1.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
2.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
3.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
4.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
5.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
6.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
7.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
8.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
9.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
10.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.

Result Analysis
Print
Save
E-mail