1.Salidroside Ameliorates Lung Injury Induced by PM2.5 by Regulating SIRT1-PGC-1α in Mice
Hong Xiao LI ; Mei Yu LIU ; Hui SHAN ; Feng Jin TAN ; Jian ZHOU ; Jin Yuan SONG ; Qi Si LI ; Chen LIU ; Qun Dong XU ; Li YU ; Wei Wan LI
Biomedical and Environmental Sciences 2024;37(4):367-376
		                        		
		                        			
		                        			Objective This study aimed to clarify the intervention effect of salidroside(SAL)on lung injury caused by PM2.5 in mice and illuminate the function of SIRT1-PGC-1ɑ axis. Methods Specific pathogen-free(SPF)grade male C57BL/6 mice were randomly assigned to the following groups:control group,SAL group,PM2.5 group,SAL+PM2.5 group.On the first day,SAL was given by gavage,and on the second day,PM2.5 suspension was given by intratracheal instillation.The whole experiment consist of a total of 10 cycles,lasting 20 days.At the end of treatment,blood samples and lung tissues were collected and analyzed.Observation of pathological changes in lung tissue using inverted microscopy and transmission electron microscopy.The expression of inflammatory,antioxidants,apoptosis,and SIRT1-PGC-1ɑ proteins were detected by Western blotting. Results Exposure to PM2.5 leads to obvious morphological and pathologica changes in the lung of mice.PM2.5 caused a decline in levels of antioxidant-related enzymes and protein expressions of HO-1,Nrf2,SOD2,SIRT1 and PGC-1ɑ,and an increase in the protein expressions of IL-6,IL-1β,Bax,caspase-9 and cleaved caspase-3.However,SAL reversed the aforementioned changes caused by PM2.5 by activating the SIRT1-PGC-1α pathway. Conclusion SAL can activate SIRT1-PGC-1ɑ to ameliorate PM2.5-induced lung injury.
		                        		
		                        		
		                        		
		                        	
2.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
		                        		
		                        			
		                        			Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
		                        		
		                        		
		                        		
		                        	
3.Expression and Clinical Significance of LINC00475 in Multiple Myeloma
Ling LU ; Dan GUO ; Le-Min HONG ; Yu-Wen JIANG ; Hong-Ming FAN ; Chun-Qun HUANG ; Jin-Feng LU ; Jie CHEN ; Hong-Hui XU ; Hong-Ming HUANG
Journal of Experimental Hematology 2024;32(3):789-793
		                        		
		                        			
		                        			Objective:To investigate the relative expression level and clinical significance of LINC00475 in serum of patients with multiple myeloma(MM).Methods:The expression of LINC00475 in serum of 108 MM patients and five MM cell lines including RPMI 8226,NCI-H929,U266,OPM2 and CAG were detected by real-time fluorescence quantitative PCR.The diagnostic value of LINC00475 in MM was evaluated by receiver operating characteristic(ROC)curve analysis.The correlation of LINC00475 with patients'characteristics was analyzed.Results:Compared with control groups,the expression of LINC00475 was up-regulated in serum of MM patients and MM cell lines(all P<0.05).ROC curve analysis showed that the optimal cut-off value of LINC00475 was 262.4,the area under curve(AUC)was 0.924(95%CI:0.884-0.964),and sensitivity and specificity was 83.3%and 91.7%,respectively,which indicated that LINC00475 had good evaluation value in MM patients.Compared with low-LINC00475 expression group,patients in high-LINC00475 expression group had higher levels of β2-microglobulin(β2-MG)and Cystatin C(Cys-C)but lower albumin(ALB)(all P<0.05).Compared with MM patients with International Staging System(ISS)stage I,the expression level of LINC00475 was significantly higher in patients with stage Ⅱ and Ⅲ(both P<0.05).Conclusion:LINC00475 is helpful to distinguish MM patients from healthy adults,which is correlated with the prognostic indicators such as β2-MG,ALB,and ISS stage.
		                        		
		                        		
		                        		
		                        	
4.In vitro expression and functional analyses of the mutants p.R243Q,p.R241C and p.Y356X of the human phenylalanine hydroxylase
Yong-Hong PANG ; Xiang-Yu GAO ; Zhen-Ya YUAN ; Hui HUANG ; Zeng-Qin WANG ; Lei PENG ; Yi-Qun LI ; Jie LIU ; Dong LIU ; Gui-Rong CHEN
Chinese Journal of Contemporary Pediatrics 2024;26(2):188-193
		                        		
		                        			
		                        			Objective To study the in vitro expression of three phenylalanine hydroxylase(PAH)mutants(p.R243Q,p.R241C,and p.Y356X)and determine their pathogenicity.Methods Bioinformatics techniques were used to predict the impact of PAH mutants on the structure and function of PAH protein.Corresponding mutant plasmids of PAH were constructed and expressed in HEK293T cells.Quantitative reverse transcription polymerase chain reaction was used to measure the mRNA expression levels of the three PAH mutants,and their protein levels were assessed using Western blot and enzyme-linked immunosorbent assay.Results Bioinformatics analysis predicted that all three mutants were pathogenic.The mRNA expression levels of the p.R243Q and p.R241C mutants in HEK293T cells were similar to the mRNA expression level of the wild-type control(P>0.05),while the mRNA expression level of the p.Y356X mutant significantly decreased(P<0.05).The PAH protein expression levels of all three mutants were significantly reduced compared to the wild-type control(P<0.05).The extracellular concentration of PAH protein was reduced in the p.R241C and p.Y356X mutants compared to the wild-type control(P<0.05),while there was no significant difference between the p.R243Q mutant and the wild type control(P>0.05).Conclusions p.R243Q,p.R241C and p.Y356X mutants lead to reduced expression levels of PAH protein in eukaryotic cells,with p.R241C and p.Y356X mutants also affecting the function of PAH protein.These three PAH mutants are to be pathogenic.[Chinese Journal of Contemporary Pediatrics,2024,26(2):188-193]
		                        		
		                        		
		                        		
		                        	
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
		                        		
		                        			
		                        			【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
		                        		
		                        		
		                        		
		                        	
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
		                        		
		                        			
		                        			【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
		                        		
		                        		
		                        		
		                        	
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
		                        		
		                        			
		                        			【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
		                        		
		                        		
		                        		
		                        	
8.Investigation of coordinated development between blood banks and apheresis plasma collection banks
Qun LIU ; Dunzhu GONGJUE ; Qian ZHANG ; Hui YE ; Hua SHEN ; Mingming QIAO ; Linwei LI ; Xingzhe ZHANG ; Xiangwen CHEN ; Liliang CHEN ; Yang LIU ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(8):927-932
		                        		
		                        			
		                        			Objective To explore the factors that affect the coordinated development of blood banks and apheresis plas-ma collection banks(hereinafter referred to as plasma banks),and explore feasible measures for the coordinated develop-ment of blood banks and plasma banks.Methods The blood information management system and blood source information management system were used to retrieve related data of blood and plasma donation from 9 cities in Shandong province from 2017 to 2021.The number of blood donors and plasma donors and the intersection of them were analyzed.The data analysis was performed using chi-square test,and a questionnaire survey was conducted to investigate the policies and information status,as well as expectations for coordinated development for blood and plasma donation.Results From 2017 to 2021,the total number of blood donors in 9 cities was higher than that of plasma donors,both have been increasing year by year,and the increase in plasma donors was significantly higher than that of blood donors(131.78%vs 23.90%,P<0.05).The inter-section proportion of blood and plasma donors had increased from 0.45%in 2017 to 1.04%in 2021,with an increase of 131.11%.Among the administrative regions where the participating blood and plasma banks located,94.2%have not re-leased relevant policy to promote the coordinated development of blood and plasma donation.The majority(63%)expected blood banks and plasma banks to be set at a distance more than 50 km apart.The top four functional requirements for the in-terconnection between blood banks and plasma banks management information system were blood test results(94.61%),ID number(87.54%),blood and plasma donation records(85.51%)and health consultation/examination results(82.15%).The top four elements of coordinated development between blood and plasma banks were policy support(96.25%),informa-tion networking(92.36%),top-level design(87.44%)and cultural construction(86.58%).Conclusion The number of donors who donate both blood(mainly whole blood)and plasma has been increasing year by year,which deserves our close attention.To achieve the coordinated development of blood donation and plasma donation,policy support is the most crucial and fundamental means.Establishment of a standard system and the share of blood and plasma donation information is neces-sary for blood informatization construction.It was critical to promote the coordinated development of blood and plasma dona-tion and ensure blood safety with improving legislation,formulating policies for coordinated development,strengthening top-level design,standardizing the publicity of blood and plasma donation and establishing the idea that blood and plasma dona-tion are equally honorable.
		                        		
		                        		
		                        		
		                        	
9.Effects of quercetin combined with iron death inhibitor on calcium oxalate-induced HK-2 cell damage
Bing-Fei NIE ; Huang-Hui CHEN ; Qun-Jie TAN ; Yu-Feng DU
The Chinese Journal of Clinical Pharmacology 2024;40(14):2028-2032
		                        		
		                        			
		                        			Objective To explore the effect of quercetin combined with iron death inhibitor Ferrostain-1 on oxalate-induced HK-2 cell injury.Methods HK-2 cells were randomly divided into control group(normal cultured cells),model group(0.5 mmol·L-1 calcium oxalate crystals),quercetin group(0.5 mmol·L-1 calcium oxalate crystals+100 μmol·L-1 quercetin),inhibitor group(0.5 mmol·L-1 calcium oxalate crystals+8 μmol·L-1 Ferrostain-1)and combination group(0.5 mmol·L-1calcium oxalate crystals+100 μmol·L-1quercetin+8 μmol·L-1 Ferrostain-1).Cell counting kit-8(CCK-8)assay was used to detect cell survival rate;Western blot was used to detect iron death related protein expression such as glutathione peroxidase 4(GPX4);flow cytometry and Tunel assay were used to detect cell apoptosis,and assay kit was used to detect cellular iron ions and antioxidant levels.Results The cell survival rates of control group,model group,quercetin group,inhibitor group and combination group were(100.00±2.55)%,(54.49±4.11)%,(64.26±6.30)%,(58.03±3.04)%and(79.37±4.29)%,respectively;GPX4 protein expression levels were 0.98±0.11,0.33±0.05,0.56±0.05,0.78±0.07 and 1.11±0.11,respectively;cell apoptosis rates were(4.15±0.28)%,(23.12±2.49)%,(17.28±1.07)%,(15.08±1.41)%and(8.95±0.75)%,respectively;Fe2+levels were(100.00±0.87)%,(162.55±14.70)%,(149.09±9.50)%,(144.95±11.12)%and(131.76±12.18)%,respectively;superoxide dismutase(SOD)levels were(58.67±3.46),(21.56±1.32),(33.60±2.03),(35.15±3.02)and(44.27±3.89)U·mL-1,respectively.The above indicators of the model group were compared with the control group,and the above indicators of the quercetin group,inhibitor group,and combination group were compared with the model group,the above indicators of the combination group were compared with the quercetin group,and inhibitor group,all they all showed statistical significance(all P<0.05).Conclusion Iron death inhibitors can enhance the inhibitory effect of quercetin in vitro on oxalate-induced renal tubular epithelial cell injury.
		                        		
		                        		
		                        		
		                        	
10.Clinical trial of compound sabal berry tablet in the treatment of patients with bladder discomfort after electrocision of benign prostatic hyperplasia
Yu-Feng DU ; Huang-Hui CHEN ; Qun-Jie TAN ; Xiao-Yong GUO
The Chinese Journal of Clinical Pharmacology 2024;40(18):2670-2674
		                        		
		                        			
		                        			Objective To observe the effects of compound sabal berry tablet on bladder discomfort(BD)after electrocision of benign prostatic hyperplasia(BPH).Methods Patients with BPH undergoing transurethral resection of the prostate were divided into treatment group and control group.The control group was treated with tamsulosin hydrochloride sustained-release capsules(0.2 mg,qd)on the day after surgery,while treatment group was treated with compound sabal berry tablets(0.5 g,tid)on basis of control group.All patients were treated for 4 weeks.The clinical curative effect,prostate symptoms,overactive bladder symptoms,changes of urodynamics[maximum detrusor pressure(MDP),maximum urine flow rate(Qmax),maximum cystometric capacity(MCC)],occurrence of BD,inflammatory response indexes[interleukin-6(IL-6),IL-17,tumor necrosis factor-α(TNF-α)]and safety were compared between the two groups.Results There were 45 cases in control group and 49 cases in treatment group.After treatment,total response rate of treatment group was higher than that of control group[95.92%(47 cases/49 cases)vs 82.22%(37 cases/45 cases)],the differences were statistically significant(P<0.05).After treatment,international prostate symptom scores(IPSS)in treatment group and control group were(7.62±1.38)and(10.49±2.05)points;overactive bladder symptom scores(OABSS)were(2.78±0.64)and(3.92±0.72)points;MDP were(32.09±5.12)and(28.32±4.69)cmH2O;Qmax were(18.42±2.53)and(15.37±2.18)mL·s-1;MCC were(289.46±36.81)and(261.42±33.54)mL;incidence of BD were 18.37%(9 cases/49 cases)and 37.78%(17 cases/45 cases);levels of serum IL-6 were(11.34±2.09)and(15.03±2.56)pg·mL-1;levels of serum IL-17 were(30.12±4.73)and(37.57±5.01)pg·mL-1;levels of serum TNF-α were(82.06±12.95)and(98.63±15.70)pg·mL-1.The differences were statistically significant in the above indexes between the treatment group and control group(all P<0.05).The adverse drug reactions in treatment group were mainly on dizziness,rash,nausea and diarrhea,while adverse drug reactions in control group were mainly on dizziness,rash and diarrhea.There was no significant difference in the incidence of adverse reactions between the two groups[10.20%(5 cases/49 cases)vs 8.89%(4 cases/45 cases),P>0.05].Conclusion Compound sabal berry tablet can relieve prostate symptoms and overactive bladder symptoms,improve urodynamics,reduce BD and alleviate inflammatory response in BPH patients after transurethral resection of the prostate.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail