1.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
		                        		
		                        			 Purpose:
		                        			We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery. 
		                        		
		                        			Methods:
		                        			This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin. 
		                        		
		                        			Results:
		                        			In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed. 
		                        		
		                        			Conclusion
		                        			Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery. 
		                        		
		                        		
		                        		
		                        	
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
4.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
		                        		
		                        			 Purpose:
		                        			We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery. 
		                        		
		                        			Methods:
		                        			This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin. 
		                        		
		                        			Results:
		                        			In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed. 
		                        		
		                        			Conclusion
		                        			Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery. 
		                        		
		                        		
		                        		
		                        	
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
6.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
		                        		
		                        			 Purpose:
		                        			We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery. 
		                        		
		                        			Methods:
		                        			This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin. 
		                        		
		                        			Results:
		                        			In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed. 
		                        		
		                        			Conclusion
		                        			Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery. 
		                        		
		                        		
		                        		
		                        	
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
8.Efficacy and Safety of Metformin and Atorvastatin Combination Therapy vs. Monotherapy with Either Drug in Type 2 Diabetes Mellitus and Dyslipidemia Patients (ATOMIC): Double-Blinded Randomized Controlled Trial
Jie-Eun LEE ; Seung Hee YU ; Sung Rae KIM ; Kyu Jeung AHN ; Kee-Ho SONG ; In-Kyu LEE ; Ho-Sang SHON ; In Joo KIM ; Soo LIM ; Doo-Man KIM ; Choon Hee CHUNG ; Won-Young LEE ; Soon Hee LEE ; Dong Joon KIM ; Sung-Rae CHO ; Chang Hee JUNG ; Hyun Jeong JEON ; Seung-Hwan LEE ; Keun-Young PARK ; Sang Youl RHEE ; Sin Gon KIM ; Seok O PARK ; Dae Jung KIM ; Byung Joon KIM ; Sang Ah LEE ; Yong-Hyun KIM ; Kyung-Soo KIM ; Ji A SEO ; Il Seong NAM-GOONG ; Chang Won LEE ; Duk Kyu KIM ; Sang Wook KIM ; Chung Gu CHO ; Jung Han KIM ; Yeo-Joo KIM ; Jae-Myung YOO ; Kyung Wan MIN ; Moon-Kyu LEE
Diabetes & Metabolism Journal 2024;48(4):730-739
		                        		
		                        			 Background:
		                        			It is well known that a large number of patients with diabetes also have dyslipidemia, which significantly increases the risk of cardiovascular disease (CVD). This study aimed to evaluate the efficacy and safety of combination drugs consisting of metformin and atorvastatin, widely used as therapeutic agents for diabetes and dyslipidemia. 
		                        		
		                        			Methods:
		                        			This randomized, double-blind, placebo-controlled, parallel-group and phase III multicenter study included adults with glycosylated hemoglobin (HbA1c) levels >7.0% and <10.0%, low-density lipoprotein cholesterol (LDL-C) >100 and <250 mg/dL. One hundred eighty-five eligible subjects were randomized to the combination group (metformin+atorvastatin), metformin group (metformin+atorvastatin placebo), and atorvastatin group (atorvastatin+metformin placebo). The primary efficacy endpoints were the percent changes in HbA1c and LDL-C levels from baseline at the end of the treatment. 
		                        		
		                        			Results:
		                        			After 16 weeks of treatment compared to baseline, HbA1c showed a significant difference of 0.94% compared to the atorvastatin group in the combination group (0.35% vs. −0.58%, respectively; P<0.0001), whereas the proportion of patients with increased HbA1c was also 62% and 15%, respectively, showing a significant difference (P<0.001). The combination group also showed a significant decrease in LDL-C levels compared to the metformin group (−55.20% vs. −7.69%, P<0.001) without previously unknown adverse drug events. 
		                        		
		                        			Conclusion
		                        			The addition of atorvastatin to metformin improved HbA1c and LDL-C levels to a significant extent compared to metformin or atorvastatin alone in diabetes and dyslipidemia patients. This study also suggested metformin’s preventive effect on the glucose-elevating potential of atorvastatin in patients with type 2 diabetes mellitus and dyslipidemia, insufficiently controlled with exercise and diet. Metformin and atorvastatin combination might be an effective treatment in reducing the CVD risk in patients with both diabetes and dyslipidemia because of its lowering effect on LDL-C and glucose. 
		                        		
		                        		
		                        		
		                        	
9.Efficacy and Safety of Lurasidone vs. Quetiapine XR in Acutely Psychotic Patients With Schizophrenia in Korea: A Randomized, Double-Blind, Active-Controlled Trial
Se Hyun KIM ; Do-Un JUNG ; Do Hoon KIM ; Jung Sik LEE ; Kyoung-Uk LEE ; Seunghee WON ; Bong Ju LEE ; Sung-Gon KIM ; Sungwon ROH ; Jong-Ik PARK ; Minah KIM ; Sung Won JUNG ; Hong Seok OH ; Han-yong JUNG ; Sang Hoon KIM ; Hyun Seung CHEE ; Jong-Woo PAIK ; Kyu Young LEE ; Soo In KIM ; Seung-Hwan LEE ; Eun-Jin CHEON ; Hye-Geum KIM ; Heon-Jeong LEE ; In Won CHUNG ; Joonho CHOI ; Min-Hyuk KIM ; Seong-Jin CHO ; HyunChul YOUN ; Jhin-Goo CHANG ; Hoo Rim SONG ; Euitae KIM ; Won-Hyoung KIM ; Chul Eung KIM ; Doo-Heum PARK ; Byung-Ook LEE ; Jungsun LEE ; Seung-Yup LEE ; Nuree KANG ; Hee Yeon JUNG
Psychiatry Investigation 2024;21(7):762-771
		                        		
		                        			 Objective:
		                        			This study was performed to evaluate the efficacy and safety of lurasidone (160 mg/day) compared to quetiapine XR (QXR; 600 mg/day) in the treatment of acutely psychotic patients with schizophrenia. 
		                        		
		                        			Methods:
		                        			Patients were randomly assigned to 6 weeks of double-blind treatment with lurasidone 160 mg/day (n=105) or QXR 600 mg/day (n=105). Primary efficacy measure was the change from baseline to week 6 in Positive and Negative Syndrome Scale (PANSS) total score and Clinical Global Impressions severity (CGI-S) score. Adverse events, body measurements, and laboratory parameters were assessed. 
		                        		
		                        			Results:
		                        			Lurasidone demonstrated non-inferiority to QXR on the PANSS total score. Adjusted mean±standard error change at week 6 on the PANSS total score was -26.42±2.02 and -27.33±2.01 in the lurasidone and QXR group, respectively. The mean difference score was -0.91 (95% confidence interval -6.35–4.53). The lurasidone group showed a greater reduction in PANSS total and negative subscale on week 1 and a greater reduction in end-point CGI-S score compared to the QXR group. Body weight, body mass index, and waist circumference in the lurasidone group were reduced, with significantly lower mean change compared to QXR. Endpoint changes in glucose, cholesterol, triglycerides, and low-density lipoprotein levels were also significantly lower. The most common adverse drug reactions with lurasidone were akathisia and nausea. 
		                        		
		                        			Conclusion
		                        			Lurasidone 160 mg/day was found to be non-inferior to QXR 600 mg/day in the treatment of schizophrenia with comparable efficacy and tolerability. Adverse effects of lurasidone were generally tolerable, and beneficial effects on metabolic parameters can be expected. 
		                        		
		                        		
		                        		
		                        	
10.A large and pedunculated inflammatory pseudotumor with pseudosarcomatous change of the cecum mimicking a malignant polyp: a case report and literature review
Jong Suk OH ; Hyung Wook KIM ; Su Bum PARK ; Dae Hwan KANG ; Cheol Woong CHOI ; Su Jin KIM ; Hyeong Seok NAM ; Dae Gon RYU
Clinical Endoscopy 2023;56(1):119-124
		                        		
		                        			
		                        			 Inflammatory pseudotumor (IPT) is a rare benign tumor of unknown etiology that can occur in almost any organ system. It has neoplastic features such as local recurrence, invasive growth, and vascular invasion, leading to the possibility of malignant sarcomatous changes. The clinical presentations of colonic IPT may include abdominal pain, anemia, a palpable mass, and intestinal obstruction. A few cases of colonic IPT have been reported, but colonic IPT with pedunculated morphology is very rare. Furthermore, since it can mimic malignant polyps, understanding the endoscopic findings of colonic IPT is important for proper treatment. Herein, we present a case of colonic IPT with pseudosarcomatous changes, presenting as a large polyp, mimicking a malignant polyp in the cecum, along with a literature review. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail