEON ; Jeewon SUH ; Joon Hyun SHIN ; YongSoo SHIM ; YoungSoon YANG ; Yoo Hyun UM ; Seong-il OH ; Sheng-Min WANG ; Bora YOON ; Sun Min LEE ; Juyoun LEE ; Jin San LEE ; Jae-Sung LIM ; Young Hee JUNG ; Juhee CHIN ; Hyemin JANG ; Miyoung CHOI ; Yun Jeong HONG ; Hak Young RHEE ; Jae-Won JANG ;
Dementia and Neurocognitive Disorders 2025;24(1):1-23
Background:
and Purpose: This clinical practice guideline provides evidence-based recommendations for treatment of dementia, focusing on cholinesterase inhibitors and N-methyl-D-aspartate (NMDA) receptor antagonists for Alzheimer’s disease (AD) and other types of dementia.
Methods:
Using the Population, Intervention, Comparison, Outcomes (PICO) framework, we developed key clinical questions and conducted systematic literature reviews. A multidisciplinary panel of experts, organized by the Korean Dementia Association, evaluated randomized controlled trials and observational studies. Recommendations were graded for evidence quality and strength using Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology.
Results:
Three main recommendations are presented: (1) For AD, cholinesterase inhibitors (donepezil, rivastigmine, galantamine) are strongly recommended for improving cognition and daily function based on moderate evidence; (2) Cholinesterase inhibitors are conditionally recommended for vascular dementia and Parkinson’s disease dementia, with a strong recommendation for Lewy body dementia; (3) For moderate to severe AD, NMDA receptor antagonist (memantine) is strongly recommended, demonstrating significant cognitive and functional improvements. Both drug classes showed favorable safety profiles with manageable side effects.
Conclusions
This guideline offers standardized, evidence-based pharmacologic recommendations for dementia management, with specific guidance on cholinesterase inhibitors and NMDA receptor antagonists. It aims to support clinical decision-making and improve patient outcomes in dementia care. Further updates will address emerging treatments, including amyloid-targeting therapies, to reflect advances in dementia management.
6.Carnitine Metabolite as a Potential Circulating Biomarker for Sarcopenia in Men
Je Hyun SEO ; Jung-Min KOH ; Han Jin CHO ; Hanjun KIM ; Young‑Sun LEE ; Su Jung KIM ; Pil Whan YOON ; Won KIM ; Sung Jin BAE ; Hong-Kyu KIM ; Hyun Ju YOO ; Seung Hun LEE
Endocrinology and Metabolism 2025;40(1):93-102
Background:
Sarcopenia, a multifactorial disorder involving metabolic disturbance, suggests potential for metabolite biomarkers. Carnitine (CN), essential for skeletal muscle energy metabolism, may be a candidate biomarker. We investigated whether CN metabolites are biomarkers for sarcopenia.
Methods:
Associations between the CN metabolites identified from an animal model of sarcopenia and muscle cells and sarcopenia status were evaluated in men from an age-matched discovery (72 cases, 72 controls) and a validation (21 cases, 47 controls) cohort.
Results:
An association between CN metabolites and sarcopenia showed in mouse and cell studies. In the discovery cohort, plasma C5-CN levels were lower in sarcopenic men (P=0.005). C5-CN levels in men tended to be associated with handgrip strength (HGS) (P=0.098) and were significantly associated with skeletal muscle mass (P=0.003). Each standard deviation increase in C5-CN levels reduced the odds of low muscle mass (odd ratio, 0.61; 95% confidence interval [CI], 0.42 to 0.89). The area under the receiver operating characteristic curve (AUROC) of CN score using a regression equation of C5-CN levels, for sarcopenia was 0.635 (95% CI, 0.544 to 0.726). In the discovery cohort, addition of CN score to HGS significantly improved AUROC from 0.646 (95% CI, 0.575 to 0.717; HGS only) to 0.727 (95% CI, 0.643 to 0.810; P=0.006; HGS+CN score). The improvement was confirmed in the validation cohort (AUROC=0.563; 95% CI, 0.470 to 0.656 for HGS; and AUROC=0.712; 95% CI, 0.569 to 0.855 for HGS+CN score; P=0.027).
Conclusion
C5-CN, indicative of low muscle mass, is a potential circulating biomarker for sarcopenia in men. Further studies are required to confirm these results and explore sarcopenia-related metabolomic changes.
7.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
8.Improving breast ultrasonography education: the impact of AI-based decision support on the performance of non-specialist medical professionals
Sangwon LEE ; Hye Sun LEE ; Eunju LEE ; Won Hwa KIM ; Jaeil KIM ; Jung Hyun YOON
Ultrasonography 2025;44(2):124-133
Purpose:
This study evaluated the educational impact of an artificial intelligence (AI)–based decision support system for breast ultrasonography (US) on medical professionals not specialized in breast imaging.
Methods:
In this multi-case, multi-reader study, educational materials, including American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) descriptors, were provided alongside corresponding AI results during training. The AI system presented results in the form of AIheatmaps, AI scores, and AI-provided BI-RADS assessment categories. Forty-two readers evaluated the test set in three sessions: the first session (S1) occurred before the educational intervention, the second session (S2) followed education without AI assistance, and the third session (S3) took place after education with AI assistance. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and overall performance, were compared between the sessions.
Results:
The mean sensitivity increased from 66.5% (95% confidence interval [CI], 59.2% to 73.7%) to 88.7% (95% CI, 84.1% to 93.3%), with a statistically significant difference (P<0.001), and the AUC non-significantly increased from 0.664 (95% CI, 0.606 to 0.723) to 0.684 (95% CI, 0.620 to 0.748) (P=0.300). Both measures were higher in S2 than in S1. The AI-achieved AUC was comparable to that of the expert reader (0.747 [95% CI, 0.640 to 0.855] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.217). Additionally, with AI assistance, the mean AUC for inexperienced readers was not significantly different from that of the expert reader (0.745 [95% CI, 0.660 to 0.830] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.120).
Conclusion
The mean AUC and sensitivity improved after incorporating AI into breast US education and interpretation. AI systems with high-level performance for breast US can potentially be used as educational tools in the interpretation of breast US images.
9.Improving breast ultrasonography education: the impact of AI-based decision support on the performance of non-specialist medical professionals
Sangwon LEE ; Hye Sun LEE ; Eunju LEE ; Won Hwa KIM ; Jaeil KIM ; Jung Hyun YOON
Ultrasonography 2025;44(2):124-133
Purpose:
This study evaluated the educational impact of an artificial intelligence (AI)–based decision support system for breast ultrasonography (US) on medical professionals not specialized in breast imaging.
Methods:
In this multi-case, multi-reader study, educational materials, including American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) descriptors, were provided alongside corresponding AI results during training. The AI system presented results in the form of AIheatmaps, AI scores, and AI-provided BI-RADS assessment categories. Forty-two readers evaluated the test set in three sessions: the first session (S1) occurred before the educational intervention, the second session (S2) followed education without AI assistance, and the third session (S3) took place after education with AI assistance. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and overall performance, were compared between the sessions.
Results:
The mean sensitivity increased from 66.5% (95% confidence interval [CI], 59.2% to 73.7%) to 88.7% (95% CI, 84.1% to 93.3%), with a statistically significant difference (P<0.001), and the AUC non-significantly increased from 0.664 (95% CI, 0.606 to 0.723) to 0.684 (95% CI, 0.620 to 0.748) (P=0.300). Both measures were higher in S2 than in S1. The AI-achieved AUC was comparable to that of the expert reader (0.747 [95% CI, 0.640 to 0.855] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.217). Additionally, with AI assistance, the mean AUC for inexperienced readers was not significantly different from that of the expert reader (0.745 [95% CI, 0.660 to 0.830] vs. 0.803 [95% CI, 0.706 to 0.900], P=0.120).
Conclusion
The mean AUC and sensitivity improved after incorporating AI into breast US education and interpretation. AI systems with high-level performance for breast US can potentially be used as educational tools in the interpretation of breast US images.
10.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.

Result Analysis
Print
Save
E-mail