1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Multimodality Imaging Features of Various Splenic Lesions: Clinical and Histopathologic Correlation
Yu Jin OH ; Jeong Eun LEE ; Sun Kyoung YOU ; Joon Young OHM ; Hyun Young HAN ; Jin Man KIM ; Kyung Sook SHIN
Journal of the Korean Society of Radiology 2024;85(6):1099-1125
The spleen is occasionally referred to as the ‘forgotten organ’ because splenic lesions are less common and encountered rarely compared to pathologies of other abdominal solid organs. Therefore, although well-demonstrated using various abdominal imaging modalities, radiologists tend to be less familiar with splenic diseases, making interpretation challenging. This study aimed to review common and uncommon splenic diseases and illustrate the multimodal imaging (including ultrasonography, CT, MRI, and PET/CT) features of these lesions in correlation with their histopathology. Recognizing the radiological findings of various splenic lesions helps narrow down the differential diagnosis and guide appropriate clinical decision-making for radiologists.
6.Flexor Digitorum Superficialis to Flexor Digitorum Profundus Tendon Transfer after Wide Excision of Myxoinflammatory Fibroblastic Sarcoma: A Case Report
Bo Hyun LEE ; Lan Sook CHANG ; Youn Hwan KIM ; Chang Hun LEE ; Seong Oh PARK
Journal of Wound Management and Research 2024;20(2):178-183
Myxoinflammatory fibroblastic sarcoma (MIFS) is a rare, low-grade soft tissue neoplasm that typically arises in the extremities. A 72-yearold woman presented with recurrent masses on her left forearm. Four years prior, she underwent an excisional biopsy, diagnosed as MIFS, followed by wide excision and split-thickness skin graft coverage. Preoperative magnetic resonance imaging was conducted for the recurrent mass, revealing multiple tumors invading the flexor digitorum profundus (FDP) muscle and fascia. The tumors including most of the FDP muscle were therefore excised. The third flexor digitorum superficialis (FDS) tendon was harvested, divided in half, and connected to the second and fifth FDP tendons. The same procedure was performed for the third and fourth FDP tendons with fourth FDS tendon. An anterolateral thigh free flap was used to reconstruct the skin and soft tissue defect of the left forearm. Adjuvant radiation therapy was performed. At 12 weeks postoperatively, the patient exhibited no wound complications and achieved spontaneous partial flexion of the metacarpophalangeal and proximal interphalangeal joints.
7.Multimodality Imaging Features of Various Splenic Lesions: Clinical and Histopathologic Correlation
Yu Jin OH ; Jeong Eun LEE ; Sun Kyoung YOU ; Joon Young OHM ; Hyun Young HAN ; Jin Man KIM ; Kyung Sook SHIN
Journal of the Korean Society of Radiology 2024;85(6):1099-1125
The spleen is occasionally referred to as the ‘forgotten organ’ because splenic lesions are less common and encountered rarely compared to pathologies of other abdominal solid organs. Therefore, although well-demonstrated using various abdominal imaging modalities, radiologists tend to be less familiar with splenic diseases, making interpretation challenging. This study aimed to review common and uncommon splenic diseases and illustrate the multimodal imaging (including ultrasonography, CT, MRI, and PET/CT) features of these lesions in correlation with their histopathology. Recognizing the radiological findings of various splenic lesions helps narrow down the differential diagnosis and guide appropriate clinical decision-making for radiologists.
8.Multimodality Imaging Features of Various Splenic Lesions: Clinical and Histopathologic Correlation
Yu Jin OH ; Jeong Eun LEE ; Sun Kyoung YOU ; Joon Young OHM ; Hyun Young HAN ; Jin Man KIM ; Kyung Sook SHIN
Journal of the Korean Society of Radiology 2024;85(6):1099-1125
The spleen is occasionally referred to as the ‘forgotten organ’ because splenic lesions are less common and encountered rarely compared to pathologies of other abdominal solid organs. Therefore, although well-demonstrated using various abdominal imaging modalities, radiologists tend to be less familiar with splenic diseases, making interpretation challenging. This study aimed to review common and uncommon splenic diseases and illustrate the multimodal imaging (including ultrasonography, CT, MRI, and PET/CT) features of these lesions in correlation with their histopathology. Recognizing the radiological findings of various splenic lesions helps narrow down the differential diagnosis and guide appropriate clinical decision-making for radiologists.
9.Identification of signature gene set as highly accurate determination of metabolic dysfunction-associated steatotic liver disease progression
Sumin OH ; Yang-Hyun BAEK ; Sungju JUNG ; Sumin YOON ; Byeonggeun KANG ; Su-hyang HAN ; Gaeul PARK ; Je Yeong KO ; Sang-Young HAN ; Jin-Sook JEONG ; Jin-Han CHO ; Young-Hoon ROH ; Sung-Wook LEE ; Gi-Bok CHOI ; Yong Sun LEE ; Won KIM ; Rho Hyun SEONG ; Jong Hoon PARK ; Yeon-Su LEE ; Kyung Hyun YOO
Clinical and Molecular Hepatology 2024;30(2):247-262
Background/Aims:
Metabolic dysfunction-associated steatotic liver disease (MASLD) is characterized by fat accumulation in the liver. MASLD encompasses both steatosis and MASH. Since MASH can lead to cirrhosis and liver cancer, steatosis and MASH must be distinguished during patient treatment. Here, we investigate the genomes, epigenomes, and transcriptomes of MASLD patients to identify signature gene set for more accurate tracking of MASLD progression.
Methods:
Biopsy-tissue and blood samples from patients with 134 MASLD, comprising 60 steatosis and 74 MASH patients were performed omics analysis. SVM learning algorithm were used to calculate most predictive features. Linear regression was applied to find signature gene set that distinguish the stage of MASLD and to validate their application into independent cohort of MASLD.
Results:
After performing WGS, WES, WGBS, and total RNA-seq on 134 biopsy samples from confirmed MASLD patients, we provided 1,955 MASLD-associated features, out of 3,176 somatic variant callings, 58 DMRs, and 1,393 DEGs that track MASLD progression. Then, we used a SVM learning algorithm to analyze the data and select the most predictive features. Using linear regression, we identified a signature gene set capable of differentiating the various stages of MASLD and verified it in different independent cohorts of MASLD and a liver cancer cohort.
Conclusions
We identified a signature gene set (i.e., CAPG, HYAL3, WIPI1, TREM2, SPP1, and RNASE6) with strong potential as a panel of diagnostic genes of MASLD-associated disease.
10.Early Prediction of Mortality for Septic Patients Visiting Emergency Room Based on Explainable Machine Learning: A Real-World Multicenter Study
Sang Won PARK ; Na Young YEO ; Seonguk KANG ; Taejun HA ; Tae-Hoon KIM ; DooHee LEE ; Dowon KIM ; Seheon CHOI ; Minkyu KIM ; DongHoon LEE ; DoHyeon KIM ; Woo Jin KIM ; Seung-Joon LEE ; Yeon-Jeong HEO ; Da Hye MOON ; Seon-Sook HAN ; Yoon KIM ; Hyun-Soo CHOI ; Dong Kyu OH ; Su Yeon LEE ; MiHyeon PARK ; Chae-Man LIM ; Jeongwon HEO ; On behalf of the Korean Sepsis Alliance (KSA) Investigators
Journal of Korean Medical Science 2024;39(5):e53-
Background:
Worldwide, sepsis is the leading cause of death in hospitals. If mortality rates in patients with sepsis can be predicted early, medical resources can be allocated efficiently. We constructed machine learning (ML) models to predict the mortality of patients with sepsis in a hospital emergency department.
Methods:
This study prospectively collected nationwide data from an ongoing multicenter cohort of patients with sepsis identified in the emergency department. Patients were enrolled from 19 hospitals between September 2019 and December 2020. For acquired data from 3,657 survivors and 1,455 deaths, six ML models (logistic regression, support vector machine, random forest, extreme gradient boosting [XGBoost], light gradient boosting machine, and categorical boosting [CatBoost]) were constructed using fivefold cross-validation to predict mortality. Through these models, 44 clinical variables measured on the day of admission were compared with six sequential organ failure assessment (SOFA) components (PaO 2 /FIO 2 [PF], platelets (PLT), bilirubin, cardiovascular, Glasgow Coma Scale score, and creatinine).The confidence interval (CI) was obtained by performing 10,000 repeated measurements via random sampling of the test dataset. All results were explained and interpreted using Shapley’s additive explanations (SHAP).
Results:
Of the 5,112 participants, CatBoost exhibited the highest area under the curve (AUC) of 0.800 (95% CI, 0.756–0.840) using clinical variables. Using the SOFA components for the same patient, XGBoost exhibited the highest AUC of 0.678 (95% CI, 0.626–0.730). As interpreted by SHAP, albumin, lactate, blood urea nitrogen, and international normalization ratio were determined to significantly affect the results. Additionally, PF and PLTs in the SOFA component significantly influenced the prediction results.
Conclusion
Newly established ML-based models achieved good prediction of mortality in patients with sepsis. Using several clinical variables acquired at the baseline can provide more accurate results for early predictions than using SOFA components. Additionally, the impact of each variable was identified.

Result Analysis
Print
Save
E-mail