1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
		                        		
		                        			
		                        			Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
		                        		
		                        		
		                        		
		                        	
7.Randomized controlled study on treatment of intertrochanteric fracture of femur with proximal femoral nail antirotation assisted by robot navigation
Xi-Cong CHEN ; Jian CAI ; Hui-Liang ZENG ; Guo-Cai CHEN ; Guan-Ming ZHOU
Journal of Regional Anatomy and Operative Surgery 2024;33(9):768-772
		                        		
		                        			
		                        			Objective To investigate the therapeutic effects of proximal femoral nail antirotation(PFNA)assisted by robot navigation and PFNA guided by C-arm X-ray machine for the treatment of intertrochanteric fracture of femur(IFOF).Methods The 100 patients with unilateral IFOF in our hospital were selected as the study subjects.They were divided into the control group(50 cases)and the robot-assisted group(50 cases)according to random number table method.The control group was treated with PFNA internal fixation under C-arm X-ray machine fluoroscopy,and the robot-assisted group was treated with PFNA internal fixation assisted by robot navigation.Surgical indicators,fracture reduction and fracture healing,stress response indexes,hip joint function,quality of life score and incidence of surgery related complications were compared between the two groups.Results The operation time,total fluoroscopy time,nail placement time and fracture healing time of the robot-assisted group were shorter than those of the control group(P<0.05);and the intraoperative blood loss,guide needle adjustment frequency,and fluoroscopy frequency of the robot-assisted group were less than those of the control group(P<0.05).The fracture reduction and fracture healing in the robot-assisted group were better than those in the control group(P<0.05).Two days after operation,the levels of serum norepinephrine(NE),angiotensin Ⅱ(Ang Ⅱ)and superoxide dismutase(SOD)in the two groups were higher than those before operation(P<0.05),and the levels of serum NE,Ang Ⅱ and SOD in the robot-assisted group were lower than those in the control group(P<0.05).The Harris score and 36-item short-form(SF-36)score of patients 7 days and 3 months after surgery in the two groups were higher than those before surgery(P<0.05),and the above scores 3 months after surgery were higher than those 7 days after surgery(P<0.05).Harris score and SF-36 score 7 days and 3 months after operation in the robot-assisted group were higher than those in the control group(P<0.05).The incidence of complications in the robot-assisted group was lower than that in the control group(P<0.05).Conclusion Compared with the C-arm X-ray machine fluoroscopy,the treatment of IFOF with PFNA assisted by robot navigation can further shorten the operation time,reduce the surgical trauma and the incidence of complications,achieve better effect of fracture reduction and healing,reduce stress response of the body,and improve hip joint function and quality of life for patients.
		                        		
		                        		
		                        		
		                        	
8.miR-495-3P targets BUB1 to regulate the effect of STAT3 signaling pathway on biological behavior of esophageal cancer cells
Hui YANG ; Ning SHI ; Xiaowei CHEN ; Xuejie SONG ; Xi ZHOU ; Fuchun SI
Acta Universitatis Medicinalis Anhui 2024;59(8):1446-1454
		                        		
		                        			
		                        			Objective To investigate the effect of miR-495-3p targeting budding uninhibited by benzimidazoles(BUB1)on signal transducer and activator of transcription 3(STAT3)signaling pathway on biological behavior of esophageal cancer(EC)cells.Methods The differentially expressed genes in EC tissues and normal tissues were screened by the cDNA microarray technique.The differentially expressed genes were analyzed by bioinformatics methods.The target genes of miRNAs were predicted by the TargetScan database and verified by a dual luciferase gene reporter assay.KYSE150 cells were divided into blank control group,NC mimics group and miR-495-3p mim-ics group.The activity of KYSE150 cells were detected by the CCK-8 method.Cell cycle and apoptosis were meas-ured by flow cytometry.The expression of BUB1 mRNA was measured by real-time fluorescence quantitative reverse transcription polymerase chain reaction(RT-qPCR).The levels of BUB1,STAT3,phosphor(p)-STAT3,cyclin dependent kinase 1(CCNB1),cyclin dependent kinase 1(CDK1),B-cell lymphoma-2(Bcl-2),cysteinyl aspar-tate-specific proteinase-3(Caspase-3)and cysteinyl aspartate-specific proteinase-3(Caspase-9)were measured by Western blot.The migration and invasion abilities of the cells were measured by wound-healing and Transwell inva-sion assays.Results Differentially expressed genes were involved in biological processes,signaling pathways and network construction,which were mainly related to cell cycle.BUB1 is the key(Hub)gene,and BUB1 is the tar-get gene of miR-495-3p.In vitro experiments showed that overexpression of miR-495-3p could significantly inhibit the migration and invasion of EC cells and induce apoptosis and G2/M phase arrest.After treatment with overex-pression of miR-495-3p,the expression of Caspase-3 and Caspase-9 in EC cells increased significantly(P<0.01),while the expression of Bcl-2,BUB 1,CCNB1,CDK1 and p-STAT3 decreased significantly(P<0.01).Moreover,the STAT3 signaling pathway might play an important role in this process.Conclusion miR-495-3p may influence the biological behavior of esophageal cancer cells by down-regulating BUB 1-mediated STAT3 signaling pathway.
		                        		
		                        		
		                        		
		                        	
10.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
		                        		
		                        			OBJECTIVE:
		                        			This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
		                        		
		                        			METHODS:
		                        			We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
		                        		
		                        			RESULTS:
		                        			The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
		                        		
		                        			CONCLUSION
		                        			Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			beta-Thalassemia/genetics*
		                        			;
		                        		
		                        			alpha-Thalassemia/genetics*
		                        			;
		                        		
		                        			Hemoglobinopathies/genetics*
		                        			;
		                        		
		                        			China/epidemiology*
		                        			;
		                        		
		                        			High-Throughput Nucleotide Sequencing
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail