1.Subchronic exposure to benzoapyrene results in lung tissue cell damage caused by ferroptosis in mice
Chaoli ZHOU ; Shihan DING ; Hui HE ; Zhirui MA ; Jie CHEN ; Xingdi GUO ; Yi LYU ; Jinping ZHENG
Journal of Environmental and Occupational Medicine 2025;42(8):971-977
Background Exposure to benzo[a]pyrene (BaP) may impair lung function through various mechanisms; however, it remains uncertain whether BaP induces ferroptosis in lung tissue cells, resulting in lung function impairment. Objective To investigate the ferroptosis of lung tissue cells triggered by subchronic BaP exposure in mice and its correlation with lung injury, and to explore the function of ferroptosis in BaP-induced lung tissue damage. Method Seventy-two healthy 3-weeks-old male C57BL/6J mice were acclimatized for 1 week and then randomly divided into six groups: control group (corn oil 10 mL·kg−1), low-dose BaP group (2.5 mg·kg−1), medium-dose BaP group (5 mg·kg−1), high-dose BaP group (10 mg·kg−1), BaP+ferrostatin-1 (Fer-1) group (10 mg·kg−1+1 mg·kg−1), and Fer-1 group (1 mg·kg−1), with 12 mice each group. Corn oil and BaP were administered via gavage every other day, followed by an intraperitoneal injection of Fer-1 the subsequent day, throughout a period of 90 d. Whole-body plethysmography was applied to detect lung function; hematoxylin-eosin staining (HE) and Masson staining were used to observe lung tissue injury and fibrosis; microscopy of alveolar epithelial cells was conducted to reveal mitochondrial morphology; biochemical assays were used to measure the content of tissue iron, malondialdehyde (MDA), and glutathione (GSH), as well as the activity of glutathione peroxidase (GSH-Px); Western blotting and real-time quantitative PCR (RT-qPCR) analyses were performed to reveal the protein and mRNA expression of ferroptosis markers. Results Compared to the control group, the high-dose BaP group showed a significant increase in expiration time (Te) (P<0.01), and a significant decrease in ratio rate of achieving peak expiratory flow (Rpef), tidal volume (TVb), peak inspiratory flow (PIF), minute volume (MVb), and peak expiratory flow (PEF) (P<0.05 or 0.01). Based on the results of HE and Masson staining, partial destruction of alveolar structures, thickening of alveolar walls, infiltration of inflammatory cells, significant thickening of tracheal walls and a large deposition of collagen fibers in lung tissue were observed in the medium- and high-dose BaP groups. By microscopy, the alveolar epithelial cells exposed to low-dose BaP showed condensed chromatin, and the mitochondria exposed to medium and high-dose BaP showed wrinkles, increased mitochondrial membrane density, and diminished mitochondrial cristae. Compared to the control group, in the medium- and high-dose BaP groups, the lung tissue iron content and the expression levels of ACSL4 protein and mRNA significantly elevated (P<0.01 or 0.05), while the mRNA expression level of SLC7A11 significantly decreased (P<0.05); in the high-dose BaP group, the MDA content, COX2 protein, and PTGS2 mRNA expression levels significantly increased (P<0.05 or 0.01), GSH content and GSH-Px activity, GPX4 protein and mRNA expression levels, and the expression level of SLC7A11 protein significantly decreased (P<0.01 or 0.05). The ferroptosis inhibitor Fer-1 markedly reversed respiratory function, morphology, mitochondrial alterations, and the aforementioned ferroptosis-related biochemical indicators. Conclusion Subchronic exposure to BaP can induce ferroptosis in mice lung tissue cells, resulting in compromised lung function.
2.Use of Thread-hanging Microwave Antenna to Assist in Precise Puncture of Lung Nodule and Influencing Factors
Hui JIN ; Jie TAN ; Shan SONG ; Yinghu WANG ; Lihua MA
Cancer Research on Prevention and Treatment 2024;51(2):110-114
Objective To explore a precise method with a microwave antenna for puncture of pulmonary nodules and analyze phenomena that affect the puncture results. Methods Clinical data of 107 cases with solitary malignant pulmonary nodules were collected, and the mean length of pulmonary nodules was 13.6±0.6 mm in CT axial position. A thread-hanging method was used to assist the puncture of pulmonary nodules. The procedure was successful when the needle was not withdrawn and inserted into the central region of the nodule. The success rate and complications of the pulmonary procedure were recorded. The incidence of the following phenomena were also documented: needle coercing, needle slipping, needle tip pushing, pulmonary nodule prolapsing, radial nodule deformation, nodular masking, and radial movement distance of needle tip. Results In all of 107 cases evaluated, the antenna puncture was successful in 101 cases (94.4%) but failed in 6 cases (5.6%). Pneumothorax and pulmonary hemorrhage occurred in 23 (21.5%) and 19 cases (17.8%), respectively. The following phenomena occurred: needle coercing in 9 cases (8.4%), needle slipping in 6 cases (5.6%), needle tip pushing in 19 cases (17.8%), pulmonary nodule prolapsing in 15 cases (14%), radial nodule deformation in 14 cases (13.1%), and nodular masking in 5 cases (4.7%). The mean radial adjusting distance of needle tip was 0.7±0.4 cm. Conclusion The thread-hanging method can assist in the accurate puncture of microwave antenna for pulmonary nodules. We should focus and deal with phenomena that may occur and affect the result of puncture.
3.Establishment and validation of a prediction model of hip fracture risk factors in elderly stroke patients
Li DU ; Yiming MA ; Hui ZHAO ; Guiyun CUI ; Jie ZU
Chinese Journal of Tissue Engineering Research 2024;28(36):5793-5798
BACKGROUND:Prevention of fractures after stroke is very important,and there are currently no models to predict the occurrence of hip fractures after stroke. OBJECTIVE:To investigate the risk factors leading to hip fracture in stroke patients and to establish a risk prediction model to visualize this risk. METHODS:A total of 439 stroke patients were selected from the Affiliated Hospital of Xuzhou Medical University from June 2014 to June 2017,including 107 males and 332 females,with a mean age of(71.38±9.74)years.They were divided into fracture group(n=35)and non-fracture group(n=404)according to the presence or absence of hip fracture.Univariate and multivariate analyses were used to determine the risk factors for hip fracture after stroke.The data were randomly divided into training set(70%)and test set(30%).Nomogram predicting the risk of hip fracture occurrence was created based on the results of the multifactor analysis,and performance was evaluated using receiver operating characteristic curve,calibration curves,and decision curve analysis.A web calculator was created to facilitate a more convenient interactive experience for clinicians. RESULTS AND CONCLUSION:(1)Univariate analysis showed significant differences between the two groups in the number of falls,smoking,hypertension,glucocorticoids,number of strokes,Mini-Mental State Examination,visual acuity level,National Institute of Health Stroke Scale,Berg Balance Scale,and Stop Walking When Talking scale scores(P<0.05).(2)Multivariate analysis showed that number of falls[OR=17.104,95%CI(3.727-78.489),P=0.000],National Institute of Health Stroke Scale[OR=1.565,95%CI(1.193-2.052),P=0.001],Stop Walking When Talking[OR=12.080,95%CI(2.398-60.851),P=0.003]were independent risk factors positively associated with new hip fractures.Bone mineral density[OR=0.155,95%CI(0.044-0.546),P=0.012]and Berg Balance Scale[OR=0.840,95%CI(0.739-0.954),P=0.007]were negatively associated with new hip fractures after stroke.(3)The AUC values of nomogram were 0.956 and 0.907 in the training and test sets,respectively,and the calibration curves showed a high agreement between predicted and actual status with an area under the decision curve of 0.038 and 0.030,respectively.(4)These findings conclude that the number of falls,low bone mineral density,low Berg Balance Scale score,high National Institute of Health Stroke Scale score,and positive Stop Walking When Talking are risk factors for hip fracture after stroke.Based on this,a nomogram with high accuracy was developed and a web calculator(https://stroke.shinyapps.io/DynNomapp/)was created.
4.Pharmacokinetics of JS026 and JS026-JS016 for single intravenous administration in healthy volunteers
Yan TIAN ; Hui-Jing YE ; Jing-Jing WANG ; Nan-Yang LI ; Juan MA ; Xi TAN ; Fan WU ; Jie WANG ; Shu-Yan YU ; Xiao-Jie WU ; Jin-Jie HE ; Jing ZHANG ; Wen-Hong ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2251-2255
Objective To evaluate tolerability,safety and pharmacokinetics of JS026 and JS026-JS016 single dose intravenous infusion in healthy adults.Methods This phase 1,randomized,double-blind,placebo-controlled,dose-escalation study totally included 48 participants:32 healthy subjects were enrolled in JS026 single intravenous infusion groups and 16 healthy subjects were enrolled in JS026-JS016 groups.JS026 was sequentially administered from low dose to high dose(30-1 000 mg),with intravenous infusion of JS026 or placebo in JS026 single-dose groups,and intravenous infusion of JS026-JS016 or placebo in the combination drug groups.Blood was collected according to the time point designed for trial.Serum concentrations of JS026 and JS016 were determined by enzyme linked immunosorbnent assay(ELISA),and pharmacokinetics parameters were calculated by WinNonlin 8.2.The power model method was used to evaluate the linear analysis of dose and drug exposure.Results 47 subjects completed trial and 1 subject lost to follow-up.After a single intravenous injection of JS026 of 30 mg,100 mg,300 mg,600 mg,and 1 000 mg,mean Cmax were(9.47±1.53),(33.20±4.95),(96.10±13.70),(177.00±22.20)and(353.00±56.70)μg·mL-1,respectively;mean AUC0-∞ were(4 225.00±607.00),(1.78 × 104±3 268.00),(5.83 × 104±1 038.00),(1.07 × 105±152.00),(1.66 × 105±327.00)μg·h·mL-1,respectively;mean t1/2 of JS026 were 563-709 h.The Cmax and AUC0-∞ of JS026 were basically similar alone or in combination with JS016.The results of Power model showed that Cmax and AUC0-∞ increased approximately linearly with the increasing dose of JS026.Treatment emergent adverse event was not increasing when dose increased and most of adverse event associated with drugs were abnormal on laboratory tests and haematuria,thus JS026 and JS016 was well tolerated in all groups.Conclusion The single intravenous infusion of JS026 can almost be thought to be a linear relationship between the doses and drug serum exposure.JS016 had no significant effect on serum concentration of JS026 and JS026 was well tolerated and safe in healthy subjects within 30-1 000 mg.
5.Hypericin inhibits the expression of NLRP3 in microglia of Parkinson's disease mice and alleviates the damage of DA-ergic neurons
Li-Shan FAN ; Jia ZHANG ; Si-Xiang NIU ; Qi XIAO ; Hui-Jie FAN ; Lei XU ; Li-Xia YANG ; Lu JIA ; Shao-Chen QIN ; Bao-Guo XIAO ; Cun-Gen MA ; Zhi CHAI
The Chinese Journal of Clinical Pharmacology 2024;40(17):2523-2527
Objective To observe the intervention effect of hypericin(HYP)on 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine(MPTP)-induced Parkinson's disease(PD)mice model and its mechanism.Methods Thirty C57BL/6 mice were randomly divided into normal,model and experimental groups with 10 mice per group.PD mouse model was established after 7 days of intraperitoneal injection of MPTP,and drug intervention was carried out from the first day of modeling.Normal group and model group were intraperitoneally injected with 500 μL·kg·d-1 0.9%NaCl.The experimental group was intraperitoneally injected with 25 mg·kg·d-1 HYP.The three groups of rats were given the drug once each time for 14 days.The expression levels of tyrosine hydroxylase(TH),Nod-like receptor thermal protein domain protein 3(NLRP3)and ionized calcium binding adapter molecule 1(Iba1)in the striatum of nigra were detected by Western blot.Results The climbing time of normal,model and experimental groups was(5.35±0.43),(9.71±1.19)and(8.07±0.34)s;suspension scores were(2.92±0.15),(1.38±0.28)and(1.96±0.28)points;the relative expression levels of TH protein were 1.04±0.06,0.51±0.09 and 0.75±0.07;the relative expression levels of NLRP3 protein were 0.51±0.03,1.00±0.04 and 0.77±0.06;the relative expression levels of Iba1 protein were 0.68±0.10,1.30±0.28 and 0.89±0.05,respectively.The above indexes in the model group were statistically significant compared with the experimental group and the normal group(all P<0.01).Conclusion HYP plays a therapeutic role in PD by inhibiting the expression of NLRP3 inflammasome in PD mice.
6.Methimazole-induced agranulocytosis and other hematologic damages: Bone marrow characteristics and literature review
Yuanlin LUO ; Pan MA ; Jie ZHENG ; Liya FAN ; Hui GUO ; Bao ZHANG ; Bingyin SHI ; Yayi HE
Chinese Journal of Endocrinology and Metabolism 2024;40(3):219-227
Objective:To retrospectively analyze the bone marrow characteristics of methimazole-induced agranulocytosis and other hematologic damage, and to explore its correlation with clinical features and prognosis.Methods:The bone marrow and clinical parameters of 20 patients of Graves′ disease diagnosed with methimazole-induced agranulocytosis at the First Affiliated Hospital of Xi′an Jiaotong University from January 2000 to December 2022 were collected. The intergroup differences in bone marrow characteristics and granulocyte recovery time were analyzed. Differences in peripheral blood and bone marrow characteristics between patients with single agranulocytosis and pancytopenia were compared. Besides, literature review of the bone marrow characteristics of methimazole-induced hematologic diseases was conducted.Results:Compared to patients with bone marrow characteristics of granulocyte and precursor maturation disorders(Type Ⅱ), patients with aplastic marrow(Type Ⅰ) had significant decreases in the proportions of granulocytes in all phases( P<0.05). Patients with bone marrow characteristics of Type Ⅰ had a significant increase in the proportion of the lymphocyte system [51.00%(41.50%, 75.50%) vs 22.00%(14.00%, 35.00%), P=0.002], and got a longer to recovery time [(6.58±1.68)d vs(3.71±1.60)d, P=0.003]; Correlation analysis suggested the granulocyte to erythrocyte ratio was negatively correlated with the granulocyte recovery time( r=-0.520, P=0.023), and the proportion of the bone marrow lymphocyte was positively correlated with granulocyte recovery time( r=0.622, P=0.004). Compared to patients with single agranulocytosis, patients with pancytopenia had a markedly longer hospital stay duration [(27.14±5.27)d vs(14.15±7.36)d, P=0.001]. Literature review suggestsed that methimazole may cause various degrees of damage to blood system and bone marrow. Conclusion:Methimazole can induce a variety of hematologic damages. Analysis of bone marrow characteristics can aid in further prognosis assessment. Clinicians should be vigilant about potential hematologic adverse reactions when using methimazole and promptly diagnose and treat them to prevent serious consequences.
7.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.
8.Study on the effects of AI reconstruction algorithm based on different tube voltages on CT imaging quality and radiation dose of chest phantom
Qingtao HUI ; Ting LIU ; Xiang QING ; Jie LI ; Guan WANG ; Chun MA
China Medical Equipment 2024;21(3):19-23
Objective:To investigate the effects of different tube voltages combined with artificial intelligence reconstruction algorithm(CI)on the computed tomography(CT)imaging quality and radiation dose of chest phantom on the basis of the CT scan for an adult male simulated chest phantom(PH-N1).Methods:A 512-slice CT scanner of ultrahigh-end was adopted to conduct scan,and the images were divided into 70 kV group,80 kV group,100 kV group and 120 kV group according to different tube voltage.For 4 groups of CT scan images with different tube voltages,the 10%,30%,50%,70%and 90%CI were adopted to reconstruct 1mm thin layer image.The CT volume dose index(CTDIvol)and the dose-length product(DLP)of the scans of 4 groups were compared.The CT values and standard deviation(SD)values of the aorta,abdominal wall fat and erector spine muscle were measured.Two senior diagnostic physicians with more than 5 years of work experience independently and double-blindly evaluated the image quality by using 5-point scale.A Kappa consistency test was conducted.One-way analysis of variance was adopted to compare the differences of CT values and SD values of the tissues of image targets.The Friedman rank-sum test was adopted to compare the differences of subjective image qualities among different groups.Results:The differences of CTDIvol and DLP among 4 groups with different tube voltages were significant(F=1855.617,3996.118,P<0.05),respectively.Under 70 kV tube voltage,there were no significant differences in CT values of the aorta,abdominal wall fat and erector spine muscle,which were reconstructed by using 10%,30%,50%,70%and 90%CI(P>0.05),while the differences of SD values among them were statistically significant(F=32.267,53.327,14.873,P<0.05),respectively.Under the different tube voltages of 4 groups,which were reconstructed by 90%CI,the CT values of aorta,abdominal wall fat and erector spine muscle gradually decreased with decreasing of tube voltage,the differences were significant(F=139.899,2563.93,219.231,P<0.05),respectively.The consistency of subjective scores between two diagnostic physicians was better for each group of images(Kappa=0.712~0.869).Conclusion:Compared with 80 kV,90 kV and 120 kV images,the reconstructed images with 90%CI algorithm under 70 kV tube voltage can significantly reduce the radiation dose,and the images have a favorable signal-to-noise ratio at the same time.
9.Cloning and interacted protein identification of AP1 homologous gene from Lonicera macranthoides
Ya-xin YU ; Li-jun LONG ; Chang-zhu LI ; Hui-jie ZENG ; Zhong-quan QIAO ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(10):2880-2888
The
10.The taste correction process of ibuprofen oral solution based on the combination of electronic tongue technology and artificial taste comprehensive evaluation
Rui YUAN ; Yun-ping QU ; Yan WANG ; Ya-xuan ZHANG ; Wan-ling ZHONG ; Xiao-yu FAN ; Hui-juan SHEN ; Yun-nan MA ; Jin-hong YE ; Jie BAI ; Shou-ying DU
Acta Pharmaceutica Sinica 2024;59(8):2404-2411
This experiment aims to study the taste-masking effects of different kinds of corrigent used individually and in combination on ibuprofen oral solution, in order to optimize the taste-masking formulation. Firstly, a wide range of corrigent and the mass fractions were extensively screened using electronic tongue technology. Subsequently, a combination of sensory evaluation, analytic hierarchy process (AHP)-fuzzy mathematics evaluation, and Box-Behnken experimental design were employed to comprehensively assess the taste-masking effects of different combinations of corrigent on ibuprofen oral solution, optimize the taste-masking formulation, and validate the results. The study received ethical approval from the Review Committee of the Beijing University of Chinese Medicine (ethical code: 2024BZYLL0102). The results showed that corrigent fractions and types were screened separately through single-factor experiments. Subsequently, a Box-Behnken response surface design combined with AHP and fuzzy mathematics evaluation was used to fit a functional model:


Result Analysis
Print
Save
E-mail