1.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
2.Biosensor analysis technology and its research progress in drug development of Alzheimer's disease
Shu-qi SHEN ; Jia-hao FANG ; Hui WANG ; Liang CHAO ; Piao-xue YOU ; Zhan-ying HONG
Acta Pharmaceutica Sinica 2024;59(3):554-564
Biosensor analysis technology is a kind of technology with high specificity that can convert biological reactions into optical and electrical signals. In the development of drugs for Alzheimer's disease (AD), according to different disease hypotheses and targets, this technology plays an important role in confirming targets and screening active compounds. This paper briefly describes the pathogenesis of AD and the current situation of therapeutic drugs, introduces three biosensor analysis techniques commonly used in the discovery of AD drugs, such as surface plasmon resonance (SPR), biolayer interferometry (BLI) and fluorescence analysis technology, explains its basic principle and application progress, and summarizes their advantages and limitations respectively.
3.Advances in the construction of models and applications of Alzheimer's disease based on microfluidic chips
Piao-xue YOU ; Lan CHEN ; Shu-qi SHEN ; Liang CHAO ; Hui WANG ; Zhan-ying HONG
Acta Pharmaceutica Sinica 2024;59(6):1569-1581
Alzheimer's disease (AD) is a progressive neurodegenerative disease associated with dysfunctions related to thinking, learning, and memory of the brain. AD has multiple pathological characteristics with complicated causes, constructing a suitable pathological model is crucial for the research of AD. Microfluidic chip technology integrates multiple functional units on a chip, which can realize microenvironmental control similar to the physiological environment. It is well applied in the construction of pathological model, early diagnosis as well as drug screening of AD. This paper focuses on the construction of AD microfluidic chips model from the perspective of cell type, culture formats and the chips structure as well as the research progress of microfluidic chips in AD application based on the pathological characteristics of AD, which will provide a reference for further elucidation of AD mechanism and drug development.
4.Comparison of psoas major muscle morphology in patients with lumbar disc herniation of lower limb pain and lumbocrural pain
Hui WANG ; Liangfeng WEI ; Yehuang CHEN ; Liang XUE ; Jianwu WU ; Shousen WANG
Chinese Journal of Neuromedicine 2024;23(1):62-65
Objective:To compare the morphological differences of psoas major muscles between patients with lumbar disc herniation (LDH) of lower limb pain and lumbocrural pain based on CT imaging data.Methods:Sixty patients with LDH admitted to Department of Neurosurgery, 900 th Hospital of PLA Joint Logistic Team from January 2012 to February 2023 were included. According to clinical symptoms, they were divided into lower limb pain group and lumbocrural pain group ( n=30). 3D CT images of the psoas major muscles in the 2 groups were reconstructed; the longest transverse axis perpendicular to the longitudinal axis of the psoas major muscle was chosen as the cross-sectional area, and the maximum psoas major muscle cross-sectional area was calculated; maximum psoas major muscle cross-sectional area index (PI max) was defined as ratio of maximum psoas major muscle cross-sectional area and L 5 vertebral cross-sectional area. PI max difference between lower limb pain group and lumbocrural pain group was compared; PI max difference among patients with different pain degrees (visual analog scale [VAS] scores) or pain courses was further compared in both lower limb pain group and lumbocrural pain group. Pearson correlation was used to analyze the correlations of PI max with pain degree and pain course in the 2 groups. Results:PI max in lower limb pain group was significantly larger than that in lumbocrural pain group (0.62±0.05 vs. 0.54±0.04, t=7.320, P<0.001). PI max in patients with severe pain from both lower limb pain group and lumbocrural pain group was significantly smaller than that in patients with moderate pain (0.61±0.05 vs. 0.65±0.04, t=2.422, P=0.022; 0.53±0.03 vs. 0.58±0.04, t=3.502, P=0.002). PI max in patients with short pain course from both lower limb pain group and lumbocrural pain group was significantly larger than that in patients with long pain course (0.64±0.05 vs. 0.59±0.04, t=2.570, P=0.016; 0.57±0.04 vs. 0.53±0.03, t=2.941, P=0.007). Pearson correlation showed that PI max was negatively correlated with pain degree and pain course in LDH patients from both groups ( P<0.05). Conclusion:Atrophy of psoas major muscles in LDH patients is aggravated with increased pain degree and pain course.
5.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
6.Multicenter evaluation of the diagnostic efficacy of jaundice color card for neonatal hyperbilirubinemia
Guochang XUE ; Huali ZHANG ; Xuexing DING ; Fu XIONG ; Yanhong LIU ; Hui PENG ; Changlin WANG ; Yi ZHAO ; Huili YAN ; Mingxing REN ; Chaoying MA ; Hanming LU ; Yanli LI ; Ruifeng MENG ; Lingjun XIE ; Na CHEN ; Xiufang CHENG ; Jiaojiao WANG ; Xiaohong XIN ; Ruifen WANG ; Qi JIANG ; Yong ZHANG ; Guijuan LIANG ; Yuanzheng LI ; Jianing KANG ; Huimin ZHANG ; Yinying ZHANG ; Yuan YUAN ; Yawen LI ; Yinglin SU ; Junping LIU ; Shengjie DUAN ; Qingsheng LIU ; Jing WEI
Chinese Journal of Pediatrics 2024;62(6):535-541
Objective:To evaluate the diagnostic efficacy and practicality of the Jaundice color card (JCard) as a screening tool for neonatal jaundice.Methods:Following the standards for reporting of diagnostic accuracy studies (STARD) statement, a multicenter prospective study was conducted in 9 hospitals in China from October 2019 to September 2021. A total of 845 newborns who were admitted to the hospital or outpatient department for liver function testing due to their own diseases. The inclusion criteria were a gestational age of ≥35 weeks, a birth weight of ≥2 000 g, and an age of ≤28 days. The neonate′s parents used the JCard to measure jaundice at the neonate′s cheek. Within 2 hours of the JCard measurement, transcutaneous bilirubin (TcB) was measured with a JH20-1B device and total serum bilirubin (TSB) was detected. The Pearson′s correlation analysis, Bland-Altman plots and the receiver operating characteristic (ROC) curve were used for statistic analysis.Results:Out of the 854 newborns, 445 were male and 409 were female; 46 were born at 35-36 weeks of gestational age and 808 were born at ≥37 weeks of gestational age. Additionally, 432 cases were aged 0-3 days, 236 cases were aged 4-7 days, and 186 cases were aged 8-28 days. The TSB level was (227.4±89.6) μmol/L, with a range of 23.7-717.0 μmol/L. The JCard level was (221.4±77.0) μmol/L and the TcB level was (252.5±76.0) μmol/L. Both the JCard and TcB values showed good correlation ( r=0.77 and 0.80, respectively) and agreements (96.0% (820/854) and 95.2% (813/854) of samples fell within the 95% limits of agreement, respectively) with TSB. The JCard value of 12 had a sensitivity of 0.93 and specificity of 0.75 for identifying a TSB ≥205.2?μmol/L, and a sensitivity of 1.00 and specificity of 0.35 for identifying a TSB ≥342.0?μmol/L. The TcB value of 205.2?μmol/L had a sensitivity of 0.97 and specificity of 0.60 for identifying TSB levels of 205.2 μmol/L, and a sensitivity of 1.00 and specificity of 0.26 for identifying TSB levels of 342.0 μmol/L. The areas under the ROC curve (AUC) of JCard for identifying TSB levels of 153.9, 205.2, 256.5, and 342.0 μmol/L were 0.96, 0.92, 0.83, and 0.83, respectively. The AUC of TcB were 0.94, 0.91, 0.86, and 0.87, respectively. There were both no significant differences between the AUC of JCard and TcB in identifying TSB levels of 153.9 and 205.2 μmol/L (both P>0.05). However, the AUC of JCard were both lower than those of TcB in identifying TSB levels of 256.5 and 342.0 μmol/L (both P<0.05). Conclusions:JCard can be used to classify different levels of bilirubin, but its diagnostic efficacy decreases with increasing bilirubin levels. When TSB level are ≤205.2 μmol/L, its diagnostic efficacy is equivalent to that of the JH20-1B. To prevent the misdiagnosis of severe jaundice, it is recommended that parents use a low JCard score, such as 12, to identify severe hyperbilirubinemia (TSB ≥342.0 μmol/L).
7.SOX7 inhibits colorectal cancer proliferation,invasion and migration through the SHP-2/Wnt/β-catenin/ROS pathway
Xueliang WU ; Likun WANG ; Hongqing MA ; Shaodong LI ; Yan LIANG ; Zhilong HUI ; Lei HAN ; Jun XUE
Acta Universitatis Medicinalis Anhui 2024;59(7):1237-1243
Objective To investigate the molecular mechanisms by which SOX7 regulates the SHP-2/Wnt/β-cate-nin/ROS pathway,affecting the proliferation,invasion,and migration of colorectal cancer cells.Methods Twenty nude mice with subcutaneously transplanted tumor models were randomly divided into four groups:SOX7 NC(n=5),SOX mimic(n=5),SOX7 NC+PHPS1(n=5),and SOX7 mimic+PHPS1(n=5)to observe tumor growth.Human colorectal cancer cell line SW480 cells were transfected via lipofection and divided into six groups:SOX7 NC,SOX7 mimic,SOX7 NC+H2 O2,SOX7 mimic+H2O2,SOX7 NC+PHPS1,and SOX7 mimic+PHPS1.The ex-pression of SHP-2/Wnt/β-catenin/ROS pathway-related proteins in SW480 cells of each group was detected by Western blot.The invasion and migration capabilities of SW480 cells were assessed through scratch and Transwell invasion assays,while cell proliferation was evaluated using CCK-8.Results In vivo experiments demonstrated that tumors in the SOX7 mimic group were significantly smaller than those in the SOX7 NC group(P<0.01).Tumors treated with PHPS1 intervention exhibited a significant increase in volume.There was no statistical significance in the difference in tumor volume between the SOX7 mimic+PHPS1 group and the SOX7 NC+PHPS1 group.In vitro experiments revealed that SOX7 mimic inhibited the expression of Wnt,β-catenin,NOX2,NOX4,PI3K,P-PI3K,AKT,P-AKT proteins(P<0.01),and promoted the expression of p-SHP-2 protein(P<0.01).The addition of hydrogen peroxide and SHP-2 inhibitor reversed the effects of SOX7 on SW480 cells(P<0.05),and significantly promoted the expression levels of Wnt,β-catenin,NOX2,NOX4,PI3K,P-PI3K,AKT,P-AKT proteins,with no sig-nificant difference,while significantly reducing the expression levels of SHP-2,p-SHP-2 proteins,with no significant difference.PHPS1 inhibited the expression of SHP-2,p-SHP-2 proteins(P<0.05)and upregulated the expression of Wnt,β-catenin,NOX2,NOX4,PI3K,P-PI3K,AKT,P-AKT proteins(P<0.05).Scratch,Transwell invasion and migration assays,and CCK-8 experiments indicated that SOX7 suppressed the migration,invasion,and proliferation of SW480 cells through oxidative stress and the SHP-2 pathway(P<0.01),while H2O2 and PHPS1 intervention promoted the migration,invasion,and proliferation of SW480 cells(P<0.05).Conclusion SOX7 can suppress the proliferation,invasion,and migration of colorectal cancer by targeting the SHP-2/Wnt/β-catenin/ROS pathway.
8.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
9.Study on the effect of different administration regimens of iprrazole enteric-coated tablets on inhibiting gastric acid secretion
Ting-Yuan PANG ; Zhi WANG ; Zi-Shu HU ; Zi-Han SHEN ; Yue-Qi WANG ; Ya-Qian CHEN ; Xue-Bing QIAN ; Jin-Ying LIANG ; Liang-Ying YI ; Jun-Long LI ; Zhi-Hui HAN ; Guo-Ping ZHONG ; Guo-Hua CHENG ; Hai-Tang HU
The Chinese Journal of Clinical Pharmacology 2024;40(1):92-96
Objective To compare the effects of 20 mg qd and 10 mg bidadministration of iprrazole enteric-coated tablets on the control of gastric acid in healthy subjects.Methods A randomized,single-center,parallel controlled trial was designed to include 8 healthy subjects.Randomly divided into 2 groups,20 mg qd administration group:20 mg enteric-coated tablets of iprrazole in the morning;10 mg bid administration group:10 mg enteric-coated tablets of iprrazole in the morning and 10 mg in the evening.The pH values in the stomach of the subjects before and 24 h after administration were monitored by pH meter.The plasma concentration of iprazole after administration was determined by HPLC-MS/MS.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin(V8.0)software.Results The PK parameters of iprrazole enteric-coated tablets and reference preparations in fasting group were as follows:The Cmax of 20 mg qd group and 10 mg bid group were(595.75±131.15)and(283.50±96.98)ng·mL-1;AUC0-t were(5 531.94±784.35)and(4 686.67±898.23)h·ng·mL-1;AUC0-∞ were(6 003.19±538.59)and(7 361.48±1 816.77)h·ng·mL-1,respectively.The mean time percentage of gastric pH>3 after 20 mg qd and 10 mg bid were 82.64%and 61.92%,and the median gastric pH within 24 h were 6.25±1.49 and 3.53±2.05,respectively.The mean gastric pH values within 24 h were 5.71±1.36 and 4.23±1.45,respectively.The correlation analysis of pharmacokinetic/pharmacodynamics showed that there was no significant correlation between the peak concentration of drug in plasma and the inhibitory effect of acid.Conclusion Compared with the 20 mg qd group and the 10 mg bid group,the acid inhibition effect is better,the administration times are less,and the safety of the two administration regimes is good.
10.Simulation study of brain electrical impedance tomography based on radial basis function neural network
Tao ZHANG ; Xin-Yi WANG ; Jiang-Hui HAO ; Lei LIANG ; Can-Hua XU ; Feng FU ; Xue-Chao LIU
Chinese Medical Equipment Journal 2024;45(10):1-6
Objective To study the ability of radial basis function neural network(RBFNN)with different implementations for electrical impedance tomography(EIT)under real brain shapes,to evaluate the advantages and disadvantages of different approaches,and to provide a reference for the selection of practical imaging methods.Methods COMSOL Multiphysics was used to establish a multilayer 2D model with real structure based on brain CT and an EIT simulation dataset.The effects of the exact RBFNN,the orthogonal least squares-based RBFNN(OLS RBFNN)and the K-Means-based BRFNN(K-Means RBFNN)on the image reconstruction result were explored with the dataset constructed.The root mean square error(RMSE)and image correlation coefficient(ICC)were adopted to evaluate the imaging results.Results EIT could be completed with all the three RBFNNs without noise,and the exact RBFNN had the best results with average ICC and RMSE of 0.784 and 0.467,respectively,in the test set.The OLS RBFNN had the best imaging results at a hidden node of 50,with an average ICC and RMSE of 0.788 and 0.462,respectively.The K-Means RBFNN achieved the best imaging results at noise levels of 30,40,50,60,70 and 80 dB with stable ICC and RMSE and high robustness.Conclusion All the three RBFNNs can be used for brain EIT image reconstruction with their own advantages and disadvantages,and the RBFNN has to be selected for EIT reconstruc-tion based on considerations on actual conditions.[Chinese Medical Equipment Journal,2024,45(10):1-6]


Result Analysis
Print
Save
E-mail