1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.The Profile of Early Sedation Depth and Clinical Outcomes of Mechanically Ventilated Patients in Korea
Dong-gon HYUN ; Jee Hwan AHN ; Ha-Yeong GIL ; Chung Mo NAM ; Choa YUN ; Jae-Myeong LEE ; Jae Hun KIM ; Dong-Hyun LEE ; Ki Hoon KIM ; Dong Jung KIM ; Sang-Min LEE ; Ho-Geol RYU ; Suk-Kyung HONG ; Jae-Bum KIM ; Eun Young CHOI ; JongHyun BAEK ; Jeoungmin KIM ; Eun Jin KIM ; Tae Yun PARK ; Je Hyeong KIM ; Sunghoon PARK ; Chi-Min PARK ; Won Jai JUNG ; Nak-Jun CHOI ; Hang-Jea JANG ; Su Hwan LEE ; Young Seok LEE ; Gee Young SUH ; Woo-Sung CHOI ; Keu Sung LEE ; Hyung Won KIM ; Young-Gi MIN ; Seok Jeong LEE ; Chae-Man LIM
Journal of Korean Medical Science 2023;38(19):e141-
Background:
Current international guidelines recommend against deep sedation as it is associated with worse outcomes in the intensive care unit (ICU). However, in Korea the prevalence of deep sedation and its impact on patients in the ICU are not well known.
Methods:
From April 2020 to July 2021, a multicenter, prospective, longitudinal, noninterventional cohort study was performed in 20 Korean ICUs. Sedation depth extent was divided into light and deep using a mean Richmond Agitation–Sedation Scale value within the first 48 hours. Propensity score matching was used to balance covariables; the outcomes were compared between the two groups.
Results:
Overall, 631 patients (418 [66.2%] and 213 [33.8%] in the deep and light sedation groups, respectively) were included. Mortality rates were 14.1% and 8.4% in the deep and light sedation groups (P = 0.039), respectively. Kaplan-Meier estimates showed that time to extubation (P < 0.001), ICU length of stay (P = 0.005), and death P = 0.041) differed between the groups. After adjusting for confounders, early deep sedation was only associated with delayed time to extubation (hazard ratio [HR], 0.66; 95% confidence inter val [CI], 0.55– 0.80; P < 0.001). In the matched cohort, deep sedation remained significantly associated with delayed time to extubation (HR, 0.68; 95% 0.56–0.83; P < 0.001) but was not associated with ICU length of stay (HR, 0.94; 95% CI, 0.79–1.13; P = 0.500) and in-hospital mortality (HR, 1.19; 95% CI, 0.65–2.17; P = 0.582).
Conclusion
In many Korean ICUs, early deep sedation was highly prevalent in mechanically ventilated patients and was associated with delayed extubation, but not prolonged ICU stay or in-hospital death.
7.The Clinical Outcomes of Marginal Donor Hearts: A Single Center Experience
Soo Yong LEE ; Seok Hyun KIM ; Min Ho JU ; Mi Hee LIM ; Chee-hoon LEE ; Hyung Gon JE ; Ji Hoon LIM ; Ga Yun KIM ; Ji Soo OH ; Jin Hee CHOI ; Min Ku CHON ; Sang Hyun LEE ; Ki Won HWANG ; Jeong Su KIM ; Yong Hyun PARK ; June Hong KIM ; Kook Jin CHUN
Korean Circulation Journal 2023;53(4):254-267
Background and Objectives:
Although the shortage of donor is a common problem worldwide, a significant portion of unutilized hearts are classified as marginal donor (MD) hearts. However, research on the correlation between the MD and the prognosis of heart transplantation (HTx) is lacking. This study was conducted to investigate the clinical impact of MD in HTx.
Methods:
Consecutive 73 HTxs during 2014 and 2021 in a tertiary hospital were analyzed.MD was defined as follows; a donor age >55 years, left ventricular ejection fraction <50%, cold ischemic time >240 minutes, or significant cardiac structural problems. Preoperative characteristics and postoperative hemodynamic data, primary graft dysfunction (PGD), and the survival rate were analyzed. Risk stratification by Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was performed to examine the outcomes according to the recipient state. Each group was sub-divided into 2 risk groups according to the IMPACT score (low <10 vs. high ≥10).
Results:
A total of 32 (43.8%) patients received an organ from MDs. Extracorporeal membrane oxygenation was more frequent in the non-MD group (34.4% vs. 70.7, p=0.007) There was no significant difference in PGD, 30-day mortality and long-term survival between groups. In the subgroup analysis, early outcomes did not differ between low- and high-risk groups. However, the long-term survival was better in the low-risk group (p=0.01).
Conclusions
The outcomes of MD group were not significantly different from non-MD group. Particularly, in low-risk recipient, the MD group showed excellent early and longterm outcomes. These results suggest the usability of selected MD hearts without increasing adverse events.
8.A Case of Endocarditis on Mitral Annular Calcification
Jin Hee CHOI ; Yong Hyun PARK ; Sang Hyun LEE ; Soo Yong LEE ; Hyung Gon JE
Korean Circulation Journal 2022;52(1):89-92
no abstract available.
9.Hip Resurfacing Arthroplasty after Failure of Tantalum Rod Insertion in Patients with Osteonecrosis of the Femoral Head
Yoon Je CHO ; Kee Hyung RHYU ; Young Soo CHUN ; Hyun Gon GWAK
Hip & Pelvis 2022;34(4):219-226
Purpose:
The purpose of this study was to examine the clinical outcomes and efficacy of hip resurfacing arthroplasty (HRA) in patients with osteonecrosis of the femoral head after the failure of porous tantalum rod insertion without rod removal.
Materials and Methods:
Conversion to hip resurfacing arthroplasty was performed in 10 patients (11 hips) with a mean period of 14.9 months after the primary surgery. The mean follow-up period was 73.7 months. Analysis of pre and postoperative range of motion (ROM), University of California at Los Angeles (UCLA) activity score, modified Harris hip score, and visual analog scale (VAS) pain score was performed. Radiographic analysis of component loosening and osteolysis was performed.
Results:
The postoperative ROM showed significant improvement (P<0.05), excluding flexion contracture. The modified Harris hip score showed improvement from 65.82 to 96.18, the UCLA score showed improvement from 4.18 to 8.00, and the VAS pain score was reduced from 6.09 to 1.80. All scores showed statistically significant improvement (P<0.05). No component loosening or osteolysis was detected by radiographic analysis.
Conclusion
Satisfactory results were obtained from conversion hip resurfacing arthroplasty after failure of porous tantalum rod insertion without rod removal. The findings of this study demonstrate the advantages of HRA, including no risk of trochanteric fracture and no bone loss around the tantalum rod. In addition, the remaining porous tantalum rod provided mechanical support, which reduced the potential risk of femoral neck fracture or loosening. This technique can be regarded as a favorable treatment option.
10.Successful Desensitization by Post-Centrifugal Plasma Filtration in Two Highly Sensitized Heart and Lung Transplant Recipients
Hyun-Ji LEE ; Kyung-Hwa SHIN ; Hyung-Hoi KIM ; Hyung Gon JE ; Dohyung KIM ; Woo Hyun CHO ; Jeong Su KIM ; Soo Yong LEE ; Hye Ju YEO
Annals of Laboratory Medicine 2020;40(5):431-434

Result Analysis
Print
Save
E-mail