1.Preliminary Investigation on Efficacy and Safety of Substance P-Coated Stent for Promoting Re-Endothelialization: A Porcine Coronary Artery Restenosis Model
Dae Sung PARK ; Seok OH ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Young HYUN ; Kyung Hoon CHO ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Manuel HERMIDA-PRIETO ; José Manuel VÁZQUEZ-RODRIGUEZ ; Juan Luis GUTIÉRREZ- CHICO ; Luis MARINÃS-PARDO ; Kyung Seob LIM ; Jun-Kyu PARK ; Dae-Heung BYEON ; Young-Nan CHO ; Seung-Jung KEE ; Doo Sun SIM ; Myung Ho JEONG
Tissue Engineering and Regenerative Medicine 2024;21(1):53-64
BACKGROUND:
Current polymer-based drug-eluting stents (DESs) have fundamental issues about inflammation and delayed re-endothelializaton of the vessel wall. Substance-P (SP), which plays an important role in inflammation and endothelial cells, has not yet been applied to coronary stents. Therefore, this study compares poly lactic-co-glycolic acid (PLGA)-based everolimus-eluting stents (PLGA-EESs) versus 2-methacryloyloxyethyl phosphorylcholine (MPC)-based SP-eluting stents (MPC-SPs) in in-vitro and in-vivo models.
METHODS:
The morphology of the stent surface and peptide/drug release kinetics from stents were evaluated. The invitro proliferative effect of SP released from MPC-SP is evaluated using human umbilical vein endothelial cell. Finally, the safety and efficacy of the stent are evaluated after inserting it into a pig’s coronary artery.
RESULTS:
Similar to PLGA-EES, MPC-SP had a uniform surface morphology with very thin coating layer thickness (2.074 lm). MPC-SP showed sustained drug release of SP for over 2 weeks. Endothelial cell proliferation was significantly increased in groups treated with SP (n = 3) compared with the control (n = 3) and those with everolimus (n = 3) (SP:118.9 ± 7.61% vs. everolimus: 64.3 ± 12.37% vs. the control: 100 ± 6.64%, p < 0.05). In the animal study, the percent stenosis was higher in MPC-SP group (n = 7) compared to PLGA-EES group (n = 7) (MPC-SP: 28.6 ± 10.7% vs. PLGAEES: 16.7 ± 6.3%, p < 0.05). MPC-SP group showed, however, lower inflammation (MPC-SP: 0.3 ± 0.26 vs. PLGAEES: 1.2 ± 0.48, p < 0.05) and fibrin deposition (MPC-SP: 1.0 ± 0.73 vs. PLGA-EES: 1.5 ± 0.59, p < 0.05) around the stent strut. MPC-SP showed more increased expression of cluster of differentiation 31, suggesting enhanced reendothelialization.
CONCLUSION
Compared to PLGA-EES, MPC-SP demonstrated more decreased inflammation of the vascular wall and enhanced re-endothelialization and stent coverage. Hence, MPC-SP has the potential therapeutic benefits for the treatment of coronary artery disease by solving limitations of currently available DESs.
2.Efficacy and Safety Evaluation of Tacrolimus-Eluting Stent in a Porcine Coronary Artery Model
Dae Sung PARK ; Mi Hyang NA ; Myung Ho JEONG ; Doo Sun SIM ; Yu Jeong JIN ; Hae Jin KEE ; Mun Ki KIM ; Jeong Ha KIM ; Young Joon HONG ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Kyung Seob LIM ; Dae-Heung BYEON ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2024;21(5):723-735
BACKGROUND:
A drug-eluting stent (DES) is a highly beneficial medical device used to widen or unblock narrowed blood vessels. However, the drugs released by the implantation of DES may hinder the re-endothelialization process, increasing the risk of late thrombosis. We have developed a tacrolimus-eluting stent (TES) that as acts as a potent antiproliferative and immunosuppressive agent, enhancing endothelial regeneration. In addition, we assessed the safety and efficacy of TES through both in vitro and in vivo tests.
METHODS:
Tacrolimus and Poly(lactic-co-glycolic acid) (PLGA) were applied to the metal stent using electrospinning equipment. The surface morphology of the stent was examined before and after coating using a scanning electron microscope (SEM) and energy dispersive X-rays (EDX). The drug release test was conducted through high-performance liquid chromatography (HPLC). Cell proliferation and migration assays were performed using smooth muscle cells (SMC).The stent was then inserted into the porcine coronary artery and monitored for a duration of 4 weeks.
RESULTS:
SEM analysis confirmed that the coating surface was uniform. Furthermore, EDX analysis showed that the surface was coated with both polymer and drug components. The HPCL analysis of TCL at a wavelength of 215 nm revealed that the drug was continuously released over a period of 4 weeks. Smooth muscle cell migration was significantly decreased in the tacrolimus group (54.1% ± 11.90%) compared to the non-treated group (90.1% ± 4.86%). In animal experiments, the stenosis rate was significantly reduced in the TES group (29.6% ± 7.93%) compared to the bare metal stent group (41.3% ± 10.18%). Additionally, the fibrin score was found to be lower in the TES group compared to the group treated with a sirolimus-eluting stent (SES).
CONCLUSION
Similar to SES, TES reduces neointimal proliferation in a porcine coronary artery model, specifically decreasing the fibrins score. Therefore, tacrolimus could be considered a promising drug for reducing restenosis and thrombosis.
3.Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
Dae Sung PARK ; Myung Ho JEONG ; Yu Jeong JIN ; Mi Hyang NA ; Doo Sun SIM ; Munki KIM ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Jeong Ha KIM ; Kyung Seob LIM ; Jun-Kyu PARK ; Han Ki KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2023;20(2):239-249
BACKGROUND:
Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model.
METHODS:
The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-toartery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation.
RESULTS:
Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 lm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness.
CONCLUSION
BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.
4.Assessment of the Clinical Heterogeneity of Kawasaki Disease Using Genetic Variants of BLK and FCGR2A
Bo Kyung SIM ; Hyein PARK ; Jae Jung KIM ; Sin Weon YUN ; Jeong Jin YU ; Kyung Lim YOON ; Kyung Yil LEE ; Hong Ryang KIL ; Gi Beom KIM ; Myung Ki HAN ; Min Seob SONG ; Hyoung Doo LEE ; Kee Soo HA ; Sejung SOHN ; Young Mi HONG ; Gi Young JANG ; Jong Keuk LEE ;
Korean Circulation Journal 2019;49(1):99-108
BACKGROUND AND OBJECTIVES: Patients with Kawasaki disease (KD) are clinically heterogeneous because its diagnosis is based solely on clinical observation and there are no definitive biomarkers. We dissected the clinical heterogeneity of KD patients using the KD-associated genetic variants. METHODS: We performed a genetic association analysis in several KD subgroups categorized by clinical characteristics using the KD-associated variants of the B lymphoid tyrosine kinase (BLK; rs6993775) and Fc gamma receptor II a (FCGR2A; rs1801274) in a large number of case (n=1,011) and control (n=4,533) samples. RESULTS: BLK and FCGR2A were very significantly associated with KD in Korean KD patients (odds ratio [OR],1.48; p=4.63×10⁻¹¹ for BLK, and OR, 1.26; p=1.42×10⁻⁴ for FCGR2A). However, in KD subgroup analysis, we found that neither BLK nor FCGR2A were associated with either incomplete Kawasaki disease (iKD) type patients or those older than 5 years of age (p>0.2), suggesting that patients with iKD or those older than 5 years of age are a unique subgroup of KD. In genetic association analysis after excluding iKD patients and those older than 5 years old, we found that BLK was associated with all KD subgroups, whereas FCGR2A was specifically associated with male KD patients younger than 1 year of age (OR, 2.22; p=2.35×10⁻⁵). CONCLUSIONS: KD is a clinically and genetically heterogeneous disease. These findings will provide new insights into the clinical and genetic heterogeneity of KD.
Biomarkers
;
Diagnosis
;
Genetic Heterogeneity
;
Genome-Wide Association Study
;
Humans
;
Male
;
Mucocutaneous Lymph Node Syndrome
;
Polymorphism, Single Nucleotide
;
Population Characteristics
;
Protein-Tyrosine Kinases
5.Influence of Local Myocardial Infarction on Endothelial Function, Neointimal Progression, and Inflammation in Target and Non-Target Vascular Territories in a Porcine Model of Acute Myocardial Infarction
Hyun Kuk KIM ; Han Byul KIM ; Joo Myung LEE ; Sung Soo KIM ; In Ho BAE ; Dae Sung PARK ; Jun Kyu PARK ; Jae Won SHIM ; Joo Young NA ; Min Young LEE ; Joong Sun KIM ; Doo Sun SIM ; Young Joon HONG ; Chang Wook NAM ; Joon Hyung DOH ; Jonghanne PARK ; Bon Kwon KOO ; Sun Uk KIM ; Kyung Seob LIM ; Myung Ho JEONG
Journal of Korean Medical Science 2019;34(19):e145-
BACKGROUND: Patients with acute myocardial infarction (AMI) have worse clinical outcomes than those with stable coronary artery disease despite revascularization. Non-culprit lesions of AMI also involve more adverse cardiovascular events. This study aimed to investigate the influence of AMI on endothelial function, neointimal progression, and inflammation in target and non-target vessels. METHODS: In castrated male pigs, AMI was induced by balloon occlusion and reperfusion into the left anterior descending artery (LAD). Everolimus-eluting stents (EES) were implanted in the LAD and left circumflex (LCX) artery 2 days after AMI induction. In the control group, EES were implanted in the LAD and LCX in a similar fashion without AMI induction. Endothelial function was assessed using acetylcholine infusion before enrollment, after the AMI or sham operation, and at 1 month follow-up. A histological examination was conducted 1 month after stenting. RESULTS: A total of 10 pigs implanted with 20 EES in the LAD and LCX were included. Significant paradoxical vasoconstriction was assessed after acetylcholine challenge in the AMI group compared with the control group. In the histologic analysis, the AMI group showed a larger neointimal area and larger area of stenosis than the control group after EES implantation. Peri-strut inflammation and fibrin formation were significant in the AMI group without differences in injury score. The non-target vessel of the AMI also showed similar findings to the target vessel compared with the control group. CONCLUSION: In the pig model, AMI events induced endothelial dysfunction, inflammation, and neointimal progression in the target and non-target vessels.
Acetylcholine
;
Arteries
;
Balloon Occlusion
;
Constriction, Pathologic
;
Coronary Artery Disease
;
Drug-Eluting Stents
;
Endothelium
;
Fibrin
;
Follow-Up Studies
;
Humans
;
Inflammation
;
Male
;
Myocardial Infarction
;
Reperfusion
;
Stents
;
Swine
;
Vasoconstriction
6.Assessment of the Clinical Heterogeneity of Kawasaki Disease Using Genetic Variants of BLK and FCGR2A
Bo Kyung SIM ; Hyein PARK ; Jae Jung KIM ; Sin Weon YUN ; Jeong Jin YU ; Kyung Lim YOON ; Kyung Yil LEE ; Hong Ryang KIL ; Gi Beom KIM ; Myung Ki HAN ; Min Seob SONG ; Hyoung Doo LEE ; Kee Soo HA ; Sejung SOHN ; Young Mi HONG ; Gi Young JANG ; Jong Keuk LEE ;
Korean Circulation Journal 2019;49(1):99-108
BACKGROUND AND OBJECTIVES:
Patients with Kawasaki disease (KD) are clinically heterogeneous because its diagnosis is based solely on clinical observation and there are no definitive biomarkers. We dissected the clinical heterogeneity of KD patients using the KD-associated genetic variants.
METHODS:
We performed a genetic association analysis in several KD subgroups categorized by clinical characteristics using the KD-associated variants of the B lymphoid tyrosine kinase (BLK; rs6993775) and Fc gamma receptor II a (FCGR2A; rs1801274) in a large number of case (n=1,011) and control (n=4,533) samples.
RESULTS:
BLK and FCGR2A were very significantly associated with KD in Korean KD patients (odds ratio [OR],1.48; p=4.63×10â»Â¹Â¹ for BLK, and OR, 1.26; p=1.42×10â»â´ for FCGR2A). However, in KD subgroup analysis, we found that neither BLK nor FCGR2A were associated with either incomplete Kawasaki disease (iKD) type patients or those older than 5 years of age (p>0.2), suggesting that patients with iKD or those older than 5 years of age are a unique subgroup of KD. In genetic association analysis after excluding iKD patients and those older than 5 years old, we found that BLK was associated with all KD subgroups, whereas FCGR2A was specifically associated with male KD patients younger than 1 year of age (OR, 2.22; p=2.35×10â»âµ).
CONCLUSIONS
KD is a clinically and genetically heterogeneous disease. These findings will provide new insights into the clinical and genetic heterogeneity of KD.
7.Deliberate Self-harm among Young People Begins to Increase at the Very Early Age: a Nationwide Study.
Kwang Yul JUNG ; Taerim KIM ; Sung Yeon HWANG ; Tae Rim LEE ; Hee YOON ; Tae Gun SHIN ; Min Seob SIM ; Won Chul CHA ; Hong Jin JEON
Journal of Korean Medical Science 2018;33(30):e191-
BACKGROUND: Suicide in young people is one of most common cause of death; and deliberate self-harm (DSH) is important indicator of suicide. It is currently unclear how old the rate begins to increase or when it reaches to the same level with adults. The purpose of this study was to find beginning age of DSH and compare their characteristics with adults. METHODS: This study retrospectively reviewed 5 years of nationwide prospective registry named Emergency Department-based Injury In-depth Surveillance (EDIIS) registry composed of all injured patients who were admitted to twenty tertiary university hospital emergency departments. Injured patients aged 29 years or younger from January 1, 2011 to December 31, 2015 were included. Incidence rate of DSH in all age was described. Patients were stratified by age: early teenage (11–15 years), late teenage (16–19 years), and early adulthood (20–29 years). Data of early teenage group were compared to those of other groups for examining their characteristics. RESULTS: Among 588,549 injury patients, 8,400 patients reported DSH. The rate began to rise at age 11 and reach at age 16 which was equivalent to that of age 20 to 29. Early teenage had significantly higher excess mortality ratio based injury severity score (EMR-ISS) and had almost same level without significant difference in operation incidence or mortality compared to late teenage and early adulthood. CONCLUSION: DSH rate began to rise at age 11, reaching adulthood level at age 16 in Korea.
Adult
;
Cause of Death
;
Emergencies
;
Emergency Service, Hospital
;
Humans
;
Incidence
;
Injury Severity Score
;
Korea
;
Mortality
;
Prospective Studies
;
Retrospective Studies
;
Self-Injurious Behavior*
;
Suicide
8.An Ofloxacin-Induced Anaphylaxis through an IgG4-Mediated but Not IgE-Mediated Basophil Activation Mechanism.
Ji Hye KIM ; Dae Hong SEO ; Ga Young BAN ; Eun Mi YANG ; Yoo Seob SHIN ; Young Min YE ; Hae Sim PARK
Korean Journal of Critical Care Medicine 2017;32(3):302-305
No abstract available.
Anaphylaxis*
;
Basophils*
9.The Control of Drug Release and Vascular Endothelialization after Hyaluronic Acid-Coated Paclitaxel Multi-Layer Coating Stent Implantation in Porcine Coronary Restenosis Model.
In Ho BAE ; Myung Ho JEONG ; Ju Han KIM ; Yong Hwan PARK ; Kyung Seob LIM ; Dae Sung PARK ; Jae Won SHIM ; Jung Ha KIM ; Youngkeun AHN ; Young Joon HONG ; Doo Sun SIM
Korean Circulation Journal 2017;47(1):123-131
BACKGROUND AND OBJECTIVES: Hyaluronic acid (HA) is highly biocompatible with cells and the extracellular matrix. In contrast to degradation products of a synthetic polymer, degradation products of HA do not acidify the local environment. The aim of this study was to fabricate an HA-coated paclitaxel (PTX)-eluting stent via simple ionic interactions and to evaluate its effects in vitro and in vivo. MATERIALS AND METHODS: HA and catechol were conjugated by means of an activation agent, and then the stent was immersed in this solution (resulting in a HA-coated stent). After that, PTX was immobilized on the HA-coated stent (resulting in a hyaluronic acid-coated paclitaxel-eluting stent [H-PTX stent]). Study groups were divided into 4 groups: bare metal stent (BMS), HA, H-PTX, and poly (L-lactide)-coated paclitaxel-eluting stent (P-PTX). Stents were randomly implanted in a porcine coronary artery. After 4 weeks, vessels surrounding the stents were isolated and subjected to various analyses. RESULTS: Smoothness of the surface was maintained after expansion of the stent. In contrast to a previous study on a PTX-eluting stent, in this study, the PTX was effectively released up to 14 days (a half amount of PTX in 4 days). The proliferation of smooth muscle cells was successfully inhibited (by 80.5±12.11% at 7 days of culture as compared to the control) by PTX released from the stent. Animal experiments showed that the H-PTX stent does not induce an obvious inflammatory response. Nevertheless, restenosis was clearly decreased in the H-PTX stent group (9.8±3.25%) compared to the bare-metal stent group (29.7±8.11%). CONCLUSION: A stent was stably coated with PTX via simple ionic interactions with HA. Restenosis was decreased in the H-PTX group. These results suggest that HA, a natural polymer, is suitable for fabrication of drug-eluting stents (without inflammation) as an alternative to a synthetic polymer.
Animal Experimentation
;
Coronary Restenosis*
;
Coronary Vessels
;
Drug Evaluation, Preclinical
;
Drug Liberation*
;
Drug-Eluting Stents
;
Extracellular Matrix
;
Hyaluronic Acid
;
In Vitro Techniques
;
Myocytes, Smooth Muscle
;
Paclitaxel*
;
Polymers
;
Stents*
10.Effect of Stents Coated with Artemisinin or Dihydroartemisinin in a Porcine Coronary Restenosis Model.
Suyoung JANG ; Myung Ho JEONG ; Kyung Seob LIM ; In Ho BAE ; Jun Kyu PARK ; Dae Sung PARK ; Jae Won SHIM ; Jung Ha KIM ; Hyun Kuk KIM ; Doo Sun SIM ; Young Joon HONG ; Youngkeun AHN ; Jung Chaee KANG
Korean Circulation Journal 2017;47(1):115-122
BACKGROUND AND OBJECTIVES: Artemisinin and dihydroartemisinin are drugs used to treat malaria. These drugs suppress inflammatory reactions. The aim of this study was to examine the anti-intima hyperplasia effect of a novel drug-eluting stent with artemisinin or dihydroartemisinin in a porcine coronary restenosis model. MATERIALS AND METHODS: Pigs were randomized into four groups; in the first, the coronary arteries (20 pigs, a total of 40 coronary arteries, with 10 coronary arteries in each group) was implanted with bare metal stents (BMS, n=10); the second group was given polymer-coated stents (PCS, n=10); the third group was treated with artemisinin-eluting stents (AES, n=10); and the fourth group was given dihydroartemisinin-eluting stents (DAES, n=10). Histopathologic analysis was performed 28 days after stenting. RESULTS: The injury and fibrin scores among the four groups were not significantly different. However, the internal elastic lamina, lumen area, and neointima area were significantly different. Moreover, the percent area of stenosis (46.2±18.66% in BMS vs. 89.4±10.92% in PCS vs. 83.3±17.07% in AES vs. 36.7±11.20% in DAES, p<0.0001) and inflammation score (1.0 [range: 1.0-1.0] vs. 3.0 [range: 2.25-3.0] vs. 3.0 [range: 1.0-3.0] vs. 2.0 [range: 1.75-3.0] in BMS, PCS, AES, and DAES, respectively; p<0.001) were markedly decreased in the DAES group compared to the PCS group. CONCLUSION: DES, which uses a natural substance, dihydroartemisinin, showed a neointima and inflammatory suppressive effect in a porcine coronary restenosis model.
Constriction, Pathologic
;
Coronary Restenosis*
;
Coronary Vessels
;
Drug-Eluting Stents
;
Fibrin
;
Hyperplasia
;
Inflammation
;
Malaria
;
Neointima
;
Stents*
;
Swine

Result Analysis
Print
Save
E-mail