1.Study on HPLC fingerprint and quantitative analysis of multi-components by single-marker content determination method for Shechuan naolitong granules
Xiaoyan ZHANG ; Kairu DING ; Hong ZHANG ; Wenbing ZHI ; Shengnan JIANG ; Zongren XU ; Ni CUI ; Xiangfeng WEI ; Yang LIU
China Pharmacy 2025;36(19):2409-2414
		                        		
		                        			
		                        			OBJECTIVE To provide a reference for optimizing and promoting the quality standards of Shechuan naolitong granules. METHODS Fifteen batches of Shechuan naolitong granules were used as samples to establish HPLC fingerprints using the Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine (2012 edition). Similarity evaluation and common peak identification were performed, and orthogonal partial least squares discriminant analysis (OPLS-DA) was used to assess quality differences among different batches and to screen quality differential components. Using salvianolic acid B(SAB) as the internal reference, quantitative analysis of multi-components by single-marker (QAMS) was developed to simultaneously determine geniposidic acid (GA), chlorogenic acid (CA), vaccarin (VA), ferulic acid (FA) and senkyunolide I (SI). The results were compared with those obtained by the external standard method. RESULTS A total of 13 common peaks were identified in the HPLC fingerprints of 15 batches of samples, and the similarities of the spectra were all above 0.96. Seven chromatographic peaks were identified as GA (peak 3), CA (peak 6), VA (peak 8), FA (peak 9), SI (peak 11), SAB(peak 12) and TA(peak 13). OPLS-DA indicated that the differential quality markers among 15 batches were peaks 5, 11 (SI), and 12 (SAB).Using SAB as the internal reference, the relative correction factors for GA, CA, VA, FA and SI were calculated as 1.058 4, 0.594 3, 0.643 3, 0.342 7 and 0.262 8, respectively. The mean content of GA, CA, VA, FA, SI and SAB across the 15 batches of samples were 0.155 0, 0.085 4, 0.140 3, 0.071 8, 0.072 7, 1.276 3 mg/g, respectively, showing no significant difference compared with the ESM (P>0.05). CONCLUSIONS The established HPLC fingerprint and QAMS are simple, efficient and economical, providing a reference for the quality control and further development of Shechuan naolitong granules.
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7. Exploring mechanism of hypolipidemic effect of total Ligustrum robustum (Roxb. ) Blume on hyperlipidemic golden hamsters based on intestinal flora
Chen-Xi XU ; Rui-Le PAN ; Meng-Chen DONG ; Zhi-Hong YANG ; Xiao-Ya LI ; Wen JIN ; Run-Mei YANG
Chinese Pharmacological Bulletin 2024;40(3):476-483
		                        		
		                        			
		                        			 Aim To evaluate the hypolipidemic effect of the total phenylpropanoid glycosides extracted from Ligustrum robustum (Roxb.) Blume (LRTPG) on hyperlipidemic golden hamsters and explore its regulatory effect on intestinal flora. Methods Sixty hamsters were randomly divided into a control group, a model group, a positive drug group, LRTPG-L group, LRTPG-M group, and LRTPG-H group. After the successful induction of the model by high-fat diet, the animals were continuously administered for four weeks, and their blood lipids and liver lipids were detected. The formed feces from the colorectal region of the hamsters in the control group, model group and LRTPG-H group were collected for 16S rDNA sequencing. Results LRTPG reduced serum TG, TC, LDL-C and liver TG, TC concentrations significantly in hyperlipidemic hamsters. The results of the intestinal microbiota sequencing showed that compared to the control group, LRTPG significantly decreased the relative abundance of the phylum Firmicutes and increased the relative abundance of the phylum Bacteroidetes and Verrucomicrobia (P < 0.01) at the phylum level. At the family level, LRTPG significantly increased the relative abundance of Christensenellaceae, Peptococcaceae, and Verrucomicrobiaceae (P < 0.05 or P < 0.01). At the genus level, LRTPG significantly increased the relative abundance of Oscillospira, Oscillibacter, Flavonifractor and Akkermansiaceae (P < 0.05 or P < 0.01). These changes in the flora were beneficial to the hypolipidemic effect of LRTPG. Conclusion LRTPG may exert its hypolipidemic effect by improving the intestinal flora disorder caused by a high-fat diet in golden hamsters. 
		                        		
		                        		
		                        		
		                        	
		                				8.Systematic characterization and identification of the chemical constituents of the Schisandra chinensis  decoction based on a hybrid scanning technique of UHPLC/IM-QTOF-MS
		                			
		                			Li-li HONG ; Hong-da WANG ; Xiao-yan XU ; Wan-di HU ; Jing-yuan LIU ; Xiao-ying WANG ; Xiu-mei GAO ; Wen-zhi YANG
Acta Pharmaceutica Sinica 2024;59(3):678-692
		                        		
		                        			
		                        			 italic>Schisandra chinensis is a traditional Chinese medicine with the functions of reinforcing deficiency, strengthening, and inducing astringency, appliable to treat the chronic cough and deficiency in breath, palpitation, and insomnia, 
		                        		
		                        	
9.Epimedin B exhibits pigmentation by increasing tyrosinase family proteins expression,activity,and stability
Chen HONG ; Yifan ZHANG ; Lili YANG ; Haoyang XU ; Kang CHENG ; Zhi LV ; Kaixian CHEN ; Yiming LI ; Huali WU
Journal of Pharmaceutical Analysis 2024;14(1):69-85
		                        		
		                        			
		                        			Epimedin B(EB)is one of the main flavonoid ingredients present in Epimedium brevicornum Maxim.,a traditional herb widely used in China.Our previous study showed that EB was a stronger inducer of melanogenesis and an activator of tyrosinase(TYR).However,the role of EB in melanogenesis and the mechanism underlying the regulation remain unclear.Herein,as an extension to our previous investi-gation,we provide comprehensive evidence of EB-induced pigmentation in vivo and in vitro and eluci-date the melanogenesis mechanism by assessing its effects on the TYR family of proteins(TYRs)in terms of expression,activity,and stability.The results showed that EB increased TYRs expression through microphthalmia-associated transcription factor-mediated p-Akt(referred to as protein kinase B(PKB))/glycogen synthase kinase 3β(GSK3β)/β-catenin,p-p70 S6 kinase cascades,and protein 38(p38)/mitogen-activated protein(MAP)kinase(MAPK)and extracellular regulated protein kinases(ERK)/MAPK pathways,after which EB increased the number of melanosomes and promoted their maturation for melanogenesis in melanoma cells and human primary melanocytes/skin tissues.Furthermore,EB exerted repigmentation by stimulating TYR activity in hydroquinone-and N-phenylthiourea-induced TYR inhibitive models,including melanoma cells,zebrafish,and mice.Finally,EB ameliorated monobenzone-induced depigmentation in vitro and in vivo through the enhancement of TYRs stability by inhibiting TYR misfolding,TYR-related protein 1 formation,and retention in the endoplasmic reticulum and then by downregulating the ubiquitination and proteolysis processes.These data conclude that EB can target TYRs and alter their expression,activity,and stability,thus stimulating their pigmentation function,which might provide a novel rational strategy for hypopigmentation treatment in the pharmaceutical and cosmetic industries.
		                        		
		                        		
		                        		
		                        	
10.Effects of esketamine combined with sufentanil on postoperative analgesia and depression after hip arthroplasty
Jun-Jun HE ; Hong WANG ; Yuan-Yuan HU ; Lan XU ; Jing-Jing WU ; Qun CHEN ; Zhi-Peng DONG ; Li-Li ZHONG
Journal of Regional Anatomy and Operative Surgery 2024;33(3):268-271
		                        		
		                        			
		                        			Objective To evaluate the effects of ketamine combined with sufentanil on postoperative analgesia and depression in patients undergoing hip arthroplasty.Methods A total of 60 patients who underwent elective hip arthroplasty were selected and divided into the S group,the SK1 group and the SK2 group according to the patient-controlled intravenous analgesia regimen,with 20 cases in each group.Patients in the S group were received 2 μg/kg of sufentanil for postoperative analgesia,patients in the SK1 group were received 1 mg/kg of esketamine and 2 μg/kg of sufentanil for postoperative analgesia,and patients in the SK2 group were received 2 mg/kg of esketamine and 2 μg/kg of sufentanil for postoperative analgesia.At 1,4,24,and 48 hours after surgery,the analgesic effect of patients was evaluated using the numeric rating scale(NRS),and the sedation effect of patients was evaluated using the Ramsay sedation score.Depression of patients before and 48 hours after surgery was assessed by self-rating depression scale(SDS).The adverse reactions such as nausea and vomiting,dizziness and headache,respiratory depression,and mental symptoms within 48 hours after surgery of patients were recorded.Results The NRS scores 1,4,and 24 hours after surgery of patients in the SK1 group and the SK2 group were lower than those in the S group(P<0.05);there was no statistically significant difference in the NRS scores 48 hours after surgery of patients among the three groups(P>0.05);there was no statistically significant difference in the NRS scores at different postoperative points of patients between the SK1 and SK2 groups(P>0.05).The SDS scores 48 hours after surgery of patients in each group were lower than those before surgery(P<0.05).There was no statistically significant difference in the Ramsay scores at different postoperative points of patients among the three groups(P>0.05).The incidence of adverse reactions 48 hours after surgery in the SK2 group was higher than those in the S group and the SK1 group(P<0.05).Conclusion Using 1 mg/kg of esketamine combined with 2 μg/kg of sufentanil after hip arthroplasty has a good analgesic effect without obvious increase of adverse reactions or significant effect on improving depression of patients.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail