1.Impact of User’s Background Knowledge and Polyp Characteristics in Colonoscopy with Computer-Aided Detection
Jooyoung LEE ; Woo Sang CHO ; Byeong Soo KIM ; Dan YOON ; Jung KIM ; Ji Hyun SONG ; Sun Young YANG ; Seon Hee LIM ; Goh Eun CHUNG ; Ji Min CHOI ; Yoo Min HAN ; Hyoun-Joong KONG ; Jung Chan LEE ; Sungwan KIM ; Jung Ho BAE
Gut and Liver 2024;18(5):857-866
Background/Aims:
We investigated how interactions between humans and computer-aided detection (CADe) systems are influenced by the user’s experience and polyp characteristics.
Methods:
We developed a CADe system using YOLOv4, trained on 16,996 polyp images from 1,914 patients and 1,800 synthesized sessile serrated lesion (SSL) images. The performance of polyp detection with CADe assistance was evaluated using a computerized test module. Eighteen participants were grouped by colonoscopy experience (nurses, fellows, and experts). The value added by CADe based on the histopathology and detection difficulty of polyps were analyzed.
Results:
The area under the curve for CADe was 0.87 (95% confidence interval [CI], 0.83 to 0.91). CADe assistance increased overall polyp detection accuracy from 69.7% to 77.7% (odds ratio [OR], 1.88; 95% CI, 1.69 to 2.09). However, accuracy decreased when CADe inaccurately detected a polyp (OR, 0.72; 95% CI, 0.58 to 0.87). The impact of CADe assistance was most and least prominent in the nurses (OR, 1.97; 95% CI, 1.71 to 2.27) and the experts (OR, 1.42; 95% CI, 1.15 to 1.74), respectively. Participants demonstrated better sensitivity with CADe assistance, achieving 81.7% for adenomas and 92.4% for easy-to-detect polyps, surpassing the standalone CADe performance of 79.7% and 89.8%, respectively. For SSLs and difficult-to-detect polyps, participants' sensitivities with CADe assistance (66.5% and 71.5%, respectively) were below those of standalone CADe (81.1% and 74.4%). Compared to the other two groups (56.1% and 61.7%), the expert group showed sensitivity closest to that of standalone CADe in detecting SSLs (79.7% vs 81.1%, respectively).
Conclusions
CADe assistance boosts polyp detection significantly, but its effectiveness depends on the user’s experience, particularly for challenging lesions.
2.Virtual Design Considerations for Fixed Dental Prosthesis Including Axial Contour and Proximal Contact to Maintain Periodontal Health and Physiologic Function:A Narrative Review
Jun-Ho CHO ; Se-Hyoun KIM ; Jae-Bok LEE ; Hyung-In YOON
Journal of Korean Dental Science 2023;16(2):105-114
The axial contour and proximal contact of the prosthesis affect periodontal health, food impaction, and patient satisfaction. This narrative review provides a summary of articles regarding the axial contour and proximal contact of a fixed dental prosthesis on periodontal health and physiologic function. By acquiring a comprehensive understanding of the axial contour and proximal contact of teeth and prostheses, as well as their functional significance, the virtual design of fixed dental prosthesis can be optimized to maintain periodontal health and promote physiologic function effectively.
3.Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
Eun-Bin BAE ; Won-Tak CHO ; Do-Hyun PARK ; Su-Hyun HWANG ; So-Hyoun LEE ; Mi-Jung YUN ; Chang-Mo JEONG ; Jung-Bo HUH
The Journal of Advanced Prosthodontics 2023;15(3):155-170
PURPOSE:
. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems.
MATERIALS AND METHODS:
. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness.
RESULTS:
. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 μm but there was no statistically significant difference within the groups (P > .05).
CONCLUSION
. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 μm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown. [J Adv Prosthodont 2023;15:155-70]
4.Comparative effectiveness of JAK inhibitors and biologic disease-modifying antirheumatic drugs in patients with rheumatoid arthritis
Soo-Kyung CHO ; Hyoungyoung KIM ; Yeo-Jin SONG ; Hye Won KIM ; Eunwoo NAM ; Shin-Seok LEE ; Hye-Soon LEE ; Sung-Hoon PARK ; Yeon-Ah LEE ; Min-Chan PARK ; Sung Hae CHANG ; Hyoun-Ah KIM ; Seung-Ki KWOK ; Hae-Rim KIM ; Hyun-Sook KIM ; Bo Young YOON ; Wan-Sik UHM ; Yong-Gil KIM ; Jae Hoon KIM ; Jisoo LEE ; Jeongim CHOI ; Yoon-Kyoung SUNG
The Korean Journal of Internal Medicine 2023;38(4):546-556
Background/Aims:
We aimed to compare the effectiveness and safety of Janus kinase inhibitors (JAKi) vs. biologic disease- modifying antirheumatic drugs (bDMARD) in Korean patients with rheumatoid arthritis (RA) who had an inadequate response to conventional synthetic DMARDs.
Methods:
A quasi-experimental, multi-center, prospective, non-randomized study was conducted to compare response rates between JAKi and bDMARDs in patients with RA naïve to targeted therapy. An interim analysis was performed to estimate the proportion of patients achieving low disease activity (LDA) based on disease activity score (DAS)–28– erythroid sedimentation rate (ESR) (DAS28-ESR) at 24 weeks after treatment initiation and to evaluate the development of adverse events (AEs).
Results:
Among 506 patients enrolled from 17 institutions between April 2020 and August 2022, 346 (196 JAKi group and 150 bDMARD group) were included in the analysis. After 24 weeks of treatment, 49.0% of JAKi users and 48.7% of bDMARD users achieved LDA (p = 0.954). DAS28-ESR remission rates were also comparable between JAKi and bDMARD users (30.1% and 31.3%, respectively; p = 0.806). The frequency of AEs reported in the JAKi group was numerically higher than that in the bDMARDs group, but the frequencies of serious and severe AEs were comparable between the groups.
Conclusions
Our interim findings reveal JAKi have comparable effectiveness and safety to bDMARDs at 24 weeks after treatment initiation.
5.Acute Pulmonary Embolism and Chronic Thromboembolic Pulmonary Hypertension: Clinical and Serial CT Pulmonary Angiographic Features
Junho AN ; Yoojin NAM ; Hyoun CHO ; Jeonga CHANG ; Duk-Kyung KIM ; Kyung Soo LEE
Journal of Korean Medical Science 2022;37(10):e76-
In acute pulmonary embolism (PE), circulatory failure and systemic hypotension are important clinically for predicting poor prognosis. While pulmonary artery (PA) clot loads can be an indicator of the severity of current episode of PE or treatment effectiveness, they may not be used directly as an indicator of right ventricular (RV) failure or patient death. In other words, pulmonary vascular resistance or patient prognosis may not be determined only with mechanical obstruction of PAs and their branches by intravascular clot loads on computed tomography pulmonary angiography (CTPA), but determined also with vasoactive amines, reflex PA vasoconstriction, and systemic arterial hypoxemia occurring during acute PE. Large RV diameter with RV/left ventricle (LV) ratio > 1.0 and/or the presence of occlusive clot and pulmonary infarction on initial CTPA, and clinically determined high baseline PA pressure and RV dysfunction are independent predictors of oncoming chronic thromboembolic pulmonary hypertension (CTEPH). In this pictorial review, authors aimed to demonstrate clinical and serial CTPA features in patients with acute massive and submassive PE and to disclose acute CTPA and clinical features that are related to the prediction of oncoming CTEPH.
6.Usage of the Internet of Things in Medical Institutions and its Implications
Hyoun-Joong KONG ; Sunhee AN ; Sohye LEE ; Sujin CHO ; Jeeyoung HONG ; Sungwan KIM ; Saram LEE
Healthcare Informatics Research 2022;28(4):287-296
Objectives:
The purpose of this study was to explore new ways of creating value in the medical field and to derive recommendations for the role of medical institutions and the government.
Methods:
In this paper, based on expert discussion, we classified Internet of Things (IoT) technologies into four categories according to the type of information they collect (location, environmental parameters, energy consumption, and biometrics), and investigated examples of application.
Results:
Biometric IoT diagnoses diseases accurately and offers appropriate and effective treatment. Environmental parameter measurement plays an important role in accurately identifying and controlling environmental factors that could be harmful to patients. The use of energy measurement and location tracking technology enabled optimal allocation of limited hospital resources and increased the efficiency of energy consumption. The resulting economic value has returned to patients, improving hospitals’ cost-effectiveness.
Conclusions
Introducing IoT-based technology to clinical sites, including medical institutions, will enhance the quality of medical services, increase patient safety, improve management efficiency, and promote patient-centered medical services. Moreover, the IoT is expected to play an active role in the five major tasks of facility hygiene in medical fields, which are all required to deal with the COVID-19 pandemic: social distancing, contact tracking, bed occupancy control, and air quality management. Ultimately, the IoT is expected to serve as a key element for hospitals to perform their original functions more effectively. Continuing investments, deregulation policies, information protection, and IT standardization activities should be carried out more actively for the IoT to fulfill its expectations.
7.Review of Smart Hospital Services in Real Healthcare Environments
Hyuktae KWON ; Sunhee AN ; Ho-Young LEE ; Won Chul CHA ; Sungwan KIM ; Minwoo CHO ; Hyoun-Joong KONG
Healthcare Informatics Research 2022;28(1):3-15
Objectives:
Smart hospitals involve the application of recent information and communications technology (ICT) innovations to medical services; however, the concept of a smart hospital has not been rigorously defined. In this study, we aimed to derive the definition and service types of smart hospitals and investigate cases of each type.
Methods:
A literature review was conducted regarding the background and technical characteristics of smart hospitals. On this basis, we conducted a focus group interview with experts in hospital information systems, and ultimately derived eight smart hospital service types.
Results:
Smart hospital services can be classified into the following types: services based on location recognition and tracking technology that measures and monitors the location information of an object based on short-range communication technology; high-speed communication network-based services based on new wireless communication technology; Internet of Things-based services that connect objects embedded with sensors and communication functions to the internet; mobile health services such as mobile phones, tablets, and wearables; artificial intelligence-based services for the diagnosis and prediction of diseases; robot services provided on behalf of humans in various medical fields; extended reality services that apply hyper-realistic immersive technology to medical practice; and telehealth using ICT.
Conclusions
Smart hospitals can influence health and medical policies and create new medical value by defining and quantitatively measuring detailed indicators based on data collected from existing hospitals. Simultaneously, appropriate government incentives, consolidated interdisciplinary research, and active participation by industry are required to foster and facilitate smart hospitals.
8.Improved Biocompatibility of Intra-Arterial Poly-L-Lactic Acid Stent by Tantalum Ion Implantation : 3-Month Results in a Swine Model
Kangmin KIM ; Suhyung PARK ; Jeong Hwan PARK ; Won-Sang CHO ; Hyoun-Ee KIM ; Sung-Mi LEE ; Jeong Eun KIM ; Hyun-Seung KANG ; Tae-Sik JANG
Journal of Korean Neurosurgical Society 2021;64(6):853-863
Objective:
: Biodegradable poly-L-lactic acid (PLLA) with a highly biocompatible surface via tantalum (Ta) ion implantation can be an innovative solution for the problems associated with current biodegradable stents. The purpose of this study is to develop a Ta-implanted PLLA stent for clinical use and to investigate its biological performance capabilities.
Methods:
: A series of in vitro and in vivo tests were used to assess the biological performance of bare and Ta-implanted PLLA stents. The re-endothelialization ability and thrombogenicity were examined through in vitro endothelial cell and platelet adhesion tests. An in vivo swine model was used to evaluate the effects of Ta ion implantation on subacute restenosis and thrombosis. Angiographic and histologic evaluations were conducted at one, two and three months post-treatment.
Results:
: The Ta-implanted PLLA stent was successfully fabricated, exhibiting a smooth surface morphology and modified layer integration. After Ta ion implantation, the surface properties were more favorable for rapid endothelialization and for less platelet attachment compared to the bare PLLA stent. In an in vivo animal test, follow-up angiography showed no evidence of in-stent stenosis in either group. In a microscopic histologic examination, luminal thrombus formation was significantly suppressed in the Ta-implanted PLLA stent group according to the 2-month follow-up assessment (21.2% vs. 63.9%, p=0.005). Cells positive for CD 68, a marker for the monocyte lineage, were less frequently identified around the Ta-implanted PLLA stent in the 1-month follow-up assessments.
Conclusion
: The use of a Ta-implanted PLLA stent appears to promote re-endothelialization and anti-thrombogenicity.
9.Bioinformatics services for analyzing massive genomic datasets
Gunhwan KO ; Pan-Gyu KIM ; Youngbum CHO ; Seongmun JEONG ; Jae-Yoon KIM ; Kyoung Hyoun KIM ; Ho-Yeon LEE ; Jiyeon HAN ; Namhee YU ; Seokjin HAM ; Insoon JANG ; Byunghee KANG ; Sunguk SHIN ; Lian KIM ; Seung-Won LEE ; Dougu NAM ; Jihyun F. KIM ; Namshin KIM ; Seon-Young KIM ; Sanghyuk LEE ; Tae-Young ROH ; Byungwook LEE
Genomics & Informatics 2020;18(1):e8-
The explosive growth of next-generation sequencing data has resulted in ultra-large-scale datasets and ensuing computational problems. In Korea, the amount of genomic data has been increasing rapidly in the recent years. Leveraging these big data requires researchers to use large-scale computational resources and analysis pipelines. A promising solution for addressing this computational challenge is cloud computing, where CPUs, memory, storage, and programs are accessible in the form of virtual machines. Here, we present a cloud computing-based system, Bio-Express, that provides user-friendly, cost-effective analysis of massive genomic datasets. Bio-Express is loaded with predefined multi-omics data analysis pipelines, which are divided into genome, transcriptome, epigenome, and metagenome pipelines. Users can employ predefined pipelines or create a new pipeline for analyzing their own omics data. We also developed several web-based services for facilitating downstream analysis of genome data. Bio-Express web service is freely available at https://www.bioexpress.re.kr/.
10.Bioinformatics services for analyzing massive genomic datasets
Gunhwan KO ; Pan-Gyu KIM ; Youngbum CHO ; Seongmun JEONG ; Jae-Yoon KIM ; Kyoung Hyoun KIM ; Ho-Yeon LEE ; Jiyeon HAN ; Namhee YU ; Seokjin HAM ; Insoon JANG ; Byunghee KANG ; Sunguk SHIN ; Lian KIM ; Seung-Won LEE ; Dougu NAM ; Jihyun F. KIM ; Namshin KIM ; Seon-Young KIM ; Sanghyuk LEE ; Tae-Young ROH ; Byungwook LEE
Genomics & Informatics 2020;18(1):e8-
The explosive growth of next-generation sequencing data has resulted in ultra-large-scale datasets and ensuing computational problems. In Korea, the amount of genomic data has been increasing rapidly in the recent years. Leveraging these big data requires researchers to use large-scale computational resources and analysis pipelines. A promising solution for addressing this computational challenge is cloud computing, where CPUs, memory, storage, and programs are accessible in the form of virtual machines. Here, we present a cloud computing-based system, Bio-Express, that provides user-friendly, cost-effective analysis of massive genomic datasets. Bio-Express is loaded with predefined multi-omics data analysis pipelines, which are divided into genome, transcriptome, epigenome, and metagenome pipelines. Users can employ predefined pipelines or create a new pipeline for analyzing their own omics data. We also developed several web-based services for facilitating downstream analysis of genome data. Bio-Express web service is freely available at https://www.bioexpress.re.kr/.

Result Analysis
Print
Save
E-mail