1.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
2.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
3.Brain Injury and Short-Term Neurodevelopmental Outcomes in Neonates Treated with Respiratory Extracorporeal Membrane Oxygenation: A Single-Center Experience
Keon Hee SEOL ; Byong Sop LEE ; Kyusang YOO ; Joo Hyung ROH ; Jeong Min LEE ; Jung Il KWAK ; Tae-Gyeong KIM ; Juhee PARK ; Ha Na LEE ; Chae Young KIM ; Soo Hyun KIM ; Ji Yoon JEONG ; Euiseok JUNG
Neonatal Medicine 2025;32(1):39-48
Purpose:
This study aimed to characterize the clinical patterns and severity of brain injury in neonates who survived extracorporeal membrane oxygenation (ECMO) therapy for acute respiratory failure during the neonatal period, to evaluate their short-term neurodevelopmental outcomes, and to identify the factors associated with these outcomes.
Methods:
We retrospectively reviewed the medical records of neonates who survived ECMO between 2018 and 2024. Based on brain magnetic resonance imaging (MRI) findings, the patients were classified into two groups: no/mild and moderate/severe brain injury. Neurodevelopmental outcomes were assessed at 12–40 months of age using the Bayley Scale of Infant Development II/III and/or the Korean Developmental Screening Test.
Results:
Among the 19 neonates included in the study, 18 (94.7%) showed varying degrees of brain injury on MRI (mild: 12, moderate: 1, severe: 5). Neonates with moderate/severe brain injury had significantly longer durations of ECMO support and extended durations of mechanical ventilation and were more likely to receive continuous renal replacement therapy than those with no or mild injury. Developmental delay was identified in 36.8% of survivors and was significantly associated with prolonged mechanical ventilation, longer neonatal intensive care unit stays, and a higher incidence of seizures.
Conclusion
Brain injury is frequently observed on MRI in neonates treated with ECMO. However, its direct association with adverse neurodevelopmental outcomes is not definitive. Since MRI findings alone cannot predict developmental outcomes, clinical and environmental factors should be integrated into prognostic assessments.
6.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.The Korean Organ Transplant Registry (KOTRY): Third Official Adult Heart Transplant Report
Hyo-In CHOI ; Sang Eun LEE ; Junho HYUN ; Darae KIM ; Dong-Ju CHOI ; Eun-Seok JEON ; Hae-Young LEE ; Hyun-Jai CHO ; Hyungseop KIM ; In-Cheol KIM ; Jaewon OH ; Minjae YOON ; Jin Joo PARK ; Jin-Oh CHOI ; Min Ho JU ; Seok-Min KANG ; Soo Yong LEE ; Sung-Ho JUNG ; Jae-Joong KIM
Korean Circulation Journal 2025;55(2):79-96
Background and Objectives:
The Korean Organ Transplant Registry (KOTRY) provided data for this third official report on adult heart transplantation (HT), including information from 709 recipients.
Methods:
Data from HTs performed at seven major centers in Korea between March 2014 and December 2020 were analyzed, focusing on immunosuppression, acute rejection, cardiac allograft vasculopathy (CAV), post-transplant survival, and mechanical circulatory support (MCS) usage.
Results:
The median ages of the recipients and donors were 56.0 and 43.0 years, respectively.Cardiomyopathy and ischemic heart disease were the most common preceding conditions for HT. A significant portion of patients underwent HT at waiting list status 1 and 0. In the multivariate analysis, a predicted heart mass mismatch was associated with a higher risk of 1-year mortality. Patients over 70 years old had a significantly increased risk of 6-year mortality. The risk of CAV was higher for male donors and donors older than 45 years. Acute rejection was more likely in patients with panel reactive antibody levels above 80%, while statin use was associated with a reduced risk. The employment of left ventricular assist device as a bridge to transplantation increased from 2.17% to 22.4%. Pre-transplant extra-corporeal membrane oxygenation was associated with worse post-transplant survival.
Conclusions
In this third KOTRY report, we analyzed changes in the characteristics of adult HT recipients and donors and their impact on post-transplant outcomes. The most notable discovery was the increased use of MCS before HT and their impact on post-transplant outcomes.
8.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
9.Comparison of combined intranasal dexmedetomidine and ketamine versus chloral hydrate for pediatric procedural sedation: a randomized controlled trial
Young-Eun JANG ; Eun-Young JOO ; Jung-Bin PARK ; Sang-Hwan JI ; Eun-Hee KIM ; Ji-Hyun LEE ; Hee-Soo KIM ; Jin-Tae KIM
Korean Journal of Anesthesiology 2025;78(3):248-260
Background:
We hypothesized that intranasal combination of dexmedetomidine (2 μg/kg) and ketamine (3 mg/kg) (IN DEXKET) improves the success rate of sedation in pediatric patients compared with chloral hydrate (CH; 50 mg/kg).
Methods:
This prospective, two-center, single-blinded, randomized controlled trial involved 136 pediatric patients (aged < 7 years) requiring procedural sedation. The participants were randomized to receive CH or IN DEXKET via a mucosal atomizer device. The primary outcome was the success rate of sedation (Pediatric Sedation State Scale, scores 1–3) within 15 min. The secondary outcomes included sedation failure at 30 min and overall complications of first-attempt sedation.
Results:
After excluding eight patients, 128 were included (CH = 66, IN DEXKET = 62). IN DEXKET showed a similar sedation success rate (75.8% [47/62] vs. 66.7% [44/66]; P = 0.330) but a lower complication rate (3.2% [2/62] vs. 16.7% [11/66]; P = 0.017) than CH. In the subgroup analysis for patients aged < 1 year, IN DEXKET showed a reduced complication rate than CH (2.6% [1/38] vs. 22.9% [8/35]; P = 0.012). In the subgroup analysis of children aged 1–7 years, IN DEXKET showed a higher sedation success rate within 15 min (79.2% [19/24] vs. 51.6% [16/31]; P = 0.049) and a lower sedation failure after 30 min (0% vs. 29.0% [9/31]; P = 0.003) than CH.
Conclusions
The intranasal combination of dexmedetomidine (2 μg/kg) and ketamine (3 mg/kg) is a safe and effective alternative to CH (50 mg/kg) for sedation in pediatric patients aged < 7 years.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail