1.Three‐dimensional transesophageal echocardiography of aortic‐mitral valve coupling changes in patients with severe aortic stenosis after surgical aortic valve replacement and transcatheter aortic valve implantation
Lei ZHANG ; Hsiung MINGCHON ; Hongfeng WANG ; Shaohui QU ; Jiawei TIAN
Chinese Journal of Ultrasonography 2019;28(7):595-600
Objective To study the morphologic and functional changes of the aortic‐mitral valve coupling ( AMC) after surgical aortic valve replacement ( SAVR) or transcatheter aortic valve implantation ( T AVI ) in patients with severe aortic stenosis ( AS) using three‐dimensional transesophageal echocardiography ( 3D‐T EE) . Methods Ninty‐three severe AS patients were chosed as AS group in which 43 cases underwent SAVR and 50 cases underwent T AVI . T EE was performed before and after operation . T hirty‐one age‐and gender‐matched patients who underwent 3D‐T EE for exclusion of intracardiac thrombus were selected as control group . Cardiovascular quantitative analysis software was used to measure the parameters of aortic valve ,mitral valve and AMC in the the control group ,the SAVR group and the T AVI group before and after operation . Results ① Compared with control group ,the antero posterior ( AP ) diameter of mitral value in AS group increased ,the ellipticity of mitral valve decreased ,the height of the mitral annulus increased ( all P< 0 .05 ) . T he open area of aortic valve decreased ,the aortic regurgitation area ,aortic regurgitant flow velocity and the diameter of the aortic annulus increased( all P <0 .05) . T here was no statistical difference in aortic‐mitral valvular angle ( AM A ) and other parameters( all P >0 .05) . ②After SAVR ,the anterolateral‐posteromedial diameter ,AP diameter ,perimeter and area of mitral valve decreased ,the ellipticity of mitral valve increased( all P <0 .05) . T he aortic valve opening area increased ,the aortic regurgitation area and aortic regurgitant flow velocity decreased ( all P < 0 .05 ) . T here was no statistical difference in AM A and other parameters( all P >0 .05) . ③After TAVI ,the AP diameter ,height , perimeter and area of mitral valve decreased ,the ellipticity of mitral valve increased ( all P < 0 .05 ) . The aortic valve opening area increased ,the aortic regurgitation area ,aortic regurgitant flow velocity and the diameter of the aortic annulus decreased ( all P < 0 .05 ) . T here was no statistical difference in AM A and other parameters( all P >0 .05) . Conclusions After SAVR and T AVI ,the anatomy and function of AMC in patients with severe AS changed to varying degrees after operation . It demonstrates that the impacts of both AS and repairment of AS on the mitral valve were . In addition ,after SAVR and T AVI ,the geometry and function of aortic and mitral valves of the patients recovered to some degrees .
2.Methodology study for the anatomic structure of aortic root using three-dimensional transesophageal echocardiography
Junli WANG ; Hua DING ; Mingchon HSIUNG ; Lixue YIN ; Weihsian YIN ; Jeng WEI
Chinese Journal of Ultrasonography 2015;(12):1019-1023
Objective To establish a quantitative analysis method for the anatomic structure of aortic root by real-time three-dimensional transesophageal echocardiography,and to explore the reliability and repeatability of this method.Methods Ninety five adult patients underwent RT-3DTEE were included in this study.Full-volume 3D images of aortic root were acquired and analyzed offline with QLab-3DQ (iE33, Philips).The three mutually perpendicular plane were determined.Results 1 )Aortic root:At the end of diastole,the diameter and area of coronary artery sinus bottoms level was 1 .84 cm and 3.45 cm2 ;the diameter and area of top commissural level was 2.97 cm and 7.77 cm 2 ;the diameter and area of sino-tubular junction level was 2.72 cm and 5.44 cm 2 .2)Aortic sinus:right coronary sinus was widest,left coronary sinus was the most stenosis(P <0.05).The repeatability of each parameters was well (P >0.50).The measurement of each parameter,which analysis among different angles showed that 0° region were more accurate than others.Conclusions 3D quantitative analysis to aortic root can be established by full-volume RT-3DTEE images and has better reliability and repeatability.

Result Analysis
Print
Save
E-mail