1.Mitigating metal artifacts in cone-beam CT images through deep learning techniques
Linghui JIA ; Honglei LIN ; Songwei ZHENG ; Xiujiao LIN ; Dong ZHANG ; Hao YU
Chinese Journal of Stomatology 2024;59(1):71-79
Objective:To develop and evaluate metal artifact removal systems (MARSs) based on deep learning to assess their effectiveness in removing artifacts caused by different thicknesses of metals in cone-beam CT (CBCT) images.Methods:A full-mouth standard model (60 mm×75 mm×110 mm) was three-dimensional (3D) printed using photosensitive resin. The model included a removable and replaceable target tooth position where cobalt-chromium alloy crowns with varying thicknesses were inserted to generate matched CBCT images. The artifacts resulting from cobalt-chromium alloys with different thicknesses were evaluated using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). CNN-MARS and U-net-MARS were developed using a convolutional neural network and U-net architecture, respectively. The effectiveness of both MARSs were assessed through visualization and by measuring SSIM and PSNR values. The SSIM and PSNR values were statistically analyzed using one-way analysis of variance (α=0.05).Results:Significant differences were observed in the range of artifacts produced by different thicknesses of cobalt-chromium alloys (all P<0.05), with 1 mm resulting in the least artifacts. The SSIM values for specimens with thicknesses of 1.0 mm, 1.5 mm, and 2.0 mm were 0.916±0.019, 0.873±0.010, and 0.833±0.010, respectively ( F=447.89, P<0.001). The corresponding PSNR values were 20.834±1.176, 17.002±0.427, and 14.673±0.429, respectively ( F=796.51, P<0.001). After applying CNN-MARS and U-net-MARS to artifact removal, the SSIM and PSNR values significantly increased for images with the same thickness of metal (both P<0.05). When using the CNN-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.938±0.023, 0.930±0.029, and 0.928±0.020 ( F=2.22, P=0.112), while the PSNR values were 30.938±1.495, 30.578±2.154 and 30.553±2.355 ( F=0.54, P=0.585). When using the U-net-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.930±0.024, 0.932±0.017 and 0.930±0.012 ( F=0.24, P=0.788), and the PSNR values were 30.291±0.934, 30.351±1.002 and 30.271±1.143 ( F=0.07, P=0.929). No significant differences were found in SSIM and PSNR values after artifact removal using CNN-MARS and U-net-MARS for different thicknesses of cobalt-chromium alloys (all P>0.05). Visualization demonstrated a high degree of similarity between the images before and after artifact removal using both MARSs. However, CNN-MARS displayed clearer metal edges and preserved more tissue details when compared with U-net-MARS. Conclusions:Both the CNN-MARS and U-net-MARS models developed in this study effectively remove the metal artifacts and enhance the image quality. CNN-MARS exhibited an advantage in restoring tissue structure information around the artifacts compared to U-net-MARS.
2.Mitigating metal artifacts from cobalt-chromium alloy crowns in cone-beam CT images through deep learning techniques
Linghui JIA ; Honglei LIN ; Songwei ZHENG ; Xiujiao LIN ; Dong ZHANG ; Hao YU
Chinese Journal of Stomatology 2024;59(1):71-79
Objective:To develop and evaluate metal artifact removal systems (MARS) based on deep learning to assess their effectiveness in removing artifacts caused by different thicknesses of metals in cone-beam CT (CBCT) images.Methods:A full-mouth standard model (60 mm×75 mm×110 mm) was three-dimensional (3D) printed using photosensitive resin. The model included a removable and replaceable target tooth position where cobalt-chromium alloy crowns with varying thicknesses were inserted to generate matched CBCT images. The artifacts resulting from cobalt-chromium alloys with different thicknesses were evaluated using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). CNN-MARS and U-net-MARS were developed using a convolutional neural network and U-net architecture, respectively. The effectiveness of both MARSs were assessed through visualization and by measuring SSIM and PSNR values. The SSIM and PSNR values were statistically analyzed using one-way analysis of variance (α=0.05).Results:Significant differences were observed in the range of artifacts produced by different thicknesses of cobalt-chromium alloys (all P<0.05), with 1 mm resulting in the least artifacts. The SSIM values for specimens with thicknesses of 1.0, 1.5, and 2.0 mm were 0.916±0.019, 0.873±0.010, and 0.833±0.010, respectively ( F=447.89, P<0.001). The corresponding PSNR values were 20.834±1.176, 17.002±0.427, and 14.673±0.429, respectively ( F=796.51, P<0.001). After applying CNN-MARS and U-net-MARS to artifact removal, the SSIM and PSNR values significantly increased for images with the same thickness of metal (both P<0.05). When using the CNN-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.938±0.023, 0.930±0.029, and 0.928±0.020 ( F=2.22, P=0.112), while the PSNR values were 30.938±1.495, 30.578±2.154 and 30.553±2.355 ( F=0.54, P=0.585). When using the U-net-MARS for artifact removal, the SSIM values for 1.0, 1.5 and 2.0 mm were 0.930±0.024, 0.932±0.017 and 0.930±0.012 ( F=0.24, P=0.788), and the PSNR values were 30.291±0.934, 30.351±1.002 and 30.271±1.143 ( F=0.07, P=0.929). No significant differences were found in SSIM and PSNR values after artifact removal using CNN-MARS and U-net-MARS for different thicknesses of cobalt-chromium alloys (all P>0.05). Visualization demonstrated a high degree of similarity between the images before and after artifact removal using both MARS. However, CNN-MARS displayed clearer metal edges and preserved more tissue details when compared with U-net-MARS. Conclusions:Both the CNN-MARS and U-net-MARS models developed in this study effectively remove the metal artifacts and enhance the image quality. CNN-MARS exhibited an advantage in restoring tissue structure information around the artifacts compared to U-net-MARS.
3.Analysis of satisfaction evaluation and influencing factors of " Internet plus" family doctor services among contracted residents
Zixin LI ; Jianwei WANG ; Xuedan CUI ; Honglei GONG ; Xiaoqin WANG ; Chengliang YIN ; Qianqian YU
Chinese Journal of Hospital Administration 2024;40(9):687-693
Objective:To understand the satisfaction evaluation of contracted residents with " Internet plus" family doctor services and to explore its influencing factors.Methods:From November to December 2021, a stratified random sampling method was used to select 360 contracted residents who had utilized " Internet plus" family doctor services from community health service centers or township health clinics in various counties, cities, or districts of a city in Shandong Province for on-site questionnaire surveys. The purpose was to understand their awareness and satisfaction with the " Internet plus" family doctor services. At the same time, key informant interviews were conducted with contracted residents according to the principle of intensity sampling and information saturation, to collect their opinions and suggestions on the implementation process and model construction of " Internet plus" family doctor services. Descriptive analysis was performed on the data, and a binary logistic regression model was used to analyze the factors affecting the satisfaction of contracted residents with " Internet plus" family doctor services.Results:352 valid questionnaires were obtained. Among the respondents, 108 (30.6%) were very familiar or relatively familiar with the " Internet plus" family doctor service policy, and 251 (71.3%) expressed a high level of satisfaction with the overall " Internet plus" family doctor service. Gender, monthly income status, frequency of participation in health education activities, and satisfaction with the doctor′s daily service attitude, medical technical level, medical service charge level, and the level of communication between the service team and family members were factors affecting the satisfaction of contracted residents with " Internet plus" family doctor services ( P<0.05). Interview results showed that 38 people (95.0%) believed that there were issues with the current implementation of " Internet plus" family doctor services in China, such as the lack of an effective policy support environment, the need to improve the publicity and mobilization effects of contracting institutions, poor service cognition levels among the population, concerns about service quality, misunderstandings about internet-related concepts, network " panic" caused by electronic fraud phenomena, and cultural level differences among the elderly that limited the use of services. Conclusions:The overall satisfaction of contracted residents with the " Internet plus" family doctor services was relatively good. Various factors affected the satisfaction evaluation of contracted residents. It is important to focus on the differences in service psychological perception among contracted residents with different demographic characteristics, strengthen the construction of service teams and service platforms, and improve the public′s cognition and participation in " Internet plus" family doctor services to promote the continuous development of " Internet plus" family doctor services.
4.Continuation, reduction, or withdrawal of tofacitinib in patients with rheumatoid arthritis achieving sustained disease control: a multicenter, open-label, randomized controlled trial.
Mengyan WANG ; Yu XUE ; Fang DU ; Lili MA ; Liang-Jing LU ; Lindi JIANG ; Yi-Li TAO ; Chengde YANG ; Hui SHI ; Honglei LIU ; Xiaobing CHENG ; Junna YE ; Yutong SU ; Dongbao ZHAO ; Sheng-Ming DAI ; Jialin TENG ; Qiongyi HU
Chinese Medical Journal 2023;136(3):331-340
BACKGROUND:
Rheumatoid arthritis (RA), a chronic systemic autoimmune disease, is characterized by synovitis and progressive damage to the bone and cartilage of the joints, leading to disability and reduced quality of life. This study was a randomized clinical trial comparing the outcomes between withdrawal and dose reduction of tofacitinib in patients with RA who achieved sustained disease control.
METHODS:
The study was designed as a multicenter, open-label, randomized controlled trial. Eligible patients who were taking tofacitinib (5 mg twice daily) and had achieved sustained RA remission or low disease activity (disease activity score in 28 joints [DAS28] ≤3.2) for at least 3 months were enrolled at six centers in Shanghai, China. Patients were randomly assigned (1:1:1) to one of three treatment groups: continuation of tofacitinib (5 mg twice daily); reduction in tofacitinib dose (5 mg daily); and withdrawal of tofacitinib. Efficacy and safety were assessed up to 6 months.
RESULTS:
Overall, 122 eligible patients were enrolled, with 41 in the continuation group, 42 in the dose-reduction group, and 39 in the withdrawal group. After 6 months, the percentage of patients with a DAS28-erythrocyte sedimentation rate (ESR) of <3.2 was significantly lower in the withdrawal group than that in the reduction and continuation groups (20.5%, 64.3%, and 95.1%, respectively; P < 0.0001 for both comparisons). The average flare-free time was 5.8 months for the continuation group, 4.7 months for the dose reduction group, and 2.4 months for the withdrawal group.
CONCLUSION:
Withdrawal of tofacitinib in patients with RA with stable disease control resulted in a rapid and significant loss of efficacy, while standard or reduced doses of tofacitinib maintained a favorable state.
TRIAL REGISTRATION
Chictr.org, ChiCTR2000039799.
Humans
;
Quality of Life
;
China
;
Arthritis, Rheumatoid/drug therapy*
;
Piperidines/therapeutic use*
;
Treatment Outcome
;
Antirheumatic Agents/therapeutic use*
;
Pyrroles/therapeutic use*
5.Reference Intervals for Thyroid-Associated Hormones and the Prevalence of Thyroid Diseases in the Chinese Population
Yutong ZOU ; Danchen WANG ; Xinqi CHENG ; Chaochao MA ; Songbai LIN ; Yingying HU ; Songlin YU ; Liangyu XIA ; Honglei LI ; Yicong YIN ; Huaicheng LIU ; Dianxi ZHANG ; Kui ZHANG ; Xiaolan LIAN ; Tengda XU ; Ling QIU
Annals of Laboratory Medicine 2021;41(1):77-85
Background:
Thyroid diseases are highly prevalent worldwide, but their diagnosis remains a challenge. We established reference intervals (RIs) for thyroid-associated hormones and evaluated the prevalence of thyroid diseases in China.
Methods:
After excluding outliers based on the results of ultrasound screening, thyroid antibody tests, and the Tukey method, the medical records of 20,303 euthyroid adults, who visited the Department of Health Care at Peking Union Medical College Hospital from January 2014 to December 2018, were analyzed. Thyroid-associated hormones were measured by the Siemens Advia Centaur XP analyzer. The RIs for thyroid-associated hormones were calculated according to the CLSI C28-A3 guidelines, and were compared with the RIs provided by Siemens. The prevalence of thyroid diseases over the five years was evaluated and compared using the chi-square test.
Results:
The RIs for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), total thyroxine (TT4), and total triiodothyronine (TT3) were 0.71–4.92 mIU/L, 12.2–20.1 pmol/L, 3.9–6.0 pmol/L, 65.6–135.1 nmol/L, and 1.2–2.2 nmol/L, respectively. The RIs of all hormones except TT4 differed significantly between males and females. The RIs of TSH increased with increasing age. The prevalence of overt hypothyroidism, overt hyperthyroidism, subclinical hypothyroidism, and subclinical hyperthyroidism was 0.5% and 0.8%, 0.2% and 0.6%, 3.8% and 6.1%, and 3.3% and 4.7% in males and females, respectively, which differed from those provided by Siemens.
Conclusions
Sex-specific RIs were established for thyroid-associated hormones, and the prevalence of thyroid diseases was determined in the Chinese population.
6.Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI
Yu ZHANG ; Woocheol KWON ; Ho Yun LEE ; Sung Min KO ; Sang-Ha KIM ; Won-Yeon LEE ; Suk Joong YONG ; Soon-Hee JUNG ; Chun Sung BYUN ; JunHyeok LEE ; Honglei YANG ; Junhee HAN ; Jeanne B. ACKMAN
Korean Journal of Radiology 2021;22(5):829-839
Objective:
To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura.
Materials and Methods:
Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed.Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT).
Results:
At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI.
Conclusion
The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.
7.Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI
Yu ZHANG ; Woocheol KWON ; Ho Yun LEE ; Sung Min KO ; Sang-Ha KIM ; Won-Yeon LEE ; Suk Joong YONG ; Soon-Hee JUNG ; Chun Sung BYUN ; JunHyeok LEE ; Honglei YANG ; Junhee HAN ; Jeanne B. ACKMAN
Korean Journal of Radiology 2021;22(5):829-839
Objective:
To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura.
Materials and Methods:
Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed.Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT).
Results:
At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI.
Conclusion
The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.
8.Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement
Songlin YU ; Weiyan ZHOU ; Xinqi CHENG ; Qinghui MENG ; Honglei LI ; Li'an HOU ; Jun LU ; Shaowei XIE ; Qian CHENG ; Chuanbao ZHANG ; Ling QIU
Annals of Laboratory Medicine 2019;39(4):381-387
BACKGROUND: Accurate serum total thyroxine (TT4) measurement is important for thyroid disorder diagnosis and management. We compared the performance of six automated immunoassays with that of isotope-diluted liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) as the reference method. We also evaluated the correlation of thyroid stimulating hormone (TSH) with TT4 measured by ID-LC-MS/MS and immunoassays. METHODS: Serum was collected from 156 patients between October 2015 and January 2016. TT4 was measured by immunoassays from Abbott (Architect), Siemens (ADVIA Centaur XP), Roche (E601), Beckman-Coulter (Dxi800), Autobio (Autolumo A2000), and Mindray (CL-1000i), and by ID-LC-MS/MS. Results were analyzed using Passing-Bablok regression and Bland-Altman plots. Minimum requirements based on biological variation were as follows: a mean bias of ≤4.5% and total imprecision (CV) of ≤3.7%. RESULTS: All immunoassays showed a correlation >0.945 with ID-LC-MS/MS; however, the slope of the Passing-Bablok regression line varied from 0.886 (Mindray) to 1.23 (Siemens) and the intercept from −12.8 (Siemens) to 4.61 (Mindray). Only Autobio, Beckman-Coulter, and Roche included the value of one in the 95% confidence interval for slope. The mean bias ranged from −10.8% (Abbott) to 9.0% (Siemens), with the lowest value noted for Roche (3.5%) and the highest for Abbott (−10.8%). Only Abbott and Roche showed within-run and total CV ≤3.7%. CONCLUSIONS: Though all immunoassays correlated strongly with ID-LC-MS/MS, most did not meet the minimum clinical requirement. Laboratories and immunoassay manufacturers must be aware of these limitations.
Bias (Epidemiology)
;
Diagnosis
;
Humans
;
Immunoassay
;
Mass Spectrometry
;
Methods
;
Thyroid Gland
;
Thyrotropin
;
Thyroxine
9. Disinfection efficacy of peracetic acid disinfectant (type Ⅲ) on gastrointestinal endoscopy
Jiaoyang GU ; Lan LIU ; Yu XIN ; Jingmin REN ; Li WANG ; Nan ZHANG ; Honglei WU ; Xingfeng LIN ; Jianqiang GUO
Chinese Journal of Digestive Endoscopy 2019;36(10):741-745
Objective:
To evaluate the disinfection efficacy of peracetic acid disinfectant (type Ⅲ ) on gastrointestinal endoscopy.
Methods:
Endoscopes were disinfected respectively by 2% glutaraldehyde (GA group) and peracetic acid disinfectant (type Ⅲ ) (PAA group) according to the process by the 2016 version of "Regulation for cleaning and disinfection technique of flexible endoscope" , and then samples were collected through biopsy channel at the specified steps. The bacterial count and pathogenic bacteria of these samples were detected. Hepatitis B virus surface antigen (HBsAg), hepatitis C virus (HCV) antibody and
10.The application of multiple end-to-side anastomosis in free anterolateral thigh perforator flap transplantation
Zhenjie MA ; Shengjun YU ; Xiao LI ; Jingning LI ; Yuan JI ; Junjie JIANG ; Honglei DOU
Chinese Journal of Microsurgery 2019;42(1):9-12
Objective To explore the clinical application effect of multiple end-to-side anastomosis in free anterolateral thigh perforator flap transplantation.Methods From January,2013 to October,2017,29 cases were applied the technology of multiple end-to-side anastomosis to the same recipient vessel in anterolateral thigh perforator flap transplantation for wound repair.Fifteen cases treated with multiple end-to-side anastomosis on flap arteries,and 2-3 arteries were anastomosed,with the average of 2.13.Nine cases were treated with venous multiple end-to-side anastomosis,and 2-4 veins were anastomosed,with the average of 3.11.Five cases treated with arterial and venous multiple end-to-side anastomosis,and 4-6 vessels were anastomosed,with the average of 5.20.Distribution of wounds:10 cases with hands and wrists wounded,15 cases with forearms and elbow joints wounded,and 4 cases with lower legs and feet wounded.The soft tissue defect size was 5 cm×13 cm-11 cm×27 cm,and the flap area was 6 cm× 15 cm-12 cm×29 cm.Postoperative followed-up was performed every 3-6 months to review flap survival.Results All flaps of 29 cases survived.Venous congestion occurred in 2 flaps within 48 h after the operation,among which,1 was overcomed after released the dressing and sutures,and the other underwent surgical exploration.The venous end-to-side anastomotic stomas were unobstructed,and hematoma was formed.After the hematoma compression was removed,circulation was recovered and the flap survived.With followed-up for 6 months to 2.5 years,both donor site and recipient site of the flaps healed well and the injured distal limbs had no hemodynamic disorder.Conclusion The application of multiple end-to-side anastomosis to the same recipient vessel for free transplantation of anterolateral thigh perforator flaps is safe and reliable.