1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.A Case of Pituitary Rathke’s Cleft Cyst Associated with Decreased Visual Acuity after Cataract Surgery
Min Sun KIM ; Young Chae YOON ; Sun Kyoung PARK ; Woong Joo WHANG ; Ho Sik HWANG ; Hyun Seung KIM ; Kyung Sun NA ; Mira PARK
Annals of Optometry and Contact Lens 2024;23(2):85-90
Purpose:
To report a case of suprasellar Rathke's cleft cyst accompanying visual field defect found in a patient complaining of decreased visual acuity after cataract surgery.Case Summary: A 62-year-old male patient who showed a best-corrected visual acuity (BCVA) of 0.6 after left eye cataract surgery visited our hospital two months after surgery with decreased vision. He showed a best corrected visual acuity of 0.2, did not have relative afferent pupillary defect, and there were no specific findings on fundus examination. In the full field perimetry test, partial visual field loss in superior temporal quadrants were found in both eyes, being more prominent in left eye. In ganglion cell layer measurements using optical coherence tomography, a symmetric thinning in the thickness of the nasal ganglion cell layer was observed in both eyes, which was consistent with the visual field test. It was discovered that a liquid solid mass with a diameter of 21 mm in the upper part of the pituitary gland was compressing the optic chiasm in orbit magnetic resonance imaging. The patient was then referred to neurosurgery for pituitary surgery using transsphenoidal approach and diagnosed with Rathke's cleft cyst on histopathologic examination. Three months after surgery, the BCVA has increased to 0.5 and the visual field test showed no scotoma.
Conclusions
We report a case that Rathke's cleft cyst above the sella turcica inducing visual disturbances, emphasizing the importance of early detection and treatment through neuroophthalmological evaluation in a patient presenting with unexplained visual impairment.
5.Oxidized LDL Accelerates CartilageDestruction and Inflammatory Chondrocyte Death in Osteoarthritis by Disrupting the TFEB-Regulated Autophagy-Lysosome Pathway
Jeong Su LEE ; Yun Hwan KIM ; JooYeon JHUN ; Hyun Sik NA ; In Gyu UM ; Jeong Won CHOI ; Jin Seok WOO ; Seung Hyo KIM ; Asode Ananthram SHETTY ; Seok Jung KIM ; Mi-La CHO
Immune Network 2024;24(3):e15-
Osteoarthritis (OA) involves cartilage degeneration, thereby causing inflammation and pain. Cardiovascular diseases, such as dyslipidemia, are risk factors for OA; however, the mechanism is unclear. We investigated the effect of dyslipidemia on the development of OA. Treatment of cartilage cells with low-density lipoprotein (LDL) enhanced abnormal autophagy but suppressed normal autophagy and reduced the activity of transcription factor EB (TFEB), which is important for the function of lysosomes. Treatment of LDL-exposed chondrocytes with rapamycin, which activates TFEB, restored normal autophagy. Also, LDL enhanced the inflammatory death of chondrocytes, an effect reversed by rapamycin. In an animal model of hyperlipidemia-associated OA, dyslipidemia accelerated the development of OA, an effect reversed by treatment with a statin, an anti-dyslipidemia drug, or rapamycin, which activates TFEB. Dyslipidemia reduced the autophagic flux and induced necroptosis in the cartilage tissue of patients with OA. The levels of triglycerides, LDL, and total cholesterol were increased in patients with OA compared to those without OA. The C-reactive protein level of patients with dyslipidemia was higher than that of those without dyslipidemia after total knee replacement arthroplasty. In conclusion, oxidized LDL, an important risk factor of dyslipidemia, inhibited the activity of TFEB and reduced the autophagic flux, thereby inducing necroptosis in chondrocytes.
6.Pre‑ and post‑hemodialysis differences in heart failure diagnosis by current heart failure guidelines in patients with end‑stage renal disease
Bong‑Joon KIM ; Su‑Hyun BAE ; Soo‑Jin KIM ; Sung‑Il IM ; Hyunsu KIM ; Jung‑Ho HEO ; Ho Sik SHIN ; Ye Na KIM ; Yeonsoon JUNG ; Hark RIM
Journal of Cardiovascular Imaging 2024;32(1):6-
Background:
Patients with end-stage renal disease (ESRD) who are on hemodialysis (HD) have reduced vascular com‑ pliance and are likely to develop heart failure (HF). In this study, we estimated the prevalence of HF pre- and post-HD in ESRD using the current guidelines.
Methods:
We prospectively investigated HF in ESRD patients on HD using echocardiography pre- and post-HD. We used the structural and functional abnormality criteria of the 2021 European Society of Cardiology guidelines.
Results:
A total of 54 patients were enrolled. The mean age was 62.6 years, and 40.1% were male. Forty-five patients (83.3%) had hypertension, 28 (51.9%) had diabetes, and 20 (37.0%) had ischemic heart disease. The mean N-terminalpro brain natriuretic peptide BNP (NT-proBNP) level was 12,388.8 ± 2,592.2 pg/dL. The mean ideal body weight was 59.3 kg, mean hemodialysis time was 237.4 min, and mean real filtration was 2.8 kg. The mean left ventricular ejection fraction (LVEF) was 62.4%, and mean left ventricular end-diastolic diameter was 52.0 mm in pre-HD. Post-HD echocardiography showed significantly lower left atrial volume index (33.3 ± 15.9 vs. 40.6 ± 17.1, p = 0.030), tricuspid regurgitation jet V (2.5 ± 0.4 vs. 2.8 ± 0.4 m/s, p < 0.001), and right ventricular systolic pressure (32.1 ± 10.3 vs. 38.4 ± 11.6, p = 0.005) compared with pre-HD. There were no differences in LVEF, E/E′ ratio, or left ventricular global longitudinal strain. A total of 88.9% of pre-HD patients and 66.7% of post-HD patients had either structural or functional abnor‑ malities in echocardiographic parameters according to recent HF guidelines (p = 0.007).
Conclusions
Our data showed that the majority of patients undergoing hemodialysis satisfy the diagnostic criteria for HF according to current HF guidelines. Pre-HD patients had a 22.2% higher incidence in the prevalence of func‑ tional or structural abnormalities as compared with post-HD patients.
7.Impact of Infection Prevention Programs on Catheter-Associated Urinary Tract Infections Analyzed in Multicenter Study
Sun Hee NA ; Joong Sik EOM ; Yu Bin SEO ; Sun Hee PARK ; Young Keun KIM ; Wonkeun SONG ; Eunjung LEE ; Sung Ran KIM ; Hyeon Mi YOO ; Heekyung CHUN ; Myoung Jin SHIN ; Su Hyun KIM ; Ji Youn CHOI ; Nan hyoung CHO ; Jin Hwa KIM ; Hee-jung SON ; Su ha HAN ; Jacob LEE
Journal of Korean Medical Science 2024;39(18):e151-
Background:
Catheter-associated urinary tract infections (CAUTIs) account for a large proportion of healthcare-associated infections and have a significant impact on morbidity, length of hospital stay, and mortality. Adherence to the recommended infection prevention practices can effectively reduce the incidence of CAUTIs. This study aimed to assess the characteristics of CAUTIs and the efficacy of prevention programs across hospitals of various sizes.
Methods:
Intervention programs, including training, surveillance, and monitoring, were implemented. Data on the microorganisms responsible for CAUTIs, urinary catheter utilization ratio, rate of CAUTIs per 1,000 device days, and factors associated with the use of indwelling catheters were collected from 2017 to 2019. The incidence of CAUTIs and associated data were compared between university hospitals and small- and medium-sized hospitals.
Results:
Thirty-two hospitals participated in the study, including 21 university hospitals and 11 small- and medium-sized hospitals. The microorganisms responsible for CAUTIs and their resistance rates did not differ between the two groups. In the first quarter of 2018, the incidence rate was 2.05 infections/1,000 device-days in university hospitals and 1.44 infections/1,000 device-days in small- and medium-sized hospitals. After implementing interventions, the rate gradually decreased in the first quarter of 2019, with 1.18 infections/1,000 device-days in university hospitals and 0.79 infections/1,000 device-days in small- and medium-sized hospitals. However, by the end of the study, the infection rate increased to 1.74 infections/1,000 device-days in university hospitals and 1.80 infections/1,000 device-days in small- and medium-sized hospitals.
Conclusion
We implemented interventions to prevent CAUTIs and evaluated their outcomes. The incidence of these infections decreased in the initial phases of the intervention when adequate support and personnel were present. The rate of these infections may be reduced by implementing active interventions such as consistent monitoring and adherence to guidelines for preventing infections.
8.Development of an Instrument for Slit-lamp Examination of Donor Corneas in Preservation Medium
Ga Hee NAM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2024;65(2):108-116
Purpose:
To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium.
Methods:
The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas.
Results:
Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument.
Conclusions
The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.
9.The Diagnosis and Treatment of a Post-traumatic Iris Cyst Referred as an Iris Tumor
Ji Hyun YOON ; Young Chae YOON ; Sun Kyoung PARK ; Woong Joo WHANG ; Ho Sik HWANG ; Hyun Seung KIM ; Kyung Sun NA
Journal of the Korean Ophthalmological Society 2024;65(6):400-406
Purpose:
We report the diagnosis and treatment of a secondary iris cyst in a patient referred for an iris tumor.Case summary: A 29-year-old man diagnosed with an anterior chamber mass of the left eye was referred to our center for further evaluation and management. Twenty years previously, he suffered a penetrating ocular injury of his left eye and underwent primary closure. He had no underlying systemic disease. At his initial visit, the best corrected visual acuity of his left eye was 0.5. A whitish-gray mass was observed within the anterior chamber from 1 o'clock to 5 o'clock, obscuring the pupil. Anterior segment optical coherence tomography revealed a cystic mass touching the retrocorneal surface. No other lesions were seen on orbital imaging or ocular ultrasonography. Ultimately, it was diagnosed as an iris cyst that occurred secondary to ocular trauma. After needle aspiration and intracystic injection of 99% ethanol, the cyst collapsed fully. However, a cataract developed within a few months, and phacoemulsification and intraocular lens implantation were performed. Seven months after cyst aspiration, the uncorrected visual acuity of the left eye had recovered to 0.5. The cyst still adhered to the corneal endothelium, remaining in its collapsed state. The current corneal endothelial cell density is 871 cells/mm2.
Conclusions
A secondary iris cyst was diagnosed in a patient with a history of penetrating eye trauma and surgery. It was treated successfully with needle aspiration and intracystic alcohol injection.
10.Ten-year Trends in Infectious Keratitis in South Korea
Chanjoon PARK ; Hye Yeon YOON ; Young Sik YOO ; Hyun Soo LEE ; Hyung Bin HWANG ; Kyung Sun NA ; Yang Kyung CHO ; Eun Chul KIM ; So Hyang CHUNG ; Hyun Seung KIM ; Yong-Soo BYUN
Journal of the Korean Ophthalmological Society 2024;65(3):181-193
Purpose:
This study investigated the causative microorganisms, antibiotic susceptibility, and risk factors of infectious keratitis over the past 10 years.
Methods:
Data from patients with infectious keratitis who underwent microbial culture tests from 2012 to 2021, obtained from anonymized data systems, were analyzed. Microbial culture results and antibiotic susceptibility profiles were examined. A retrospective analysis of the medical records of patients with infectious keratitis during the same period was conducted to investigate the clinical characteristics and risk factors.
Results:
Data from 1,837 cases of infectious keratitis were extracted from anonymized records. The culture positive rate among patients was 46.0% (1,137/2,474), with coagulase-negative Staphylococcus (CoNS) being the most common causative organism (27.8%). Increased resistance to cefazolin and cefotaxime was observed in gram-negative bacteria, while there were no significant temporal changes in quinolone resistance in gram-positive or negative bacteria. A retrospective medical record analysis of 288 cases revealed that older patients, as well as those with an initial corrected visual acuity < 0.1, a history of ocular surgery, pre-existing ocular conditions, prior steroid eye drops, or glaucoma eye drops, had significantly higher rates of culture positivity. Multivariate analysis identified risk factors for severe keratitis requiring surgical intervention as a symptom-to-presentation period of 7 days or longer (p = 0.048) and pre-existing ocular conditions (p = 0.040).
Conclusions
CoNS was the most common microorganism causing infectious keratitis over the past decade. There has been an increase in resistance to cephalosporin antibiotics among gram-negative bacteria. Patients with pre-existing ocular conditions may require surgical intervention, so infectious keratitis in these patients requires greater attention.

Result Analysis
Print
Save