1.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
		                        		
		                        			 Purpose:
		                        			This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices. 
		                        		
		                        			Methods:
		                        			I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations. 
		                        		
		                        			Results:
		                        			For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines. 
		                        		
		                        			Conclusions
		                        			These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices. 
		                        		
		                        		
		                        		
		                        	
2.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
		                        		
		                        			 Purpose:
		                        			This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices. 
		                        		
		                        			Methods:
		                        			I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations. 
		                        		
		                        			Results:
		                        			For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines. 
		                        		
		                        			Conclusions
		                        			These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices. 
		                        		
		                        		
		                        		
		                        	
3.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
		                        		
		                        			 Purpose:
		                        			This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices. 
		                        		
		                        			Methods:
		                        			I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations. 
		                        		
		                        			Results:
		                        			For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines. 
		                        		
		                        			Conclusions
		                        			These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices. 
		                        		
		                        		
		                        		
		                        	
4.Anatomical Variations Encountered during Adrenal Venous Sampling:A Report of Three Case Series and Review of Literature
Juyoung PAK ; Hyoung Nam LEE ; Myung Sub KIM ; Hyerim PARK
Journal of the Korean Society of Radiology 2024;85(2):456-462
		                        		
		                        			
		                        			 Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS. 
		                        		
		                        		
		                        		
		                        	
5.Anatomical Variations Encountered during Adrenal Venous Sampling:A Report of Three Case Series and Review of Literature
Juyoung PAK ; Hyoung Nam LEE ; Myung Sub KIM ; Hyerim PARK
Journal of the Korean Society of Radiology 2024;85(2):456-462
		                        		
		                        			
		                        			 Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS. 
		                        		
		                        		
		                        		
		                        	
6.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
		                        		
		                        			 Purpose:
		                        			This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices. 
		                        		
		                        			Methods:
		                        			I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations. 
		                        		
		                        			Results:
		                        			For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines. 
		                        		
		                        			Conclusions
		                        			These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices. 
		                        		
		                        		
		                        		
		                        	
7.Anatomical Variations Encountered during Adrenal Venous Sampling:A Report of Three Case Series and Review of Literature
Juyoung PAK ; Hyoung Nam LEE ; Myung Sub KIM ; Hyerim PARK
Journal of the Korean Society of Radiology 2024;85(2):456-462
		                        		
		                        			
		                        			 Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS. 
		                        		
		                        		
		                        		
		                        	
8.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
		                        		
		                        			 Purpose:
		                        			This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices. 
		                        		
		                        			Methods:
		                        			I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations. 
		                        		
		                        			Results:
		                        			For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines. 
		                        		
		                        			Conclusions
		                        			These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices. 
		                        		
		                        		
		                        		
		                        	
9.Corticosteroid outcome may be dependent of duration of use in severe COVID-19
Jin Hyoung KIM ; Yong Sub NA ; Song-I LEE ; Youn Young MOON ; Beom Seuk HWANG ; Ae-Rin BAEK ; Won-Young KIM ; Bo Young LEE ; Gil Myeong SEONG ; Moon Seong BAEK
The Korean Journal of Internal Medicine 2023;38(3):382-392
		                        		
		                        			 Background/Aims:
		                        			For patients hospitalized with coronavirus disease 2019 (COVID-19) who require supplemental oxygen, the evidence of the optimal duration of corticosteroid is limited. This study aims to identify whether long-term use of corticosteroids is associated with decreased mortality. 
		                        		
		                        			Methods:
		                        			Between February 10, 2020 and October 31, 2021, we analyzed consecutive hospitalized patients with COVID-19 with severe hypoxemia. The patients were divided into short-term (≤ 14 days) and long-term (> 14 days) corticosteroid users. The primary outcome was 60-day mortality. We performed propensity score (PS) analysis to mitigate the effect of confounders and conducted Kaplan-Meier curve analysis. 
		                        		
		                        			Results:
		                        			There were 141 (52%) short-term users and 130 (48%) long-term corticosteroid users. The median age was 68 years and the median PaO2/FiO2 at admission was 158. Of the patients, 40.6% required high-flow nasal cannula, 48.3% required mechanical ventilation, and 11.1% required extracorporeal membrane oxygenation. The overall 60-day mortality rate was 23.2%, and that of patients with hospital-acquired pneumonia (HAP) was 22.9%. The Kaplan-Meier curve for 60- day survival in the PS-matched cohort showed that corticosteroid for > 14 days was associated with decreased mortality (p = 0.0033). There were no significant differences in bacteremia and HAP between the groups. An adjusted odds ratio for the risk of 60-day mortality in short-term users was 5.53 (95% confidence interval, 1.90–18.26; p = 0.003). 
		                        		
		                        			Conclusions
		                        			For patients with severe COVID-19, long-term use of corticosteroids was associated with decreased mortality, with no increase in nosocomial complications. Corticosteroid use for > 14 days can benefit patients with severe COVID-19. 
		                        		
		                        		
		                        		
		                        	
10.Clinical outcomes of and risk factors for secondary infection in patients with severe COVID-19: a multicenter cohort study in South Korea
Yong Sub NA ; Ae-Rin BAEK ; Moon Seong BAEK ; Won-Young KIM ; Jin Hyoung KIM ; Bo young LEE ; Gil Myeong SEONG ; Song-I LEE
The Korean Journal of Internal Medicine 2023;38(1):68-79
		                        		
		                        			 Background/Aims:
		                        			Secondary infection with influenza virus occurs in critically ill patients and is associated with substantial morbidity and mortality; however, there is limited information about it in patients with severe coronavirus disease 2019 (COVID-19). Thus, we investigated the clinical outcomes of and risk factors for secondary infections in patients with severe COVID-19. 
		                        		
		                        			Methods:
		                        			This study included patients with severe COVID-19 who were admitted to seven hospitals in South Korea between February 2020 to February 2021. Multivariate logistic regression analyses were performed to assess factors associated with the risk of secondary infections. 
		                        		
		                        			Results:
		                        			Of the 348 included patients, 104 (29.9%) had at least one infection. There was no statistically significant difference in the 28-day mortality (17.3% vs. 12.3%, p = 0.214), but in-hospital mortality was higher (29.8% vs. 15.2%, p = 0.002) in the infected group than in the non-infected group. The risk factors for secondary infection were a high frailty scale (odds ratio [OR], 1.314; 95% confidence interval [CI], 1.123 to 1.538; p = 0.001), steroid use (OR, 3.110; 95% CI, 1.164 to 8.309; p = 0.024), and the application of mechanical ventilation (OR, 4.653; 95% CI, 2.533 to 8.547; p < 0.001). 
		                        		
		                        			Conclusions
		                        			In-hospital mortality was more than doubled in patients with severe COVID-19 and secondary infections. A high frailty scale, the use of steroids and application of mechanical ventilation were risk factors for secondary infection. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail