1.Discussing the pathogenesis and treatment of varicocele based on the essence chamber collaterals
Anmin WANG ; Dongyue MA ; Ziwei ZHAO ; Hao WANG ; Hongyuan CHANG ; Dicheng LUO ; Fu WANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(2):229-234
Varicocele is a common disease of the male reproductive system, and the pampiniform plexus in the spermatic cord manifests abnormal dilatation, extension, and circuity, which is a vasculopathy. In this article, we believe that the relevance of the essence chamber collaterals to the spermatic vein in terms of anatomical morphology and physiological function is high and that when pathogenic qi invades the essence chamber, the qi and collaterals of the essence chamber are out of harmony, the fluid collaterals are impassable, and the blood collaterals are obstrcuted, and the essence chamber collaterals are blockaded with several pathological products, and even intermingled phlegm and blood stasis in the blood collaterals and form vascular clusters, resulting in the formation and development of varicocele. Based on this, this article proposes the core treatment principle of healing, harmonizing, activating, and dredging the collaterals, with the basic treatment method of nourishing qi and harmonizing collaterals, activating blood collaterals, and dredging blood stasis to, respectively treat degree Ⅰ, Ⅱ, and Ⅲ varicocele, aiming to prevent the change of the varicocele, dredge the curvature of the varicocele, and dissipate the knots of the varicocele. The proposal of essence chamber collaterals is of great significance to understanding the common law and pathological aspects of the occurrence and development of essence collateral and vascular lesions from the perspective of integrated traditional Chinese and Western medicine.
2.Different contents of B2O3 affect mechanical properties and bioactivity of bioactive glass scaffolds
Jianchun WANG ; Shuqing YANG ; Xin SU ; Hongyuan WANG
Chinese Journal of Tissue Engineering Research 2024;28(5):712-716
BACKGROUND:Bioactive glass bone repair material has bone-bonding ability,bone induction ability and bone conduction characteristics.However,the performance of bioactive glass does not meet the requirements of clinical application,and the addition of boron is expected to improve the performance of bioactive glass. OBJECTIVE:To study the effect of different contents of B2O3 replacing SiO2 on the mechanical properties and bioactivity of bioactive glass. METHODS:Based on bioactive glass containing phosphorus nitrogen and oxygen(composition:SiO2-CaO-ZnO-Na2O-Si3N4-P2O5),B2O3 was used to partially replace the SiO2.The basic glass containing B2O3 with a mass fraction of 0%(group A),5%(group B),10%(group C),and 15%(group D)was fired using the high-temperature melting method(the total mass fraction of SiO2 and B2O3 in the basic broken glass was 41%).Porous bioactive glass scaffolds were fabricated by the organic foam impregnation method.Uniaxial compression and three-point bending method of universal mechanical testing machine were used to test mechanical properties.Four groups of scaffolds were immersed in simulated body fluids to detect the degradation performance of scaffolds.Scanning electron microscopy was used to observe the morphological changes of scaffolds before and after soaking.X-ray diffraction was used to analyze the phase composition of scaffolds before and after soaking. RESULTS AND CONCLUSION:(1)With the increase of the mass fraction of B2O3,the compressive strength and bending strength of the porous bioactive glass scaffold increased,and there was a significant difference between the compressive strength and bending strength of the four groups(P≤0.05).(2)After soaking in simulated body fluids,the porous bioactive glass scaffolds degraded gradually with the extension of time.At the same soaking time point,the degradation rate of the scaffolds was accelerated with the increase of the mass fraction of B2O3,and the compressive strength and bending strength of the scaffolds in the four groups were significantly different(P≤0.05).(3)Scanning electron microscopy after soaking in simulated body fluids showed that a large number of granular materials were deposited on the surface of group A and group B after soaking for 1 day.After 3 days,the granular materials on the surface fused with each other to form film-like deposits.After 7 days,the films on the surface fused with each other to form pieces,basically covering the entire surface of the specimen.After soaking for 1 day,film-like material deposition was formed on the surface of group C,and after 3 days,the films on the surface were fused into pieces,basically covering the whole surface of the specimen.After soaking for 1 day in group D,flake material covering the whole surface of the specimen could be seen.(4)X-ray diffraction analysis after 1 day of immersion in simulated body fluids showed that the deposits on the surface of the four groups of scaffolds were crystallized hydroxyapatite.(5)B2O3 replacement of SiO2 can enhance the mechanical properties,degradation properties and in vitro mineralization activity of porous bioactive glass scaffolds.
3.Finite element analysis of effect of proximal fibular fracture on knee joint stress in an extended state
Jiaqi WANG ; Jiangan TANG ; Guohua HUANG ; Dece KONG ; Yiding ZHAO ; Lulu GONG ; Hongyuan PAN ; Dewei KONG ; Yue LIU ; Tieyi YANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4757-4762
BACKGROUND:The traditional view is that proximal fibular fractures do not require fixation.Others and our research suggest that the proximal fibular structure plays an important role in the stability of the posterolateral structure of the knee joint,and its mechanism of action is worth studying. OBJECTIVE:To investigate the biomechanical effects of proximal fibular fractures on various structures of the knee joint in an extended state. METHODS:Finite element method was used to conduct simulated biomechanical experiments.A healthy young male volunteer was selected to establish a finite element model of the knee joint in an extended state using MRI and CT image data,and four proximal fibular shapes were simulated(Model A:intact,Model B:1 cm fracture below the fibular head,Model C:1 cm tip defect fracture from the proximal end of the fibula to the distal end,and Model D:2 cm bone defect from the proximal end of the fibula).A longitudinal concentrated load of 1 500 N was applied to the femoral shaft to compare and analyze the distribution and changing trend of the maximum equivalent stress and maximum first principal stress of each structure of the knee joint in an extended state under four working conditions. RESULTS AND CONCLUSION:(1)In Model A,the maximum equivalent stress in the tibial cartilage and lateral compartment of the meniscus was greater than that in the medial compartment,while the maximum first principal stress in the tibial plateau and medial compartment of the meniscus was greater than that in the lateral compartment.The maximum equivalent stress of the medial condyle of the femoral cartilage was greater than that of the lateral condyle,and the maximum first principal stress of the medial condyle of the femoral cartilage was greater than that of the medial condyle.(2)Compared to Model A,there was no significant difference in the magnitude and distribution of the maximum equivalent stress and maximum first principal stress in the cartilage and meniscus of Model C.(3)Compared to Model A,the maximum equivalent stress increase amplitude of Model B was in the order of medial tibial cartilage(14.9%),medial condyle of femoral cartilage(13.6%),and medial meniscus(6.6%).The maximum first principal stress increase amplitude was the medial meniscus(11.06%),the medial tibial cartilage(8.65%),and the medial condyle of the femoral cartilage(7.46%).The maximum equivalent stress increase amplitude of the ligament was as follows:popliteal arch ligament(33.2%)>anterior cruciate ligament(21.3%)>fibular collateral ligament(17%)>posterior cruciate ligament(14.3%)>anterior lateral collateral ligament(13.2%)>medial collateral ligament(10.1%).(4)Compared to Model A,the maximum equivalent stress increasing trend of Model D followed the medial tibial cartilage(19.5%),femoral cartilage medial condyle(17.9%),and medial meniscus(9.9%).The maximum first principal stress in sequence was the medial meniscus(14.04%),the medial tibial cartilage(13.03%),and the medial condyle of the femoral cartilage(11.37%).The increasing trend of maximum equivalent stress in ligaments was as follows:anterior cruciate ligament(25.2%)>posterior cruciate ligament(18.9%)>medial collateral ligament(18.5%)>anterior lateral collateral ligament(12.7%).(5)It is suggested that when the knee joint is extended,a 1 cm fracture below the fibular head and a 2 cm fibular tip bone defect have a significant impact on the structure of the medial ventricular cartilage,anterior cruciate ligament,and posterior lateral ligament complex.
4.Finite element analysis of three-dimensional frame screws and minimally invasive plate for fixation of Sanders Ⅲ calcaneal fractures
Dewei KONG ; Chao SONG ; Liang WU ; Ming WU ; Lulu GONG ; Jiaqi WANG ; Hongyuan PAN ; Xinbin FAN ; Yan ZHANG
Chinese Journal of Tissue Engineering Research 2024;33(33):5289-5294
BACKGROUND:Satisfactory clinical results have been achieved in the treatment of Sanders Ⅲ calcaneal fractures by percutaneous compression fixation with three-dimensional frame screws.However,whether the stability of minimally invasive plate internal fixation can be achieved in terms of biomechanics,and the advantages and disadvantages after comparison are still unknown. OBJECTIVE:To investigate the fixation effect of different internal fixation devices on Sanders Ⅲ calcaneal fractures by finite element analysis. METHODS:A finite element model of Sanders Ⅲ calcaneal fracture was made based on CT data of a 26-year-old healthy male volunteer.The calcaneal fracture models were fixed by minimally invasive three-dimensional frame screws and minimally invasive Y-plate.The longitudinal loads of 350 and 700 N were applied respectively.The displacement and stress distribution of the two models were analyzed,and the stability of each model was compared. RESULTS AND CONCLUSION:(1)The peak stress of bone block and implant in the minimally invasive three-dimensional frame screw model was significantly lower than that in the minimally invasive minimally invasive plate model.The average stress of bone block and implant in the three-dimensional frame screw model was also significantly lower than that in the minimally invasive plate model.(2)The maximum displacement of the two models was located at the medial side of the articular surface of the posterior talus,and the maximum displacement of the three-dimensional frame screw model was smaller than that of the minimally invasive plate model.(3)The longitudinal displacement between the anterior fragment and the medial fragment of the minimally invasive plate model was smaller,and the transverse and vertical displacement between the medial fragment and the middle fragment of the three-dimensional group screw model was smaller.(4)It is concluded that both of the two internal fixation models can provide satisfactory fixation effect.The three-dimensional frame screw model can provide better transverse and vertical stability with more uniform stress distribution and smaller comprehensive displacement of bone fragments,while the minimally invasive plate has more advantages in maintaining longitudinal stability.
5.Comparison on accuracy of bedside lung ultrasound in emergency and combined cardiac-lung and additional ultrasound for diagnosing causes of acute dyspnea
Haotian ZHAO ; Yi LIU ; Yuanlin LIU ; Xiaona WANG ; Yaru YAN ; Huimin NIU ; Heling ZHAO ; Hongyuan XUE ; Li LI
Chinese Journal of Interventional Imaging and Therapy 2024;21(3):134-138
Objective To compare the accuracy of bedside lung ultrasound in emergency(BLUE)and combined cardiac-lung and additional ultrasound(CLAUS)for diagnosing the causes of acute dyspnea.Methods Totally 1 016 patients with acute dyspnea were retrospectively enrolled and divided into cardiogenic pulmonary edema group(n=268),pneumonia group(n=574),pneumothorax group(n=33),pulmonary embolism group(n=67)and CAD(chronic obstructive pulmonary disease/asthma/diaphragmatic dysfunction)group(n=74)according to the causes of acute dyspnea.The findings of CLAUS protocol were compared among groups,and the accuracy of BLUE and CLAUS protocol for diagnosing the causes of acute dyspnea were also compared.Results CLAUS showed that B-B and B-C were the most common modes in cardiogenic pulmonary edema group,while A-B/A-C/B-A/B-B/B-C/C-C modes were common in pneumonia group,and A-A mode was the most common in pneumothorax group,pulmonary embolism group and CAD group.Significant differences of the manifestations of pulmonary ultrasound,pleural feature of anterior chest wall,left/right cardiac insufficiency and abnormal inferior vena cava diameter were found among groups(all P<0.05).The accuracy of BLUE and CLAUS protocol for diagnosing the causes of acute dyspnea was 86.91%(883/1 016)and 94.49%(960/1 016),respectively,the latter was higher than the former(χ2=34.587,P<0.05).Conclusion CLAUS protocol could be used to effectively diagnose the causes of acute dyspnea,with higher accuracy than BLUE protocol.
6.Exploring the traditional Chinese medicine differentiation and treatment of male infertility based on the theory of"maintaining with the sweet and restoring the body fluids"
Hongyuan CHANG ; Hao WANG ; Anmin WANG ; Dongyue MA ; Ziwei ZHAO ; Dicheng LUO ; Jun GUO ; Fu WANG
Journal of Beijing University of Traditional Chinese Medicine 2024;47(7):948-952
Male infertility,a common condition in andrology,falls under the category of"no son"in traditional Chinese medicine(TCM).Unhealthy eating habits and excessive sexual activity,prevalent due to improved living standards,have contributed to the increasing incidence of male infertility.YE Tianshi proposed the theory of"maintaining with the sweet and restoring the body fluids",which emphasizes the importance of ample body fluid for the nourishment of the male essence chamber.Sufficient body fluid is crucial for normal sperm generation.In TCM,the primary pathogenesis of male infertility involves the loss of body fluids and insufficiency of yin essence.Sweet Chinese herbal medicinal is recommended as it nourishes yin,enriches essence,and replenishes male reproductive essence without producing phlegm and dampness.Therefore,when treating male infertility,attention should be given to the use of sweet Chinese herbal medicinal,adhering to the principle of"abundant body fluids nourish kidney yin,and abundant kidney yin supports semen production".Therapies such as purging fire to preserve body fluids with Zengye Decoction,nourishing yin to enrich essence with Guilu Erxian Decoction,benefiting qi to promote fluid production with Buzhong Yiqi Decoction,and warming yang and transporting fluids with Xianfu Shezi Decoction should be considered.Medication and dosage adjustments should be made based on the specific etiology,pathology,and related symptoms to improve the quality of male sperm and enhance the chances of conception.
7.Digital and Intelligent Generalized Inspection in Traditional Chinese Medicine and Related Equipment Development from Evidence-based Perspective
Xiaowei ZHANG ; Xiaoyu ZHANG ; Chen ZHAO ; Mengqi PENG ; Xue XU ; Hongyuan LIN ; Wenhui WANG ; Hongcai SHANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(22):94-101
As the foremost among the four examinations in traditional Chinese medicine (TCM), inspection and related equipment research face challenges in landing and transformation due to variations in evidence quality, lack of standardization, insufficient algorithm transparency, and poor reliability and stability of decision-making. Against the backdrop of rapid development of emerging technologies such as big data, the internet of things, and artificial intelligence, coupled with macro policy support from the government, digital and intelligent generalized inspection in TCM has emerged, with the aim of utilizing digital technologies to overcome the limitations of naked-eye inspection and comprehensively perceive and analyze facial and bodily expressions. The research in this field intelligently correlates Zang-fu organ functions with health conditions and disease progression and establishes a technical system for digital and intelligent inspection, multi-dimensional and multimodal perception, fusion analysis, and decision-making. This system aims to enhance the accuracy of disease risk warning and diagnosis, bridging the gap between inspection equipment and assistance in clinical decision-making. From an evidence-based perspective, this paper systematically examines the research ideas of digital and intelligent inspection and the development of related equipment, deeply explores how to propose clinical practice-oriented key scientific issues, comprehensively acquire and co-apply multi-dimensional data, establish precise inspection models driven by digital intelligence, optimize standards to enhance equipment interoperability and reliability, construct post-effect evaluation mechanisms to promote improvement, and actively address potential risks such as the black box nature and information security in the application of intelligent technology. This paper not only demonstrates the tremendous potential of digital technologies in improving the accuracy and clinical application efficiency of inspection but also provides new perspectives and ideas for the modernization of inspection in TCM, paving the way for the application of inspection in the global medical and health field.
8.Modified reverse puncture technique for esophagojejunostomy during totally laparoscopic total gastrectomy for gastric cancer
Liangjie CHI ; Hongyuan CHEN ; Xiangyu WANG ; Chao XU ; Xuan CHEN ; Liangxiang HUANG ; Fangqin XUE
Chinese Journal of Gastrointestinal Surgery 2024;27(2):182-188
Objective:To evaluate the value of implementing a modified reverse puncture procedure for esophagojejunostomy during totally laparoscopic total gastrectomy.Methods:This was a descriptive case series. Relevant clinical data, including the operative procedure, recovery, and pathological findings of 35 patients with gastric cancer who had undergone esophagojejunostomy with a modified reverse puncture technique during totally laparoscopic total gastrectomy in the Department of Gastrointestinal Surgery, Fujian Provincial Hospital, from June 2022 to January 2023, were prospectively collected and retrospectively analyzed. The age of all patients in the group was (64.9±8.0) years old, with 22 males (62.9%) and a body mass index of (23.2±2.4) kg/m 2. The tumors were located in the upper and middle parts of the stomach in 24 cases (68.6%) and in the junction of the esophagus and stomach in 11 cases (31.4%). Important technical aspects of the modified reverse puncture procedure are as follows. (1) Site of the esophageal incision: a transverse incision is made across the right lateral wall of the esophagus at the expected site of esophageal disjunction. (2) Technique for inserting an anvil: after threading a silk thread through the tip of anvil, the end of the thread is knotted and fixed as the traction thread, after which an anvil is inserted into the esophagus through the esophageal incision, leaving the end of the traction line exposed. Next, a 60-mm linear cutter is placed through the right midclavicular trocar to straighten the opened esophagus vertically, after which the rod of the anvil is pulled out of a small incision that has been made in the esophagus by pulling the traction thread, thus completing anvil placement. (3) Jejunal binding: the jejunum on the central bar of the stapler is fastened with silk thread to the stump of the jejunum, and then tied to the output loop of the jejunum with a gauze strip. Results:All 35 surgeries were successful, with no mortality or conversion to laparotomy. The operation time, anvil insertion time, and digestive tract reconstruction time were (232.7±34.4), (8.5±1.4), and (40.5±4.8) minutes, respectively. The intraoperative blood loss was 100 (20–250) mL and the incision was (5.3±0.9) cm long. The upper surgical margin was negative in all patients and the mean distance between the upper and tumor margins was (3.5±1.2) cm. The mean number of lymph nodes dissected per patient was 33.9±7.1. The times to initial ambulation, initial passage of flatus , postoperative fluid intake, and length of postoperative hospital stay were (3.2±1.1), (3.7±1.5), (4.6±2.3), and (9.8±3.2) days, respectively. Postoperative complications occurred in five patients: one case of anastomotic leak, two of anastomotic stenosis, one of pulmonary infection, and one of incomplete intestinal obstruction, all of which were successfully managed conservatively.Conclusion:Esophagojejunostomy using a modified reverse puncture technique during totally laparoscopic total gastrectomy is safe and feasible for gastric cancer, requiring only a small incision and achieving higher upper esophageal resection margins and good postoperative recovery, and therefore warrants further implementation.
9.MAX germline mutation-associated pheochromocytoma-paraganglioma syndrome: multiple endocrine neoplasia type 5
Xiaoping QI ; Weiying CHEN ; Xudong FANG ; Bijun LIAN ; Hongyuan YU ; Junwei WANG
Chinese Journal of Surgery 2024;62(8):798-804
The individualized precision management of hereditary pheochromocytoma (PHEO) and paraganglioma (PGL) syndromes (PPGLs) based on molecular diagnosis and molecular subtype is becoming more popular. The newly discovered MAX germline mutation-associated PPGLs are autosomally dominant and rare. To raise awareness and explore the effective management of individual diagnosis and treatment, the relevant literature published between January 2011 and February was systematically reviewed. There were a total of 101 patients in the 77 families, involving all 5 exons, containing 44 types of MAX germline mutations and mostly concentrated in exons 3 and 4 (64.4%), the main mutations were nonsense mutations and missense mutations (72.3%), and some were large fragment deletions or insertions, intron variant, gene fusion mutations were relatively infrequent. Furthermore, about 10% of the patients had a paternal parent-of-origin effect. Among the 101 patients, 96 (95.0%) developed PHEO including 15 metastatic PHEO, 61 bilateral PHEO and 35 unilateral PHEO. The age of diagnosis was (31.7±10.9) years (range: 13 to 80 years). The male to female ratio was 1.2∶1. Eleven were accompanied with chest and abdominal PGL. Eight (7.9%) were accompanied by functional pituitary adenoma. And 12 (11.9%) developed other neuroendocrine tumors (NET), of which 8 were accompanied by PHEO, including 4 hyperparathyroidism, 1 gangliocytoma and neuroblastoma, 1 pancreatic NET, 1 medullary thyroid carcinoma and 1 C cell hyperplasia. Six presented concomitant non-NET, including 1 tongue squamous cell carcinoma, 1 papillary thyroid carcinoma, 1 prostate cancer, 1 renal oncocytoma, 1 breast cancer with renal oncocytoma, and 1 thoracic chondrosarcoma with multifocal adenocarcinoma of lung. The remaining 5 cases (5.0%), including 4 other NET (2 ganglioblastoma, 1 abdominal neuroblastoma and 1 pancreatic NET) and 1 asymptomatic child, did not present PHEO. The MAX germline mutation may cause a novel multiple endocrine neoplasia, which can be described as type 5. A comprehensive baseline assessment of neural crest cell-derived diseases such as PPGL, pituitary adenoma, hyperparathyroidism, and/or gangliocytoma (neuroblastoma) was recommended for all people with MAX germline mutations, and the risk of bilateral and/or metastatic PHEO should also be considered. In contrast, patients with PPGLs combined with other NET, such as functional pituitary adenoma, should undergo genetic testing and pedigree screening that includes at least the MAX gene.
10.Finite Element Analysis of Three-Dimensional Screws and Circular Plates for Treating Sanders Type Ⅲ AB Calcaneal Fracture
Hongyuan PAN ; Dewei KONG ; Yue LIU ; Lulu GONG ; Yiding ZHAO ; Dece KONG ; Jiaqi WANG ; Zhi WANG ; Tieyi YANG ; Xinbin FAN
Journal of Medical Biomechanics 2024;39(3):435-441
Objective To investigate the effects of three-dimensional(3D)screws and circular plates on the biomechanical stability of Sanders ABⅢ calcaneal fractures.Methods Calcaneal computed tomography(CT)and magnetic resonance imaging(MRI)data from a 26-year-old volunteer were collected to establish a 3D finite element model of Sanders ⅢAB calcaneal fracture fixed with 3D screws and circular plates.A longitudinal load of 700 N was applied to compare the variations in the stress,displacement of the bone block,and internal fixation in the different models.Results Under 700 N longitudinal loads,the maximum displacement of the bone block and the maximum stress of the bone block and internal fixation were concentrated at the intersection of the posterior talar articular plane internal fixation and fracture line.The overall displacements of the bone blocks in the 3D screw and circular plate models were similar.Compared with the circular plate model,the maximum and average stresses of the bone block and internal fixation in the 3D screw model were lower,and the displacement and stress changes of the 3D screw model were closer to those of the complete calcaneal bone model.Conclusions In the fixation of Sanders ⅢAB calcaneal fractures,both 3D screw and circular plate fixation method can provide good stability.The biomechanical properties of the 3D screws were better than those of the circular plates,which is consistent with the biomechanical characteristics.


Result Analysis
Print
Save
E-mail