1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Clinicopathological Features and Long-Term Prognostic Role of Human Epidermal Growth Factor Receptor-2 Low Expression in Chinese Patients with Early Breast Cancer:A Single-Institution Study
Qing Zi KONG ; Qun Li LIU ; Qin De HUANG ; Tong Yu WANG ; Jie Jing LI ; Zheng ZHANG ; Xi Xi WANG ; Ling Chuan LIU ; Di Ya ZHANG ; Kang Jia SHAO ; Min Yi ZHU ; Meng Yi CHEN ; Mei LIU ; Hong Wei ZHAO
Biomedical and Environmental Sciences 2024;37(5):457-470
		                        		
		                        			
		                        			Objective This study aimed to comprehensively analyze and compare the clinicopathological features and prognosis of Chinese patients with human epidermal growth factor receptor 2(HER2)-low early breast cancer(BC)and HER2-IHC0 BC. Methods Patients diagnosed with HER2-negative BC(N=999)at our institution between January 2011 and December 2015 formed our study population.Clinicopathological characteristics,association between estrogen receptor(ER)expression and HER2-low,and evolution of HER2 immunohistochemical(IHC)score were assessed.Kaplan-Meier method and log-rank test were used to compare the long-term survival outcomes(5-year follow-up)between the HER2-IHC0 and HER2-low groups. Results HER2-low BC group tended to demonstrate high expression of ER and more progesterone receptor(PgR)positivity than HER2-IHC0 BC group(P<0.001).The rate of HER2-low status increased with increasing ER expression levels(Mantel-Haenszel χ2 test,P<0.001,Pearson's R=0.159,P<0.001).Survival analysis revealed a significantly longer overall survival(OS)in HER2-low BC group than in HER2-IHC0 group(P=0.007)in the whole cohort and the hormone receptor(HR)-negative group.There were no significant differences between the two groups in terms of disease-free survival(DFS).The discordance rate of HER2 IHC scores between primary and metastatic sites was 36.84%. Conclusion HER2-low BC may not be regarded as a unique BC group in this population-based study due to similar clinicopathological features and prognostic roles.
		                        		
		                        		
		                        		
		                        	
7.Systematic identification of CRISPR off-target effects by CROss-seq.
Yan LI ; Shengyao ZHI ; Tong WU ; Hong-Xuan CHEN ; Rui KANG ; Dong-Zhao MA ; Zhou SONGYANG ; Chuan HE ; Puping LIANG ; Guan-Zheng LUO
Protein & Cell 2023;14(4):299-303
8.Research progress of button battery ingestion in children.
Feng Zhen ZHANG ; Qing Chuan DUAN ; Gui Xiang WANG ; Jing ZHAO ; Hua WANG ; Hong Bin LI ; Xin NI ; Jie ZHANG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(4):394-398
		                        		
		                        		
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Infant
		                        			;
		                        		
		                        			Esophagus
		                        			;
		                        		
		                        			Electric Power Supplies
		                        			;
		                        		
		                        			Eating
		                        			;
		                        		
		                        			Foreign Bodies
		                        			
		                        		
		                        	
9.Clinical characteristics and serious complications of esophageal button battery ingestion in the pediatric on 83 cases.
Feng Zhen ZHANG ; Qing Chuan DUAN ; Gui Xiang WANG ; Xiao Jian YANG ; Wei ZHANG ; Jing ZHAO ; Hua WANG ; Hong Bin LI ; Xin NI ; Jie ZHANG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(5):481-485
		                        		
		                        			
		                        			Objective: To analyze the clinical characteristics and complications of esophageal foreign bodies of button battery ingestion in children. Methods: A retrospective descriptive study included 83 children who were hospitalized in our hospital on account of button battery ingestion from January 2011 to December 2021. There were 50 males (60.2%) and 33 females (39.8%). The age ranged from 7.6 months to one month off 10 years, with a median age of 18 months. The data of patient demographics and time from ingestion to admission, location, symptoms, management, complications, and follow-up outcome were recorded. SPSS17.0 software was used for statistical analysis. Results: Seventy-two children (86.7%) were younger than 3 years old. The time from ingestion to admission ranged from 1 h to 2 months, with a median time of 8 h. Among the 63 children who were first diagnosed in our hospital, the most common clinical symptoms were nausea and vomiting (32 cases, 50.8%), dysphagia (31 cases, 49.2%), salivation (11 cases, 17.5%) and fever (10 cases, 15.9%). Seventy-three of 83 cases had complete preoperative diagnostic tests, and 55 cases (75.3%) were diagnosed by X-ray. In 56 cases (76.7%), the foreign badies were impacted in the upper third of esophagus. In 72 cases (86.7%), the foreign badies were removed by rigid esophagoscopy. 23 (27.7%) had serious complications, including tracheoesophageal fistula in 15 cases(TEF;65.2%), vocal cord paralysis (VCP;34.8%) in 8 cases, esophageal perforation in 3 cases (EP;13.0%), hemorrhage in 3 cases(13.0%), mediastinitis in 3 cases (13%), and periesophageal abscess in 1 case (4.3%). There were significant differences in the exposure time of foreign bodies and unwitnessed ingestion by guardians in the complications group (P<0.05). 2 cases died (2.4%)respectively due to arterial esophageal fistula bleeding and respiratory failure caused by stent displacement during the treatment of tracheoesophageal fistula. Conclusion: Accidental button battery ingestion can be life-threatening. and it mostly happens in children under 3 years old. Serious complications may happen cause of non-specific clinical manifestations and unwitnessed ingestions. Anterior and lateral chest X-ray is the first examination choice. Tracheoesophageal fistula is the most common serious complication.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Infant
		                        			;
		                        		
		                        			Child, Preschool
		                        			;
		                        		
		                        			Tracheoesophageal Fistula/etiology*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Foreign Bodies/diagnosis*
		                        			;
		                        		
		                        			Eating
		                        			
		                        		
		                        	
10.Study on pharmaceutical care model for drug-related problems in elderly patients based on comprehensive medication management review
Hui GONG ; Chen LI ; Qing SHAN ; Wei LIU ; Hong CHEN ; Chuan ZHAO ; Hui ZOU ; Zhuanqing HUANG ; Mengli CHEN
China Pharmacy 2023;34(17):2162-2166
		                        		
		                        			
		                        			OBJECTIVE To explore the pharmaceutical care model for elderly patients with drug-related problems (DRPs) based on the comprehensive medication management review (CMMR), and to observe the effect of pharmaceutical care under the model. METHODS The pharmaceutical care new model for elderly patients was established by concerning CMMR guidelines in Australia. In other words, clinical pharmacists receive medical care through referral by health practitioners and active consultation by patients or their caregivers. Visits were made by a combination of face-to-face and telephone interviews. Follow-up was carried out in the form of outpatient follow-up, telephone follow-up, appointment, and home guidance to know about the treatment of DRPs by healthcare practitioners or patients.Under this model, the occurrence status and classification of DRPs in elderly patients were studied through cross-sectional investigation. The effect of pharmaceutical care was evaluated from the aspects of hospitalization rate, adverse drug reaction (ADR) incidence,medication compliance, the number of medications, blood lipid level, etc., through self-before-after comparison. RESULTS In this study, a patient-centered, evaluation-intervention-reevaluation closed-loop pharmaceutical care model was formed. Among 317 study subjects, the average number of DRPs was 1.03 (0-7) cases. Compared before and after the intervention, the number of drug types increased from 2.00(0.00,3.00) to 2.00(1.00,3.00), but the level of low-density lipoprotein cholesterin in patients decreased from 3.48 (2.58, 4.29) mmol/L to 3.11 (2.29,3.81) mmol/L (P<0.05). There was no statistical significance in hospitalization rate, ADR incidence within or medication compliance. CONCLUSIONS CMMR-based pharmaceutical care model can effectively identify and manage the patients’ DRPs and reduce the level of blood lipid.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis