1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Comparative Study on the Immunogenicity of COVID-19 mRNA Vaccines in Patients Receiving Adjuvant and Palliative Chemotherapy
Hyun-Woo CHOI ; Younggon JUNG ; Uh Jin KIM ; Sang-Cheol LEE ; Jung Hye KWON ; Hyeonjong KIM ; Sarah KIM ; Yoonjung LEE ; Hyun-Jung SHIM ; Sang-Hee CHO ; Ik-Joo CHUNG ; Eu Chang HWANG ; Seung Ji KANG ; Woo Kyun BAE ; Seung-Jung KEE
Chonnam Medical Journal 2024;60(1):69-77
This study was conducted to investigate potential differences in vaccine efficacy between patients undergoing palliative chemotherapy and receiving adjuvant chemotherapy. Additionally, the study proved the influence of vaccination timing on vaccine efficacy during active chemotherapy. Anti-receptor-binding domain (RBD) IgG binding antibody assays and surrogate neutralizing antibody assays were performed after BNT162b2 or mRNA-1273 vaccination in 45 solid cancer patients (23 adjuvant and 22 palliative chemotherapy) and in 24 healthy controls before vaccination (baseline), at every two to four weeks after the first (post-dose 1) and the second vaccination (post-dose 2). The levels of anti-RBD IgG and neutralizing antibodies increased significantly from baseline through post-dose 1 to post-dose 2 in all three groups. At the post-dose 1, the anti-RBD IgG and neutralizing antibody levels were significantly lower in cancer patients than in healthy controls. However, by post-dose 2, the seropositivity of anti-RBD IgG and neutralizing antibodies uniformly reached 100% across all groups, with no significant disparity in antibody levels among the three groups. Moreover, the antibody titers were not significantly different between patients with a vaccine and chemotherapy interval of more than 14 days or those with less than 14 days. This study demonstrated that after second doses of mRNA COVID-19 vaccines, humoral immune responses in patients receiving chemotherapy were comparable to those of healthy controls, regardless of whether the purpose of the anti-cancer treatment was palliative or adjuvant. Furthermore, the timing of vaccination did not affect the level of humoral immunity after the second vaccination.
7.Accuracy of Bite Registration Using Intraoral Scanner Based on Data Trimming Strategy for Fremitus Teeth
Yuwon JEONG ; June-Sung SHIM ; Jee-Hwan KIM ; Jong-Eun KIM ; Hyeonjong LEE
Journal of Korean Dental Science 2022;15(1):61-67
Purpose:
This study aimed to evaluate the accuracy of bite registration using intraoral scanner based on data trimming strategy for fremitus teeth.
Materials and Methods:
A reference model was designed by Medit Model Builder software (MEDIT Corp., Seoul). Tooth number 24 and 25 were separated as dies and tooth number 26 was prepared for full-coverage crown. Those were printed using a 3D printer (NextDent 5100). The scanning procedure was performed by a single trained operator with one intraoral scanner (i700; MEDIT Corp.). The scanning groups were divided as follows: group 1 (G1), no fremitus; group 2 (G2), 0.5 mm buccal fremitus in the maxillary left first and second premolar; and group 3 (G3), 1.5 mm buccal fremitus in the maxillary left first and second premolar. Each group was scanned 10 times and were analyzed using the reference model data. Surface-based occlusal clearance was analyzed at the prepared tooth to evaluate accuracy.Result: Mean values of control group (G1) were 1.587±0.021 mm. G2 showed similar values to those from the control group (1.580±0.024 mm before trimming strategy and 1.588±0.052 mm after trimming strategy). G3 showed significantly greater values (1.627±0.025 mm before trimming strategy and 1.590±0.024 mm after trimming strategy) and the differences were found between trimming strategy (P=0.004).
Conclusion
Bite trimming strategy for fremitus teeth is a reliable technique to reduce inaccuracies caused by the mobility at maximum intercuspation.
8.Larger Remaining Stomach Volume Is Associated With Better Nutrition and Muscle Preservation in Patients With Gastric Cancer Receiving Distal Gastrectomy With Gastroduodenostomy
Amy KIM ; Jung-Bok LEE ; Yousun KO ; Taeyong PARK ; Hyeonjong JO ; Jin Kyoo JANG ; Kyoungsuk LEE ; Kyung Won KIM ; In-Seob LEE
Journal of Gastric Cancer 2022;22(2):145-155
Purpose:
Weight loss and deterioration in body composition are observed in patients with gastric cancer (GC) following gastrectomy. This study aimed to investigate the impact of residual stomach volume (RSV) on the nutritional status and body composition of patients with GC treated with distal gastrectomy.
Materials and Methods:
In total, 227 patients who underwent minimally invasive distal gastrectomy with Billroth 1 anastomosis for stage I GC between February 2015 and May 2018 were enrolled. Clinicodemographic and laboratory data were collected from the GC registry. The RSV, abdominal muscle area, and subcutaneous/visceral fat areas were measured using computed tomography data.
Results:
A larger RSV was associated with a lower decrease in the nutritional risk index (P=0.004) and hemoglobin level (P=0.003) during the first 3 months after surgery, and better recovery at 12 months. A larger RSV demonstrated an advantage in the preservation of abdominal muscle area (P=0.02) and visceral fat (P=0.04) after surgery, as well as less reduction in weight (P=0.02) and body mass index (P=0.03).
Conclusions
Larger RSV was associated with improved nutritional status and better preservation of muscle and fat after distal gastrectomy.
9.Implant-assisted removable partial denture using digital guide surgery in partially edentulous mandible: A case report
Taehoon KIM ; Chang-Mo JEONG ; Mi-Jung YUN ; So-Hyoun LEE ; Hyeonjong LEE ; Jung-Bo HUH
The Journal of Korean Academy of Prosthodontics 2021;59(1):88-96
Fixed implant prostheses or removable partial dentures are common treatment for partially dentulous patients. Recently, an implant-assisted removable partial denture (IARPD) has been introduced and is widely used. In the case of removable partial dentures using implant attachment and surveyed fixed prostheses, the consideration about parallelism of insertion path between implants and surveyed fixed prostheses is an important factor for success of IARPDs. In this case, she complained of discomfort while using the mandibular removable partial denture. Thus, an IARPD using implant surveyed fixed prostheses was fabricated.Thereafter, more implants were placed by a digital guide surgery to have the same insertion path as the existing surveyed fixed prostheses. Locator attachments were installed to the left and right premolar implants, and the left molar was able to obtain support of the removable partial denture with healing abutment. The clinical results were satisfactory on the aspect of aesthetic and masticatory function.
10.Full mouth rehabilitation with vertical dimension increase in patient with severely worn out dentition: A case report
Dae-Sung KIM ; Chang-Mo JEONG ; Mi-Jung YUN ; Jung-Bo HUH ; Hyeonjong LEE ; So-Hyoun LEE
The Journal of Korean Academy of Prosthodontics 2021;59(2):210-219
Excessive teeth wear can lead to reduced chewing efficiency, occlusal plane collapse, and facial changes. Full mouth rehabilitation with a change in vertical dimension may cause pain in the temporomandibular joint, masticatory muscle and teeth, so an accurate diagnosis and treatment plan is required. In this case, a 69-year-old man had excessive teeth wear with a loss of posterior support. We evaluated the degree of adaptation to the increased vertical dimension with the removable occlusal splint and provisional restoration. We report this case because the treatment result has been functionally and aesthetically satisfactory by providing stable anterior guidance, proper posterior teeth disclusion, and even contact of all teeth in centric occlusion.

Result Analysis
Print
Save
E-mail