1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation
Jung-Min KIM ; Hyung-Ku YOON ; Gi-Ho MOON ; Joo-Suk AHN ; Kyu-Hyun YANG
Clinics in Orthopedic Surgery 2025;17(1):71-79
Background:
Decreased acetabular version and posterior acetabular coverage of the femoral head have been regarded as the leading causes of sport-related posterior hip dislocation or subluxation. This study aimed to examine the posterior acetabular coverage of the femoral head in 21 patients who sustained posterior hip dislocation or subluxation during sport activities.
Methods:
The anterior and posterior acetabular rims on 3-dimensional computed tomography (3D-CT) images were delineated on the normal side in these patients. Radiologic signs, including crossover and posterior wall signs, were examined. The fracture center level (FCL) of the posterior acetabular wall was identified on axial CT images of the injured hip and the level was marked on the normal side. The difference in the femoral head coverage by posterior and anterior acetabular rims was measured by measuring the horizontal distance between anterior and posterior acetabular rims at the FCL (posterior-anterior [P-A] index). The acetabular version was measured at the femoral head and FCL using axial CT images of the normal side. Femoral head coverage by the posterior acetabular wall on the normal side was measured using 3D-CT (areal coverage).
Results:
The crossover and posterior wall signs were positive in 14 and 10 patients, respectively, in 3D-CT images. The FCL was evenly distributed in the proximal half of the posterior acetabular wall. Seven patients had a P-A index of ≤ 0, and all were positive for the crossover sign. The anterior acetabular rim was relatively prominent in these patients. The acetabular version was lower at the FCL than at the femoral head center (p < 0.001). The proximal half areal coverage of the posterior acetabular wall was significantly smaller than the whole areal coverage (p = 0.003).
Conclusions
Superior–posterior coverage of the femoral head by the posterior acetabular wall was insufficient in patients who sustained hip posterior dislocation or subluxation during sports activities.
4.Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation
Jung-Min KIM ; Hyung-Ku YOON ; Gi-Ho MOON ; Joo-Suk AHN ; Kyu-Hyun YANG
Clinics in Orthopedic Surgery 2025;17(1):71-79
Background:
Decreased acetabular version and posterior acetabular coverage of the femoral head have been regarded as the leading causes of sport-related posterior hip dislocation or subluxation. This study aimed to examine the posterior acetabular coverage of the femoral head in 21 patients who sustained posterior hip dislocation or subluxation during sport activities.
Methods:
The anterior and posterior acetabular rims on 3-dimensional computed tomography (3D-CT) images were delineated on the normal side in these patients. Radiologic signs, including crossover and posterior wall signs, were examined. The fracture center level (FCL) of the posterior acetabular wall was identified on axial CT images of the injured hip and the level was marked on the normal side. The difference in the femoral head coverage by posterior and anterior acetabular rims was measured by measuring the horizontal distance between anterior and posterior acetabular rims at the FCL (posterior-anterior [P-A] index). The acetabular version was measured at the femoral head and FCL using axial CT images of the normal side. Femoral head coverage by the posterior acetabular wall on the normal side was measured using 3D-CT (areal coverage).
Results:
The crossover and posterior wall signs were positive in 14 and 10 patients, respectively, in 3D-CT images. The FCL was evenly distributed in the proximal half of the posterior acetabular wall. Seven patients had a P-A index of ≤ 0, and all were positive for the crossover sign. The anterior acetabular rim was relatively prominent in these patients. The acetabular version was lower at the FCL than at the femoral head center (p < 0.001). The proximal half areal coverage of the posterior acetabular wall was significantly smaller than the whole areal coverage (p = 0.003).
Conclusions
Superior–posterior coverage of the femoral head by the posterior acetabular wall was insufficient in patients who sustained hip posterior dislocation or subluxation during sports activities.
5.Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation
Jung-Min KIM ; Hyung-Ku YOON ; Gi-Ho MOON ; Joo-Suk AHN ; Kyu-Hyun YANG
Clinics in Orthopedic Surgery 2025;17(1):71-79
Background:
Decreased acetabular version and posterior acetabular coverage of the femoral head have been regarded as the leading causes of sport-related posterior hip dislocation or subluxation. This study aimed to examine the posterior acetabular coverage of the femoral head in 21 patients who sustained posterior hip dislocation or subluxation during sport activities.
Methods:
The anterior and posterior acetabular rims on 3-dimensional computed tomography (3D-CT) images were delineated on the normal side in these patients. Radiologic signs, including crossover and posterior wall signs, were examined. The fracture center level (FCL) of the posterior acetabular wall was identified on axial CT images of the injured hip and the level was marked on the normal side. The difference in the femoral head coverage by posterior and anterior acetabular rims was measured by measuring the horizontal distance between anterior and posterior acetabular rims at the FCL (posterior-anterior [P-A] index). The acetabular version was measured at the femoral head and FCL using axial CT images of the normal side. Femoral head coverage by the posterior acetabular wall on the normal side was measured using 3D-CT (areal coverage).
Results:
The crossover and posterior wall signs were positive in 14 and 10 patients, respectively, in 3D-CT images. The FCL was evenly distributed in the proximal half of the posterior acetabular wall. Seven patients had a P-A index of ≤ 0, and all were positive for the crossover sign. The anterior acetabular rim was relatively prominent in these patients. The acetabular version was lower at the FCL than at the femoral head center (p < 0.001). The proximal half areal coverage of the posterior acetabular wall was significantly smaller than the whole areal coverage (p = 0.003).
Conclusions
Superior–posterior coverage of the femoral head by the posterior acetabular wall was insufficient in patients who sustained hip posterior dislocation or subluxation during sports activities.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation
Jung-Min KIM ; Hyung-Ku YOON ; Gi-Ho MOON ; Joo-Suk AHN ; Kyu-Hyun YANG
Clinics in Orthopedic Surgery 2025;17(1):71-79
Background:
Decreased acetabular version and posterior acetabular coverage of the femoral head have been regarded as the leading causes of sport-related posterior hip dislocation or subluxation. This study aimed to examine the posterior acetabular coverage of the femoral head in 21 patients who sustained posterior hip dislocation or subluxation during sport activities.
Methods:
The anterior and posterior acetabular rims on 3-dimensional computed tomography (3D-CT) images were delineated on the normal side in these patients. Radiologic signs, including crossover and posterior wall signs, were examined. The fracture center level (FCL) of the posterior acetabular wall was identified on axial CT images of the injured hip and the level was marked on the normal side. The difference in the femoral head coverage by posterior and anterior acetabular rims was measured by measuring the horizontal distance between anterior and posterior acetabular rims at the FCL (posterior-anterior [P-A] index). The acetabular version was measured at the femoral head and FCL using axial CT images of the normal side. Femoral head coverage by the posterior acetabular wall on the normal side was measured using 3D-CT (areal coverage).
Results:
The crossover and posterior wall signs were positive in 14 and 10 patients, respectively, in 3D-CT images. The FCL was evenly distributed in the proximal half of the posterior acetabular wall. Seven patients had a P-A index of ≤ 0, and all were positive for the crossover sign. The anterior acetabular rim was relatively prominent in these patients. The acetabular version was lower at the FCL than at the femoral head center (p < 0.001). The proximal half areal coverage of the posterior acetabular wall was significantly smaller than the whole areal coverage (p = 0.003).
Conclusions
Superior–posterior coverage of the femoral head by the posterior acetabular wall was insufficient in patients who sustained hip posterior dislocation or subluxation during sports activities.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Quality Indicators of Endoscopic Retrograde Cholangiopancreatography in Korea
Hyung Ku CHON ; Ki-Hyun KIM ; Tae Jun SONG ; Dong-Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Jin-Seok PARK ; Seung Bae YOON ; Kwang Hyun CHUNG ; Jin LEE ; Miyoung CHOI
Gut and Liver 2024;18(4):564-577
Endoscopic retrograde cholangiopancreatography (ERCP) is a procedure that requires significant experiences and skills and has various procedure-related complications, some of which can be severe and even result in the death of patients. Expanding ERCP availability has the advantage of increasing accessibility for patients. However, ERCP poses a substantial risk if performed without proper quality management. ERCP quality management is essential for both ensuring safe and successful procedures and meeting the social demands for enhanced healthcare competitiveness and quality assurance. To address these concerns, the Korean Pancreatobiliary Association established a task force to develop ERCP quality indicators (QIs) tailored to the Korean medical environment. Key questions for five pre-procedure, three intra-procedure, and four post-procedure measures were formulated based on a literature search related to ERCP QIs and a comprehensive clinical review conducted by experts. The statements and recommendations regarding each QI item were selected through peer review. The developed ERCP QIs were reviewed by external experts based on the latest available evidence at the time of development.These domestically tailored ERCP QIs are expected to contribute considerably to improving ERCP quality in Korea.
10.Omission of Breast Surgery in Predicted Pathologic Complete Response after Neoadjuvant Systemic Therapy: A Multicenter, Single-Arm, Non-inferiority Trial
Ji-Jung JUNG ; Jong-Ho CHEUN ; Soo-Yeon KIM ; Jiwon KOH ; Jai Min RYU ; Tae-Kyung YOO ; Hee-Chul SHIN ; Sung Gwe AHN ; Seho PARK ; Woosung LIM ; Sang-Eun NAM ; Min Ho PARK ; Ku Sang KIM ; Taewoo KANG ; Jeeyeon LEE ; Hyun Jo YOUN ; Yoo Seok KIM ; Chang Ik YOON ; Hong-Kyu KIM ; Hyeong-Gon MOON ; Wonshik HAN ; Nariya CHO ; Min Kyoon KIM ; Han-Byoel LEE
Journal of Breast Cancer 2024;27(1):61-71
Purpose:
Advances in chemotherapeutic and targeted agents have increased pathologic complete response (pCR) rates after neoadjuvant systemic therapy (NST). Vacuum-assisted biopsy (VAB) has been suggested to accurately evaluate pCR. This study aims to confirm the non-inferiority of the 5-year disease-free survival of patients who omitted breast surgery when predicted to have a pCR based on breast magnetic resonance imaging (MRI) and VAB after NST, compared with patients with a pCR who had undergone breast surgery in previous studies.
Methods
The Omission of breast surgery for PredicTed pCR patients wIth MRI and vacuumassisted bIopsy in breaST cancer after neoadjuvant systemic therapy (OPTIMIST) trial is a prospective, multicenter, single-arm, non-inferiority study enrolling in 17 tertiary care hospitals in the Republic of Korea. Eligible patients must have a clip marker placed in the tumor and meet the MRI criteria suggesting complete clinical response (post-NST MRI size ≤ 1 cm and lesion-to-background signal enhancement ratio ≤ 1.6) after NST. Patients will undergo VAB, and breast surgery will be omitted for those with no residual tumor. Axillary surgery can also be omitted if the patient was clinically node-negative before and after NST and met the stringent criteria of MRI size ≤ 0.5 cm. Survival and efficacy outcomes are evaluated over five years.Discussion: This study seeks to establish evidence for the safe omission of breast surgery in exceptional responders to NST while minimizing patient burden. The trial will address concerns about potential undertreatment due to false-negative results and recurrence as well as improved patient-reported quality of life issues from the omission of surgery. Successful completion of this trial may reshape clinical practice for certain breast cancer subtypes and lead to a safe and less invasive approach for selected patients.

Result Analysis
Print
Save