1.A Case of Takayasu's Arteritis with Aortic Root Abscess after AVR and during Biologic Drug Administration
Shinji KAWAGUCHI ; Masanao NAKAI ; Takahiro OZAWA ; Daisuke UCHIYAMA ; Yuta MIYANO ; Yasuhiko TERAI ; Muneaki YAMADA ; Ryota NOMURA ; Hiroshi MITSUOKA
Japanese Journal of Cardiovascular Surgery 2024;53(2):66-69
		                        		
		                        			
		                        			A 32-year-old woman was diagnosed with Takayasu's arteritis 5 years ago and underwent aortic valve replacement for aortic regurgitation 1 year ago. She had been taking Prednisolone and Azathioprine for Takayasu's arteritis, but these drugs were switched to subcutaneous Tocilizumab 4 months ago. One month ago, she had dyspnea on exertion, and 2 days ago, chest discomfort appeared, and she came to our hospital. Blood tests showed CRP 0.02 mg/dl, and echocardiography and CT showed perivalvular leakage and aortic root pseudoaneurysm, which led us to suspect aortic root pseudoaneurysm due to Takayasu's arteritis and to perform emergency surgery. Although a circumferential pseudoaneurysm was observed at the aortic root, no destruction of the prosthetic valve was observed. The suture from the previous surgery was attached to the sawing cuff of the prosthetic valve, and the prosthetic valve was not fixed to the aortic annulus and could be easily removed. The Bentall operation was performed using a bioprosthetic valve. The histopathological diagnosis was subacute infective endocarditis, and the patient was diagnosed with a pseudoaneurysm of the aortic root due to infection. The patient had a good postoperative course and was discharged home on the 19th day. We report a case of Takayasu's arteritis with valve annular abscess after AVR, which was treated surgically during biologic drug administration.
		                        		
		                        		
		                        		
		                        	
2.Prognosis of biopsy-confirmed metabolic dysfunction- associated steatotic liver disease: A sub-analysis of the CLIONE study
Michihiro IWAKI ; Hideki FUJII ; Hideki HAYASHI ; Hidenori TOYODA ; Satoshi OEDA ; Hideyuki HYOGO ; Miwa KAWANAKA ; Asahiro MORISHITA ; Kensuke MUNEKAGE ; Kazuhito KAWATA ; Tsubasa TSUTSUMI ; Koji SAWADA ; Tatsuji MAESHIRO ; Hiroshi TOBITA ; Yuichi YOSHIDA ; Masafumi NAITO ; Asuka ARAKI ; Shingo ARAKAKI ; Takumi KAWAGUCHI ; Hidenao NORITAKE ; Masafumi ONO ; Tsutomu MASAKI ; Satoshi YASUDA ; Eiichi TOMITA ; Masato YONEDA ; Akihiro TOKUSHIGE ; Yoshihiro KAMADA ; Hirokazu TAKAHASHI ; Shinichiro UEDA ; Shinichi AISHIMA ; Yoshio SUMIDA ; Atsushi NAKAJIMA ; Takeshi OKANOUE ;
Clinical and Molecular Hepatology 2024;30(2):225-234
		                        		
		                        			 Background/Aims:
		                        			Metabolic dysfunction-associated steatotic liver disease (MASLD) was recently proposed as an alternative disease concept to nonalcoholic fatty liver disease (NAFLD). We aimed to investigate the prognosis of patients with biopsy-confirmed MASLD using data from a multicenter study. 
		                        		
		                        			Methods:
		                        			This was a sub-analysis of the Clinical Outcome Nonalcoholic Fatty Liver Disease (CLIONE) study that included 1,398 patients with NAFLD. Liver biopsy specimens were pathologically diagnosed and histologically scored using the NASH Clinical Research Network system, the FLIP algorithm, and the SAF score. Patients who met at least one cardiometabolic criterion were diagnosed with MASLD. 
		                        		
		                        			Results:
		                        			Approximately 99% of cases (n=1,381) were classified as MASLD. Patients with no cardiometabolic risk (n=17) had a significantly lower BMI than patients with MASLD (20.9 kg/m2 vs. 28.0 kg/m2, P<0.001), in addition to significantly lower levels of inflammation, ballooning, NAFLD activity score, and fibrosis stage based on liver histology. These 17 patients had a median follow-up of 5.9 years, equivalent to 115 person-years, with no deaths, liver-related events, cardiovascular events, or extrahepatic cancers. The results showed that the prognosis for pure MASLD was similar to that for the original CLIONE cohort, with 47 deaths and one patient who underwent orthotopic liver transplantation. The leading cause of death was extrahepatic cancer (n=10), while the leading causes of liver-related death were liver failure (n=9), hepatocellular carcinoma (n=8), and cholangiocarcinoma (n=4). 
		                        		
		                        			Conclusions
		                        			Approximately 99% of NAFLD cases were considered MASLD based on the 2023 liver disease nomenclature. The NAFLD-only group, which is not encompassed by MASLD, had a relatively mild histopathologic severity and a favorable prognosis. Consequently, the prognosis of MASLD is similar to that previously reported for NAFLD. 
		                        		
		                        		
		                        		
		                        	
3.Open Stent Grafting for Aortic Arch Aneurysm with an Aberrant Right Subclavian Artery
Shinnosuke GOTO ; Hiroshi MITSUOKA ; Masanao NAKAI ; Takahiro SUZUKI ; Shinji KAWAGUCHI ; Daisuke UCHIYAMA ; Yuta MIYANO ; Muneaki YAMADA ; Yasuhiko TERAI ; Ryouta NOMURA
Japanese Journal of Cardiovascular Surgery 2022;51(6):359-362
		                        		
		                        			
		                        			We report a case of a 56-year-old woman. She had a history of emergent ascending aorta replacement due to type A dissection. Seven years later, aortic arch enlargement (55 mm) was detected on CT scan, and indicated secondary repair. Because of the existence of the aberrant right subclavian artery (ARSA), the safer surgical management needed to be discussed. Total arch replacement with the use of open stent-grafting technique and extra-anatomical reconstruction of ARSA was chosen for the treatment. In the operation, straight woven grafts (7 mm in diameter) were firstly anastomosed to the bilateral axillary arteries. Deep hypothermic circulatory arrest with antegrade cerebral perfusion through median sternotomy was established. The aortic arch was transected between the right and left subclavian arteries. The left subclavian artery was ligated at its origin, and an aortic open stent graft was inserted distally. An aortic reconstruction was performed between the left common carotid artery and the left subclavian artery with a 4 branched J-graft. The left carotid artery was reconstructed anatomically, and the tube grafts anastomosed to the bilateral axillary arteries were reconstructed in an extra-anatomical fashion. On the 11th postoperative days, coil-embolization of the ARSA was performed to complete the treatment. The patient had an uneventful post-operative recovery. Total arch replacement using an open stent-grafting technique was a feasible treatment option for the aortic arch aneurysm with ARSA.
		                        		
		                        		
		                        		
		                        	
4.A Case Report of Partial Aortic Arch Replacement for Traumatic Aortic Arch Injury
Shinnosuke GOTO ; Masanao NAKAI ; Shinji KAWAGUCHI ; Yuta MIYANO ; Muneaki YAMADA ; Yasuhiko TERAI ; Ryota NOMURA ; Hiroshi MITSUOKA ; Fumio YAMASAKI
Japanese Journal of Cardiovascular Surgery 2021;50(1):53-56
		                        		
		                        			
		                        			A 79-year-old woman presented to our hospital with high energy trauma. Enhanced CT revealed injury to the aortic arch. The left carotid artery was pulled out due to extension force and a drawing out lesion formed. Cardiopulmonary bypass was established with cannulation of the right femoral artery and the right atrium, and systemic cooling was started. We opened the aortic arch with deep hypothermic circulatory arrest, and detected a 10 mm drawing out lesion at the bottom of the left carotid artery. Aortic arch was transected at the distal of the left carotid artery to exclude the drawing out lesion, and partial arch replacement was performed. The patient's postoperative course was uneventful, and she was discharged from our hospital without any complication.
		                        		
		                        		
		                        		
		                        	
5.A Mobile Thrombus in the Aortic Arch
Shinji KAWAGUCHI ; Yuta MIYANO ; Shinnosuke GOTO ; Yasuhiko TERAI ; Ryota NOMURA ; Masanao NAKAI ; Hiroshi MITSUOKA ; Fumio YAMAZAKI
Japanese Journal of Cardiovascular Surgery 2021;50(1):57-60
		                        		
		                        			
		                        			A 51-year-old man was referred to our hospital with pain and coldness of the upper left extremity. Contrasted computed tomography revealed a silhouette protruding into the aortic arch. Peripheral embolism in upper left extremity by tumor or thrombosis was suspected. Magnetic resonance imaging revealed a mobile mass in the aortic arch. To prevent recurrent embolization, the mass and the aortic arch to which the mass was attached were excised and partial arch replacement was performed under cardiopulmonary bypass. Histologically, the mass was a fibrin thrombus with no malignancy. The aortic wall showed only mild atherosclerosis of the intima. No thrombotic predisposition such as protein S or C deficiency or antiphospholipid antibody syndrome was observed. Anticoagulant therapy was started and the patient was discharged on postoperative day 10 without recurrent thromboembolism. Three years have passed since the operation and there is no recurrence of thromboembolism.
		                        		
		                        		
		                        		
		                        	
6.Successful Surgical Aortic Valve Replacement for Prosthetic Valve Endocarditis 10 Months after Transcatheter Aortic Valve Implantation
Ryota NOMURA ; Masanao NAKAI ; Shinji KAWAGUCHI ; Yuta MIYANO ; Shinnosuke GOTO ; Yasuhiko TERAI ; Muneaki YAMADA ; Hiroshi MITSUOKA ; Fumio YAMAZAKI
Japanese Journal of Cardiovascular Surgery 2020;49(5):284-287
		                        		
		                        			
		                        			An 87-year-old man underwent a transcatheter aortic valve implantation (TAVI) for severe aortic stenosis. Approximately 8 months later, he was readmitted to our institution because of a cerebral infarction. Viridans Streptococcus was identified from the blood culture, and transesophageal echocardiography revealed a mobile mass on the leaflet. Prosthetic valve endocarditis (PVE) was diagnosed and we initially administered intravenous antibiotic therapy for 4 weeks, after which the patient underwent surgical aortic valve replacement. Herein, we report on the surgical AVR in the patient using a pericardial valve after successful removal of the infected prosthetic valve, and discuss some issues related to this rare complication after TAVI.
		                        		
		                        		
		                        		
		                        	
8.Cervical dystonia in Parkinson’s disease: Retrospective study of later-stage clinical features
Hiroshi Kida ; Shiroh Miura ; Yoshihiro Yamanishi ; Tomoyuki Takahashi ; Takashi Kamada ; Akiko Yorita ; Mitsuyoshi Ayabe ; Hideki Kida ; Tomoaki Hoshino ; Takayuki Taniwaki
Neurology Asia 2018;23(3):245-251
		                        		
		                        			
		                        			Objective: Cervical dystonia (CD) is a clinically under-recognized symptom occurring at the later- to
end-stages of Parkinson’s disease (PD). The frequency of CD and its influence on prognosis have
not been well studied. Here, we conducted an in-depth examination of CD incidence and impact on
disease progression in later-stage PD. Methods: We retrospectively reviewed the clinical features of 22
deceased patients with sporadic PD treated at a hospital in Japan from 1983 to 2008. Results: The most
common cause of death in PD was pneumonia. CD, in particular retrocollis, was frequent in the later
stages of the disease in elderly patients (9/22, 40.9%). Pneumonia incidence increased sharply in the
later period with CD. There was a positive trend between CD duration and duration of pergolide use.
Conclusion: Analysis revealed that CD increases markedly in late- to end-stage PD, which may be
associated with aspiration pneumonia due to dysphagia. Pathological mechanisms underlying CD might
be influenced by treatments including dopamine agonists. Prevention of CD may increase quality of
life and prolong survival of PD patients.
		                        		
		                        		
		                        		
		                        	
9.Efficacy and safety of venous thromboembolism prophylaxis with fondaparinux in women at risk after cesarean section.
Ryuji KAWAGUCHI ; Shoji HARUTA ; Hiroshi KOBAYASHI
Obstetrics & Gynecology Science 2017;60(6):535-541
		                        		
		                        			
		                        			OBJECTIVES: Cesarean section is associated with an increased risk for venous thromboembolism (VTE). The safety and efficacy of primary prophylaxis of fondaparinux, a synthetic sulfated pentasaccharide heparin analog, in women at risk after cesarean section is uncertain. METHODS: This was a retrospective study of 295 cases of pregnant women presenting to a tertiary referral center of Nara, Japan, to evaluate the usefulness of thromboprophylaxis with fondaparinux after cesarean delivery between 2011 and 2012. Patients were initially received unfractionated heparin (once 5,000 IU subcutaneously, twice a day), starting 6 hours after cesarean section for 24 hours, and then treated with fondaparinux (once 2.5 mg daily, subcutaneously) for 5 days. The primary efficacy end-point was an improvement in the incidence of symptomatic VTE or fatal post-cesarean pulmonary thromboembolism. The primary safety end-point was major bleeding during treatment. RESULTS: There were neither any episodes of symptomatic VTE cases nor maternal deaths. A total of 10 patients had a bleeding event. Major bleeding complication was observed in 2 (0.68%) of 295 patients receiving fondaparinux. Non-major bleeding into critical sites was observed in 8 patients, often at surgical sites, and recovery was not delayed. CONCLUSION: This study demonstrates the safety and efficacy of fondaparinux in women at high risk of VTE after cesarean section. Large phase trials comparing clinical outcomes with fondaparinux across a wide spectrum of patients are needed to confirm these observations.
		                        		
		                        		
		                        		
		                        			Cesarean Section*
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Hemorrhage
		                        			;
		                        		
		                        			Heparin
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Incidence
		                        			;
		                        		
		                        			Japan
		                        			;
		                        		
		                        			Maternal Death
		                        			;
		                        		
		                        			Pregnancy
		                        			;
		                        		
		                        			Pregnant Women
		                        			;
		                        		
		                        			Pulmonary Embolism
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Tertiary Care Centers
		                        			;
		                        		
		                        			Venous Thromboembolism*
		                        			
		                        		
		                        	
10.PainVision Apparatus Is Effective for Assessing Low Back Pain.
Seiji OHTORI ; Hiroshi KAWAGUCHI ; Tsuneo TAKEBAYASHI ; Sumihisa ORITA ; Gen INOUE ; Kazuyo YAMAUCHI ; Yasuchika AOKI ; Junichi NAKAMURA ; Tetsuhiro ISHIKAWA ; Masayuki MIYAGI ; Hiroto KAMODA ; Miyako SUZUKI ; Gou KUBOTA ; Yoshihiro SAKUMA ; Yasuhiro OIKAWA ; Kazuhide INAGE ; Takeshi SAINOH ; Jun SATO ; Kazuhisa TAKAHASHI ; Shinichi KONNO
Asian Spine Journal 2014;8(6):793-798
		                        		
		                        			
		                        			STUDY DESIGN: Case series. PURPOSE: To determine the utility of "PainVision" apparatus for the assessment of low back pain. OVERVIEW OF LITERATURE: A newly developed device, the PainVision PS-2100 (Nipro, Osaka, Japan), has been used to assess the perception of pain in a quantitative manner. In the current study, we aimed to evaluate the efficacy of PainVision for the assessment of low back pain. METHODS: We assessed 89 patients with low back pain. The numeric rating scale (NRS) score, McGill Pain Questionnaire (MPQ) score and the degree of pain calculated by PainVision were measured twice at 4-week intervals in each patient. An electrode was patched on the forearm surface of the patients and the degree of pain was automatically calculated (degree of pain=100x[current producing pain comparable with low back pain-current at perception threshold/current at perception threshold]). Correlations between NRS and MPQ scores and the degree of pain were determined using Spearman's rank correlation test. RESULTS: There was a strong correlation between the NRS and MPQ scores at each time point (rs =0.60, p<0.0001). The degree of pain also showed a moderate correlation with NRS and MPQ scores at each time point (rs =0.40, p<0.03). The change in the degree of pain over 4 weeks showed a moderate correlation with changes in the NRS and MPQ scores (rs =0.40, p<0.01). CONCLUSIONS: PainVision as self-reported questionnaires is a useful tool to assess low back pain.
		                        		
		                        		
		                        		
		                        			Electrodes
		                        			;
		                        		
		                        			Forearm
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Low Back Pain*
		                        			;
		                        		
		                        			Pain Measurement
		                        			;
		                        		
		                        			Surveys and Questionnaires
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail