1.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
		                        		
		                        			
		                        			Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
		                        		
		                        		
		                        		
		                        	
2.Pure echocardiography-guided implantation and localization of transcatheter left ventricular assist pump: A report of two cases
Da ZHU ; Shouzheng WANG ; Wenbin OUYANG ; Hong QIU ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(11):1690-1693
		                        		
		                        			
		                        			Transcatheter left ventricular assist pump (LVAP) is widely used in cardiogenic shock, post-circulatory hypoperfusion syndrome and high-risk percutaneous coronary intervention (PCI), and its application scenarios cover various complex environments such as ICU, operating room, emergency department and catheterization room. It is important to quickly and accurately implant the transcatheter LVAP and monitor its position in real time. This paper reported 2 male patients with high-risk PCI, aged 47 and 45 years, both with triple coronary artery disease and reduced ejection fraction (<35%). The domestically produced transcatheter LVAP was implanted using an echocardiography guidance technology system, and PCI treatment was performed under the assistance of the interventional pump. The operation was smooth, and the interventional pump assisted for 1 h in 2 patients, and the pump was successfully removed. There were no obvious complications related to the pump and PCI after the operation, and the patients were discharged smoothly.
		                        		
		                        		
		                        		
		                        	
3.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
		                        		
		                        			
		                        			Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
		                        		
		                        		
		                        		
		                        	
4.Short term prognosis comparison of transcatheter aortic valve replacement through the femoral artery for patients with pure aortic valve regurgitation of different annulus girths
Nan-Chao HONG ; Sha-Sha CHEN ; Yuan ZHANG ; Xiao-Chun ZHANG ; Wen-Zhi PAN ; Da-Xin ZHOU ; Jun-Bo GE
Chinese Journal of Interventional Cardiology 2024;32(5):244-249
		                        		
		                        			
		                        			Objective To evaluate and compare the success rate and short-term clinical prognosis of transfemoral transcatheter aortic valve replacement(TF-TAVR)for patients with pure aortic regurgitation(PAR)of different annulus sizes.Methods This study is a single center retrospective study,selecting symptomatic PAR patients who received TF-TAVR treatment at Zhongshan Hospital Fudan University from September 2019 to September 2023.Based on preoperative CT results,all patients were divided into three groups:Group A(aortic annulus circumference<80 mm),Group B(80 mm≤aortic annulus circumference<85 mm),and Group C(aortic annulus circumference≥ 85 mm).The primary endpoint was success rate and 30d all-cause mortality,while the secondary endpoint was TAVR related complications.Results A total of 61 PAR patients were included in this study,including 27 in Group A,21 in Group B,and 13 in Group C.The overall success rate is 82.0%,and the 30 d all-cause mortality rate is 3.3%.The success rate of Group C patients was significantly lower(P=0.012),with higher rates of conversion to surgery and valve-in-valve implantation(P=0.022 and P=0.040).In terms of secondary endpoint events,there were no significant differences among the three groups in major bleeding events,major vascular complications,stroke,myocardial infarction,newly developed atrial fibrillation,implantation of new pacemakers,coronary artery occlusion,and postoperative moderate to severe perivalvular leakage(all P>0.05).Conclusions The circumference of the aortic valve annulus is a key factor affecting the success rate of TF-TAVR in PAR,and PAR patients with an aortic valve annulus circumference less than 85mm may be more suitable for TF-TAVR.
		                        		
		                        		
		                        		
		                        	
5.The Uptake and Distribution Evidence of Nano-and Microplastics in vivo after a Single High Dose of Oral Exposure
Tao HONG ; Wei SUN ; Yuan DENG ; Da Jian LYU ; Hong Cui JIN ; Long Ying BAI ; Jun NA ; Rui ZHANG ; Yuan GAO ; Wei Guo PAN ; Sen Zuo YANG ; Jun Ling YAN
Biomedical and Environmental Sciences 2024;37(1):31-41
		                        		
		                        			
		                        			Objective Tissue uptake and distribution of nano-/microplastics was studied at a single high dose by gavage in vivo.Methods Fluorescent microspheres (100 nm, 3 μm, and 10 μm) were given once at a dose of 200 mg/(kg·body weight). The fluorescence intensity (FI) in observed organs was measured using the IVIS Spectrum at 0.5, 1, 2, and 4 h after administration. Histopathology was performed to corroborate these findings.Results In the 100 nm group, the FI of the stomach and small intestine were highest at 0.5 h, and the FI of the large intestine, excrement, lung, kidney, liver, and skeletal muscles were highest at 4 h compared with the control group (P < 0.05). In the 3 μm group, the FI only increased in the lung at 2 h (P < 0.05). In the 10 μm group, the FI increased in the large intestine and excrement at 2 h, and in the kidney at 4 h (P < 0.05). The presence of nano-/microplastics in tissues was further verified by histopathology. The peak time of nanoplastic absorption in blood was confirmed.Conclusion Nanoplastics translocated rapidly to observed organs/tissues through blood circulation;however, only small amounts of MPs could penetrate the organs.
		                        		
		                        		
		                        		
		                        	
6.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
		                        		
		                        			
		                        			Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Mitral Valve Insufficiency/etiology*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			East Asian People
		                        			;
		                        		
		                        			Heart Valve Prosthesis Implantation
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Heart Failure/etiology*
		                        			;
		                        		
		                        			Cardiac Catheterization
		                        			
		                        		
		                        	
7.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
		                        		
		                        			
		                        			Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Mitral Valve Insufficiency/etiology*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			East Asian People
		                        			;
		                        		
		                        			Heart Valve Prosthesis Implantation
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Heart Failure/etiology*
		                        			;
		                        		
		                        			Cardiac Catheterization
		                        			
		                        		
		                        	
8.Comparison of application effects of colonoscopy, fecal immunochemical test and a novel risk-adapted screening approach in colorectal cancer screening in Xuzhou population.
Yun Xin KONG ; Dong DONG ; Hong Da CHEN ; Min DAI ; Lang ZHUO ; Pei An LOU ; Ting CAI ; Si Ting CHEN ; Jian Qiang PAN ; Yi Huan GAO ; Hang LU ; Zong Mei DONG ; Hong Ying ZHAO ; Xiao Hu LUO ; Guohui CHEN
Chinese Journal of Preventive Medicine 2022;56(8):1074-1079
		                        		
		                        			
		                        			Objective: To compare the application effect of the colonoscopy, fecal immunochemical test (FIT) and novel risk-adapted screening approach in colorectal cancer screening in Xuzhou population. Methods: From May 2018 to April 2019, 4 280 subjects aged 50-74 were recruited from Gulou district, Yunlong district and Quanshan district of Xuzhou. They were randomly assigned to the colonoscopy group (n=863), FIT group (n=1 723) and novel risk-adapted screening approach group (n=1 694) according to the ratio of 1∶2∶2. For the novel risk-adapted screening approach group, after the risk assessment, high-risk subjects were invited to undergo colonoscopy and low-risk subjects were invited to undergo FIT examination. All FIT positive subjects were invited to undergo colonoscopy. Colonoscopy participation rate [(the number of colonoscopies completed/the number of colonoscopies invited to participate)×100%], detection rate of colorectal lesions [(the number of diagnosed patients/the number of colonoscopies completed)×100%], colonoscopy resource load (the number of colonoscopies completed/the number of diagnosed advanced tumors) and FIT resource load in each group were calculated and compared. Results: The age of all subjects was (61±6) years old, including 1 816 males (42.43%). There was no statistically significant difference in the socio-demographic characteristics of the subjects in different screening groups. The colonoscopy participation rate was 22.60% (195/863) in the colonoscopy group, 57.04% (77/135) in the FIT group, and 33.94% (149/439) in the novel risk-adapted screening approach group, respectively. The colonoscopy participation rate was higher in the FIT group than in the colonoscopy group and the novel risk-adapted screening approach group (P<0.001). The colonoscopy participation rate of novel risk-adapted screening group was significantly higher than the colonoscopy group (P<0.001). The detection rates of advanced tumors were 6.67% (13/195), 9.09% (7/77) and 8.72% (13/149), respectively, and the difference was not statistically significant (P>0.05). The colonoscopy resource load (95%CI) was 15 (13-17) in the colonoscopy group, 11 (9-14) in the FIT group and 11 (10-13) in the novel risk-adapted screening approach group, respectively. Among them, the colonoscopy resource load of high-risk individuals in the novel risk-adapted screening approach group was 12 (9-15). FIT resource loads (95%CI) were 207 (196-218) and 88 (83-94) in the FIT group and the novel risk-adapted screening approach group. Conclusion: The combined application of risk-adapted screening approach and FIT may have a good application effect in colorectal cancer screening.
		                        		
		                        		
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Colonoscopy
		                        			;
		                        		
		                        			Colorectal Neoplasms/pathology*
		                        			;
		                        		
		                        			Early Detection of Cancer
		                        			;
		                        		
		                        			Feces
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Mass Screening
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Occult Blood
		                        			
		                        		
		                        	
9.Analysis of the whole genome traceability and transmission path simulation experiment of the local cluster COVID-19 epidemic.
Yun SONG ; Shi Dong LU ; Xiao HU ; Bi Cong WU ; Wei FAN ; Hong Xia MA ; Ying YE ; Dong Xiao LI ; Yi LI ; Bai Fan ZHANG ; Sheng ZHAO ; Hai Yan WEI ; Jing Jing PAN ; Da Cheng GUO ; Dong Yang ZHAO ; Wan Shen GUO ; Xue Yong HUANG
Chinese Journal of Preventive Medicine 2022;56(12):1795-1802
		                        		
		                        			
		                        			Objective: To trace and characterize the whole genome of SARS-CoV-2 of confirmed cases in the outbreak of COVID-19 on July 31, 2021 in Henan Province. Method: Genome-wide sequencing and comparative analysis were performed on positive nucleic acid samples of SARS-CoV-2 from 167 local cases related to the epidemic on July 31, 2021, to analyze the consistency and evolution of the whole genome sequence of virus. Results: Through high-throughput sequencing, a total of 106 cases of SARS-CoV-2 whole genome sequences were obtained. The results of genome analysis showed that the whole genome sequences of 106 cases belonged to the VOC/Delta variant strain (B.1.617.2 clade), and the whole genome sequences of 106 cases were shared with the genomes of 3 imported cases from Myanmar admitted to a hospital in Zhengzhou. On the basis of 45 nucleotide sites, 1-5 nucleotide variation sites were added, and the genome sequence was highly homologous. Conclusion: Combined with the comprehensive analysis of viral genomics, transmission path simulation experiments and epidemiology, it is determined that the local new epidemic in Henan Province is caused by imported cases in the nosocomial area, and the spillover has caused localized infection in the community. At the same time, it spills over to some provincial cities and results in localized clustered epidemics.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			COVID-19
		                        			;
		                        		
		                        			SARS-CoV-2/genetics*
		                        			;
		                        		
		                        			Genome, Viral
		                        			;
		                        		
		                        			Epidemics
		                        			;
		                        		
		                        			Phylogeny
		                        			
		                        		
		                        	
10.Efficacy of fenestrated atrial septal defect occulders on pulmonary hypertension dogs.
Li Fan YANG ; Dan Dan CHEN ; Gao Feng WANG ; Yu Liang LONG ; Qin Chun JIN ; De Hong KONG ; Wen Zhi PAN ; Li Hua GUAN ; Da Xin ZHOU ; Jun Bo GE
Chinese Journal of Cardiology 2022;50(2):166-171
		                        		
		                        			
		                        			Objective: To explore the short-term efficacy of fenestrated atrial septal defect (ASD) occulders in the treatment of pulmonary arterial hypertension (PAH). Methods: Thirty-six healthy dogs were divided into the balloon atrial septostomy (BAS)+fenestrated ASD occulders group (n=12), BAS group (n=12) and non-septostomy group (n=12). PAH was induced by intra-atrial injection of dehydrogenized monocrotaline (1.5 mg/kg) in all dogs. Animals in the BAS+fenestrated ASD occulders group underwent atrial septal puncture and fenestrated ASD occulders implantation. Animals in the BAS group underwent balloon atrial septostomy. The non-septostomy group received no surgical intervention. The hemodynamic indexes and blood N-terminal pro-B-type natriuretic peptide (NT-proBNP) of dogs were measured before modeling, 2 months after modeling, 1, 3, and 6 months after surgery, respectively. Echocardiography was performed to observe the patency of the shunt and atrial septostomy of the dogs in the BAS+fenestrated ASD occulders group and BAS group at 1, 3, and 6 months after surgery. Three dogs were sacrificed in each group at 1, 3, and 6 months after surgery, respectively. Atrial septal tissue and fenestrated ASD occulders were removed to observe the patency and endothelialization of the device. Lung tissues were obtained for hematoxylin-eosin (HE) staining to observe the inflammatory cells infiltration and the thickening and narrowing of the pulmonary arterials. Results: Among 36 dogs, 2 dogs died within 24 hours after modeling, and 34 dogs were assigned to BAS+fenestrated ASD occulders group (n=12), BAS group (n=11), and non-septostomy group (n=11). Compared with BAS group, the average right atrial pressure (mRAP) and NT-proBNP of dogs in the BAS+fenestrated ASD occulders group were significantly reduced at 3 months after surgery (P<0.05), and the cardiac output (CO) was significantly increased at 6 months after surgery, arterial oxygen saturation (SaO2) was also significantly reduced (P<0.05). Compared with non-septostomy group, dogs in the BAS+fenestrated ASD occulders group had significantly lower mRAP and NT-proBNP at 1, 3, and 6 months after surgery (P<0.05), and higher CO and lower SaO2 at 6 months after surgery (P<0.05). Compared with the non-septostomy group, the dogs in the BAS group had significantly lower mRAP and NT-proBNP at 1 month after surgery (P<0.05), and there was no significant difference on mRAP and NT-proBNP at 3 and 6 months after surgery (P>0.05). Echocardiography showed that there was a minimal right-to-left shunt in the atrial septum in the BAS group at 1 month after the surgery, and the ostomy was closed in all the dogs in the BAS group at 3 months after the surgery. There was still a clear right-to-left shunt in the dogs of BAS+fenestrated ASD occulders group. The shunt was well formed and satisfactory endothelialization was observed at 1, 3 and 6 months after surgery. The results of HE staining showed that the pulmonary arterials were significantly thickened, stenosis and collapse occurred in the non-septostomy group. Pulmonary microvascular stenosis and inflammatory cell infiltration in the pulmonary arterials were observed in the non-septostomy group. Pulmonary arterial histological results were comparable between BAS+fenestrated ASD occulders group and non-septostomy group at 6 months after surgery . Conclusions: The fenestrated ASD occulder has the advantage of maintaining the open fistula hole for a longer time compared with simple balloon dilation. The fenestrated ASD occulder can improve cardiac function, and it is safe and feasible to treat PAH in this animal model.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Atrial Septum/surgery*
		                        			;
		                        		
		                        			Cardiac Catheterization/methods*
		                        			;
		                        		
		                        			Dogs
		                        			;
		                        		
		                        			Familial Primary Pulmonary Hypertension
		                        			;
		                        		
		                        			Heart Septal Defects, Atrial/surgery*
		                        			;
		                        		
		                        			Hypertension, Pulmonary
		                        			;
		                        		
		                        			Pulmonary Arterial Hypertension
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail