1.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
2.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
3.Inhibition of HDAC3 Promotes Psoriasis Development in Mice Through Regulating Th17
Fan XU ; Xin-Rui ZHANG ; Yang-Chen XIA ; Wen-Ting LI ; Hao CHEN ; An-Qi QIN ; Ai-Hong ZHANG ; Yi-Ran ZHU ; Feng TIAN ; Quan-Hui ZHENG
Progress in Biochemistry and Biophysics 2025;52(4):1008-1017
ObjectiveTo investigate the influence of histone deacetylase 3 (HDAC3) on the occurrence, development of psoriasis-like inflammation in mice, and the relative immune mechanisms. MethodsHealthy C57BL/6 mice aged 6-8 weeks were selected and randomly divided into 3 groups: control group (Control), psoriasis model group (IMQ), and HDAC3 inhibitor RGFP966-treated psoriasis model group (IMQ+RGFP966). One day prior to the experiment, the back hair of the mice was shaved. After a one-day stabilization period, the mice in Control group was treated with an equal amount of vaseline, while the mice in IMQ group was treated with imiquimod (62.5 mg/d) applied topically on the back to establish a psoriasis-like inflammation model. The mice in IMQ+RGFP966 group received intervention with a high dose of the HDAC3-selective inhibitor RGFP966 (30 mg/kg) based on the psoriasis-like model. All groups were treated continuously for 5 d, during which psoriasis-like inflammation symptoms (scaling, erythema, skin thickness), body weight, and mental status were observed and recorded, with photographs taken for documentation. After euthanasia, hematoxylin-eosin (HE) staining was used to assess the effect of RGFP966 on the skin tissue structure of the mice, and skin thickness was measured. The mRNA and protein expression levels of HDAC3 in skin tissues were detected using reverse transcription real-time quantitative polymerase chain reaction (RT-qPCR) and Western blot (WB), respectively. Flow cytometry was employed to analyze neutrophils in peripheral blood and lymph nodes, CD4+ T lymphocytes, CD8+ T lymphocytes in peripheral blood, and IL-17A secretion by peripheral blood CD4+ T lymphocytes. Additionally, spleen CD4+ T lymphocyte expression of HDAC3, CCR6, CCR8, and IL-17A secretion levels were analyzed. Immunohistochemistry was used to detect the localization and expression levels of HDAC3, IL-17A, and IL-10 in skin tissues. ResultsCompared with the Control group, the IMQ group exhibited significant psoriasis-like inflammation, characterized by erythema, scaling, and skin wrinkling. Compared with the IMQ group, RGFP966 exacerbated psoriasis-like inflammatory symptoms, leading to increased hyperkeratosis. The psoriasis area and severity index (PASI) skin symptom scores were higher in the IMQ group than those in the Control group, and the scores were further elevated in the IMQ+RGFP966 group compared to the IMQ group. Skin thickness measurements showed a trend of IMQ+RGFP966>IMQ>Control. The numbers of neutrophils in the blood and lymph nodes increased sequentially in the Control, IMQ, and IMQ+RGFP966 groups, with a similar trend observed for CD4+ and CD8+ T lymphocytes in the blood. In skin tissues, compared with the Control group, the mRNA and protein levels of HDAC3 decreased in the IMQ group, but RGFP966 did not further reduce these expressions. HDAC3 was primarily located in the nucleus. Compared with the Control group, the nuclear HDAC3 content decreased in the skin tissues of the IMQ group, and RGFP966 further reduced nuclear HDAC3. Compared with the Control and IMQ groups, RGFP966 treatment decreased HDAC3 expression in splenic CD4+ and CD8+ T cells. RGFP966 treatment increased the expression of CCR6 and CCR8 in splenic CD4+ T cells and enhanced IL-17A secretion by peripheral blood and splenic CD4+ T lymphocytes. Additionally, compared with the IMQ group, RGFP966 reduced IL-10 protein levels and upregulated IL-17A expression in skin tissues. ConclusionRGFP966 exacerbates psoriatic-like inflammatory responses by inhibiting HDAC3, increasing the secretion of the cytokine IL-17A, and upregulating the expression of chemokines CCR8 and CCR6.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Artificial Intelligence Models May Aid in Predicting Lymph Node Metastasis in Patients with T1 Colorectal Cancer
Ji Eun BAEK ; Hahn YI ; Seung Wook HONG ; Subin SONG ; Ji Young LEE ; Sung Wook HWANG ; Sang Hyoung PARK ; Dong-Hoon YANG ; Byong Duk YE ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Namkug KIM ; Jeong-Sik BYEON
Gut and Liver 2025;19(1):69-76
Background/Aims:
Inaccurate prediction of lymph node metastasis (LNM) may lead to unnecessary surgery following endoscopic resection of T1 colorectal cancer (CRC). We aimed to validate the usefulness of artificial intelligence (AI) models for predicting LNM in patients with T1 CRC.
Methods:
We analyzed the clinical data, laboratory results, pathological reports, and endoscopic findings of patients who underwent radical surgery for T1 CRC. We developed AI models to predict LNM using four algorithms: regularized logistic regression classifier (RLRC), random forest classifier (RFC), CatBoost classifier (CBC), and the voting classifier (VC). Four histological factors and four endoscopic findings were included to develop AI models. Areas under the receiver operating characteristics curves (AUROCs) were measured to distinguish AI model performance in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines.
Results:
Among 1,386 patients with T1 CRC, 173 patients (12.5%) had LNM. The AUROC values of the RLRC, RFC, CBC, and VC models for LNM prediction were significantly higher (0.673, 0.640, 0.679, and 0.677, respectively) than the 0.525 suggested in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines (vs RLRC, p<0.001; vs RFC, p=0.001; vs CBC, p<0.001; vs VC, p<0.001). The AUROC value was similar between T1 colon versus T1 rectal cancers (0.718 vs 0.615, p=0.700). The AUROC value was also similar between the initial endoscopic resection and initial surgery groups (0.581 vs 0.746, p=0.845).
Conclusions
AI models trained on the basis of endoscopic findings and pathological features performed well in predicting LNM in patients with T1 CRC regardless of tumor location and initial treatment method.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Artificial Intelligence Models May Aid in Predicting Lymph Node Metastasis in Patients with T1 Colorectal Cancer
Ji Eun BAEK ; Hahn YI ; Seung Wook HONG ; Subin SONG ; Ji Young LEE ; Sung Wook HWANG ; Sang Hyoung PARK ; Dong-Hoon YANG ; Byong Duk YE ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Namkug KIM ; Jeong-Sik BYEON
Gut and Liver 2025;19(1):69-76
Background/Aims:
Inaccurate prediction of lymph node metastasis (LNM) may lead to unnecessary surgery following endoscopic resection of T1 colorectal cancer (CRC). We aimed to validate the usefulness of artificial intelligence (AI) models for predicting LNM in patients with T1 CRC.
Methods:
We analyzed the clinical data, laboratory results, pathological reports, and endoscopic findings of patients who underwent radical surgery for T1 CRC. We developed AI models to predict LNM using four algorithms: regularized logistic regression classifier (RLRC), random forest classifier (RFC), CatBoost classifier (CBC), and the voting classifier (VC). Four histological factors and four endoscopic findings were included to develop AI models. Areas under the receiver operating characteristics curves (AUROCs) were measured to distinguish AI model performance in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines.
Results:
Among 1,386 patients with T1 CRC, 173 patients (12.5%) had LNM. The AUROC values of the RLRC, RFC, CBC, and VC models for LNM prediction were significantly higher (0.673, 0.640, 0.679, and 0.677, respectively) than the 0.525 suggested in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines (vs RLRC, p<0.001; vs RFC, p=0.001; vs CBC, p<0.001; vs VC, p<0.001). The AUROC value was similar between T1 colon versus T1 rectal cancers (0.718 vs 0.615, p=0.700). The AUROC value was also similar between the initial endoscopic resection and initial surgery groups (0.581 vs 0.746, p=0.845).
Conclusions
AI models trained on the basis of endoscopic findings and pathological features performed well in predicting LNM in patients with T1 CRC regardless of tumor location and initial treatment method.
9.Artificial Intelligence Models May Aid in Predicting Lymph Node Metastasis in Patients with T1 Colorectal Cancer
Ji Eun BAEK ; Hahn YI ; Seung Wook HONG ; Subin SONG ; Ji Young LEE ; Sung Wook HWANG ; Sang Hyoung PARK ; Dong-Hoon YANG ; Byong Duk YE ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Namkug KIM ; Jeong-Sik BYEON
Gut and Liver 2025;19(1):69-76
Background/Aims:
Inaccurate prediction of lymph node metastasis (LNM) may lead to unnecessary surgery following endoscopic resection of T1 colorectal cancer (CRC). We aimed to validate the usefulness of artificial intelligence (AI) models for predicting LNM in patients with T1 CRC.
Methods:
We analyzed the clinical data, laboratory results, pathological reports, and endoscopic findings of patients who underwent radical surgery for T1 CRC. We developed AI models to predict LNM using four algorithms: regularized logistic regression classifier (RLRC), random forest classifier (RFC), CatBoost classifier (CBC), and the voting classifier (VC). Four histological factors and four endoscopic findings were included to develop AI models. Areas under the receiver operating characteristics curves (AUROCs) were measured to distinguish AI model performance in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines.
Results:
Among 1,386 patients with T1 CRC, 173 patients (12.5%) had LNM. The AUROC values of the RLRC, RFC, CBC, and VC models for LNM prediction were significantly higher (0.673, 0.640, 0.679, and 0.677, respectively) than the 0.525 suggested in accordance with the Japanese Society for Cancer of the Colon and Rectum guidelines (vs RLRC, p<0.001; vs RFC, p=0.001; vs CBC, p<0.001; vs VC, p<0.001). The AUROC value was similar between T1 colon versus T1 rectal cancers (0.718 vs 0.615, p=0.700). The AUROC value was also similar between the initial endoscopic resection and initial surgery groups (0.581 vs 0.746, p=0.845).
Conclusions
AI models trained on the basis of endoscopic findings and pathological features performed well in predicting LNM in patients with T1 CRC regardless of tumor location and initial treatment method.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.