1.Low-air-pressure clean room system: A flexible, high-quality model for assisted reproduction laboratories
Minh Tam LE ; Trung Van NGUYEN ; Thai Thanh Thi NGUYEN ; Hong Nhan Thi DANG ; Quoc Huy Vu NGUYEN
Clinical and Experimental Reproductive Medicine 2025;52(1):56-64
		                        		
		                        			 Objective:
		                        			This study aimed to develop a configurable clean room paradigm with low air pressure for assisted reproductive technology (ART) clinics and demonstrate the concept’s efficacy using in vitro fertilization (IVF) treatment. 
		                        		
		                        			Methods:
		                        			A high-standard clean room system with positive pressure (13 Pa) was built using accessible materials and equipment for ART laboratories. Methods for controlling and evaluating the clean room’s characteristics were developed and implemented for quality assessment and calibration to maximize efficiency. The feasibility of the flexible clean room concept was assessed by analyzing the key performance indicators of embryo culture and IVF treatment. 
		                        		
		                        			Results:
		                        			After 3 weeks of testing, the concentration of particles ≥0.5 μm was 6.04 times lower than the International Organization for Standardization (ISO) class 5 standard (3,520 particles/m3) in the IVF laboratory. Air pressure, noise, temperature, and humidity were controlled stably and appropriately. Five days after installation and handover, the volatile organic compound concentration dropped to 0.00 ppm. With blastocysts and a respectable blastocyst rate, embryonic culture with female patients younger than 40 matched the criteria (63.5% and 38.9%, respectively). After vitrified blastocysts were transferred, the pregnancy and implantation rates were 58.5% and 36.2%, respectively, demonstrating a high degree of treatment success. 
		                        		
		                        			Conclusion
		                        			Our customizable, high-quality, low-air-pressure clean room model can be implemented to achieve positive outcomes for infertility treatment. 
		                        		
		                        		
		                        		
		                        	
2.Endoscopic vacuum therapy for gastrointestinal transmural defects: a literature review
Tan Minh LE ; Van Huy TRAN ; Kyu Sung CHUNG ; Seong Woo JEON
Clinical Endoscopy 2025;58(2):181-190
		                        		
		                        			
		                        			 Endoscopic vacuum therapy (EVT) has emerged as a transformative approach for managing gastrointestinal (GI) transmural defects, offering a less invasive and more promising alternative to surgery. Initially developed to address anastomotic leaks after rectal surgery, the application of EVT has expanded to include other locations within the GI tract. This review investigated the principles, indications, procedures, outcomes, challenges, and future perspectives of EVT for the management of GI transmural defects. In conclusion, EVT has demonstrated favorable outcomes in GI defect closure, with reduced complications, shortened hospital stay, and decreased morbidity rates as compared with conventional treatments. Although EVT faces challenges in some specific anatomical locations and in managing severe complications such as major bleeding, ongoing advancements in technology and standardization efforts offer promise for broader indications and better outcomes. Future perspectives include exploring novel EVT devices, refining patient selection criteria and pre-emptive applications, and standardizing procedural protocols. 
		                        		
		                        		
		                        		
		                        	
3.Low-air-pressure clean room system: A flexible, high-quality model for assisted reproduction laboratories
Minh Tam LE ; Trung Van NGUYEN ; Thai Thanh Thi NGUYEN ; Hong Nhan Thi DANG ; Quoc Huy Vu NGUYEN
Clinical and Experimental Reproductive Medicine 2025;52(1):56-64
		                        		
		                        			 Objective:
		                        			This study aimed to develop a configurable clean room paradigm with low air pressure for assisted reproductive technology (ART) clinics and demonstrate the concept’s efficacy using in vitro fertilization (IVF) treatment. 
		                        		
		                        			Methods:
		                        			A high-standard clean room system with positive pressure (13 Pa) was built using accessible materials and equipment for ART laboratories. Methods for controlling and evaluating the clean room’s characteristics were developed and implemented for quality assessment and calibration to maximize efficiency. The feasibility of the flexible clean room concept was assessed by analyzing the key performance indicators of embryo culture and IVF treatment. 
		                        		
		                        			Results:
		                        			After 3 weeks of testing, the concentration of particles ≥0.5 μm was 6.04 times lower than the International Organization for Standardization (ISO) class 5 standard (3,520 particles/m3) in the IVF laboratory. Air pressure, noise, temperature, and humidity were controlled stably and appropriately. Five days after installation and handover, the volatile organic compound concentration dropped to 0.00 ppm. With blastocysts and a respectable blastocyst rate, embryonic culture with female patients younger than 40 matched the criteria (63.5% and 38.9%, respectively). After vitrified blastocysts were transferred, the pregnancy and implantation rates were 58.5% and 36.2%, respectively, demonstrating a high degree of treatment success. 
		                        		
		                        			Conclusion
		                        			Our customizable, high-quality, low-air-pressure clean room model can be implemented to achieve positive outcomes for infertility treatment. 
		                        		
		                        		
		                        		
		                        	
4.Endoscopic vacuum therapy for gastrointestinal transmural defects: a literature review
Tan Minh LE ; Van Huy TRAN ; Kyu Sung CHUNG ; Seong Woo JEON
Clinical Endoscopy 2025;58(2):181-190
		                        		
		                        			
		                        			 Endoscopic vacuum therapy (EVT) has emerged as a transformative approach for managing gastrointestinal (GI) transmural defects, offering a less invasive and more promising alternative to surgery. Initially developed to address anastomotic leaks after rectal surgery, the application of EVT has expanded to include other locations within the GI tract. This review investigated the principles, indications, procedures, outcomes, challenges, and future perspectives of EVT for the management of GI transmural defects. In conclusion, EVT has demonstrated favorable outcomes in GI defect closure, with reduced complications, shortened hospital stay, and decreased morbidity rates as compared with conventional treatments. Although EVT faces challenges in some specific anatomical locations and in managing severe complications such as major bleeding, ongoing advancements in technology and standardization efforts offer promise for broader indications and better outcomes. Future perspectives include exploring novel EVT devices, refining patient selection criteria and pre-emptive applications, and standardizing procedural protocols. 
		                        		
		                        		
		                        		
		                        	
5.Low-air-pressure clean room system: A flexible, high-quality model for assisted reproduction laboratories
Minh Tam LE ; Trung Van NGUYEN ; Thai Thanh Thi NGUYEN ; Hong Nhan Thi DANG ; Quoc Huy Vu NGUYEN
Clinical and Experimental Reproductive Medicine 2025;52(1):56-64
		                        		
		                        			 Objective:
		                        			This study aimed to develop a configurable clean room paradigm with low air pressure for assisted reproductive technology (ART) clinics and demonstrate the concept’s efficacy using in vitro fertilization (IVF) treatment. 
		                        		
		                        			Methods:
		                        			A high-standard clean room system with positive pressure (13 Pa) was built using accessible materials and equipment for ART laboratories. Methods for controlling and evaluating the clean room’s characteristics were developed and implemented for quality assessment and calibration to maximize efficiency. The feasibility of the flexible clean room concept was assessed by analyzing the key performance indicators of embryo culture and IVF treatment. 
		                        		
		                        			Results:
		                        			After 3 weeks of testing, the concentration of particles ≥0.5 μm was 6.04 times lower than the International Organization for Standardization (ISO) class 5 standard (3,520 particles/m3) in the IVF laboratory. Air pressure, noise, temperature, and humidity were controlled stably and appropriately. Five days after installation and handover, the volatile organic compound concentration dropped to 0.00 ppm. With blastocysts and a respectable blastocyst rate, embryonic culture with female patients younger than 40 matched the criteria (63.5% and 38.9%, respectively). After vitrified blastocysts were transferred, the pregnancy and implantation rates were 58.5% and 36.2%, respectively, demonstrating a high degree of treatment success. 
		                        		
		                        			Conclusion
		                        			Our customizable, high-quality, low-air-pressure clean room model can be implemented to achieve positive outcomes for infertility treatment. 
		                        		
		                        		
		                        		
		                        	
6.Endoscopic vacuum therapy for gastrointestinal transmural defects: a literature review
Tan Minh LE ; Van Huy TRAN ; Kyu Sung CHUNG ; Seong Woo JEON
Clinical Endoscopy 2025;58(2):181-190
		                        		
		                        			
		                        			 Endoscopic vacuum therapy (EVT) has emerged as a transformative approach for managing gastrointestinal (GI) transmural defects, offering a less invasive and more promising alternative to surgery. Initially developed to address anastomotic leaks after rectal surgery, the application of EVT has expanded to include other locations within the GI tract. This review investigated the principles, indications, procedures, outcomes, challenges, and future perspectives of EVT for the management of GI transmural defects. In conclusion, EVT has demonstrated favorable outcomes in GI defect closure, with reduced complications, shortened hospital stay, and decreased morbidity rates as compared with conventional treatments. Although EVT faces challenges in some specific anatomical locations and in managing severe complications such as major bleeding, ongoing advancements in technology and standardization efforts offer promise for broader indications and better outcomes. Future perspectives include exploring novel EVT devices, refining patient selection criteria and pre-emptive applications, and standardizing procedural protocols. 
		                        		
		                        		
		                        		
		                        	
7.Active case finding to detect symptomatic and subclinical pulmonary tuberculosis disease: implementation of computer-aided detection for chest radiography in Viet Nam
Anh L Innes ; Andres Martinez ; Gia Linh Hoang ; Thi Bich Phuong Nguyen ; Viet Hien Vu ; Tuan Ho Thanh Luu ; Thi Thu Trang Le ; Victoria Lebrun ; Van Chinh Trieu ; Nghi Do Bao Tran ; Nhi Dinh ; Huy Minh Pham ; Van Luong Dinh ; Binh Hoa Nguyen ; Thi Thanh Huyen Truong ; Van Cu Nguyen ; Viet Nhung Nguyen ; Thu Hien Mai
Western Pacific Surveillance and Response 2024;15(4):14-25
		                        		
		                        			
		                        			Objective: In Viet Nam, tuberculosis (TB) prevalence surveys revealed that approximately 98% of individuals with pulmonary TB have TB-presumptive abnormalities on chest radiographs, while 32% have no TB symptoms. This prompted the adoption of the “Double X” strategy, which combines chest radiographs and computer-aided detection with GeneXpert testing to screen for and diagnose TB among vulnerable populations. The aim of this study was to describe demographic, clinical and radiographic characteristics of symptomatic and asymptomatic Double X participants and to assess multilabel radiographic abnormalities on chest radiographs, interpreted by computer-aided detection software, as a possible tool for detecting TB-presumptive abnormalities, particularly for subclinical TB.
Methods: Double X participants with TB-presumptive chest radiographs and/or TB symptoms and known risks were referred for confirmatory GeneXpert testing. The demographic and clinical characteristics of all Double X participants and the subset with confirmed TB were summarized. Univariate and multivariable logistic regression modelling was used to evaluate associations between participant characteristics and subclinical TB and between computer-aided detection multilabel radiographic abnormalities and TB.
Results: From 2020 to 2022, 96 631 participants received chest radiographs, with 67 881 (70.2%) reporting no TB symptoms. Among 1144 individuals with Xpert-confirmed TB, 51.0% were subclinical. Subclinical TB prevalence was higher in older age groups, non-smokers, those previously treated for TB and the northern region. Among 11 computer-aided detection multilabel radiographic abnormalities, fibrosis was associated with higher odds of subclinical TB.
Discussion: In Viet Nam, Double X community case finding detected pulmonary TB, including subclinical TB. Computer-aided detection software may have the potential to identify subclinical TB on chest radiographs by classifying multilabel radiographic abnormalities, but further research is needed.
		                        		
		                        		
		                        		
		                        	
8.Parenchymal-sparing anatomical hepatectomy based on portal ramification of the right anterior section: A prospective multicenter experience with short-term outcomes
Truong Giang NGUYEN ; Thanh Khiem NGUYEN ; Ham Hoi NGUYEN ; Hong Son TRINH ; Tuan Hiep LUONG ; Minh Trong NGUYEN ; Van Duy LE ; Hai Dang DO ; Kieu Hung NGUYEN ; Van Minh DO ; Quang Huy TRAN ; Cuong Thinh NGUYEN
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(1):25-33
		                        		
		                        			 Background:
		                        			s/Aims: Parenchymal-sparing anatomical hepatectomy (Ps–AH) based on portal ramification of the right anterior section (RAS) is a new technique to avoid unnecessarily transecting too much liver parenchyma, especially in cases of major anatomical hepatectomy. 
		                        		
		                        			Methods:
		                        			We prospectively assessed 26 patients with primary hepatic malignancies having undergone major Ps–AH based on portal ramification of the RAS from August 2018 to August 2022 (48 months). The perioperative indications, clinical data, intra-operative index, pathological postoperative specimens, postoperative complications, and follow-up results were retrospectively evaluated. 
		                        		
		                        			Results:
		                        			Among the 26 patients analyzed, there was just one case that had intrahepatic cholangiocarcinoma The preoperative level of α– Fetoprotein was 25.2 ng/mL. All cases (100%) had Child–Pugh A liver function preoperatively. The ventral/dorsal RAS was preserved in 19 and 7 patients, respectively. The mean surgical margin was 6.2 mm. The mean surgical time was 228.5 minutes, while the mean blood loss was 255 mL. In pathology, 5 cases (19.2%) had microvascular invasion, and in the group of HCC patients, 92% of all cases had moderate or poor tumor differentiation. Six cases (23.1%) of postoperative complications were graded over III according to the Clavien–Dindo system, including in three patients resistant ascites or intra-abdominal abscess that required intervention. 
		                        		
		                        			Conclusions
		                        			Parenchymal-sparing anatomical hepatectomy based on portal ramification of the RAS to achieve R0-resection was safe and effective, with favorable short-term outcomes. This technique can be used widely in clinical practice. 
		                        		
		                        		
		                        		
		                        	
9.Physiological intracytoplasmic sperm injection does not improve the quality of embryos: A cross-sectional investigation on sibling oocytes
Minh Tam LE ; Hiep Tuyet Thi NGUYEN ; Trung VAN NGUYEN ; Thai Thanh Thi NGUYEN ; Hong Nhan Thi DANG ; Thuan Cong DANG ; Quoc Huy Vu NGUYEN
Clinical and Experimental Reproductive Medicine 2023;50(2):123-131
		                        		
		                        			 Objective:
		                        			This study aimed to compare the efficacy of physiological intracytoplasmic sperm injection (PICSI) and intracytoplasmic sperm injection (ICSI) in terms of the fertilization rate and embryo quality using sibling oocyte cycles. 
		                        		
		                        			Methods:
		                        			This prospective, cross-sectional study collected data from 76 couples who underwent their first cycle at the Hue Center for Reproductive Endocrinology and Infertility, Vietnam, between May 2019 and November 2021. The inclusion criteria were cycles with at least eight oocytes and a sperm concentration of 5×106/mL. Sperm parameters, sperm DNA fragmentation (SDF), fertilization, and the quality of cleavage-stage embryos on day 2 and blastocysts on day 5 were examined. 
		                        		
		                        			Results:
		                        			From 76 ICSI cycles, 1,196 metaphase II (MII) oocytes were retrieved, half of which were randomly allocated to either the PICSI (n=592) or ICSI (n=604) treatment group. The results showed no significant difference between the two groups in terms of fertilization (72.80% vs. 75.33%, p=0.32), day 2 cleavage rate (95.13% vs. 96.04%, p=0.51), blastulation rate (52.68% vs. 57.89%), and high-quality blastocyst rate (26.10% vs. 31.13%, p=0.13). However, in cases where SDF was low, 59 cycles consisting of 913 MII oocytes produced a considerably higher blastulation rate with PICSI than with ICSI (50.49% vs. 35.65%, p=0.00). There were no significant differences between the pregnancy outcomes of the PICSI and ICSI embryo groups following embryo transfer. 
		                        		
		                        			Conclusion
		                        			Using variable sperm quality provided no benefit for PICSI versus ICSI in terms of embryo outcomes. When SDF is low, PICSI appears to be able to produce more blastocysts. 
		                        		
		                        		
		                        		
		                        	
10.Utility of narrow-band imaging with or without dual focus magnification in neoplastic prediction of small colorectal polyps: a Vietnamese experience
Tien Manh HUYNH ; Quang Dinh LE ; Nhan Quang LE ; Huy Minh LE ; Duc Trong QUACH
Clinical Endoscopy 2023;56(4):479-489
		                        		
		                        			 Background/Aims:
		                        			Accurate neoplastic prediction can significantly decrease costs associated with pathology and unnecessary colorectal polypectomies. Narrow band imaging (NBI) and dual-focus (DF) mode are promising emerging optical technologies for recognizing neoplastic features of colorectal polyps digitally. This study aimed to clarify the clinical usefulness of NBI with and without DF assistance in the neoplastic prediction of small colorectal polyps (<10 mm). 
		                        		
		                        			Methods:
		                        			This cross-sectional study included 530 small colorectal polyps from 343 consecutive patients who underwent colonoscopy at the University Medical Center from September 2020 to May 2021. Each polyp was endoscopically diagnosed in three successive steps using white-light endoscopy (WLE), NBI, and NBI-DF and retrieved for histopathological assessment. The diagnostic accuracy of each modality was evaluated with reference to histopathology. 
		                        		
		                        			Results:
		                        			There were 295 neoplastic polyps and 235 non-neoplastic polyps. The overall accuracies of WLE, WLE+NBI, and WLE+NBI+NBI-DF in the neoplastic prediction of colorectal polyps were 70.8%, 87.4%, and 90.8%, respectively (p<0.001). The accuracy of WLE+NBI+NBI-DF was significantly higher than that of WLE+NBI in the polyp size ≤5 mm subgroup (87.3% vs. 90.1%, p<0.001). 
		                        		
		                        			Conclusions
		                        			NBI improved the real-time neoplastic prediction of small colorectal polyps. The DF mode was especially useful in polyps ≤5 mm in size. 
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail