1.Factors influencing repeat blood donor lapsing in Guangzhou: based on the zero-inflated poisson regression model
Rongrong KE ; Guiyun XIE ; Xiaoxiao ZHENG ; Yingying XU ; Xiaochun HONG ; Shijie LI ; Yongshi DENG ; Jinyu SHEN ; Jinyan CHEN ; Jian OUYANG
Chinese Journal of Blood Transfusion 2025;38(1):73-78
[Objective] To analyze the influencing factors of repeat blood donor lapsing using a zero-inflated poisson regression model (ZIP). [Methods] The blood donation behavior of 12 498 whole blood donors from 2020 was tracked until December 31, 2023. The factors influencing the frequency of blood donations in a given year was analyzed using ZIP, and donors with 0 blood donation in that year were considered to have lapsed. The changes in relevant influencing factors associated with each blood donation were measured and modeled for analysis. [Results] The zero-inflated part of ZIP showed that the risk of lapsing of male blood donors was 2.24 times that of female blood donors (OR 95% CI:1.864-2.696, P<0.001); the risk of lapsing of the 35-44 age group and over 45 age group was respectively 40% (OR 95% CI:0.455-0.790, P<0.001) and 61%(OR 95% CI:0.268-0.578, P<0.001) lower than that of the under 25 age group; the risk of lapsing for those who have donated blood twice and ≥3 times was respectively 50% (OR 95% CI:0.405-0.609, P<0.001) and 81% (OR 95% CI:0.154-0.225, P<0.001) lower than that of first-time donors; the risk of lapsing of those with junior high or high school education was 1.2 times that of those with a college degree or higher (OR 95% CI:1.033-1.384, P<0.05); the risk of lapsing for the divorced group was 2.02 times that of the married group (OR 95% CI:1.445-2.820, P<0.001); the risk of lapsing for those with an income (Yuan) of 10 000 to 50 000, 50 000 to 100 000 and more than 100 000 was respectively 0.67 (OR 95% CI:0.552-0.818, P<0.001), 0.72 (OR 95% CI:0.591-0.884, P=0.002) and 0.67 (OR 95% CI:0.535-0.834, P<0.001) times that of those with an income (Yuan) of less than 10 000. The results of the Poisson part are consistent with the results of the zero-inflated part in terms of age and education level. [Conclusion] Blood donor lapsing is overall related to factors such as gender, age, donation frequency, education, marital status and family income. It's essential to care for those blood donors prone to lapse to retain more regular blood donors.
2.Three new gallic acid sugaresters from Elaeagnus oxycarpa Schlechtend leaves and their antioxidant and tyrosinase inhibitory activities
Feng-zhen CUI ; Jian-hong FU ; Guo-yan XU ; AYEKABAYR·EKBAYR ; Chang-da MA
Acta Pharmaceutica Sinica 2025;60(2):434-441
Five compounds were isolated and purified from the water extract of
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8. Effects of metabolites of eicosapentaenoic acid on promoting transdifferentiation of pancreatic OL cells into pancreatic β cells
Chao-Feng XING ; Min-Yi TANG ; Qi-Hua XU ; Shuai WANG ; Zong-Meng ZHANG ; Zi-Jian ZHAO ; Yun-Pin MU ; Fang-Hong LI
Chinese Pharmacological Bulletin 2024;40(1):31-38
Aim To investigate the role of metabolites of eicosapentaenoic acid (EPA) in promoting the transdifferentiation of pancreatic α cells to β cells. Methods Male C57BL/6J mice were injected intraperitoneally with 60 mg/kg streptozocin (STZ) for five consecutive days to establish a type 1 diabetes (T1DM) mouse model. After two weeks, they were randomly divided into model groups and 97% EPA diet intervention group, 75% fish oil (50% EPA +25% DHA) diet intervention group, and random blood glucose was detected every week; after the model expired, the regeneration of pancreatic β cells in mouse pancreas was observed by immunofluorescence staining. The islets of mice (obtained by crossing GCG
9. Histamine 1 receptor agonist inhibits LPS-induced immune responses in astrocytes via Akt/NF-KB signaling pathway
Jia-Wen XU ; Jia-Hong SHEN ; Yu-Xin WEN ; Jian-Liang SUN
Chinese Pharmacological Bulletin 2024;40(2):317-323
Aim To investigate the effect of histamine H, receptor (HjR) on the immune responses in astrocytes induced by lipopolysaccharide (LPS) and the regulatory mechanism of its signaling pathway. Methods LPS was used to establish an in vitro astrocyte inflammation model. Rat primary astrocytes were divided into the control group, LPS group, LPS + Hj R agonist group (2-pyridylethlamine, Pyri), and HjR agonist group. Astrocytes were treated with Pyri 100 p,mol • L~ for 1 h, then stimulated with LPS at 100 p,g • L~ for 24 h. Cell viability was measured using the CCK-8 assay. The expression of GFAP and HjR was detected by immunofluorescence. Glial morphological changes were observed under a microscope. The levels of proinflammatory mediators (TNF-a and IL-6) were detected by ELISA. The protein expressions of p-Akt, Akt, p-NF-KB p65, and NF-KB p65 were detected by Western blot. Results Compared with the control group, more activated astrocytes with fewer cell processes and branches were observed in the LPS group. Besides, LPS enhanced the GFAP expression level, reduced the H,R expression level and stimulated the production of TNF-a and IL-6 from astrocytes. Pre treatment with Pyri for 1 h ameliorated the glial morphological changes stimulated by LPS, inhibited LPS-induced upregulation of GFAP level and the inflammatory factors secretion. In addition, LPS stimulated astrocytes showed a higher phosphorylation of Akt and NF-KB p65, which was also ameliorated by Pyri. Conclusions H, R agonist can inhibit LPS-induced astrocyte activation and inflammatory factor secretion, and the Akt/NF-KB signaling pathway may be an important pathway for the involvement of H,R in immune regulation.
10.Research progress on the role of cytochrome P450 in plant sesquiterpene biosynthesis
Shi-xi GAO ; Mei RONG ; Jun-xiang PENG ; Yan-hong XU ; Jian-he WEI
Acta Pharmaceutica Sinica 2024;59(2):313-321
Sesquiterpenes are natural terpenoids with 15 carbon atoms in the basic skeleton, which mainly exist in plant volatile oil and have important physiological and medicinal value. Cytochrome P450 (CYP450) is a kind of monooxygenase encoded by supergene family, which is one of the largest gene families in plants. It is involved in the synthesis and metabolism of terpenoids, alkaloids and other secondary metabolites. In the process of terpene biosynthesis, CYP450 participates in the post-modification stage of terpenes by introducing functional groups such as hydroxyl, carboxyl and carbonyl, which plays an important role in enriching the diversity of terpenes. The CYP450 enzymes involved in sesquiterpene synthesis and their substrate catalytic specificity mechanisms have been partially investigated. In this paper, the biosynthetic pathway of plant sesquiterpenes, the structure and classification of CYP450 enzymes were briefly introduced, and the CYP450 enzymes involved in sesquiterpene biosynthesis were summarized, in order to provide a reference for intensive study of the role of CYP450 enzymes in the synthesis of sesquiterpenoids.

Result Analysis
Print
Save
E-mail