1.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Radiation-Induced Cavernous Malformation in the Cerebellum:Clinical Features of Two Cases
Hyoung Soo CHOI ; Chae-Yong KIM ; Byung Se CHOI ; Seung Hyuck JEON ; In Ah KIM ; Joo-Young KIM ; Kyu Sang LEE ; Gheeyoung CHOE
Brain Tumor Research and Treatment 2025;13(2):58-64
Radiation-induced cavernous malformations (RICMs) are rare but significant late complications of highdose radiation therapy, particularly in young survivors of brain tumors. This report presents two cases of RICMs following aggressive multimodal treatment, including surgery, chemotherapy, and radiation therapy. Case 1 was a 22-year-old male patient with medulloblastoma treated with craniospinal irradiation, tumor bed boost, and tandem autologous peripheral blood stem cell transplantation. Approximately 8 years after treatment completion, routine follow-up imaging revealed a small focal hemorrhage in the right cerebellum, consistent with an RICM. The lesion was asymptomatic and managed conservatively with regular imaging, showing spontaneous resolution over time, with a significant size reduction noted 9 years post-treatment. Case 2 describes a 32-year-old male with an intracranial germinoma treated with whole-ventricular irradiation. Three years after treatment, the patient developed a symptomatic hemorrhagic RICM near a pre-existing developmental venous anomaly. Surgical resection and Gamma Knife Surgery stabilized the lesion; however, residual symptoms, including tremors and gait disturbances, persisted, affecting the patient’s daily activities. These cases illustrate the diverse clinical courses of RICMs, ranging from spontaneous resolution to the necessity of surgical intervention, and emphasize the importance of long-term surveillance and tailored management strategies for late-onset complications.
4.Mycobacterium marinum flexor tenosynovitis of the hand diagnosed by tissue polymerase chain reaction: a case report
Jae Sang CHOI ; Dae Kyoung KIM ; Hyuck LEE ; Do Hyeong KIM
Archives of hand and microsurgery 2025;30(2):121-126
Mycobacterium marinum, a non-tuberculous mycobacterium, is commonly found in contaminated water or fish and can lead to deep infections of the hand. Identification of this bacterium is challenging, and traditional microbial culture and identification methods may result in delayed diagnosis and treatment. Tissue polymerase chain reaction is a diagnostic method that directly amplifies genus-specific primers from infected tissues obtained during surgery to identify mycobacterial species, and this approach provides results faster than conventional culture methods. We report a case of refractory infectious flexor tenosynovitis of the hand, in which the causative organism had not been identified for several months through smears, culture, and detection tests. Through extensive debridement and tissue polymerase chain reaction as an identification test, the patient was diagnosed with M. marinum infection and successfully treated.
5.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
6.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Mycobacterium marinum flexor tenosynovitis of the hand diagnosed by tissue polymerase chain reaction: a case report
Jae Sang CHOI ; Dae Kyoung KIM ; Hyuck LEE ; Do Hyeong KIM
Archives of hand and microsurgery 2025;30(2):121-126
Mycobacterium marinum, a non-tuberculous mycobacterium, is commonly found in contaminated water or fish and can lead to deep infections of the hand. Identification of this bacterium is challenging, and traditional microbial culture and identification methods may result in delayed diagnosis and treatment. Tissue polymerase chain reaction is a diagnostic method that directly amplifies genus-specific primers from infected tissues obtained during surgery to identify mycobacterial species, and this approach provides results faster than conventional culture methods. We report a case of refractory infectious flexor tenosynovitis of the hand, in which the causative organism had not been identified for several months through smears, culture, and detection tests. Through extensive debridement and tissue polymerase chain reaction as an identification test, the patient was diagnosed with M. marinum infection and successfully treated.
9.Radiation-Induced Cavernous Malformation in the Cerebellum:Clinical Features of Two Cases
Hyoung Soo CHOI ; Chae-Yong KIM ; Byung Se CHOI ; Seung Hyuck JEON ; In Ah KIM ; Joo-Young KIM ; Kyu Sang LEE ; Gheeyoung CHOE
Brain Tumor Research and Treatment 2025;13(2):58-64
Radiation-induced cavernous malformations (RICMs) are rare but significant late complications of highdose radiation therapy, particularly in young survivors of brain tumors. This report presents two cases of RICMs following aggressive multimodal treatment, including surgery, chemotherapy, and radiation therapy. Case 1 was a 22-year-old male patient with medulloblastoma treated with craniospinal irradiation, tumor bed boost, and tandem autologous peripheral blood stem cell transplantation. Approximately 8 years after treatment completion, routine follow-up imaging revealed a small focal hemorrhage in the right cerebellum, consistent with an RICM. The lesion was asymptomatic and managed conservatively with regular imaging, showing spontaneous resolution over time, with a significant size reduction noted 9 years post-treatment. Case 2 describes a 32-year-old male with an intracranial germinoma treated with whole-ventricular irradiation. Three years after treatment, the patient developed a symptomatic hemorrhagic RICM near a pre-existing developmental venous anomaly. Surgical resection and Gamma Knife Surgery stabilized the lesion; however, residual symptoms, including tremors and gait disturbances, persisted, affecting the patient’s daily activities. These cases illustrate the diverse clinical courses of RICMs, ranging from spontaneous resolution to the necessity of surgical intervention, and emphasize the importance of long-term surveillance and tailored management strategies for late-onset complications.
10.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.

Result Analysis
Print
Save
E-mail