1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
4.Digital therapeutics in Korea: current status, challenges, and future directions – a narrative review
Hee Jun SHIN ; Ik Tae CHO ; Wan Suk CHOI ; Hong Rae KIM ; Min Bong KANG ; Won Jong YANG
Journal of Yeungnam Medical Science 2025;42(1):8-
Digital therapeutics (DTx) are emerging as a transformative innovation in healthcare offering evidence-based digital interventions for the treatment, management, and prevention of various diseases and disorders. In Korea, DTx have gained significant attention as potential solutions to the increasing burden of chronic diseases and mental health conditions. However, the Korean DTx market faces several challenges that hinder its widespread adoption and integration into the national healthcare system. This study provides a comprehensive analysis of the current state of the DTx market in Korea, identifies the key challenges impeding its growth, and proposes strategies for overcoming these obstacles. This study utilized a literature review and market analysis approach to examine the latest research, industry reports, and regulatory documents related to DTx. The analysis focused on three primary areas: (1) the current regulatory landscape, (2) technological advancements and challenges, and (3) economic and commercial factors influencing DTx adoption in Korea. A comparative analysis of global regulatory practices was also conducted to identify best practices. The findings revealed that while Korea has made significant strides in supporting DTx development, the market remains in its early stages. The key challenges include underdeveloped regulatory frameworks, issues with data quality and security, and a lack of established reimbursement pathways. We recommend developing tailored regulatory frameworks for DTx, enhancing policy support for small and medium-sized enterprises involved in DTx development, and increasing investments in technological infrastructure. By addressing these challenges, Korea could position itself as a leader in the global DTx market, delivering innovative and effective treatments to enhance patient care and outcomes.
5.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
6.Clinical Practice Guidelines for Dementia: Recommendations for Cholinesterase Inhibitors and Memantine
Yeshin KIM ; Dong Woo KANG ; Geon Ha KIM ; Ko Woon KIM ; Hee-Jin KIM ; Seunghee NA ; Kee Hyung PARK ; Young Ho PARK ; Gihwan BYEON ; Jeewon SUH ; Joon Hyun SHIN ; YongSoo SHIM ; YoungSoon YANG ; Yoo Hyun UM ; Seong-il OH ; Sheng-Min WANG ; Bora YOON ; Sun Min LEE ; Juyoun LEE ; Jin San LEE ; Jae-Sung LIM ; Young Hee JUNG ; Juhee CHIN ; Hyemin JANG ; Miyoung CHOI ; Yun Jeong HONG ; Hak Young RHEE ; Jae-Won JANG ;
Dementia and Neurocognitive Disorders 2025;24(1):1-23
Background:
and Purpose: This clinical practice guideline provides evidence-based recommendations for treatment of dementia, focusing on cholinesterase inhibitors and N-methyl-D-aspartate (NMDA) receptor antagonists for Alzheimer’s disease (AD) and other types of dementia.
Methods:
Using the Population, Intervention, Comparison, Outcomes (PICO) framework, we developed key clinical questions and conducted systematic literature reviews. A multidisciplinary panel of experts, organized by the Korean Dementia Association, evaluated randomized controlled trials and observational studies. Recommendations were graded for evidence quality and strength using Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology.
Results:
Three main recommendations are presented: (1) For AD, cholinesterase inhibitors (donepezil, rivastigmine, galantamine) are strongly recommended for improving cognition and daily function based on moderate evidence; (2) Cholinesterase inhibitors are conditionally recommended for vascular dementia and Parkinson’s disease dementia, with a strong recommendation for Lewy body dementia; (3) For moderate to severe AD, NMDA receptor antagonist (memantine) is strongly recommended, demonstrating significant cognitive and functional improvements. Both drug classes showed favorable safety profiles with manageable side effects.
Conclusions
This guideline offers standardized, evidence-based pharmacologic recommendations for dementia management, with specific guidance on cholinesterase inhibitors and NMDA receptor antagonists. It aims to support clinical decision-making and improve patient outcomes in dementia care. Further updates will address emerging treatments, including amyloid-targeting therapies, to reflect advances in dementia management.
7.Assessing the Efficacy of Bortezomib and Dexamethasone for Induction and Maintenance Therapy in Relapsed/Refractory Cutaneous T-Cell Lymphoma: A Phase II CISL1701/BIC Study
Yoon Seok CHOI ; Joonho SHIM ; Ka-Won KANG ; Sang Eun YOON ; Jun Sik HONG ; Sung Nam LIM ; Ho-Young YHIM ; Jung Hye KWON ; Gyeong-Won LEE ; Deok-Hwan YANG ; Sung Yong OH ; Ho-Jin SHIN ; Hyeon-Seok EOM ; Dok Hyun YOON ; Hong Ghi LEE ; Seong Hyun JEONG ; Won Seog KIM ; Seok Jin KIM
Cancer Research and Treatment 2025;57(1):267-279
Purpose:
This multicenter, open-label, phase II trial evaluated the efficacy and safety of bortezomib combined with dexamethasone for the treatment of relapsed/refractory cutaneous T-cell lymphoma (CTCL) in previously treated patients across 14 institutions in South Korea.
Materials and Methods:
Between September 2017 and July 2020, 29 patients with histologically confirmed CTCL received treatment, consisting of eight 4-week cycles of induction therapy followed by maintenance therapy, contingent upon response, for up to one year. The primary endpoint was the proportion of patients achieving an objective global response.
Results:
Thirteen of the 29 patients (44.8%) achieved an objective global response, including two complete responses. The median progression-free survival (PFS) was 5.8 months, with responders showing a median PFS of 14.0 months. Treatment-emergent adverse events were generally mild, with a low incidence of peripheral neuropathy and hematologic toxicities. Despite the trend toward shorter PFS in patients with higher mutation burdens, genomic profiling before and after treatment showed no significant emergence of new mutations indicative of disease progression.
Conclusion
This study supports the use of bortezomib and dexamethasone as a viable and safe treatment option for previously treated CTCL, demonstrating substantial efficacy and manageability in adverse effects. Further research with a larger cohort is suggested to validate these findings and explore the prognostic value of mutation profiles.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Digital therapeutics in Korea: current status, challenges, and future directions – a narrative review
Hee Jun SHIN ; Ik Tae CHO ; Wan Suk CHOI ; Hong Rae KIM ; Min Bong KANG ; Won Jong YANG
Journal of Yeungnam Medical Science 2025;42(1):8-
Digital therapeutics (DTx) are emerging as a transformative innovation in healthcare offering evidence-based digital interventions for the treatment, management, and prevention of various diseases and disorders. In Korea, DTx have gained significant attention as potential solutions to the increasing burden of chronic diseases and mental health conditions. However, the Korean DTx market faces several challenges that hinder its widespread adoption and integration into the national healthcare system. This study provides a comprehensive analysis of the current state of the DTx market in Korea, identifies the key challenges impeding its growth, and proposes strategies for overcoming these obstacles. This study utilized a literature review and market analysis approach to examine the latest research, industry reports, and regulatory documents related to DTx. The analysis focused on three primary areas: (1) the current regulatory landscape, (2) technological advancements and challenges, and (3) economic and commercial factors influencing DTx adoption in Korea. A comparative analysis of global regulatory practices was also conducted to identify best practices. The findings revealed that while Korea has made significant strides in supporting DTx development, the market remains in its early stages. The key challenges include underdeveloped regulatory frameworks, issues with data quality and security, and a lack of established reimbursement pathways. We recommend developing tailored regulatory frameworks for DTx, enhancing policy support for small and medium-sized enterprises involved in DTx development, and increasing investments in technological infrastructure. By addressing these challenges, Korea could position itself as a leader in the global DTx market, delivering innovative and effective treatments to enhance patient care and outcomes.

Result Analysis
Print
Save
E-mail